Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹50.7 LAccepted-AOC | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹53.8 L+₹2.8 L (5.53%)Rejected-Finance | 2 | Rejected-Finance Other than lowest | |
| 3 | 3₹55.5 L+₹4.5 L (8.73%)Rejected-Finance | 3 | Rejected-Finance Other than lowest | |
| 4 | 4₹61.1 L+₹10.1 L (19.8%)Rejected-Finance 197 C P COLONY MORAR GWALIOR GWALIOR MADHYA PRADESH 474006 | GWALIOR | MADHYA PRADESH | 474006 | 4 | Rejected-Finance Other than lowest | |
| 5 | 5₹61.1 L+₹10.1 L (19.8%)Rejected-Finance | 5 | Rejected-Finance Other than lowest |
Tender Value
₹70.0 L
EMD Value
₹1.4 L
Closing Date
25 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Gwalior
CWE AF Gwalior 474020
Addn/Altn to No.03 Airmen Mess at AF Stn Gwalior
2021_MES_465684_1
84098/E8
Open Tender
Civil Works - Highways
Item Rate
210 days
GE (AF) AA Gwalior
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE AF AA GWALIOR
₹1.4 L
Yes
7 Dec 2021
6 Aug 2021
4 Oct 2021
6 Aug 2021
25 Sept 2021
14 Sept 2021
60 days
Amount
Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off the AF station premises / MOD land etc complete all as specified and directed.
M&L for Brick work using old size fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
M&L for rendering 15 mm thick in CM(1:6) on fair faces of brick masonry wall / concrete surface finished fair and even without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for etc, including cutting of reinforcement. and similar suspended work (reinforcement cut as required to facilitate demolition) including removal of debris out off the premises / MOD land complete all as specified & directed.
S&F mild steel TMT bars 10 mm dia & over as in reinforcement , cut to length, bent to shape required, including cranking, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia with & including cutting out of old rusted reinforcement & welding etc. complete all as specified and directed.
S&F TMT bars 8mm dia and over , cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for use & waste of form work to soffits of chajja,chullah hoods,troughs and similar including edges for fair finished flat surfaces of concrete complete all as specified and directed.
M & L for reinforced cement concrete M-25 (design mix (using 20 mm graded crushed stone aggregate) as in slab supported on wall and beams coloumns in floor, roofs ,landing, balcaonies & shelves and similar works etc.complete all as specified and directed. Note:- Reinforcement shall be measured and paid separately.
M&L for cement concrete (1:2:4) type B-1 ( using 20 mm graded crushed stone aggregate ) as in coping on chajja, balcony or in roof Kerbs, rounded or chamfered on edges and similar work including necessary formwork complete all as specified and directed.
S&F coloured decorative type earthen Mangalore pattern tiles, interlocking at side joints, as approved by GE, laid over and including 15 mm thick screed bed in CM (1:4) complete all as specified and directed.
Taking down cement plaster of brick or stone masonry etc including raking out joints , hacking for key & scrubbing down with water etc complete all as specified & directed.
M&L for preparation of newly plastered external surfaces of wall including cornices pilasters and apply two coats of exterior emulsion paint of approved brand and shade over one coat of alkali primer all as per manufacturers instructions over and including a layer of wall care putty not less than 2mm thick etc including necessary scaffolding etc complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding complete and removing rubbish off from the premises complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar etc. complete and removing rubbish off from the premises complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) of any mix / grade in ground floor and pavings not exceeding 15cm thickness (below or above ground level) including removal of debris out off the AF station premises / MOD land etc complete all as specified & directed
M & L for 25 mm thick plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in sub floor etc surface finished even and rough to receive the topping etc complete all as specified & directed.
M&L for coloured ceramic floor tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles including over & including 15 mm thick screed bed in CM(1:6) complete all as specified & directed.
M&L for vitrified coloured ceramic floor tiles 10 mm thick (Square/rectangular) area of each tile not exceeding 0.36 Sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles including over & including 15 mm thick screed bed in CM(1:6) complete all as specified & directed.
M&L for 18 to 20 mm thick granite of approved type (table rubbed and pre mirror polished) in window cill, jambs, steps, and cooking platforms and like in cement mortar (1:4) including pointing in coloured cement to match with shade of granite including half moulding of granite exposed edges over & including 20 mm thick screed bed in CM(1:4) for laying of granite slab etc complete all as specifed and as directed.
M&L for machine cut kota stone slab flooring 20mm -22 mm thick of size not less than 575 mm X 575 mm over laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing over & including 20 mm thick screed bed in CM (1:6) complete all as specifed & directed.
M&L for glazed ceramic designed/Digital/Printed coloured tiles 450X300X7 mm thick on vertical surface such as skirting / dado etc set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles ,over & including 10 mm thick backing coat in CM (1:4) etc complete all as specified & directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick or concerete surface / external surface of masonry wall using water proofing compound mixed by weight of cement as per manufacturers instructions surface finished fair & even complete all as specified and directed. (Note: WPC will be measured & paid separately under item No. 1.23 of BOQ )
Supply only integral water proofing compound to incorporate in above item.
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete surface of ceiling finished even and smooth without using extra cement complete all as specified & directed.
M&L for preparation of new plastered or un plastered surfaces of walls and apply two coats of distemper oil emulsion (OBD) over a coat of cement wall primer (from same manufacturer of OBD) over a layer of wall care putty not less than 2mm thick etc complete all as specified and directed.
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces complete and apply two coats of exterior emulsion paint of approved brand and shade over one coat of alkali primer all as per manufacturers instructions over and including a layer of wall care putty not less than 2mm thick etc including necessary scaffolding etc complete all as specified and directed.
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces complete and apply two coats of distemper oil emulsion (OBD) over a coat of cement wall primer (from same manufacturer of OBD) over and including a layer of wall care putty not less than 2mm thick etc complete all as specified and directed.
M&L for preparation of newely plastered surfaces of ceiling and applying three coat of white wash on ceiling complete all as specified & directed.
M&L for preparing old decorated plastered surfaces on ceiling including cornices,pilastered etc. by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and applying two coats of white wash on ceiling complete all as specified and directed. Note: The time difference between one coat and two coat will be decided by Engineering-in-Charge.
M&L for 16 to 18mm thick Dholpur stone (size not exceeding 0.25 sqm ) cladding gang saw cut with machine cut edges, uniform colour of each stone of fixed with and including, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment etc complete all as specified and directed.
M&L for 30 mm thick Dholpur sand base stone 300mm wide , laid over & including 20 mm thick screed bed in CM(1:6) complete all as specified and directed by Eng -in -Charge.
S&F for 25 to 30 mm thick Dholpur sand stone jallies ( size 3' x 2') with cement mortar (1:4), machine cut edge,uniform colour of each stone jallies of fixed in between the post design as approved etc, complete all as specified and directed.
S&F Dholpur sand stone carving post of section not less than 3''x3'' of design as approved by GE of length 0.70m to 1.00m fixed in base stone complete all as specified and directed.
M&L for chequred tiles ( size 20cm x 20cm x 25mm thick) of approved design,coloured & set, jointed and pointed in neat cement slurry mixed with pigment cement to match the shade of tiles as in floors etc laid over & including 20 mm thick screed bed in CM(1:6) complete all as specified & directed.
M & L for Durastone ceramic tiles of size 300mm x 300mm x10mm thick ,set ,jointed and pointed in neat cement slurry, laid over & including 20mm thick screed bed of CM 1:4 etc complete and sepcified and directed.
M&L for PCC (1:4:8) type D-2( using 40 mm graded crushed stone agrregate) as in foundation ,mass concrete and filling etc complete all as specified & directed.
M&L for providing 50 mm thick plain cement concrete 1:2:4 ,type B-1 (using 20mm graded crushed stone aggregates) as in flooring and like and finished even and smooth without using extra cement complete all as specified & directed.
Demolition of plain cement concrete of any mix / grade from roof top in any condition & description including tarfelt and removal of debris out off the AF station premises / MOD land etc complete all as specified and directed .
M & L for brushing neat cement slurry with 3.0 kg of cement per square metre on old concrete surfaces complete all as specified and directed .
M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in roof padding concrete as in leveling course to maintain the true roof slope, finish even & fair without using extra cement, complete all as specified and directed
M & L for 10 mm thick screed bed in cement mortar 1:3 complete mixed with using water proofing compound as per manufacturers instructions (Note:Water proofing compound shall be measured and paid seprerately under Srl item No. 1.23 of "BoQ") over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying one coat of hot blown bitumin grade 85/25 confirming to IS-702 @ 1.20 kg per Sqm over a coat of bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3 mm thick APP modified water proofing membrane weighing not less than 3.50 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (Note:- WPC shall be measured and paid separately)
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with hot mixture of bitumen and clean dry sand 1:1 complete all as specified and directed
Cutting grooves in brick wall, 75 mm wide and 65mm deep and shaping horizontal face of grooves with cement mortar 1:3 complete all as specified and directed.
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware , cutting holes for taking out hold fasts or dismantling brick work & removing from site etc complete all as specified and directed by Engineer-in Charge.
Taking down chowkats or frames with shutters not exceeding 1.50 Sqm each (without taking off shutters from the frames) including builders hardware , cutting holes for taking out hold fasts or dismantling brick work & removing from site etc complete all as specified and directed by Engineer-in Charge.
S&F fabricating of powder coated having minimum thickness of powder coating 50 micron (of approved tint) for door / window/ ventilator frame, shutters & partition including joining cleat glazing clip, aluminium snap beading having minimum weight 100gm/RM rubber neoprene gasket, screws, dash fasteners, rawel plug for fixing of screw in wall or floor etc., aluminium sections as approved by GE for fixing complete all as specified & directed. (Note:- (i) Rubber packing & builders hardware shall be measured & paid separately. (ii) Weight of only aluminium section used for fabrication of door / window/ ventilator frame, shutters & partitionshall be measured for payment.)
S&F powder coated aluminium grill of approved pattern & coating tint to match existing using aluminium section and aperture n.exc 80 mm in & including aluminium powder coated channel, 1 mm thick fixed with stainless steel screw etc complete all as specified & directed.
M&L for Pressed steel frames 105mmx60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, three hinges, lock strike plate etc and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends ,etc complete all as specified and directed.
M&L for Pressed steel frames 165 mm x 60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, three hinges, lock strike plate etc and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends, etc complete all as specified and directed.
S & F factory made Solid PVC door frame of size 50mmx 47mm made out of 5mm thick plain colour PVC sheet reinforced with mild steel square tube, as per manufacturers specification complete all as specified and directed.
S & F Factory made solid panel PVC door shutter with both sides prelaminated PVC sheet 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification.
All as per ser item No-1.51 here-in -before but partly glazed i.e. upper panel will be wire gauzed panel fitted externally in the clean space & lower panel will be both side prelaminated sheet etc, complete all as specified.
S&F aluminium, anodised barrel tower bolts of extruded section and fixed 200 mm long complete all as specified & directed.
S&F powder coated aluminium handle 150 mm long complete all as specified & directed.
S&F double action floor spring hydraulically regualted made up of aluminium 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty etc, complete all as specified and directed.
Supply only 6.3 mm thick sheet glass ordinary quality frosted on one side for aluminium doors and fully glass partition in squares exceeding 0.50 Sqm in each pane etc,complete all as specified.
Supply only 4.8 mm thick sheet glass ordinary quality for aluminium windows/ventilator in squares exceeding 0.50 Sqm in each pane complete all as specified.
Supply only 4 mm thick sheet glass ordinary quality for aluminium windows/ventilator in squares not exceeding 0.50 Sqm in each pane complete all as specified.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples etc complete all as specified & directed.
S&F Aluminium body door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed etc complete all as specified & directed.
S&F mortice lock two levers (Harrison) vertical type, size 100mm complete all as specified & directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections etc complete all as specified & directed.
S & F mild steel 300 mm , ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed.
S&F 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type C-21 etc,complete all as specified and directed.
S&F in repair 18mm thick ply of grade 1 quality (celuka)of one side prelam of approved colour and one side white colour fixed with screwes ,solvent cement /adhesive to make kitchen cabinate and CBs shutters complete all as specified and directed.
S&F 100 mm size MS medium weight butt hinge colled rolled complete all as specified & as directed.
S&F in repair coloured powder coated drapery rod of aluminium 25mm inner dia with supports on coloured powder coated aluminium decorative type designed and pattern approved by GE including decorative brackets both ends complete both ends with holder/bracket etc, all as specified and directed by Engr-in- Charge.
S&F rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed type),white colour double layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI medium grade over flow ( 600 mm long) and wash out pipe (450 mm long )with plug & fittings including dismanling of existing tank and lowering down etc complete all as specified and directed.
S&F in repair gun metal globe or gate valves(ISI MARK), with iron wheel head, screwed both ends for iron pipe 20 mm bore complete all as specified and directed.
S&F in repair 20 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified & as directed.
Taking up or down steel tubing and connections 15 mm bore, including cleaning of serviceable tubing for reuse complete all as specifed & directed.
Taking up or down steel tubing and connections 20 mm bore, including cleaning of serviceable tubing for reuse complete all as specifed & directed.
Taking up or down steel tubing and connections 25 mm bore, including cleaning of serviceable tubing for reuse complete all as specifed & directed.
Fixing only existing serviceable steel tubing and connections 15 mm bore, in same or different position (walls, ceiling, floors, etc) including additional fitting complete all as specified & directed.(Note: Old GI pipes retrived from Sl No. 1..73 here-in-above.)
Fixing only existing serviceable steel tubing and connections 20 mm bore, in same or different position (walls, ceiling, floors, etc) including additional fitting complete all as specified & directed.(Note: Old GI pipes retrived from Sl No. 1.74 here-in-above.)
Fixing only existing serviceable steel tubing and connections 25mm bore, in same or different position (walls, ceiling, floors, etc) including additional fitting complete all as specified & directed.(Note: Old GI pipes retrived from Sl No. 1.75 here-in-above.)
M&L for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors complete all as specifed & directed.
M&L for GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors complete all as specifed & directed.
M&L for GI water tubing medium grade, ISI marked, galvanised, 25 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors complete all as specifed & directed.
S&F in repair Counter top vitreous China wash basin of size 550x400mm including 32mm dia brass waste coupling ,fittings and waste pipe etc, & fixing of tap etc.complete all as specified and directed. Note :- Pillar tap shall be measured & paid seperately as supply only under respective item of BoQ".
S&F PVC connection 15mm size with PTMT nuts of lengh 450mm complete all as specified.
S&F in repairs 32mm dia PVC waste pipe all as specified and directed.
Supply only pillar tap cast copper alloy with capstin heads chromimium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shank and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and directed.
S&F 32mm bore dia of discharge pipe waste coupling PTMT (half or full threatened) (Min weight 45 gms complete all as specified and directed
S&F in repairs WC squatting pan " Orissa Pattern" of size 580 X 440 mm white with integral foot rest including cast iron P or S trap, front or back inlet and making connection to trap & to flushing cistern ,concrete bedding & fittings etc complete all as specifed & directed.
S&F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set all as specified and directed.
S&F in repair aluminium tubular towel rail , 20mm dia, D type, 60cm long between flanges fixed with rawl plug complete all as specified and directed.
S& F in repairs Vitreous China urinals, flat back size 390 mm x 375 mm x 590 mm white minimum with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, complete all as specified and as directed.(Make:CAT Part No 5004 of CERA or other equivalent make as approved.)
S&F in repairs brass chromium plated shower rose with swivel joints, 75 mm size in square with CP long shank arm including fixing to steel pipe or union of 15 mm bore complete all as specifed & as directed.
S&F in repair 15 mm bore bib taps, cast copper alloy with capstan head, chromium plated fancy type with long body shank, screwed down with high pressure screwed for iron pipe and fixed complete all as specified & directed.
S&F in repair concealed stop cock fancy type CP with long shank cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both end of size 15 mm bore complete all as specified and directed.
S&F in repair 75 mm cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 1:2:4 (using 20 mm graded crushed stone aggregate) complete all as specified & directed.
Cutting out embedded portion of hold fast or lugs exceeding Half brick but not exceeding one brick built in cement mortar & inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified & directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified & directed.
M&L for PCC (1:3:6) type C-2( using 40 mm graded crushed stone agrregate) as in foundation ,mass concrete and filling etc complete all as specified & directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified & directed.
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified & directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick / concrete surface finished fair & even complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil for Path & hardstanding etc complete all as specified & directed.
M&L hardcore of gauge not exceeding 63mm broken stone , deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface etc,complete all as specified & directed.
M&L for 100 mm thick Plain Cement Concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) and finishing the surface even and smooth without using extra cement as in flooring/hard standing/paving complete all as specified and as directed
M&L for 80 mm thick approved factory made machine pressed precast concrete interlocking paver block of any size & shape conforming to IS:15658-2006 of compressive strength not less than 400 Kg/sq.cm (M-40) including laying over & including 50 mm thick sand cushion(filling) and joints filled with sand etc complete all as specified and directed. NOTE : Manufacturer’s test certificate of Interlocking paver block shall be produced on each/every lots before making payment.
M&L Forming contraction (Dummy) joints 100 mm deep x 10 mm wide, filled with using sealing compound of grade -A complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable etc. all as specified and directed.
Removing excavated material to a distance exceeding 1.5 Km but not .exceeding 5 Km and deposited where directed and all as specified .
Returning filling in including, spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil all as specified and directed .
M&L for POP ceiling by 15mm thick plaster of paris finishing 10mm thick lathing and 5mm thick finishing on ceiling,0.56 thick nominal dia and aperture 1.18mm of wire mesh including dome or one step inside the ceiling design approved by the GE on GI frame work of grid size 605X605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermidiate channel 0.9mm thick having two equal flanges of 15mm each and and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.20m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermidiate channel with connecting clips across the intermidiate channel at 457mm centre to centre including hangers 6mm dia. GI (up to 1200mm length) adusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long with and including two coats of plastic emulsion paint over a coat of primer complete all as specified.
KITCHEN COMMERCIAL CHIMNEY S &F stainless steel kitchen commercial Chimney fabricated out of stainless steel sheet 0.6 mm thick 24 gauage with the following specification :- (i) Base area of the chimney exc 1.80 Sqm but n.exc 2.40 Sqm in single /double attachable arrangement to suit the site requirement with sides sheeting of the same material not less than 0.25 mm avg height. (ii) Removable filters ( 3 to 4 Nos) of the same sheet and thickness to take the smoke discharge and passing it to main duct .(iii) Connecting ducts fabricated out of PGI sheet 0.6 mm thick with cross sectional 0.25 x 0.40 M area of suitable size and connected to main duct of Chimney with nut and bolts = 03 Nos. (iv) Main duct for the Chimney fabricated out of 0.6 mm thick PGI sheet with cross sectional area 0.40 x 0.40M of length appx 4.50 to 5.00 m to take the smoke discharge from connecting duct to the outer duct. The connecting duct and main ducts are to be secured with walls /ceiling with necessary arrangements of MS work. (v) Outer duct for the Chimney fabricated out of 0.6 mm thick PGI sheet with cross sectional area 0.30 x 0.30 M starting from main duct of length appx 5.00 M. The duct is to be secured with wall / terrace with necessary MS frame work arrangement. Note :- All the joints of the ducts are to be made seamless/smoke leak proof by jointing them with MS nut bolts not less not 5 mm dia and 8 mm thick compressible foam based gasket.
Taking down carefully unserveciable/damaged copper/aluminium surface (batten/conduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators light fittings etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
M&L for Point wiring using FR PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FR PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar (1:4) and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point etc complete all as specified and directed. (Note : Switch/bell push/fan regulator etc shall be measured and paid separately)
All as per Srl item No. 2.19 above but for 5 pin 5 Amp socket outlet point on independent board controlled by one switch 5/6 Amp, one way, etc complete all as specified and directed.
All as per Srl item No. 2.19 above but for 5 Pin 5 Amp socket outlet point controlled by one switch 5 Amps one way on same board, etc complete all as specified and directed.
All as per Srl item No. 2.19 above but for one 15 Amp socket outlet point concealed using 2.5 Sqmm FR PVC insulated multi-strand copper conductor wire including 2.5 Sqmm FR PVC insulated unsheathed copper conductor earth wire and making good to disturbed surfaces of wall / ceiling to match existing finishes etc complete all as specified and directed.
S&F switch piano, flush type, single pole, one way 5 amps 230 volt AC ISI marked complete all as specified and directed.
Fixing only switch piano, 5 Amp, single pole flush type , AC 230 Volts complete all as specified and directed. (Note:- Existing switch retrieved in serviceable condition during taking down of point wiring shall be used.)
S&F socket outlet 2 in 1, five pin, 5 /6 Amps flush type, white / ivory finish 230 volts AC ISI marked complete all as specified and directed.
S&F switch socket outlet combinaton multipurpose, five pin, 5 Amps flush type with indicator, 230 volts AC ISI marked complete all as specified and directed.
Fixing only switch socket outlet combination multipurpose, five pin, 5 /6Amps flush type, 230 volts AC circuit ISI marked complete all as specified and directed.(Note:- Existing switch socket combination retrieved in serviceable condition during taking down of point wiring shall be used.)
S&F socket outlet combinaton multipurpose, six pin, 6/15 Amps flush type with indicator, 230 volts AC ISI marked complete all as specified and directed.
Fixing only switch socket outlet combination multipurpose, five pin, 6 /15 Amps flush type, 230 volts AC circuit ISI marked complete all as specified and directed.(Note:- Existing switch socket combination retrieved in serviceable condition during taking down of point wiring shall be used.)
S&F ceiling rose, surface bakelite 50 mm X 18 mm AC, 230 V polycorbonate isolated body , two or three terminals complete all as specified and directed.
Fixing only ceiling rose, surface bakelite , two or three terminals complete all as specified and directed. (Note:- Existing ceiling rose retrived in serviceable condition during taking down of point wiring shall be used)
S&F lamp holder PVC/Polycorbonate type with cord grip cap/back plate suitable for batten/angle /pendent fitting complete all as specified and directed.
S&F fan regulator electronic, step type hum free, socket type , suitable for ceiling fans of any capacity, pre wired 230 volts AC 50 HZ supply 100/120 Watt complete all as specified & as directed
Supply & Fix for decorative slim linear LED tube light fitting 01x20 watt light with co extruded polycarbonate body, environmental frendly, energy efficient ready to use pack with all accessories including 01 No 20 watt tube rod and connecting the same to ceiling rose with using copper conductor 50/0.020 flexible PVC sheathed and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified & directed by Engineer in-charge Make-Havell's Cat Part No LUMILINEBS20WLED 865SPCWH / Surya Cat No -SLEBT -20 /CG cat No -LCTL 18 CDL
S&F LED mirror light complete with lamp all as specified and directed by Engr - in Charge. Make : Havells Cat part No LUMILNEBS9WLED865SPCWH/Surya Cat part No -SLE-BT-10/ CG Cat part No -LCTL-9 CDL
Disconnecting & taking up or down existing unserviceable MCB, DB VTPM of any description and in any position with existing fittings (MCB's) complete all as specified & as directed. Note:- Existing MCB in serviceable condition shall be taken out carefully for reuse in the work.
Supply and Fixing for sheet metal enclosure for DB’s 4 way 240 volts double door with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
All as per item No 2.37 above but DB’s 8 way double- ditto-
Supply and fixing factory made epoxy powder coated distribution board TP & N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TPN-MCCB 100 /125 Amps as incomer and 12 SP MCBs (or any combination of SP/TP MCBs )outgoings incl taking out VTPN MCB DB complete all as specified & directed
S&F MCB SP 6 to 32 Amps ('B' Series) having current rating 10 KA complete all as specifed and as directed .
S&F MCB SP & N, 40 Amps ('B' Series) having current rating 10 KA complete all as specifed and as directed .
S&F MCB TPN 63 Amps ('B' series) having current rating 10 KA including making electrical incoming/out going connectins with lugs/thimbles all as specifedand directed.
Supplying & fixing MCCB, 3 pole, 125 Amps, 50Hz, 415 Volts with rupturing capacity 35/36 KA with thermal magnetic release and adjustable overload setting having type DPX 125 conforming to IEC-609472 & IS-139473 to be fixed in distribution board, complete all as specified & directed
M&L for sub main wiring using three single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating upto and including 1100 Volts drawn in and including surface PVC conduit med grade of dia not less than 25mm with standard accessories, along-with two run of PVC (black & green colour) insulated , unsheathed, stranded copper conductor of size 6.0 Sqmm as neutral & earth continuity conductor including taking down of existing sub main wiring complete all as specified and directed.(NOTE : Three run of single core PVC cable with two run of neutral & earth conductor and conduit shall be measured as one unit.) .
M&L for Sub main wiring in existing Surface/conceled conduit with two single core FR PVC insulated and unsheathed copper stranded conductor of size 6 Sqmm 1100 Volts and one run of copper stranded conductor of size 6.0 Sqmm for continuous earthing including connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor including taking down of existing sub main wiring complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of rating 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable size of MS strip, nuts, bolt and washer including taking down existing two pin and earth plug and socket complete complete all as specified and as directed.
Taking down carefully from existing place for ceiling fan/ Ext fan and shifting to MES store yard Scraping,cleaning & painting with two coats of super enamelled paints (as approved by GE) greasing/oiling and refixing at site complete incl electric connection with three core flxible wire 1.5 sqmm all as specified and directed by Engineer-in-Charge.
Taking down carefully from existing place for re use geyser by disconnecting elect /water supply connection and refixing the same after after civil work including all elect /water supply connection connecting with suitable wire all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, 50 mm thick pre -cast RCC cover (1:2:4) type B-1, with 8 mm dia TMT bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 15 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing complete all as specified & directed.
S&F in replacement 36W LED recess softline luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal. Fixture size 595x595x70mm complete with LED tube with driver and all accessories specified and directed by Engr -in- Charge. Make : Havells cat part No PLUTONEO2X2PLR34WLED840S/Surya Cat No- SLEDS36R22/ CG Cat Part No -LCTLSN36- CDL.
Supply and fixing LED porch light IP55 surface mounted led porch light in engineering plastic housing with clear prismatic diffuser 6w LED complete with lamp etc and all accessories pre wired and incl. connecting up with twin core twisted flexible copper conductor cable with suitable size. upto the ceiling rose all as directed by Engineer-in-Charge .Make: C & S Cat Part No CG80B6WLED or equivalent of /Surya Cat No - SLEDLS6WXXStellar round/ CG cat Part no -LCSR-06-CDL
Supply and fixing Street light fittings LED 15W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) with complete (40 mm GI pipe light grade ),clamp,nut-bolt and washers all directed by Engineer-in-Charge. Make;Havells Cat part No - ENDURAPEARLSL 15WLED757SASYTOPC /Surya Cat Part No -SLRUL 15W IP 66LXN/CG cart part No -LSTS-15CDL.
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed
Supply & spreading in trenches clean dry sand including gently punning around cable, etc complete all as specified and directed. (Note: Punned thickness shall be measured)
Supply and laying fly ash bricks, old size , laid over sand cushioning as cable protection in trenches keeping width of brick parallel to the edge of cable complete all as specified & directed.
Supply and Laying 80 mm bore light grade ISI marked G.I. tubing laid in trenches or fixed on wall for cable protection including fixing with MS clamp and nut bolts complete & including disconnecting and taking down of old corroded GI pipe all as specified & as directed.
Supply and laying , connecting and testing of LT cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty) 1100 volts grade ISI marked with aluminium stranded conductor of 50 Sqmm , 4.0 core including taking down existing LT cable of any type & any size complete all as specified and directed.
Supply, Install,Testing and commissioning of roof top 10 KW Solar Power Plant consisting of PV modules inverter ,DC cables,AC cable , connectors,, earthing,switch gears with structure complete all as specified & directed.
Achal Construction
M/S LAKSHYA CONSTRUCTIONS
RAVINDRA SALES
m/s vikash Engineers
lodhi builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .