Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹16.0 LAccepted-AOC | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹16.6 LRejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹17.1 LRejected-Finance | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FORTH₹17.9 LRejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | FORTH | Rejected-Finance BEING NOT LOWEST | |
| 5 | FIFTH₹17.9 LRejected-Finance | FIFTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
5 Mar 2024, 6:00 pmClosed
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
SPECIAL REPAIR REPLACEMENT OF INTERNAL WIRING AND ALLIED WORKS IN ADMIN BUILDING P 8 AT SDI AND PROVISION AIR CONDITIONERS AT ASTE UNDER GE AF MARATHAHALLI
2024_MES_641085_1
8675/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹40,000
Yes
27 Mar 2024
7 Feb 2024
10 Mar 2024
7 Feb 2024
5 Mar 2024
21 Feb 2024
Amount
Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed.
Painting of ceiling fans/ exaust fan complete, in situ with symthetic enamel paint by spraying including filling cavities withfiller, one coat after cleaning all dust etc.
Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed.
Taking down carefully main switches DB's/ MCB DB's and making good the disturbed surfaces of walls etc complete all as specified and directed.
M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including modular metal flush boxes to accomodate modular switches & modular white cover plate and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One light point/fan point controlled by one switch.
Description al as per item no 05 above but one light point controlled by 2 way switch.
Description all as per Item No.05 above but for One 3 pin, 05 /06 Amps socket outlet point on same board controlled by one , one way 05/06 Amps switch.
Description all asper Item No.05 above but for One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch.
Description all as per Srl Item No. 5 here-in-before , but with 2.5 Sqmm cable and 1.5 Sqmm copper conductor as earth wire for 3 pin, 15 Amps socket outlet complete ( Socket /Switch to be measured and paid for separately).
Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed
Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed
S & F modular socket 06/16 Amps 2/3 pin combined 2 module complete all as specified & directed.
S & F modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing modular switch2 way , 06 Amps 1 module complete all as specified & directed
Supply and fix in conduit sub main wiring FRLSH PVC insulated stranded copper conductor 2 x 6 Sqmm drawn into and including Concealed PVC conduit complete all as specified and FRLSH PVC insulated copper wire 1x6 Sqmm for continuous earth wire complete all as specified & directed .
Supply and fix in conduit sub main wiring FRLSH PVC insulated stranded copper conductor 2 x 4 Sqmm drawn into and including Concealed PVC conduit complete all as specified and FRLSH PVC insulated copper wire 1x4 Sqmm for continuous earth wire complete all as specified & directed
Supply and fix in conduit sub main wiring FRLSH PVC insulated stranded copper conductor 2 x 2.5 Sqmm drawn into and including Concealed PVC conduit complete all as specified and FRLSH PVC insulated copper wire 1 x2.5 Sqmm for continuous earth wire.
Taking down old U/S DB & Supply and fix sheet metal enclosure three phase double door DB flush to wall fitted with bus bar, and neutral link for MCB (without MCB's) 4 ways TPN complete all as specified.
All as per Ser No 18 here in before but 12 ways SPN DB.
All as per Ser No 18 here in before but 8 ways SPN DB.
All as per Ser No 18 here in before but 4 ways SPN DB.
Supply and fix MCB, single pole 240 volts, capacity 6 Amps to 32 Amp current rating 10KA breaking capacity complete all as specified .
Supply and fix MCB, single pole and neutral 240 volts, capacity 40 to 63 Amps, 'B' Series 50Hz 10 KA breaking capacity complete all as specified.
Supply and fix MCB TPN 63A 415 V B series all as directed.
Supply and fix ceiling rose suarface bakelite three terminals 65x50mm complete all as specified.
S & F electronic fan regulator modular type, 2 module, 120 W including complete all as specified and directed.
Taking out old unserviceable light fitting and Supply and fix round shape 12 watt 220 volts Ac recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Taking down old unserviceable 1x14W light fitting, S&F LED PC batten light fitting of 2 feet, 10 watt, with energy efficient LED and integrated electronic driver of 10W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
Taking down old unserviceable 1x20W light fitting, S&F LED PC batten light fitting of 4 feet, 20 watt, with energy efficient LED and integrated electronic driver of 20W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
Taking down old unserviceable fitting & S&F LED luminaire 600mmx600mm, 35/36 watt,220 V Ac recessed/ surface type with high efficiency PMMA diffuser soft glare free light complete with driver,holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper cunductor cases of suitable size complete.
Taking down rusted GI wire and Supply & fixing GI earth wire 4.00 mm dia for interconnecting of earth electrodes all as specified.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and 20mm bore light gradeGI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009.
Supply and install hi wall split units air conditioner indoor/outdoor of capacity 1.5 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed. (Note: The extra length of suitable size of AC gas copper pipe/ cable for installation of AC as per site requirement is deemed in the quoted rate. ) Make :- HITACHI/DAIKIAN/CARRIER/VOLTAS
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed. Make- V-GUARD/VOLINA/ VINITEC
M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
M&L for mild steel stand (FACTORY MADE) duly painted suitable for fixing 3/2/1.5 TR AC out door unit fixing in wall / floor, including making bore required size for copper pipe & copper cable with sweating pipe required size and length upto ground level complete all as spcecified and directed.
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB double pole of 20 Amps capacity complete all as specified and directed by Engr-in-charge
GKR and CO
kamadhenu Electricals
RRK PROJECTS
VSHVAS CIVIL AND ELECTRICAL SERVICES PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .