| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.8 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹19.5 L+₹16,702.50 (0.86%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹19.8 L+₹42,369.50 (2.19%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹21.1 L+₹1.7 L (8.88%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹21.4 L+₹2.1 L (10.7%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
₹24.2 L
EMD Value
₹48,360
Closing Date
2 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Agra
112 Taj Road, Agra Cantt
SPL REPAIR OF BLDG NO. EWT-8 UNDER AGE (I) FATEHGARH
2022_MES_567304_1
86126/E8
Open Tender
Civil Works
Item Rate
180 days
Fatehgarh
MES contractors enlisted in Class E category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹48,360
Yes
8 Feb 2023
5 Dec 2022
9 Jan 2023
5 Dec 2022
2 Jan 2023
19 Dec 2022
5 Dec 2022 - 12 Dec 2022
Amount
Demolition of cement concrete in any description and in any position complete all as specified and directed
M & L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping & benching complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm each not exc 4.00 sqm each complete all as specified and directed.
S&F Steel windows with side hung shutters including box type hinges with 2 Nos steel handles of 100mm size MS tower bolt of 100 mm size complete with glazing bars,dovetailed or welded complete all as specified and directed.
S&F Steel windows with side hung shutters including box type hinges with 2 Nos steel handles of 100mm size MS tower bolt of 100 mm size, complete without glazing bars,dovetailed or welded complete all as specified and directed.
S&F Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
M & L for framed work such as guard bars fixed to flat iron or to box type window frame confirming to Fe-290 gde E-165 complete all as specified and directed.
MS work as in Framed work as in chowkhats of doors or gates of angle or other section with gusset plates, rails, braces, etc.,conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F 35 mm thick Plain, framed,panelled shutters(any number of panels), with panels of timber flat on both sides(feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
S&F 35 mm thick 2nd class hardwood as in Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S & F mild steel sliding door bolt 300mm long clip type, stove enamelled black with bright bolt not less than 16mm dia complete all as specified and directed.
S & F mild steel barrel tower bolt 200mm long, stove enameled black with bright bolts complete all as specified and directed.
S & F mild steel pressed handle oval type stove enameled black of size 150mm complete all as specified and directed.
S&F mild steel butt hinges cold rolled of size 100mm medium weight complete all as specified and directed.
M&L Preparing surfaces new of steel and applying two coats of synthetic enamel paint, complete all as specified and as directed.
All as per item No.16 above but over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L preparing surfaces new of wood and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples, wodden beads to steel windows/wodden doors complete all as specified and directed
Taking down cement plaster on brick wall or stone wall etc. including raking out joints hacking for key, scrubbing down with water etc and disposed off unserviceable material of out side MD land complete all as specified and directed
Demolition of brickwork masonary built in lime or cement mortar including all quiens arches, pillars etc including concrete articles complete all as specified and directed
M & L Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cm (1:6) complete all as specified and directed
All as per item No.23 above but except Bricks etc complete all as specified and directed.
M & L Rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed
M & L Rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed
M & L for preparation of new plastered surfaces of walls and applying two coats of OBD over a coat of chalk whitening over a coat of 1mm thick wall putty complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer over a coat of 1mm thick wall putty complete all as specified and as directed.
M & L for complete removal of existing treatment on wall and applying two coats of OBD over a coat of 1mm thick wall putty and one coat of chalk whitening complete all as specified and directed.
M & L for complete removal of existing treatment on wall and applying two coats of Cement based paint over a coat of 1mm thick wall putty and one coat of alkali resistant primer complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving n.exc 15cm thickness (below or above ground level) etc complete all as specified and directed.
M & L Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors,skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed or bedding layer of CM (1:6) complete all as specified and directed.
M & L 50 mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in plinth protection, sub base of floors complete all as specified and directed.
Taking down roof trusses, coupled rafters or trussed beams above 4 meter and upto 8 meter complete all as specified and directed.
Dismantling framed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Dismantaling of asbestos cement (Corrugated, semi corrugated etc) sheetiting in roof covering complete all as specified and directed.
S & F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thickness of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thickness of any colour having tensile strength of 550Mpa as in ridge, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F for roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde E-250) quality B complete all as specified and directed.
S & F for Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (Gde E-250) quality B complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
S&F False Ceiling Horizontal level regular edge grid 600 x600 mm from work using hot dip sections and fixing tiles vinyl laminated MPL gypsum panels size 595x595x6 to 8mm thick after lamination, suspended the grid with grid hangers to Roof Truss / RCC Slab all as per manufactured instruction complete all as specified and directed.
Taking down copper/aluminium point wiring of any discription and any position (light, fan, socket or power point) complete, including taking down of fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket exhaust fan, ceiling fan and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed
Taking down Aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit medium grade with fittings (ISI marked) not less than 20 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following- Note- (i) The quoted rates are deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4, paint / distemper / white waste etc and surface finished to match the existing surface & colour.
(a) One light/fan/exhaust fan point controlled by one switch.
(b) One 5 pin 5 Amp switch socket combination point on an independent board.
(c) One 5 pin 5 Amp socket point controlled by one switch on same board.
All as per item 46 above but for one 15 Amp 6 Pin switch socket combination independent with 4 Sqmm FRLS unsheathed copper conductor single core multistranded complete all as specified and directed.
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed.
Fixing only switch piano flush type 5 Amp single pole one way complete all as specified and directed.
S&F switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed.
S&F switch socket combination 5 in 1, 5/15 Amp flush type complete all as specified and directed.
M & L lamp holder PVC/Polycarbonate type insulated body with back plate angle type for batten fittings complete all as specified & directed.
Supply and fix electronic fan regulator 5 stepped type complete all as specified and directed
S&F ceiling rose PVC / Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable in & including concealed PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 4 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 6 sqmm FRLS one run of 4 sqmm FRLS copper conductor & one run of concealed conduit pipe shall be measured as one unit length.)
Supply and fixing in renewal of VTPN DB suitable for Mounting MCCB as Incomer of rating 63 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed.
Supply and fixing in renewal MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed. (Make : Legrand cat part No 5076 11 or equivalent model as specified make as approved by GE)
S&F in renewal of MCB SPN 16-40 Amp, 240 volt, 'C' curve, 10 KA complete all as specified and directed
S&F MCB in renewal of MCB SP 6 to 32 Amp 240 Volt 'C' curve, 10 KA complete all as specified and directed.
Supply and fixing LED lights fitting 1 x 20 W, 220 V, AC decorative box type with dirver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode of size 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Shree Gopal Engineers & Contractor
M/S S P CONSTRUCTION
milan enterprises
kpenterprises
M/S SRI JAGDAMBE TRADERS
M/s Moti Babu Agarwal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .