| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC NO 26 GURU AMARDAS COLONY BHAINSA NAKA SAGAR MADHYA PRADESH 470001 | SAGAR | MADHYA PRADESH | 470001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹18.7 L+₹2.4 L (14.8%)Rejected-Finance 3 2 G NO 1 ROSHAN VIHAR EAST SADATPUR NORTH EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹19.3 L+₹3.0 L (18.5%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹19.9 L+₹3.6 L (21.9%)Rejected-Finance | L4 | Rejected-Finance Being Not L1 | |
| 5 | L5₹21.9 L+₹5.6 L (34.3%)Rejected-Finance | L5 | Rejected-Finance Being Not L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Dec 2020, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR MAINTANANCE OF UNSERVICEABLE UG LT CABLE PANEL BOARD AND CONNECTED ITEMS AT AF OJHAR
2020_MES_395282_1
8704/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹50,000
Yes
4 Feb 2021
13 Nov 2020
11 Dec 2020
14 Nov 2020
9 Dec 2020
27 Nov 2020
Amount
Re stringig of ACSR conductor after dismantling winding from insulator in position up to permisible sag and re winding on insulators with new winding wire complete all as specified and as directed by Engr-in-Charge.
Cutting of branches of trees not exceeding 30 cm girth including disposal of unserviceable material to a distance n.exc 50m and cleaning to a distance of 2 Mtr from either side of the O.H line.
Supply & fix in repairs insulators pin type porcelain vitreous white insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut 65mm dia and 100mm height for 1100 V grade complete all as specified and directed.
Supply & fix in repairs loop type, porcelain, vitreous brown insulator small with overall dimentios size 65 x 90mm with clearance hole of 16mm for 1100 volt grade complete all as specified and directed.
S&F PVC insulated and weather proof twin core copper multi stranded conductor cable 2.5 Sqmm size as required length for replacing unserviceable cable for service connection/street light/gate light where ever found unserviceable and required from over head conductor or junction box, Complete all as specified & as directed by Engineer-In-Charge.
M&L for Preparation of old painted surfaces of concreate poles 7.5 Mtr long and painting with two coats of weather proof apex paint white coloured with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, Also marking of pole numbers in white with black background rectunglar/eleiptical on pole all as specified & directed by the Engr-in-Charge.
M&L for Preparation of old painted steel surfaces of cross arms, bracings supports of concreate poles and painting two coats of aluminium paint all as directed for LT electric O/H lines all as specified.
M&L for Preparation of old painted surfaces of steel tublar poles LT 7.5 to 8.5 Mtr long & painting two coats of aluminium paint with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, including existing cross arm/angle iron/clamps/brackets etc & marking of pole numbers in white on black background all as directed.
S/F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20 x 15 cm size.
Supply and fix MCCB Thermal magnatic Three pole 415 Volts,50 HZ, 25 KA 63Amps adjustable DNO 100C Cat No-CM9161200HOOG of L&T Make or equivalent Model of Legrand/Siemens.
Supply and fix MCCB Thermal magnatic Three pole 415 Volts,50 HZ, 25 KA 100Amps adjustable DN1-250C Cat No-CM90638OOLO of L&T Make or equivalent Model of Legrand/Siemens.
Supply and fix MCCB Thermal magnatic Three pole 415 Volts,50 HZ, 25 KA 160Amps adjustable DN1-250C Cat No-CM90638OONO of L&T Make or equivalent Model of Legrand/Siemens.
Supply and fix MCCB Thermal magnatic Three pole 415 Volts,50 HZ, 25 KA 250Amps adjustable DN1-250C Cat No-CM90638OOPO of L&T Make or equivalent Model of Legrand/Siemens.
Supply and fix MCCB Thermal magnatic Three pole 415 Volts,50 HZ, 36 KA 400Amps adjustable DN3-400D Cat No-CM93001OOOOX1 of L&T Make or equivalent Model of Legrand/Siemens.
Taking down carefully unserviceable fittings of the panel board such as volt meter, ammeter and removing to store for safe custody or for reuse
Disconating & taking out LT UG cable of any size.
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable with aluminium conductor 1100V grade 4 core cross sectional area 10 sqmm all as spfd and directed laid in trench or passing through pipe.
All as per item No 18 here-in-before above but 4 core 16 Sqmm
All as per item No 18 here-in-before above but 3 1/2 core 25 Sqmm
All as per item No 18 here-in-before above but 3 1/2 core 35 Sqmm
All as per item No 18 here-in-before above but 3 1/2 core 50 Sqmm
All as per item No 18 here-in-before above but 3 1/2 core 70 Sqmm
All as per item No 18 here-in-before above but 3 1/2 core 95 Sqmm
All as per item No 18 here-in-before above but 3 1/2 core 185 Sqmm
All as per item No 18 here-in-before above but 3 1/2 core 300 Sqmm
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. Of size 38mm
All as per item No 39 here-in-before above but 63mm
All as per item No 39 here-in-before above but 94mm
All as per item No 39 here-in-before above but103mm
Supply and fix 50mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
Supply and fix 80mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
M&L for Boring of holes under Road, Pavements, Hard Standing by trench less technology at a depth 0.6 Mtr from top surface including supply & fix HDPE pipe of 80 mm dia suitable for 0.4 MPA working pressure complete all as specified and directed by Engineer-in- Charge.
M & L for Straight through joints (heat shrink type) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables 3 1/2 core 35 to 70 Sqmm.
M & L for Straight through joints (heat shrink type) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables 3 1/2 core 95 to 120 Sqmm.
M & L for Straight through joints (heat shrink type) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables 3 1/2 core 150 to 400 Sqmm.
Supply only Aluminium crimping lugs eye type of 400 Sqmm
All as per item no-40 above but 300 Sqmm
All as per item no-40 above but240 Sqmm
All as per item no-40 above but185 Sqmm
All as per item no-40 above but 150 Sqmm
All as per item no-40 above but 120 Sqmm
All as per item no-40 above but 95 Sqmm
All as per item no-40 above but70 Sqmm
All as per item no-40 above but 50 Sqmm
All as per item no-40 above but 35 Sqmm
All as per item no-40 above but 25 Sqmm
All as per item no-40 above but 16 Sqmm
M&L for removal green vegetation, Cutting of trees with girth not more then 10 cm from 11 KV sub station yard, sub station, pump house area etc including disposal of cut material not more than 50 mtr distance and levelling/surfacing the ground all as directed by Engr-in-Charge.
M&L for filling 20 mm graded crushed stone aggregate as in sub station yard all as directed by Engr-in-Charge
Removal of debbries material beyond 500 mtr upto total distance of 1.5 Km & depositing where directed at a level not exceding 1.5 mtr above the starting point complete all as directed.
M &L for locating under ground cable fault within 06 hrs including Sunday or any holiday using cable holdidg fault locator taking all necessary precautions as directed by Engr- in - charge Note :- If fault not located by the contractor within specified time a recovery of an amount of double the quoted rate/will be recovered perday
M & L for Reparing ,welding / Fabricaion Electrical panel with CRCA sheet 3 MM including hinges & doors & Panting manual scraping of old painted surface and providing spray painting as per existing colour with one coat of synthetic enamelled paint on outer surface body of following size of LT Panel Sets complete all as Directed by Engineer-In-Charge
Supply an fix mild steel plates (plane or chequerred) channels, square cut or notched ( ordinary and counter sunk) forming holes without any attachment of steel Fe - 410W ( Gde-E-250) quality - B as in florring and is supproting members of required size and section duly cutting and welding with foundation and including one coat of red oxide primer and two coats of synthetic enamel paint etc all as directed by Engineer - in - charge.
Demolishion of cement concrete road/ surface of any in posation not otherwise specifically provided for and removing of rubbish, complete all as directed by Engineer in charge.
Material and labour for PCC (1:3:6) type C-1, using 20mm graded aggregate as in coping of foundation complete all as directed.
Supply and placing ELECTROMAT High voltage Insulating rubber mat suitable for 1100 volt AC supply working pressure of size 1.0 mtrx2.0 mtrx 10 mm thick and ISI Make
Supply and placing ELECTROMAT High voltage Insulating rubber mat suitable for 11000 volt AC supply working pressure of size 1.0 mtrx2.0 mtrx 19 mm thick and ISI Make
Maintainance of Automatic power Factor Controlling Panel at MES site by Cleaning, Rewiring, Replacement of components like Capacitors, Contactors, MCB/MCCB, APFC Controller , Indicating lamps, Instruments Push Buttons, switches, wires cable termination etc. And demo of working Panel with proper relay setting & loadwise capacitor switching at Location Technical Area Sub station transformer 400KVA , 100 + 30 KVAR APFC Panel Contractor-Supplier Must be APFC manufacturer & CPRI Approved PB ,shuold have supplied the same to MES Components will be measured separately under respective items except wiring which is included in the quoted rates’’
Maintainance of Automatic power Factor Controlling Panel at MES site by Cleaning, Rewiring & Auto Manual wiring, Replacement of components like Capacitors, Contactors, MCB/MCCB, APFC Controller , Indicating lamps, Instruments Push Buttons, switches, wires cable termination , etc. And demo of working Panel with proper relay setting & loadwise capacitor switching at Location Technical Area Sub station transformer 1000 KVA 210+50 KVAR APFC Panel Contractor-Supplier Must be APFC manufacturer & CPRI Approved PB ,shuold have supplied the same to MES Components will be measured separately under respective items except wiring which is included in the quoted rates’’
Supply only APFC Relay 12 step(Epcos-br6000/L&T
Supply only Current Transformer(Veritech/Asian)
Supply only Contactor Cap Duty MOC 12.5(L&T/Siemens)
Supply only Lamp Replacement PB-G-2,R-1,,IL--R-3,Y-1,B-1(L & T/Craftech)
Supply only Exhaust Fan 9"(Renord/Almondor)
Supply only APFC Relay 14 stage (L&T/Epcos)
Supply only MNX 18 Contactor(L&T/Siemens)
Supply only MNX 32 Contactor(L&T/Siemens)
Supply only MNX 50 Contactor(L&T/Siemens)
Supply only Push Buttons, Indicating Lamps, Switches(L&T/Siemens)
Supply onlyLamp Replacement R, Y, B(L&T/Craftech)
Supply only Contactor Cap 32A MNX 32(L&T/Siemens)
Supply only MCCB 100A 3P 18KA DU100D(L&T/Siemens)
Supply only ML2 Contactor(L&T/Siemens)
Supply only ML3 Contactor(L&T/Siemens)
Supply only ML4 Contactor(L&T/Siemens)
Supply only MNX 18 Contactor with surch supressor
Supply only Capacitor L&T Box different KVAR Standard duty (L&T/Javic/Epcos)
Supply only Contactor MNX 70 A(L&T/Siemens)
Supply onlyBusbar copper 250 A,3 Phase & N(FOR S/S at Domestic area .”
Supply only Indicating Lamps Red
Anand Trading Co
K R Electricals
Paras Electricals
LOKMANYA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .