Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹118.8 CrAccepted-AOC | ₹118.8 Cr | L1 | Accepted-AOC Low |
| 2 | L2₹142.7 CrRejected-Finance | ₹142.7 Cr | L2 | Rejected-Finance High |
Tender Value
₹118.8 Cr
EMD Value
₹59.4 L
Closing Date
13 Jun 2024, 5:00 pmClosed
Chief Executive officer MMB
Maharashtra Maritime Board Mumbai
Development of Fisheries Harbour at Sakharinate Tal. Rajapur Dist. Ratnagiri.
2024_MMB_1036629_1
MMB/CEO/ENGG/Rtn/23-24/253
Open Tender
Civil Works
Sakharinate
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
₹59.4 L
Maharashtra Maritime Board Mumbai
17 Oct 2024
16 Mar 2024
18 Jun 2024
16 Mar 2024
13 Jun 2024
5 Jun 2024
16 Mar 2024 - 27 Mar 2024
27 Mar 2024
Amount
Part A :- Civil Work (MEP Work)
Supplying & laying trap stones upto 20 kg for Filter / Core layer including conveying with all leads, lifts, laying in required lines, level, slope as per drawing including necessary equipments & machinery as directed by, etc. complete in tidal conditions.
Supplying and laying trap stone weighing 20 to 50 kilogram for Core / Sub armour layer including conveying with all the leads, lifts, laying in required lines, level, slope as per drawing including necessary equipments and machinery as directed by etc. complete in tidal conditions.
Supplying & laying trap stone weighing 50 to 100 kg for Core / Sub armour / Armour layer including conveying with all leads, lifts, laying in required lines, level, slope as per drawing including necessary equipments & machinery as directed by, etc. complete in tidal conditions.
Supplying and spreading geofabric filter layer of Geotextile of Polypropylene multifilament woven to the line, level and grade with pore size less than 0.075 mm and permeability greater than 9.0 litre/ One Square Metre/second confirming specification IS:1969 and ASTM standard including conveying to the site, joining and stitching with proper overlap and laying at excavated surface in tidal condition as directed by Engineer in- Charge etc. complete.
Providing Temporary Gantry platform using structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections with connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. The item includes all trasnporation, fabricting all materials, labour,required number of dummy piles for erection of gantry over shore and equipment required for driving and casting of reinforced cement concrete piles including dismanatling platform and dummy piles etc. after completion of work and demobilization from site with all materials and proper cleaning etc complete. Payment Terms 1. 20% on erection of grantry 2. 40% on completion on 50% of scope (Pile) 3. 30% on another 50% completion of complete scope of piling 4. 10% demolition & demobilization of grantry. Note:- The Contractor Should design the gantry as per site condition & get it proof checked from expert agencies like IIT/VJTI etc. before actual execution. Approval to the design shall be obtained from Maharashtra Maritime Board
Providing and laying cast in situ / ready mix M40 RCC for 900 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand (depth 0 to 5 metre)
0 to 5 m Depth
5 to 10m Depth
10 to 15 m Depth
15 to 20 m Depth
Extra for Chiselling in hard rocks including removing and stacking the loose material and disposing the unserviceable materials as directed etc. complete. 900 mm dia
Providing bentonite slurry process for various diameter o piles vide Item Nos1 (itoxxiv) above
Providing and laying in situ M40 controlled cement concrete of trap metal for RCC work in main/ cross girders, diaphrams etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc. complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with natural sand)
Providing and laying in situ M40 controlled cement concrete of trap/ granite/ quartzite/ gneiss metal for RCC work in solid/ deck slab etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc. complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with natural sand)
Providing and laying cement concrete wearing coat M40 grade with batch mix type / concrete mixer with SCADA including reinforcement as per drawings and technical specifications etc. complete with fine agreegates of required specifications ( VSI sand finely washed etc )
Providing and filling sand in foundation trenches / below Raft as per drawing and technical specifications etc. complete. (Coarse Sand and Gravel )
Removing sand/ muck/ slush/ soil bellow low tide level to the specified section from navigation channel as per the area and depth up to 3.00 m from sea bed by mechanicel means with, hyderaulic excavator, etc. and barge for establisment all machinery with all required tools and equipments, boat for conveying excaveted material, including removing the excavated materials with all lift and leads as directed beyond high tide level line of water stacking spreading or disposing, dewatering if required unless otherwise provided else where complete under tidal condition.
Removing sub-marine rock below low tide level to the specified section from navigation channel as per the area and depth mentioned on the drawing by mechanicel means with poclain, hydraulic excavator, rockbreaker etc. and barge for establisment all machinery with all required tool tool sand equipments, boat for conveying excavetd material, including removing the excavated materials with all lift and leads as directed beyond high tide level line of water stacking spreading or disposing, dewatering if required unless otherwise provided alse where complete under tidal condition.
Providing earth work in embankment with approved materals obtained from departmental land upto lead of 50 m, laying in layers of 20 to 30 cm thickness, breaking clods, dressing to required lines, curves, grade & section, watering & compaction with vibratory roller to achive not less than 97% of Standard Proctor Test complete. (Material from departmental Land)
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 m, laying in layers of 20 to 30 cm thickness, breaking clods, dressing to required lines, curves, grade & section, watering & compaction with vibratory roller with V_Sat attachment to achive not less than 97% of Standard Proctor Test complete. (Material from Other sources)
Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing rubble filling of trap stones for foundations includingfilling voids with sand/grit and compaction etc complete.
Providing rubble filling of trap stones for foundations includingfilling voids with sand/grit and compaction etc complete.
Providing & laying Cast in situ / Ready Mix C.C. M-20 of trap metal for bed blocks, foundation blocks & such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven & honeycombed surface & curing, etc. complete. The C.M. 1:3 plaster is considered for rendering uneven & honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, etc. (Wooden centering will not be allowed.)with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade ).
Providing & laying M-30 P.C.C. of trap metal for cast in citu piers, abutment, returns, wings, etc. including provision of "V" shaped false joints to form suitable panels on faces to approve design with compacting by vibrating & curing complete, including plywood / steel form work centering (excluding dewatering by means of pump) & including bailling out water & curing finishing in C.M. 1:3 etc. complete. fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ..
Providing & laying M-30 C.C. of trap metal for cast in citu R.C.C. solid piers, column, etc . including provision of V shaped false joints to form suitable panels on faces of approved design with compacting by vibrating & curing complete. Including plywood / steel formwork, centering (excluding dewatering by means of pump) & including bailling out water & including fi nishing C.M. 1:3, curing complete. with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc.)..
Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete.
Providing and laying of reinforced cement concrete in M-30 grade approach slab / Rigid Pavement including formwork complete with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) as per drawings and technical specifications etc. complete with fine agreegates of required specifications ( VSI sand finely washed etc ) ( excluding reinforcement )
Empty boring for 425 to 500 mm dia. bored R.C.C. cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Spec :(As directed by Engineer in Charge)
Empty boring for 725 to 1050 mm dia. bored R.C.C. cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Spec :(As directed by Engineer in Charge)
Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C. Piles upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom including fabricating cutting the mild steel sheet to required diameter and shape ,welding the joints and driving with the help of required machineries including all materials labours and lifts etc. complete as directed by the Engineer in charge. Upto 3.00 meter deep liner
Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C. Piles upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom including fabricating cutting the mild steel sheet to required diameter and shape ,welding the joints and driving with the help of required machineries including all materials labours and lifts etc. complete as directed by the Engineer in charge. Spec :(As directed by Engineer in Charge From 3.00 to 9.50 meter deep liner
Providing & laying cast in situ / ready mix M-30 R.C.C. for 450 mm dia bored piles each of load capacity as per design & of specified dia of as directed, placed through steel shell sunk to required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete & withdrawal of steel shell with fully automatic micro processor based Programmable Logic Control with Supervisory Control & Data Acquisition enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ).
Chipping and dressing of the R.C.C. piles upto 0.60 meterincluding cleaning reinforcement and removal of dismantled materials upto a distance of 50 meter beyond the building area etc. for providing pile caps.Spec :(As directed by Engineer in Charge
Carrying out load test for 1.5 times the proposed safe working load on the pile indriven position above 400 mm and upto to 550 mm diameter including construction of test cap, use of accessories and instruments including providing graphs as per I.S. code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete.
Carrying out load test for 1.5 times the proposed safe working load on the pile in driven position above 550 mm and upto 650 mm diameter including construction of test cap, use of accessories and instruments including providing graphs as per I.S. code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
Providing dry rubble stone soling 15 cm to 20 cmb thick including hand packing and compacting etc. complete.
Providing & laying Cast in situ / Ready Mix C.C. M-20 of trap metal for bed blocks, foundation blocks & such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven & honeycombed surface & curing, etc. complete. The C.M. 1:3 plaster is considered for rendering uneven & honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, etc. (Wooden centering will not be allowed.)with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade ).
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
Filling in plinth and floors with approved excavated material in 15cm. to 20cm.Layers including watering and compacting etc. complete
Providing & laying in situ M-25 C.C. of trap / granite / quartzite / gneiss metal with 15% plum of trap stones for retaining walls & jetty, etc. including necessary formwork, compacting, curing, bailing out water manually in tidal range, etc. complete.
Providing & laying Cast in situ / Ready Mix C.C. M-30 of trap metal for R.C.C. work in foundations like raft, strip foundations, grillage & footings of R.C.C. columns & steel stanchions, etc. ncluding Steel centering form work, cover block laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finishis to be provided and curingetc.complete. (Excluding reinforcement & structural steel), etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc).
Providing & laying cast in situ / Ready Mix cement conrete M-30 of trap metal for R.C.C. columns as per detailed designs & drawing or as directed, including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finishis to be provided and curingetc.complete,. (Excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand.
Providing & laying cast in situ / Ready Mix C.C. M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams & lintels as per detailed designs & drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction & roughening surface if special finish is to be provided & curing complete. (Excluding reinforcement & structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc).
Providing & laying cast in situ / Ready Mix C.C. M-30 of trap metal for R.C.C. slabs & landings as per detailed designs & drawings including steel centering, formwork, cover blocks,laying/pumping, compaction, finishing formed surfaces with C.M. 1:3 of sufficient min. thickness to give smooth & even surface or roughening surface if special finish is to be provided & curing, etc. complete. (Excluding reinforcement & structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc).
Providing and laying Cast in situ/Ready Mixcement concrete M-30 of trap metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providingg Laterite stone masonry in cement mortar 1:6 in foundation and plinth including racking out joints when plastering is to be done/striking joints when no plastering is to be done watering and scaffolding
Providing Laterite stone masonry in cement mortar 1:6 in Superstructure including racking out joints when plastering is to be done/striking joints when no plastering is to be done watering and scaffolding.
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
Providing & laying polished hand cut Kotah stone flooring 25 to 30 mm thick and 45 cm to 55 cm width in plain / diamond pattern on bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing & cleaning etc. complete..
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete.
Providing & laying vitrified mirror / glossy finish tiles decorative type having size 590 to 605 X 590 to 605 mm of 8 to 10 mm thick & confirming to IS 15622-2006 (Group BIa) of approved make, shade & pattern for flooring in required position laid on bed of 1:4 C.M. including neat cement float, filling joints, curing & cleaning etc. complete.
Providing & laying vitrified mirror / glossy finish tiles having size 590 to 605 X 590 to 605 mm of 8 to 10 mm thick & confirming to IS 15622-2006 (Group BIa) of approved make, shade & pattern for flooring in required position laid on bed of 1:4 C.M. including neat cement float, filling joints, curing & cleaning etc. complete.
Providing and fixing frame with / without ventilator of size as specified with Country non teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete.
roviding and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm
Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete.
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etccomplete.
Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete
Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Meter. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Meter.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running Meter. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Meter. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running Meter. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running Meter. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box
Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete. Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered. a) Colour anodized
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc.
Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete.
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l).plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent.Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
Providing and applying priming coat over new wood and wood based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting, scaffolding etc. complete.
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.
Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing ISI 1729/2002 grade 100 mm dia Cast Iron Soil Pipes With lugs including plug bend necessary fittings such as bends, tees, single junction, double junction, slotted vent, offsets on wall or into the ground including filling joints with cement mortar 1:2 proportion fixing on wall by means of galvanised Mild Steel bracket of 30 x 5 mm plate and 8 mm square rod with Galvanised Iron clamp with washer as per design, drawing and as directed to keep pipe 50 mm away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of white oil paint including removing the existing pipe if necessary and conveying and stacking in PWD Chowky or as directed by Engineer-in-Charge.
Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use)
Providing and fixing white glazed earthenware Wash Hand Basin of 63cm x 45cm size including Bib cock stop tap brass heavy 15mm, brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.
Providing and fixing 10 cm PVC nahani trap with grating etc. complete.
Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying)
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres
Providing cement based W.P. treatment to terraces with B.B.s laid in required slope to drain water for any span after cleaning base surface. Applying coat of cement slurry admixed with W.P. compound & laying B.B.s on bottom layer in C.M. 1:5 admixed with W.P. compound filling up to half depth of B.B.s, curing this layer for 3 days, applying cement slurry over this layer joints of B.B.s with C.M. 1:3 admixed with W.P. compound & finally top finishing with average 20 mm thick layers of same mortar added with jute fiber at 1 kg per bag including finishing surface smooth with cement slurry admixed with W.P. compound. Marking finished surface with false squares of 300 X 300 mm, making junctions at parapet rounded & tapered top for required height, with drip mould at junction of plaster & parapet & curing & covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test, etc. complete..
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M.1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram.per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete
Providing and fixing mild steel grill railing 20 Kilogram/sq.m with teak wood hand rail of size 75mm x 60 mm.and sill of 75mm.x 25 mm.and newel posts for staircases, including fabricating, fix-tures, erecting, painting the grill work with one coat of anti corrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete.
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mild steel plated, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two. coats of oil painting approved quality and shade etc. complete.
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt.total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min.fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc.complete. (weight of profile 4.52 Kilogram/ One Square Metre)
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidngcoupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.
Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete
Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed.
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats.
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing water proofing treatment as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete Terrace slab with bitumen felts in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 One Square Metre., hot bitumen layer at the rate of 14.50Kilogramper 10 One Square Metre. and over the same layer of bitumen felt of type III grade (I) as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50Kilogramper 10 Square Metre. and finally spreading over it grit at the rate of 14.50Kilogramper 10 Square Metre. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete
Providing & fixing machine cut mirror polished 18 to 20 mm thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone partition with rounding / moulding edegs etc. complete. - both side polish.
Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete.
Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement includingr lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall
Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered.
Providing and fixing lifting device
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)
Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 50 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both side, fixing in cement mortar 1:3 and curing etc. complete
Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Laying and spreading available soil in the sub-grade on a prepared surface, pulverizing, mixing the spread soil in place with rotavator with 3 per cent slaked lime having minimum content of 70 per cent of CaO, grading with motor grader and compacting with the road roller at OMC to the desired density to form a layer of improved sub grade.
Construction of G.S.B. by providing close graded material, mixing in mechanical mix plant at OMC, carraige of mixed material to work site, spreading in uniform layers with motor grader on prepared surface & compacting with vibratory roller to achieve desired density, complete as per clause 401. - Plant Mix Method & grading - I material.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mm Aggregate)
Providing and applying tack coat on the prepared surface heating by flames in Boiler and spraying bitumen with sprayer on Concrete surface treated with primer @ 3.25 kg/10 sqm (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and constructing 50 mm. thick Modified Penetration Macadam (MPM) road surface including all mataerials, preparing the existing road surface, spreading 40mm. stone metal layers 100% crusher broken metal with conical crusher plant heating and spraying the bitumen of specified grade @ 1.75 kg/sqm, spreading 12mm.size chips compacting with static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing WBM surface.(VG-30 bulk bitumen rates are considered to arrive at rates)
DENSE BITUMINOUS MACADAM: Proving and laying dense bituminous macadam using crushed aggregates of Grading 1, premixed with bituminous binder of specified grade of Bitumen @ 4.50 per cent by weight of total mix and filler, transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired density for 76-100 mm compacted thickness .USING Batch mix type hot mix plant with SCADA, Sensor Paver, Vibratory roller with Stone Dust filler.(VG-30 bulk bitumen rates are considered to arrive at rates)
BITUMINOUS CONCRETE:- Providing and laying bituminous concrete using crushed aggregates of grading 1, premixed with bituminous binder @ 5.20 per cent by weight of total mix and filler, transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction for 50 mm compacted thickness with specified grade of Bitumen,Excluding prime / tack coat. For Bitumen of specified grade -- USING Batch mix type hot mix plant with SCADA, Sensor Paver, Vibratory roller with Stone Dust filler. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing bituminous Type A liquid seal coat on bituminous surface including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 KgSqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of 4 mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded.Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor /convert or issued for field performance including the screen printed area sand cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor /supplier.
Fixing in position Road Junction/ Informatory Sign Board in ground with C.C.1:4:8 block of 60cm x 60cm x 75cm size including all leads complete.
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
Providing and laying cement concrete pipe of IS 458:2003 NP-3 class of 900mm diameter in proper line, level and slope etc. complete.
Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb with gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant
Construction of D.L.C.C. sub-base over prepared sub-grade with coarse & fine aggregate (VSI grade finely washed crushed sand) conforming to IS : 383, size of coarse aggregate not exceeding 25 mm, cement content not to be less than 150 kg/cum, OMC to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in batching plant / weigh batch mixer, transported to site, laid with paver with electronic sensor / by suitable means as approved by Engineer in-charge, compacting with vibratory roller, finishing, curing & including preparation of sub-grade surface if required, etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer.
Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
Providing and fixing in position TMT FE 500, 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.
Providing & fixing factory made hydraulically pressed mechanically vibrated & compacted precast inter locking C.C. paving blocks 80 mm thick in M-40 grade for City streets, small / medium market roads, low volume roads, utility cuts on arterial roads, etc. as specified & as per IS : 15658 - 2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading & stacking, laying paving blocks over prepared bed of VSI crushed sand of 50 mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over prepared bed, compacting blocks by plate vibrator, etc. complete.
Providing & casting in situ / ready mix P.C.C. M-20 grade of trap metal for coping to head walls / parapet including centering, form work, compaction & curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ).
Providing & erecting 1.5 m high wire fencing with seven rows of barbed wire supported on M.S. angles 50 X 50 X 6 mm at 2.5 m, c/c including excavating pits for foundation, fixing post in C.C. 1:4:8 of size 45 X 45 X 45 cm fastening wire & painting M.S. Angles with 1 coat of red lead primer & two coats of painting etc. complete..
Providing & fixing M.S. grill gate with angle iron frame 65 X 65 X 10 mm with iron bars at 150 mm. cement to cement & diagonal flats as per detailed drawing including hinges, pivot blocks locking arrangement, welding riveting & oil painting of 3 coats of approved shade. Weight of gate 35 Kg/smt.
Providing and fixing stainless steel bollard of steel pipe 1.00 metre long of 250 mm inner diameter and circular top plate of 350 mm diameter with 5 mm thickness on deck of jetty in cement concrete including necessary fixtures and fastening etc. complete. (Stainless steel of grade S-304)
Providing vent holes 100mm diameter GI pipe in the slab and wearing course with iron grill at the top and GI pipe at bottom as per drawing etc. complete.
Providing and fixing stainless steel mooring ring in cement concrete on deck of jetty consist of 32 mm thick steel bar, 225 mm inner diameter, steel ring with 75 mm inner diameter steel hook of 32 mm diametre as per approved drawing etc. complete.(Stainless steel of grade S-304)
Providing and fixing fenders made from used tyres including fixing by stainless steel chain links of 8mm dia. and anchor bolts of 16 mm diameter etc. complete as per drawing and as directed under tidal range.
Providing and fixing D Type Rubber Tyre Fender with necessary fixers etc complete : SIZE 300X300X1000mm
Providing and fixing Indian teak wood framed collar beam / king post / queen post truss, with all Iron work including scaffolding, if necessary, and one coat of primer etc. complete.
Excavation in general in soft material comprising of soft soil, soft murum, sand, hard murum with boulders in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in charge, etc.complete excluding refilling. For Head Works on nalla or any other site of GSDA for initial lift of 0 to 1.5 M
Excavation in general in hard material comprising of soft rock, hard rock, Manjara rock, etc. by blasting / controlled blasting, chiselling as required in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge, excluding refilling. For Head Works on nalla or any other site of GSDA for initial lift of 0 to 1.5 M
Dewatering the excavated trenches and pools of water in the building trenches /pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261).
Providing and fixing 80 mm dia A.C./ P.V.C. pipe weep holes at 1.5 M c/c staggered including cost of all materials and labour involved with all leads and lifts, etc. complete..
Providing and laying in situ Cement Concrete M-15 of trap metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90bags/cum).
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations,slabs, beams, columns, canopies,staircases, newels, chajjas, lintels,pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306). c)Corrosion Resistant Steel (Fe 500)
Providing and casting in situ C.C. of trap metal of approved quality for RCC works as per detailed drawings and designs For Beam or as directed by Engineer-in charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)
Providing and casting in situ C.C. of trap metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)
5 m to G.L. And Parapet
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete..
Providing and fixing in position Cl dapuri steps or 22 mm dia. M.S. bar step with proper anchorage, etc. and providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge.
Providing structural steel work in rolled sections like joists, channels, angles, tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc. and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete.(Bd-C-2/275)
Taking trial bore (Core Bore Sampling) by Callyx machine with TCT/NX bits to gather undisturbed strata samples for investigation in all types of strata, soft soil, murum, hard murum with boulders, soft rock, hard rock and quartzite, etc. The item includes all hire and running cost of Callyx machine, conveying all materials to site of work excluding conveyance of callyx machine and back sampling all over burden strata in glass jar and core samples serially numbered at site in a wooden core box, samples to be taken at 1.0 M interval and conveying to the place as directed by Engineer-in-charge. The diameter of bore in overburden shall be 100 mm and of NX size (50 mm) in other strata. The item shall also include M.S. casing pipe of 2.5 mm thick plate in overburden only and shall be 1.0 M above GL with cap over it. d)In hard rock other than quartzite
Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ±10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer.
Providing, erecting , commissioning & testing of floor mounting type L.T. pannel board (skeletion type) as per detail specifications.
3 core PVC insulated, PVC sheathed copper conductor flat submersible cable
Providing laying & testing of PVC allu. conductor armoured cable (1x3x4) core size & as per details specifications.
Providing and lowering, laying and jointing with provided cable of PVC conduit pipe suitable for insarting cables etc. complete.
Providing, installing, testing, earthing arrangement to installation of motor, L.T. pannel board starter etc. complete as per details specifications.
Providing and lowering, laying and jointing in position Vertical Drop pipe etc. complete. as directed by Engineer & as per specification complete.
Excavation in laterite rock masses mechanically including lift upto 1.5m including trimming and levelling the bed, removing the excavated material upto a distance of 50 mtrs. beyond the area and lifts as below, stacking as directed by Engineer in charge, normal dewatering, excluding backfilling, etc.complete.
Providing and laying in situ Cement Concrete M-15 of trap metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90bags/cum)
Providing laterite stone masonry in cement mortar 1:6 in Foundation and plinth including racking out joints when plastering is to be done/sktriking joints when no plastering is to be done watering and watering complete.
Providing laterite stone masonry in cement mortar 1:6 in Superstructure including racking out joints when plastering is to be done/sktriking joints when no plastering is to be done watering and watering complete
Providing and fixing solid core flush door shutter in double leaf 32mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3mm thick on both faces or as directed ,all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixture sand fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
Providing and fixing aluminium grill` (5.13 Kilogram/ Square Metre) decorative of various sizes as per detail drawing and specification etc. complete. (Prior permission to be obtained from S.E. before execution of this item) ( 5.13 Kilogram/ One Square Metre)
Providing and Fixing 6.00mm thick asbestos cement corrugated sheet roofing confirming to I.S. 456-1970, including galvanised iron J or L hook bolts, galvanised iron and bituminous washers, galvanised iron cramp bolts and nuts and scaffolding complete.
Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS 1239/2004. Medium 50mm.(5.16kg./m) Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.
Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST.
Excavation for foundation/ pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 mtrs. and lifts as below, stacking and spreading as directed, normal dewatering,preparing the bed for foundation and excluding backfilling etc.complete.
Lowering, Laying and Jointing H.D.P.E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II
Providing, supplying, loweing, laying and ficingAir Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. Air Valve Single Ball Flanged / Screwed Type-PN-1
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)
Providing and supplying ISI standard CI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to stores, unloading etc. complete as directed by Engineer-in-charge.
Designing (aesthetically), and constructing RCC Ground service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 m c/c for ESR having capacity upto 500 cum and not more than 6 m c/c for ESR having capacity above 500 cum including excavation in all type of strata, foundation concrete, cement plaster with water proofing compound to the inside face to the container including refilling, disposing off surplus stuff within lead fo 50 m all material and labour charges including lowering laying erecting hoisting and jointing pipe, assembly of inlet outlet washout overflow and byepass arrangements as per deparmental design, providing and fixing accessories such as M.S Ladder, CI manhole frame and cover, water level indicator, lightning conducter, G.I. pipe railing around walkway, and top slab, providing spiral staircase from ground level to roof level, M.S. grill gate of 2 m ht. with locking arrangement of approved design, BB masonry chamber for all valves, ventilating shafts, providing and applying three coats of cement paint to structure including roof slab, epoxy painting to internal surface and antitermite treatment for underground parts of the structure and giving water tightness test as per I.S. code. The job to including painting the name of scheme and other details on the reservior as per the directions of Engineer - in - charge. etc. complete.
A) Rate upto 100000 Lit
B) Rate upto 200000 Lit
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Sluice valves-PN-1(Without by pass)
150mm dia sluice valve
125 mm Sluice Valve
80 mm Sluice Valve
Designing (aesthetically), and constructing RCC Elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 m c/c for ESR having capacity upto 500 cum and not more than 6 m c/c for ESR having capacity above 500 cum including excavation in all type of strata, foundation concrete, cement plaster with water proofing compound to the inside face to the container including refilling, disposing off surplus stuff within lead fo 50 m all material and labour charges including lowering laying erecting hoisting and jointing pipe, assembly of inlet outlet washout overflow and byepass arrangements as per deparmental design, providing and fixing accessories such as M.S Ladder, CI manhole frame and cover, water level indicator, lightning conducter, G.I. pipe railing around walkway, and top slab, providing spiral staircase from ground level to roof level, M.S. grill gate of 2 m ht. with locking arrangement of approved design, BB masonry chamber for all valves, ventilating shafts, providing and applying three coats of cement paint to structure including roof slab, epoxy painting to internal surface and antitermite treatment for underground parts of the structure and giving water tightness test as per I.S. code. The job to including painting the name of scheme and other details on the reservior as per the directions of Engineer - in - charge. etc. complete.
A) Rate upto 100000 Lit
B) Rate upto 200000 Lit
Providing & supplying in standard lengths polyethelene Pipes, conforming to IS 4984/14151/12786/ 13488 with necessary jointing material like mechanical connector i.e.thread/ insert joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.
140mm dia HDPE pipe PE - 100 - 6 kg/cm2
125 mm dia HDPE pipe PE - 100 - 6 kg/cm2
110 mm dia HDPE pipe PE - 100 - 6 kg/cm2
90 mm dia HDPE Pipe PE- 100- 6 kg/cm0
75 mm dia HDPE Pipe PE- 100- 6 kg/cm1
63mm dia HDPE Pipe PE- 100- 6 kg/cm2
50mm dia HDPE Pipe PE- 100- 6 kg/cm2
Providng and supplying Idouble flange Sluice valves confirming for IS 2906/14846 including worn gear arrangement as per test pressure stainless steel spindle, caps including all taxes transportation etc.complete.
100 mm dia sluice valve PN-1
65 mm dia sluice valve PN-1
50 mm dia sluice valve PN-1
Lowering laying & jointing H.D.P.E. Pipe by heating to the ends of pipe with the help of tefflon coated electrimirror/heater to the required temparature & then pressing the end together against each other to form a monolithic & leak proof joint by thermosetting process. the pressing may be required to be done with Jack/Hydraulicjack/Vutt fusion machine etc. complete. with all maerial,labours as directed by Engineer in charge including given satisfacory hydraulic test.
140 mm dia HDPE pipe PE 100 6 kg/cm2
125 mm dia HDPE pipe PE 100 6 kg/cm2
110 mm dia HDPE pipe PE 100 6 kg/cm2
90 mm dia HDPE pipe PE 100 6 kg/cm2
75 mm dia HDPE pipe PE 100 6 kg/cm2
63 mm dia HDPE pipe PE 100 6 kg/cm2
50 mm dia HDPE pipe PE 100 6 kg/cm2
Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position..
140 mm dia HDPE pipe
125 mm dia HDPE pipe
110 mm dia HDPE pipe
90 mm dia HDPE pipe
75 mm dia HDPE pipe
63 mm dia HDPE pipe
50 mm dia HDPE pipe
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)
125 mm dia sluice valve PN-1
110 mm dia sluice valve PN-1
80 mm dia sluice valve PN-1
65 mm dia sluice valve PN-1
50mmdia sluice valve PN-1
Giving satisfactory hydraulic testing of following C. I. D / F Reflex valves, Butterfly valves and Sluice valves.
125 mm dia sluice valve PN-1
110 mm dia sluice valve PN-1
80 mm dia sluice valve PN-1
65 mm dia sluice valve PN-1
50mmdia sluice valve PN-1
Providing, supplying lowering, laying and fixing Air Valves as per IS-14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. Air Valve Single Ball Flanged / Screwed Type-PN-1
Commisioning running and maintaining the scheme to quantites, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and 3 month for regional scheme, together with training of personne spared by MJP/ Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer-in charge.
Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit
Supplying and erecting PVC trunking (PVC casing-ncapping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.2
Supplying and erecting PVC trunking (PVC casing-ncapping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.2
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 modules duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 modules duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 modules duly erected.
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW(Note 12 Mtr)
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW(Note 16 Mtr)
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW( 14 Mtr Point)
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty
Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2.
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification No. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 30 A, 3 pin plug & earth socket and 30A, 3 pin plug top with 30A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame.
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 4 pole RCCB 80A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 8 ways Four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to 800A MCCB.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 11.3 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 150 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 62.5 kVA up to 82.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting bakelite call bell with 6 cm / buzzer with double coil suitable for 230V complete erected on PVC block.
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 3 x 8 extensions complete.
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification no. APWCR/ WC
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 2500 VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
Supplying and erecting 12V/180Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
Supplying 16 amp. 3 pin plug Top bakelite type of 230 V. A.C. supply.
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting storage type water heater 35 litres capacity having standing loss <0.584 kWh / 24 hour / 45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia).
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting slotted angles, frames etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating 11 kV(E), 3 x 70 sq. mm., aluminium conductor XLPE insulated, galvanised steel formed wire armoured (strip) cable laid in provided trench / pipe as per specification no. CB-HT(7-3-1)
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT
Supplying and erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying and laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay)
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV(1-3-14)
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10% p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board.(5-3-18)
Supplying and erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBD
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE(7-6-2)
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL(8-2-12)
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP(9-1-4)
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3 mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OH-PL/HM (excluding luminaries)
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, , IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
Providing earthing with Galvanised cast iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification No. EA-EP
Providing cement concrete for foundation or for concrete filling in 1:3:6 ratio with 20 to 25 mm. stone metal duly plastered with necessary curing for pole muffing or any other purposes. Size= (0.2x0.2x0.4) x 4 Nos = 0.064
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast).
Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing cement concrete for foundation or for concrete filling in 1:3:6 ratio with 20 to 25 mm. stone metal duly plastered with necessary curing for pole muffing or any other purposes. Size= (0.8x0.3x0.7) x 9 Nos = 1.32
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ. (12 Nos. * 11m Each) (2Nos. Stud Pole and 10 Nos. RSJ Pole)
Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no.OH-PL/VCA.
Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA
Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA
Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing.
Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km) as per specification No. OH-CON/ACSR
Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN.
Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI.
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP.
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete.
Supplying and erecting guarding lace for HT OH line with 8SWG G.l. wire to protect the HT OH line with binding wire of 20SWG G.l. wire for 75mm section on either side.
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 3.75 KW/5 HP with discharge 420/120 Litres per Minute (LPM) for head of 18/51 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP
Supplying & erecting Pressure Booster Pump, single phase, 50C/s, A.C. supply of 1.125 KW/1.5 H.P., With discharge of 480 to 31 LPM for 10 to 50 Mtr Head & 25 mm suction/ 25 mm delivery pipe, for Domestic Pressure boosting applications.
Supplying & erecting automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection.
Navigational Channel Marking Buoy: Navigational Channel Marking Buoy, manufactured from UV stabilized Virgin Polyethylene, specially designed to withstand the Harsh Marine Environment. The color pigment added to the material during moulding process, foam filled with highly buoyant closed cell polyurethane with top marks and lights as per IALA recommendations
Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259)
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and constructing Ductile Iron circular manhole 45 cm dia. At top 90 cm at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15 cm thick burnt brick mansonry with 1:1 cement mortar plaster 25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125Kilogramin weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer.
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. Note :One collar should be supplied with each full length plain ended RCC pipe, cost including in rates below. One rubber ring should be supplied with each full length of socketed pipe, cost included in rates below. Note :Only 85% rate is payable till satisfactory hydraulic testing is given. Class ‘NP-II' ( For 2.00 m. length ) 300 MM
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985. 300 MM
Hydraulic testing of RCC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide speci-fied test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.(300 mm)
Capacity of the Plant 0.10 MLD Designing, providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of Integrated Wetland Technology (IWT) based Sewage Treatment Plant (STP) consisting of Screen chamber, Oil and Grease trap, RCC Primary treatment tank (including manholes, vent pipes and graded gravel media) and RCC Secondary treatment tank (SBBR)(including gravel media, PVC sheets, wetland plants, plastic mesh, etc. as required.) RCC intermediate and treated water tank, sludge recirculation pump and pipe network, room for tertiary treatment unit, Electrical and Mechanical works for tertiary treatment including associated piping work, internal pathways, wire fencing, etc. complete as turnkey job with all involved civil, electrical and mechanical works inclusive of following items, units as per detailed specifications for civil, electrical and mechanical Components with all duties and taxes excluding GST Allied structure shall be constructed as per the provision in appropriate and relevant standards and Description. Design guidelines of respective authorities. RCC and civil works will be as directed by Engineer-in-charge. Sewage Treatment Plant (STP) to be designed to treat the raw sewage with the characteristics in table in number “A” to produce the treated sewage with characteristics as mentioned in table number “B”
A) Raw Sewage Characteristics: Temperature - Ambient pH - 5.5-9.0 BOD5 - 300 mg/L COD - 600 mg/L TSS -500 mg/L Total N : 50 mg/L Total P : 15 mg/L Faecal Coliform (MPN) : 10^6- 10^7 B) Treated Water Characteristics: Temperature - Ambient pH-6.5-B.0 BOD < 10mg/L COD < 40 mg/L TSS < 20 mg/L Total N < 5 mg/L Total P <1 mg/L Faecal Coliform (MPN) < 10 Note: If raw sewage characteristics observed as per test are more critical than the mentioned in description (Table A) same shall be used for the design of Sewage Treatment Plant (STP), otherwise raw sewage characteristics mentioned (Table A) shall be used.
Following Components are Included 1. Screening Chamber: Screening is a unit operation that separates larger floating particles in water. Found in different size screening prevents floating material entering in waste water treatment units. 2. O & G Trap: Designing, providing and constructing manual type O&G removal mechanism in RCC (M-300) capable of removing grease, oil and scum including providing and making necessary arrangements. Removal will be done manually and stored in a tank for defined period after which it will be disposed to appropriate disposal facility. Inlet and outlet channels of required sizes as make are required to connect the flow to connecting unit, etc. complete including hydraulic testing for water tightness of structure having adequate FB, and platform. All arrangements shall be as detailed specifications and as directed by EIC if not clear.
3. Primary Treatment Tank: Designing, providing, constructing and hydraulic testing in RCC (M-300) watertight underground primary treatment tanks (including PSRT, SABR, and BSF). Designs as per the drawings given by EEPL (technology partner of IWT). Design will consider the average flow, the 2 DWF and the peak flow. Tank will be covered and PVC vent pipes having sand and activated carbon (as guided by EEPL) will be installed to prevent Odour. 0.5% of horizontal slope is provided in the tank for the collection of sludge. Minimum free board of 0.3m is provided. It includes providing all necessary items such as gravel media, piping, valves, joints, launder, baffling, etc. as shown in drawings & additional items will be as directed by EIC. 4. Static Bed Biofilm Reactor (SBBR): Designing, providing, constructing and hydraulic testing in RCC (M-300) watertight underground secondary treatment tanks (SBBR). 0.5% of horizontal slope is provided in the tank for the collection and recirculation of sludge. Designs as per the drawings given by EEPL (technology partner of IWT). Design will consider the average flow, the 2 DWF and the peak flow. Wetland plants will be planted on gravel media (grading as per EEPL). In the open recirculation sections a combination of Bottom screen, MS mesh, PVC sheet, and plastic mesh will be provided to support Wetland plants. Minimum free board of 0.3m is provided. It includes providing all necessary items such as gravel media, piping, valves, joints, launder, baffling, structural steel work, bottom screens, grill work, PVC sheet, plastic mesh, wetland plants etc. as shown in drawings & additional items will be as directed by EIC.
5. Intermediate & Treated Water Tank: Designing, providing, constructing and hydraulic testing in RCC (M-300) watertight underground tank acting as a feed tank for tertiary treatment avoiding backflows. Designs as per the drawings given by EEPL (technology partner of IWT). Design will consider the average flow, the 2 DWF and the peak flow. Tank will be covered. It includes providing all necessary items such as piping, valves; joints etc. as shown in drawings & additional items will be as directed by EIC. 6. Tertiary Treatment Unit: Designing, providing, installing and hydraulic testing of feed pump, activated carbon filter vessel with required sand and required activated carbon quantities, hypo dosing tank, dosing pump, necessary piping, pumps, joints, electrical cables, connections etc. complete. It is also include trail & run of tertiary treatment unit. After dosing contact time of 30 min allows 99.99% reduction of outstanding fecal coliform. Chlorine dosage will be as per standard requirement of 5-10ppm.] to match effluent quality with the standards laid down by Maharashtra Pollution Control Board
7. Treated Water Outfalls: Designing, providing, constructing appropriate outfall sewer of RCC NP Class -III pipe to discharge treated effluent, untreated effluent from bypass chambers to the local Nallah at the point shown on the drawing including necessary chambers for inspection and cleaning including excavation, dewatering, refilling, concrete, encasing / bedding concrete to the local Nallah at the point shown on the drawing including necessary chambers for inspection and cleaning including excavation, dewatering, refilling, concrete, encasing / bedding concrete Notes: 1) Screen chamber and O and G trap are of manual type. 2) Sodium hypochlorite dosing is adopted. 3) Dedicated sludge management is not provided as it is required 12 to 18 months basis cycle from Primary Solid Removal Tank (PSRT) and Sequential Anaerobic Baffle Reactor (SABR) 4) Sludge will be removed from the Sewage Treatment Plant (STP) and will be disposed according to stakeholder’s general practice to nearest Fecal Sewage Treatment Plant (FSTP) Or as per standard guidelines. Provision of sludge drying beds is not considered in IWT scope. If sludge drying beds are to be provided then it shall be additional cost to the Integrated Wetland Technology (IWT) Sewage treatment plant (STP) 5) No separate Independent lab and admin building as tertiary treatment room is not provided as room for tertiary treatment unit is large enough to accommodate required manpower, storage and instruments 6) Site clearance, wire fencing to the boundary of STP is included in scope of work
7) All water retaining structures are in M30. grade of concrete 8) Water table is considered 5m below FGL for design 9) Soil bearing capacity is considered as 20 T/m2 at 1.5m below from FGL 10) Grade of cement used is OPC 53 grade. (Contractor can use higher grade). 11) Grade of steel is used as Fe 500 12) Peak factor considered in design of STP as per CPHEEO manual guideline 13) Hypo dosing required during trial run and commissioning is not considered in scope of work. 14) Water and Power required during construction and trail & run shall be provided by client/local body. 15) Power available near STP is assume to be LT power supply. 16) All Integrated Wetland Technology (IWT) designs will be provided by IWT technology provider. 17) Defect liability period shall be of 5 years to the contractor 18) Maintenance and repair work of IWT shall be responsibility of the contractor and technology provider combine
Capacity of the Plant 0.05 MLD Designing, providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of Integrated Wetland Technology (IWT) based Sewage Treatment Plant (STP) consisting of Screen chamber, Oil and Grease trap, RCC Primary treatment tank (including manholes, vent pipes and graded gravel media) and RCC Secondary treatment tank (SBBR)(including gravel media, PVC sheets, wetland plants, plastic mesh, etc. as required.) RCC intermediate and treated water tank, sludge recirculation pump and pipe network, room for tertiary treatment unit, Electrical and Mechanical works for tertiary treatment including associated piping work, internal pathways, wire fencing, etc. complete as turnkey job with all involved civil, electrical and mechanical works inclusive of following items, units as per detailed specifications for civil, electrical and mechanical Components with all duties and taxes excluding GST Allied structure shall be constructed as per the provision in appropriate and relevant standards and Description. Design guidelines of respective authorities. RCC and civil works will be as directed by Engineer-in-charge. Sewage Treatment Plant (STP) to be designed to treat the raw sewage with the characteristics in table in number “A” to produce the treated sewage with characteristics as mentioned in table number “B”
A) Raw Sewage Characteristics: Temperature - Ambient pH - 5.5-9.0 BOD5 - 300 mg/L COD - 600 mg/L TSS -500 mg/L Total N : 50 mg/L Total P : 15 mg/L Faecal Coliform (MPN) : 10^6- 10^7 B) Treated Water Characteristics: Temperature - Ambient pH-6.5-B.0 BOD < 10mg/L COD < 40 mg/L TSS < 20 mg/L Total N < 5 mg/L Total P <1 mg/L Faecal Coliform (MPN) < 10 Note: If raw sewage characteristics observed as per test are more critical than the mentioned in description (Table A) same shall be used for the design of Sewage Treatment Plant (STP), otherwise raw sewage characteristics mentioned (Table A) shall be used.
Following Components are Included 1. Screening Chamber: Screening is a unit operation that separates larger floating particles in water. Found in different size screening prevents floating material entering in waste water treatment units. 2. O & G Trap: Designing, providing and constructing manual type O&G removal mechanism in RCC (M-300) capable of removing grease, oil and scum including providing and making necessary arrangements. Removal will be done manually and stored in a tank for defined period after which it will be disposed to appropriate disposal facility. Inlet and outlet channels of required sizes as make are required to connect the flow to connecting unit, etc. complete including hydraulic testing for water tightness of structure having adequate FB, and platform. All arrangements shall be as detailed specifications and as directed by EIC if not clear.
3. Primary Treatment Tank: Designing, providing, constructing and hydraulic testing in RCC (M-300) watertight underground primary treatment tanks (including PSRT, SABR, and BSF). Designs as per the drawings given by EEPL (technology partner of IWT). Design will consider the average flow, the 2 DWF and the peak flow. Tank will be covered and PVC vent pipes having sand and activated carbon (as guided by EEPL) will be installed to prevent Odour. 0.5% of horizontal slope is provided in the tank for the collection of sludge. Minimum free board of 0.3m is provided. It includes providing all necessary items such as gravel media, piping, valves, joints, launder, baffling, etc. as shown in drawings & additional items will be as directed by EIC. 4. Static Bed Biofilm Reactor (SBBR): Designing, providing, constructing and hydraulic testing in RCC (M-300) watertight underground secondary treatment tanks (SBBR). 0.5% of horizontal slope is provided in the tank for the collection and recirculation of sludge. Designs as per the drawings given by EEPL (technology partner of IWT). Design will consider the average flow, the 2 DWF and the peak flow. Wetland plants will be planted on gravel media (grading as per EEPL). In the open recirculation sections a combination of Bottom screen, MS mesh, PVC sheet, and plastic mesh will be provided to support Wetland plants. Minimum free board of 0.3m is provided. It includes providing all necessary items such as gravel media, piping, valves, joints, launder, baffling, structural steel work, bottom screens, grill work, PVC sheet, plastic mesh, wetland plants etc. as shown in drawings & additional items will be as directed by EIC.
5. Intermediate & Treated Water Tank: Designing, providing, constructing and hydraulic testing in RCC (M-300) watertight underground tank acting as a feed tank for tertiary treatment avoiding backflows. Designs as per the drawings given by EEPL (technology partner of IWT). Design will consider the average flow, the 2 DWF and the peak flow. Tank will be covered. It includes providing all necessary items such as piping, valves; joints etc. as shown in drawings & additional items will be as directed by EIC. 6. Tertiary Treatment Unit: Designing, providing, installing and hydraulic testing of feed pump, activated carbon filter vessel with required sand and required activated carbon quantities, hypo dosing tank, dosing pump, necessary piping, pumps, joints, electrical cables, connections etc. complete. It is also include trail & run of tertiary treatment unit. After dosing contact time of 30 min allows 99.99% reduction of outstanding fecal coliform. Chlorine dosage will be as per standard requirement of 5-10ppm.] to match effluent quality with the standards laid down by Maharashtra Pollution Control Board
7. Treated Water Outfalls: Designing, providing, constructing appropriate outfall sewer of RCC NP Class -III pipe to discharge treated effluent, untreated effluent from bypass chambers to the local Nallah at the point shown on the drawing including necessary chambers for inspection and cleaning including excavation, dewatering, refilling, concrete, encasing / bedding concrete to the local Nallah at the point shown on the drawing including necessary chambers for inspection and cleaning including excavation, dewatering, refilling, concrete, encasing / bedding concrete Notes: 1) Screen chamber and O and G trap are of manual type. 2) Sodium hypochlorite dosing is adopted. 3) Dedicated sludge management is not provided as it is required 12 to 18 months basis cycle from Primary Solid Removal Tank (PSRT) and Sequential Anaerobic Baffle Reactor (SABR) 4) Sludge will be removed from the Sewage Treatment Plant (STP) and will be disposed according to stakeholder’s general practice to nearest Fecal Sewage Treatment Plant (FSTP) Or as per standard guidelines. Provision of sludge drying beds is not considered in IWT scope. If sludge drying beds are to be provided then it shall be additional cost to the Integrated Wetland Technology (IWT) Sewage treatment plant (STP) 5) No separate Independent lab and admin building as tertiary treatment room is not provided as room for tertiary treatment unit is large enough to accommodate required manpower, storage and instruments 6) Site clearance, wire fencing to the boundary of STP is included in scope of work
7) All water retaining structures are in M30. grade of concrete 8) Water table is considered 5m below FGL for design 9) Soil bearing capacity is considered as 20 T/m2 at 1.5m below from FGL 10) Grade of cement used is OPC 53 grade. (Contractor can use higher grade). 11) Grade of steel is used as Fe 500 12) Peak factor considered in design of STP as per CPHEEO manual guideline 13) Hypo dosing required during trial run and commissioning is not considered in scope of work. 14) Water and Power required during construction and trail & run shall be provided by client/local body. 15) Power available near STP is assume to be LT power supply. 16) All Integrated Wetland Technology (IWT) designs will be provided by IWT technology provider. 17) Defect liability period shall be of 5 years to the contractor 18) Maintenance and repair work of IWT shall be responsibility of the contractor and technology provider combine
Part B :- Schedule of Royalty, Testing charges, Designs for construction work.
B2 :- Testing Charges for Construction material
RUBBLE
Crushing Value /Compressive Strength, Water Absorption & Specific Gravity,
BASIC TEST OF AGGREGATE
Sieve Analysis.
Water Absorption, Specific Gravity,Impact Value, Crushing Value.
Soundness.
Stripping Value. (for Bituminous Work)
Flakiness Index & Elongation Index.
FINE AGGREGATE. (Artificial Sand)
Fineness Modulus ( Sieve Analysis ),Silt & Clay Content
Silt Factor.
Chloride & Sulphate Content.
FINE AGGREGATE. (Natural Sand)
Fineness Modulus ( Sieve Analysis ),Silt & Clay Content
Silt Factor.
Chloride & Sulphate Content.
BASIC TEST OF CEMENT
Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness.
CONCRETE
Compressive Strength OF C.C. Cube (Set of 3 cubes).
Concrete Mix Design (With all Tests on basic materials)
Permeability Test.
Water
PH Value, Sulphate & Chloride Content.
STEEL ANTI CORROSIVE TEST
Upto 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
Thickness of Coating. (Set of 2 Bars)
Chemical Resistance Test.( Set of 8 Bars )
Hardness of Coating Test .
Density, Moisture Content.
ALUMINIUM SECTION
Thickness, Mass Per Running meter,
CERAMIC TILES / VITRIFIED TILES
Water Absorption, Modulus of Rupture (Set of 6 Tiles)
P.V.C. PIPES (NONPLASTISIZED)
Weight per running meter,Diameter of pipe & wall thickness of pipe
LATERITE
Crushing Value /Compressive Strength, Water Absorption & Specific Gravity,
MURUM
Sieve Analysis.
Liquid limit & plastic Limit.
C.B.R. Test ( Lab ) With compaction test.
BITUMEN
Penetration, Softening Point, Flash & Fire Point, Specific Gravity
Extraction &Sieve Analysis of Bituminous mix ( for BM/DBM/AC)(2 samples of extraction for one sieve analysis including extraction)
Job Mix Design with all Tests on aggregate (Excluding bitumen) for DBM/SDBC/AC/SMA (Stone Mastic Ashphalt) ( Testing of Bitumen shall be seperately Charged)
Extraction Test.(Bituminous mix)
NON -DESTRUCTIVE TEST
Rebound Hammer Test.
Ultrasonic Pulse Velocity
PILE TEST
Carrying out integrity test on piles
Carrying out Dynamic load test on piles at 1.5 times the design load on any dia of pile.
a) On first pile
b) Subseqent Piles
B3 :- Royalty Charges for material
Ruble
DVP Infra Projects Pvt. Ltd.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid