| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.4 L+₹3.3 L (11.7%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹36.5 L+₹8.4 L (29.9%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹37.0 L+₹8.9 L (31.7%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹37.4 L+₹9.3 L (33.1%)Rejected-AOC | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | RAJU AND COMPANY L4 | M/S DIVIJA BUILDERS L3 | M/S P.SWAROOP KUMAR L1 | NEWS CONSTRUCTIONS L6 | D NAGESWAR REDDY L5 | BSA INFRA L2 | VACON INFRASTRUCTURES L8 | M/s Bhavani Constructions L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTES :- In case description of any two or more items of the schedule ‘A’ is same and the tenderer quotes different rates for such items, only lowest rate of such items will be considered for acceptance and subsequently payment will be made upon execution of the items accordingly. | |||||||||||
| 1.01 | Dismantling/removing the textile coverings and cover fillets all as specified | 3,200 | Sqm | 15 ₹48,000 | 15 ₹48,000 | 40 ₹1,28,000 | 10 ₹32,000 Lowest | 20 ₹64,000 | 15 ₹48,000 | 25 ₹80,000 | 32 ₹1,02,400 |
| 2.00 | Demolition of plain cement concrete of any description in any position as in padding concrete, sunken slabs coping, benching, kerbs or mud stops etc and removing the debris outside MOD allas psecified by engineer in charge | 85 | Cum | 700 ₹59,500 | 360 ₹30,600 Lowest | 400 ₹34,000 | 650 ₹55,250 | 450 ₹38,250 | 600 ₹51,000 | 600 ₹51,000 | 662 ₹56,270 |
| 3.00 | M&L PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in terrace (padding layer )finished even surface of 25 mm thick complete all as specified and directed. | 3,200 | Sqm | 145 ₹4,64,000 | 171 ₹5,47,200 | 120 ₹3,84,000 | 200 ₹6,40,000 | 140 ₹4,48,000 | 100 ₹3,20,000 Lowest | 170 ₹5,44,000 | 136 ₹4,35,200 |
| 4.00 | M&L for rendering 10 mm thick in CM 1:3 on concrete roof slabs including mixing water proofing compound at 3% by weight of cement (but excluding the cost of cement), finishing the surface even and smooth without using extra cement complete all as specified and as directed. | 3,200 | Sqm | 120 ₹3,84,000 | 180 ₹5,76,000 | 60 ₹1,92,000 Lowest | 120 ₹3,84,000 | 150 ₹4,80,000 | 100 ₹3,20,000 | 100 ₹3,20,000 | 146 ₹4,67,200 |
| 5.00 | M&L for Providing, cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, using water proofing compound at 3% by weight of cement but excluding the cost of WPC ( water proofing compound should be measured and paid seperately) complete all as specified and as directed. | 5 | Cum | 7,500 ₹37,500 | 4,850 ₹24,250 | 6,000 ₹30,000 | 6,050 ₹30,250 | 4,500 ₹22,500 | 5,000 ₹25,000 | 4,000 ₹20,000 Lowest | 6,000 ₹30,000 |
| 6.00 | M&L for cleaning the roof surface and applying oil bond bitumen primer @ 0.20 kg/sqm providing and laying 4 mm thick APP modified water proofing membrane weight not less than 4 kg/sqm reinforced with non woven polyester mat weighing not less than 160 gm/sqm having soften point not less than 140 degree centigrade tensile strength not less than 800/N/sqm cum tearing strength 180N with minimum of 10 cm side laps and 15cm end laps by application of torch applying a coat of blown grade hot bitumen over the membrane @ 1.2 kg/sqm and providing garnish with solar reflective bitumen aluminium paint @ 0.1 kg/sqm over completed area of membrane complete all as specified and as directed. complete all as directed. | 3,200 | Sqm | 550 ₹17,60,000 | 485 ₹15,52,000 | 420 ₹13,44,000 Lowest | 575 ₹18,40,000 | 600 ₹19,20,000 | 515 ₹16,48,000 | 600 ₹19,20,000 | 590 ₹18,88,000 |
| 7.00 | Supply only integral water proofing compound as per manufactures instruction. | 807.36 | Kg | 45 ₹36,331.2 | 60 ₹48,441.6 | 60 ₹48,441.6 | 75 ₹60,552 | 60 ₹48,441.6 | 25 ₹20,184 Lowest | 85 ₹68,625.6 | 41 ₹33,101.76 |
| 8.00 | Demolition of plain cement cement concrete/terrazo tiles with cement mortor bedding in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removing the debris outside MOD land all as specified by engineer in charge | 25.2 | Cum | 700 ₹17,640 | 350 ₹8,820 | 200 ₹5,040 Lowest | 400 ₹10,080 | 450 ₹11,340 | 600 ₹15,120 | 600 ₹15,120 | 320 ₹8,064 |
| 9.00 | M&L for 40 mm thick PCC 1:2:4 type B-0 (12.5 mm graded aggregate) as in floor all as specified and directed, finishing cement concrete as in floors finished even and smooth without using extra cement and spike rolling to surfaces or making impressions of expanded metal,whilst the concrete is green all as specified and directed | 80 | Sqm | 290 ₹23,200 | 240 ₹19,200 | 240 ₹19,200 | 200 ₹16,000 | 165 ₹13,200 Lowest | 220 ₹17,600 | 350 ₹28,000 | 203 ₹16,240 |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
26 Jan 2026, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
SPECIAL REPAIRS TO ROOF TREATMENT OF CERTAIN MD ACCN AT AFS BEGUMPET UNDER GE (AF) HAKIMPET
2026_MES_747215_1
8893/E8
Open Tender
Civil Works
Item Rate
180 days
Begumpet
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Hakimpet
₹87,200
Yes
17 Mar 2026
5 Jan 2026
28 Jan 2026
5 Jan 2026
26 Jan 2026
19 Jan 2026
Dismantling/removing the textile coverings and cover fillets all as specified
Demolition of plain cement concrete of any description in any position as in padding concrete, sunken slabs coping, benching, kerbs or mud stops etc and removing the debris outside MOD allas psecified by engineer in charge
M&L PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in terrace (padding layer )finished even surface of 25 mm thick complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:3 on concrete roof slabs including mixing water proofing compound at 3% by weight of cement (but excluding the cost of cement), finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for Providing, cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, using water proofing compound at 3% by weight of cement but excluding the cost of WPC ( water proofing compound should be measured and paid seperately) complete all as specified and as directed.
M&L for cleaning the roof surface and applying oil bond bitumen primer @ 0.20 kg/sqm providing and laying 4 mm thick APP modified water proofing membrane weight not less than 4 kg/sqm reinforced with non woven polyester mat weighing not less than 160 gm/sqm having soften point not less than 140 degree centigrade tensile strength not less than 800/N/sqm cum tearing strength 180N with minimum of 10 cm side laps and 15cm end laps by application of torch applying a coat of blown grade hot bitumen over the membrane @ 1.2 kg/sqm and providing garnish with solar reflective bitumen aluminium paint @ 0.1 kg/sqm over completed area of membrane complete all as specified and as directed. complete all as directed.
Supply only integral water proofing compound as per manufactures instruction.
Demolition of plain cement cement concrete/terrazo tiles with cement mortor bedding in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removing the debris outside MOD land all as specified by engineer in charge
M&L for 40 mm thick PCC 1:2:4 type B-0 (12.5 mm graded aggregate) as in floor all as specified and directed, finishing cement concrete as in floors finished even and smooth without using extra cement and spike rolling to surfaces or making impressions of expanded metal,whilst the concrete is green all as specified and directed
M&L Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete,including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq.m, blinded with grit or pea size gravel @0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area
S&F Cement concrete tiles 30cmx 30cm x 22mm thick with grey cement and pigment including 15 mmm thick screed bed or bedding layer in CM 1:6 as in base to floor finish.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight)
Taking down plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L for 15 mm thick plastering on fair faces of brick work or concrete surfaces in two layer with 10 mm thick in CM 1:6 and top 5 mm thick in CM 1:4, mixing water proofing compound at 3% by weight of cement (but excluding the cost of WPC) finished the surfaces even and smooth without using extra cement.
M&L for 10 mm thick plastering in CM 1:3 on fair faces of brick work or concrete surface as in ceiling including finishing the surface even and smooth without using extra cement
M&L for preparing new plastered surface of ceiling and applying 2mm thick putty finish to obtain smooth finish in ceiling surface and applying two coat of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparing new plastered surface of wall surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by the Engineer-in-charge and as per manufacturers instructions
M&L for complete removal of existing treatment of wall and applying 2mm thick putty finish to obtain smooth finish on old wall surface and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M&L for complete removal of existing treatment of ceiling and applying 2mm thick putty finish to obtain smooth finish wall surface and applying two coats of distemper over a coat of primer complete all as specified and as directed.
M&L for complete removal of existing treatment on walls, Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by the Engineer-in-charge and as per manufacturers instructions
M&L for Flush/raised pointing in CM 1:4 to squared rubble masonry, coursed or uncoursed in repairs
M&L for preparing the surface of stone masonary/ concrete surfaces which includes cleaning,sanding and filling any imperfections to create smooth dry base and applying primer to enhance adhesion and durability as per manufactures instructions and applying 2 coats of thin even coats exterior PU magnum/Aqua water proofing coating/ paint using spray gun ,brush or roller allowing each coat to dry completely on old surfaces complete all as specified and as directed by the Engineer-in-charge and as per manufacturers instructions
Demolition of brick work built in CM including All Quions, arches, pillars etc
M & L for Pre-cast cement concrete block masonry with solid blocks, Type C1 1:3:6 (20mm graded aggregate) exc. 10 cm in width and setting in cement mortar 1:4, complete
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 , finished even and smooth without using extra cement
S&F 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including Taking up or down steel tubing and connections including cleaning for refixing or removing to store 15 mm bore
S&F 25 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including Taking up or down steel tubing and connections including cleaning for refixing or removing to store 20 mm bore
Taking up or down steel tubing and connections of 25 mm dia , including cleaning for Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Taking up or down steel tubing and connections of 20 mm dia , including cleaning for Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
S&F Brass elbow 20(3/4 x 1/2)mm dia all as specified and as directed by engineer in charge
S&F Brass tee 20mm dia all as specified and as directed by engineer in charge
S&F Male Brass Threaded Adaptor 20mm dia (MTA/ MBTA) )all as specified and as directed by engineer in charge
S&F Female Brass Threaded Adaptor (FTA/ FBTA) 20mm dia all as specified and as directed by engineer in charge
S&F Tank Adaptor 25mm dia all as specified and as directed by engineer in charge
S&F union of size of 25mm dia all as specified and as directed by engineer in charge
S&F Gun metal gate valves with iron wheel head screwed both ends for iron pipe and fixed 25 mm bore
Dismantling water tank of capacity exc 500 & n.exc 1000 ltrs
Dismantling water tank of capacity exc 250 & n.exc 500 ltrs
S&F 1000 ltrs capacity Rotational moulded polythene water strong tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed
S&F 500 ltrs capacity Rotational moulded polythene water strong tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed
S&F in repairs Ball valves high pressure of PTMT with eppoxy coated Aluminium rod & high density plastic ball screwed for iron pipes and fixed 25 mm bore (Minimum weight 455 gms)
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) of capacity exc 250 ltr but not exc 500 Ltr
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) of capacity exc 500 ltr but not exc 1000 Ltr
Demolition and breaking up of AC/PVC drain pipes 100 mm dia set in CM
S&F PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed to walls bore of the pipe 110 mm in repairs
S&F 110 mm bore PVC (SWR) junction single, (single T) all as specified and as directed
S&F 110 mm bore PVC (SWR) junction single, (single T) with access door all as specified and as directed
S&F 110 mm bore PVC (SWR) bends any radiuis all as specified and as directed
S&F 110 mm bore PVC (SWR) bends with access door any radiuis all as specified and as directed
Demolition of RCC Concrete of any description and in any position not otherwise specifically provided for.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
8893ps.pdf
Tender Documents • 0.64 MB
BOQ_836749.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .