Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.2 L+₹3.1 L (7.54%)Rejected-Finance 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹44.3 L+₹3.2 L (7.78%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L3 | Rejected-Finance Not being lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Biddeer not enlisted in apprppriate category |
Tender Value
₹49.5 L
EMD Value
₹98,960
Closing Date
1 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineeer
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-102/2022-2023 REPAIR AND MAINTENANCE OF COOLING APPLIANCES INSTALLED IN VARIOUS UNITS AND REPAIR / MAINTENANCE OF AIR CONDITION VOLTAGE STABLIZERS AND ALLIED EQUIPMENT AT CHANDIMANDIR
2023_MES_584420_1
GE/CHM-102/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹98,960
Yes
23 Jun 2023
4 Mar 2023
8 Apr 2023
4 Mar 2023
1 Apr 2023
18 Mar 2023
Amount
Attending the daily complaints pertaining to ACs three phase at site which includes the following (i) Checking elect circuit, tightening of loose elect connection including internal circuit of plant and ensure the functioning of the plant. Note :- (i) Spare parts if any required shall be measured and paid separately as supply only. (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging, leak testing etc mentioned as S & F/ M & L (iii) Work against entire quantity shall be completed within set schedule to be decided by Engineer-in-charge. (iv) All the plants shall be handed over on daily basis through proper documentation. (v) The deployed tradesman shall have technical qualification in the field and necessary documentary proof shall be produced by the contractor. (vi) For non attendance of complaints within 24 Hrs, penal charges @ Rs 1000 per complaint per day shall be charged. (vii) Thorough care/ protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning. (viii) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost. (ix) Each service shall be measured and paid separately as each job. (x) The technician must have the minimum qualification of ITI in Refg & AC from Recognize institute of Govt Approved
Comprehensive maintenance of AC's (Hot & Cold) of capacity 8.5 Ton ductable ACs of make LG, by disconnecting/ dismantling of indoor and outdoor unit at site and refixing the same after repair/renewal of the defective spare parts (spare parts where required to be replaced shall be measured and paid separetly as supply only). Servicing of the ducts, drain pipe, cooling coil, condensing coil and adjusting the duct slope for free flow of drain water, testing of the complete set of Hot/Cold at desired temperature complete all as specified and as directed. Note:- (i) Gas charging, spare parts shall be measured and paid for separately under respective items. (ii) The contractor shall provide only the experienced and qualified staff for handling the sensitive works. (iii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging, leak testing. (iv) Work against entire quantity shall be completed within set schedule to be decided by Engineer-in-charge. (v) All the plants shall be handed over on daily basis through proper documentation. (vi) Penal charges @ Rs 1000 per plant per day shall be charged for not following the schedule. (vii) Thorough care/ protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning. (viii) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost. (ix) Each service shall be measured and paid separately as each job.
All as per item 2 here-in-before but for 5.0 Ton ductable type AC. Make: Amtrex LG/ Danfoss/ Indofos/ Copeland
All as per item 2 here-in-before but for 4 Ton cassette type / ductable type AC. Make: Amtrex LG/ Danfoss/ Indofos/ Copeland
All as per item 2 here-in-before but for 3 TR cassette type / Pillar type AC. Make: LG/Hitachi
Material for providing insulation on and around suction and discharge copper tube of size 1/2'' and 1/4'', 3/8" and 5/8" with 6 mm thick flexible thermocol heat resistance duly warpped with sticking tape and finally covered with flexible PVC conduit of 50mm dia complete all as specified and as directed.
Supply only of AC 4 Pole power contactor three phase of capacity 25 Amp to 40 Amp suitable for pillar type AC-3 TR/5TR/8.5R complete all as specified and as directed. Make : L&T/BCH/C&S/ABB/Havells
Supply only liquid line drier filter suitable for 8.5 ton ductale AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete all as specified and as directed. Note:- Supply and charging Refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
All as per item 8 here-in-before but for 3 to 5 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos
Supply only of air filter set suitable for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
All as per item 10 here-in-before but for 3 to 5 TR ductable / cassette type AC. Make: Amtrex/ Danfoss/ Indofos
Supply only of low / high pressure switch for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
All as per item 12 here-in-before but for 5 TR/3 TR ductable / cassette type AC. Make: Amtrex/ Danfoss/ Indofos
Taking out unserviceable sealed unit compressor from cassetee/ pillar type air conditioner by disconnecting cooling and condensor copper pipe and electric connection carefully and Supply and fixing new scroll compressor of capacity 3 ton including charging of refrigerant gas R-22 upto required cooling and connecting all the copper pipes, electric connection and testing the AC complete all as specified and as directed. Make : LG/ Danfoss/ Sanyo/ Tecumseh/Kirloskar/ Comipro/Copeland NOTE : Supply and charging refrigerent gas will be measured and paid separately under relavent items
All as per item 14 here-in-before but three phase compressor of capacity or 4.25 TR suitable for 8.5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland
All as per item 14 here-in-before but three phase compressor of capacity 5 TR suitalbe for 5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland Note for serial item No 14 to 16 : Supply and charging refrigerent gas will be measured and paid seperately under relavent items
Carrying out pressure leak test of 8.5 ton ductable split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed.
All as per item 17 here-in-before but for ductable any type AC 5.0 Ton Capacity.
All as per item 17 here-in-before but for pillar / cassette / any type AC 3 Ton Capacity. Note for serial item No 17 to 19: Note :-Supply & charging of refrigerant gas R-22 will be measured and paid for separately
Supply only thermal relay 15 A to 30 Amps, 415 Volt, single phase suitable for pillar/ cassette/ductable type AC of 3 TR/5 TR/8.5 TR capacity as per sample complete all as specified and as directed. Make : LG / Hitech/Indo Asian/L&T/Tecumseh.
Supply only PCB (circuit plate) of out-door unit of 8.5 TR ductable split AC complete all as specified and as directed.
All as per item 21 here-in-before but for pillar /ductable/ casette / any type AC 3.0 TR to 5.0 TR
Supply only PCB (circuit plate) of in-door unit of 8.5 TR ductable split AC complete all as specified and as directed.
All as per item 23 here-in-before but for pillar /ductable/ casette / any type AC 3.0 TR to 5.0 TR.
Supply only single phase preventor, 230 volt, 50 HZ, AC supply suitable for 3 to 8.5 TR AC as per sample complete all as specified and as directed. Make : L&T / Seimens / Hagger.
Supply only reverse cycle valve suitable for cassette/pillar type AC of capacity AC 3.0 Ton to 8.5 Ton as per sample complete all as specified and as directed.
Supply only indoor blower motor for cooling coil 1/3 HP, 230 volt, 930 RPM including blower suitable for ductable AC 8.5 TR to 5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only indoor blower motor for cooling coil 1/3 HP, 230 volt, 930 RPM including blower suitable for pillar/ cassette type AC of 3 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only outdoor fan motor suitable for small shaft condensing coil 1/3 HP, 230 volt, 930 RPM including blade suitable for ductable AC of 5 TR to 8.5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only outdoor fan motor suitable for small shaft condensing coil 1/3 HP, 230 volt, 930 RPM including blade suitable for pillar/ cassettte AC of 3 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only drain pump DC 12/24 volt for indoor unit, cassette type AC of 3 TR to 4 TR as per sample complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar/daccan.
Supply only drain pipe of PVC medium grade of 25mm with all accessories like elbow, socket, tees etc complete all as specified and as directed.
Supply only complete wiring kit for outdoor panel of ductable AC of capacity 3 to 8.5 Ton complete all as specified and as directed.
Supply only starter 3 phase ,415V, 40A suitable for ductable AC of cap3 to 8.5 TR complete all as specified and as directed. Make: L&T/BCH/ABB
Disconnecting electric connection from defective blower/ fan motor and taking out from unit capacity 3 to 8.5 TR of existing make and transporting to store yard of Refg AC Section, then to be transported to contractors workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding as per existing gauge wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
Supply only AC contactor single phase 230 volt, 50 Hz, double pole, AC3 rating 25 Amp to 40 Amp, AC1 rating 45 Amps to 55 Amps complete all as specified and as directed.
Supply only AC contactor single phase 230 volt, 50 Hz, double pole, AC3 rating 32 Amp to 50 Amp, AC1 rating 55 Amps to 85 Amps complete all as specified and as directed.
Taking down of defective evaporator unit of 3 TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or as per existing make with evaporator coil blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
Renewal condensing unit of Cassette type AC of capacity 3 TR capacity outdoor unit complete with condensing coil, compressor, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerant gas will be measured and paid for separetly.
Taking down of defective evaporator unit of 4 TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or as per existing make with evaporator coil blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
Renewal condensing unit of Cassette type AC of capacity 4 TR capacity outdoor unit complete with condensing coil, compressor, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerant gas will be measured and paid for separetly.
Vertical three phase distribution board 12 way 440 volts having IP 43 protection with metal double door with provision for fixing of MCCB's as incomer and outgoing MCB TPN complete all as specified and directed and making new electrical connections with thimbles or other suitable arrangements including taking down existing unserviceable DB and making good surface with matching existing surfaces all as specified and directed.
MCB Triple pole & Neutral C curve 63 Amp 10 KA including taking down existing unserviceable MCB complete all as specified and directed
Renewal MCCB, four pole, 300 Amp 415 volts. 50 Hz breaking capacity not less than 36 kA with adjustable thermal and adjustable magnetic protection release with spreader links. Ics = 100% lcu complete all as specified and as directed.
Renewal MCCB, four pole, 160 Amp 415 volts. 50 Hz breaking capacity not less than 36 kA with adjustable thermal and adjustable magnetic protection release with spreader links. Ics = 100% lcu complete all as specified and as directed.
5/8” and 3/8” dia copper pipe including tubular heat/cold resistant rubber pipe insulation complete all as specified and as directed. Note : 1 meter of 5/8" dia copper pipe, 1 meter of 3/8" dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose.
All as per item 46 here-in- before but size 1/2” and 1/4” dia, Note : 1 meter of 1/2" copper pipe, 1 meter of 1/4" dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose.
flair nut of 5/8" and 3/8" dia complete all as specified and as directed.
flair nut of 1/2" and 1/4" dia complete all as specified and as directed.
4 core copper wire size 6 sqmm PVC insulated 1100 volt grade complete all as specified and as directed.
Supply & charging (Topping up) the ductable/ cassette type AC etc with refrigerant gas R-22 in required quantity for desired cooling complete all as specified and as directed. Note:-The contractor should weight on balance of empty/refill cylinder of the refrigerent and refrigerent before/after using in MES store Yard.Electric balance should be provided by the contractor complete all as specified and as directed.
Suction valve/ discharge valve suitable for 4.25, 3 & 5 TR compressor all as specified and as directed.Make:- BAP / TAK Cassel
Supply only remote control hand set for existing window type/ split type air conditioner of make LG/ Samsung/ Voltas/ Bluestar or as per existing and of cap 3 to 8.5 ton with required pencil cells complete all as specified and as directed.
Supply only any type of sensor suitable for AC of 3 TR to 8.5 TR as per sample complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar/daccan.
Dismantling at site for Repair and replace the defective parts to automatic phase corrector panel and reinstalled including S&F Contactor 415 v 300Amps cat pt no.MCE15SN3M7 and testing complete including making electric connection and all as specified and directed by Engr-in Charge.Make BCH or Equivalant
Coil 415 v 300 Amps cat pt no.2-2412-M
Reley minilac 415 V.cat pt no.VSPD1415V.
Magnetic connector 415 V, 25 amps to 63 amps suitable for AC 3 to 8.5 TR and all as specified and directed by Engr-in Charge
Attending the daily complaints pertaining to ACs/ water coolers/ Refrigerator/ Deep freezer and Desert coolers any size / make which includes the following (i) Checking elect circuit, tightning of loose elect connection including internal circuit of plant and ensure the functioning of the qequipment. Note :- (i) Spare parts if any required shall be measuread and paid separetely as supply only. (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging, leak testing which are mentioned as Supply and Fixing/ Material and labour (iii) Work against entire quantity shall be completed within fixed schedule to be decided by Engineer-in-charge. (iv) All the plants shall be handed over on daily basis through proper documentation. (v) The deployed tradesman shall have technical qualified / experience in the field and necessary documentary proof shall be produced by the contractor. (vi) For non attendance of complaints within 24 Hrs, penal charges @ Rs 1000 per complaint per day shall be charged. (vi) Thorough care/ protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning. (vii) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost. (viii) Each complaint shall be measured and paid separately as each job. (ix) The technician must have the minimum qualification of ITI in Refg & AC from Recognize institute of Govt Approved
Repair maintenence of window type Air conditioner/split type air conditioner of1.5/2.0 ton, water cooler/ refrigerator/ deep freezer and desert cooler of any capacity any make any size which include the following :- (i) Taking out the entire unit from the window after unscrewing front cover, packing material, ply or any type of front cover, (ii) Servicing/cleaning the entire unit with elect blower and cleaning with collin or equivalent agent . (iii) Testing and refixing complete all as directed NOTE :- (i) Spare parts if any reqd shall be measuread and paid separetely as Supply only. (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging , leak testing etc mentioned as S & F/ M & L. (iii) Work against entire qty shall be completed in summer season as directed (iv) All the plants shall be handed over on daily basis through proper documentation . (v) Penal charges @ 1000 per plant per day shall be charged for not following the schedule. (vi) Through care / protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning . (vii) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost . (viii) Each service shall be measured and paid separetly as each job
Taking out unserviceable sealed unit compressor from existing window type/ split type air conditioner of capacity 1.5 ton of any make and Supply and fixing new hermetically sealed unit compressor of existing type / make Tosiba/ Carrier/ Kirloskar/ Tecumseh/Whirlpool as per existing make as approved by GE including cleaning & painting the base plate and charging of refrigerant R-410 gas to obtain adequate cooling complete all as specified and as directed.
All as per item 61 here-in-before but of capacity 2.0 ton. NOTE for serial item No 61 & 62 : (i) Regrigerant gas shall be measured and paid separately as supply only. (ii) New compressor shall be brought at site in original packing of manufacturer with complete details of compressor. (iii) New Compressor shall be procured from OEM's authorised dealer/ distributor. Invoice with test certificate shall be produced.
Supply only AC contactor single phase 230 volt, 50 Hz, double pole, AC3 rating 25 Amp to 40 Amp, AC1 rating 45 to 55 Amp complete all as specified and as directed. Make : L&T/ BCH/ C&S/ABB/Havells
Supply only remote control hand set as per existing sample for existing window type/ split type air conditioner of make LG/ Samsung/ Voltas/ Bluestar and of cap 1.5/2 ton with required pencil cells complete all as specified and as directed.
Supply only 2.5 to 10 Mfd running capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.
Supply only 36 to 60 Mfd running capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.
Supply only 40/60,80/100 to 100/120 Mfd starting capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.
Supply only air filter made of Ric/Nylon suitable for split/ window type Air Conditioner 1.5 TR/ 2TR cap. complete all as specified and as directed.Make : Samsung/LG/Voltas/Carrier/GMCC/Whirlpol / as per sample
Supply only kit for window type AC, comprising cooling, condensing coil, fan motor, compressor 1.5TR and electrical accessories, testing complete all as specified and as directed. Make: Opel/ LG/ Voltas/ Viva.
Supply only front grill of window type AC with shutters (as per sample) complete all as specified and as directed.
Carrying out pressure leak test for 1.5/2 TR capacity split/ window type AC by Nitrogen gas pressure for detecting the leakage in condensing & cooling unit, refrigerant pipe and repairing the leakage by welding or brazing, checking the leakage after repairing, flushing out nitrogen gas, vacummnation complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22 will be measured and paid for separately. The cost of Nitrogen gas will be incluidng under quoted rate.
Supply & charging (Topping up) the AC unit of window/split type/ refrigerators / water coolers/ deep freezer etc with refrigerant gas R-22 in required quantity for desired cooling complete all as specified and as directed. Note:-The contractor should weight on balance of empty/refill cylinder of the refrigerent and refrigerent before/after using in MES store Yard.Electric balance should be provided by the contractor complete all as specified and as directed.
Supply & charging (Topping up) the refrigerators / water coolers etc with refrigerant gas R-134 in required quantity for desired cooling complete all as specified and as directed. Note:-The contractor should weight on balance of empty/refill cylinder of the refrigerent and refrigerent before/after using in MES store Yard.Electric balance should be provided by the contractor complete all as specified and as directed.
Supply & charging (Topping up) the cooling appliances etc with refrigerant gas R-410 or R 32 in required quantity for desired cooling complete all as specified and as directed. Note:-The contractor should weight on balance of empty/refill cylinder of the refrigerent and refrigerent before/after using in MES store Yard.Electric balance should be provided by the contractor complete all as specified and as directed.
Supply & charging (Topping up) the cooling appliances etc with refrigerant gas R-600 or R-290 in required quantity for desired cooling complete all as specified and as directed. Note:-The contractor should weight on balance of empty/refill cylinder of the refrigerent and refrigerent before/after using in MES store Yard.Electric balance should be provided by the contractor complete all as specified and as directed.
Material for providing insulation on and around suction and discharge copper tube of size 1/2"and 1/4" with 6mm thick flexible thermocoal heat resistance for split type AC complete all as specified and as directed.
1/2” and 1/4” dia copper pipe including tubular heat/cold resistant rubber pipe insulation complete all as specified and as directed. Note : 1 meter of 1/2" dia copper pipe, 1 meter of 1/4" dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose.
Brass flair nut of 1/2" and 1/4" dia complete all as specified and as directed.
3 core copper wire size 4 sqmm PVC insulated 1100 volt grade complete all as specified and as directed.Make : Finolex/ Rallison/ L&T/ Grandlay
Supply only swing motor for 1.5 TR /2 TR split AC indoor unit for any type and make complete all as specified and as directed. Make: LG / Carrier / Voltas
Supply only cooling coil motor 1/35 HP, three speed, single phase, 230 volt 50 Hz suitable for split AC 1.5/2 ton complete all as specified and as directed. Make:Carrier/LG/Samsung/Daikin.
PVC flexible pipe 15 mm dia for condensed water drain out complete all as specified and as directed.
Unscrewing defective PCB and supply & fix PCB universal type with remote for suitable for any type of window/split AC capacity of 1.5/2 TR as per sample complete all as specified and as directed.
Unscrewing defective PCB and repair in auth electronic work shop and fixing the same and testing for any type of window/split AC capacity of 1.5/2 TR complete all as specified and as directed.
Taking down of existing window type AC from its location and refixing in new location including wall/window cutting,packing material,ply cover etc and testing after installtion and making good to disturb surface area complete all as specified and as directed.
Taking down of existing spilt type AC from its location and refixing in new location including wall cutting chasing etc and testing after installtion and making good to disturb surface area complete all as specified and as directed.
Supply only metalic stand wall mounted suitable for AC out door unit as per sample complete all as specified and as directed.
Supply only metalic tray suitable for drain water collector of window AC unit all as per existing size and sample complete all as specified and as directed.
Supply only suction / discharge valve size 1/2" and 1/4'' for 1.5/ 2 TR split AC complete all as specified and as directed.Make:- BAP / TAK Cassel
Reverse valve suitable for 1.5/ 2 TR window type AC/split type AC for convert the mode from cool to hot air flow complete all as specified and as directed.Make:- BAP / TAK Cassel
Renewal outdoor condensing unit of spilt type AC of capacity 1.5 TR capacity complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay, compresssor unit, Fan motor with blade complete all as specified and as directed.Make :- Opel/ Accent/ Skoda/ LG/ Carrier/ Blue stat/ Hitachi
Replacement defective indoor unit of 1.5 TR capacity split type AC Evaporator coil, PCB, hand remote, blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same complete all as specified and as directed. Make : Opel/Accent/Skoda/LG /Carrier /whirlphol /Blue Star/ hitachi
Replacement outdoor condensing unit of spilt type AC of capacity 2 TR capacity complete with sealed compressor unit,condensing coil made of copper pipe, coil frame, wiring kit, starting and running capacitor, relay, compresssor unit, Fan motor with blade complete all as specified and as directed.Make :- Opel/ Accent/ Skoda/ LG/ Carrier/whirlphol/Blue star/Hitachi
Replacement defective indoor unit of 2 TR capacity split type AC with evaporator coil,PCB, blower motor, front grill,hand remot and connecting the copper tubing by brazing, detecting leakage, rectifying the same complete all as specified and as directed. Make : Opel/Accent/ Skoda/LG/Carrier /whirlphol/ Blue Star/Hitachi
Supply only any type of sensor suitable for AC of 1.5 TR to 2 TR, as per sample complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar/daccan.
Detecting any leakage from cooling and condensing coil of water cooler capacity 40/80L of any make with the help of high pressure nitrogen gas and repairing the leakage by welding / brazing of cooling and condensing coils including renewal of filter, capillary tube and testing the unit complete all as specified and as directed.
All as per item 96 here-in- before but for 60/120L capacity.
All as per item 96 here-in- before but refrigerator for 165/240/300/310 Ltr of any make
All as per item 96 here-in- before but deep freezer for 100/625 Ltr of any make Note for serial item No 96 to 99 : Supply & charging of refrigerant gas shall be measured and paid for separately
Taking down old unserviceable compressor of any make/ model from water coolers cap 40/80L of Make : Sidwal/ Voltas/ Usha/ Blue star & Supply and fixing new sealed compressor, replacing liquid line filter and capillary tube suitable for refrigerant with necessary brazing work, flushing the cooling including charging of refrigerant R-22/R-134 to obtain adequate cooling complete all as specified and as directed. Make : Kirloskar / Tecumseh / Godrej /Copeland. Note : Supply & charging of refrigerant gas shall be measured and paid for separately.
All as per item 100 here-in- before but for capacity of water coolers 60/120L compressor Model No. 2612. Make : Kirloskar / Tecumseh / Godrej /Copeland.
All as per item 100 here-in- before but for deep freezer of capacity 100/300/325 L compressor Model No. 2425. Make : Kirloskar / Tecumseh / Godrej /Copeland.
All as per item 100 here-in- before but for refrigerator 165 to 240 Ltr of any make. Make of Comressor: Godrej/Usha/Tecumseh/LG/Copeland
All as per item 100 here-in- before but for refrigerator 285 to 310 Ltr of any make. Make of Comressor: Godrej/Usha/Tecumseh/LG/Copeland Note for seril item No 100 to 104 : Supply & charging of refrigerant gas shall be measured and paid for separately.
Supply only rubber waste pipe /drain pipe minimum 1 meter length with clamps suitable for water cooler any capacity complete all as specified and as directed.
Renewal, condensing coil for water cooler capacity 40/80L of any make and charging refrigerant R-134/R-22 to obtain adequate cooling complete all as specified and as directed. Note- Supply and chargeing of refigerant gas shall be measured and paid for separatly.
All as per item 106 here-in-before but 60/120 ltr capacity.
Renewal, condensing coil for refrigerator 160L to 210 ltr capacity including disconnecting condensing coil from refrigerator, Nitrogen Pressure testing and flushing out the system and charging of refrigerant gas up to required cooling level complete all as specified and as directed. Note- Supply and chargeing of refigerant gas shall be measured and paid for separatly.
Renewal, condensing coil for refrigerator 285/310 ltr capacity including disconnecting condensing coil from refrigerator, Nitrogen Pressure testing and flushing out the system and charging of refrigerant gas up to required cooling level complete all as specified and as directed. Note- Supply and chargeing of refigerant gas shall be measured and paid for separatly.
Supply only starting relay for refrigerator of any capacity complete all as specified and as directed.
Supply only over load protector for refrigerator of any capacity complete all as specified and as directed.
Supply only thermostat ISI marked for refrigerator of any capacity complete all as specified and as directed.
Supply only defrost heater ISI marked for refrigerator of any capacity complete all as specified and as directed.
Supply only Biometal/timer ISI marked for refrigerator of any capacity complete all as specified and as directed.
Supply only freezer with cooling coil for refrigerator as per sample of any capacity complete all as specified and as directed.
Unscrewing defective PCB and replace in new Supply & fix PCB as per sample for suitable for any type of invertor refrigerator of any capacity complete all as specified and as directed.
Unscrewing defective PCB and repair in auth electronic work shop and fixing the same and testing for any type of invertor refrigerator of any capacity complete all as specified and as directed.
Supply only , flot valve complete including ball, brass rod,on off tap 15 mm dia suitable for Water cooler all as specified and as directed.
Supply only , tap push type any type outer/inner threaded15 mm dia suitable for Water cooler all as specified and as directed.
Supply only , metalic Top cover as per existig size and sample suitable for Water cooler all as specified and as directed.
Supply only , metalic water collector tray as per existig size and sample suitable for Water cooler all as specified and as directed.
Supply only , top plug 3 pin 5 Amp in white colour complete all as specified and as directed. Make : SSK / CONA / FINE/ Anchor
Supply only , top plug 3 pin 15 Amp in white colour complete all as specified and as directed. Make : SSK / CONA / FINE/ Anchor
Renewal submersible water lifting pump 18 watt 165-240 volt 50 Hz for desert cooler complete all as specified and as directed. Make : Khaitan / Crompton/ Symphony
Renewal PVC water pipe with PVC distributor & PVC elbow for desert cooler complete all as specified and as directed.
Renewal wood wool Cooler Pad set of Three of any size with khas khas grass having weight of 500 gms each set for desert cooler complete all as specified and as directed.
Replacement of desert cooler fan motor, copper wound, single phase, 50 Hz, 230 volts ,motor holding clips/ brackets etc complete all as specified and as directed Make : KHAITAN / BAJAJ / CROMPTON GREAVES.
Renewal MS Front Show grill as per exisitng size at site for desert cooler complete all as specified and as directed.
Replacement metalic fan Blades for desert cooler motor fan clock/anticlock wise complete all as specified and as directed.
Replacement to the broken PVC outer body of desert cooler complete in all respect ( including Front Show grill,three nos of door, four nos lag for holding of motor,switch piano, switch rotary,plate/patti,logo screw,nut bolt etc) with out motor and lifting pump all as specified and as directed.
Replacement to the coroded metal outer body of desert cooler made of 22 guage of sheet, 20 ltr capacity of water bucket complete in all respect ( including Front Show grill,three nos of door, four nos lag for holding of motor,switch piano, switch rotary,plate/patti,logo, screw,nut bolt etc) with out motor and lifting pump all as specified and as directed.
Fabrication the stand size as per sample suitable for desert cooler made of matalic angle iron 25 x 25 x 3 mm all as specified and as directed.
Supply and installation voltage corrector for automatic operation including taking down unserviceable voltage corrector, 2 to 3 KVA single phase naturally air cooled with electronic time delay relay, input between 170 volt to 250 volts, out put voltage at 230 volt with accuracy of +/- 2.5% complete all as specified and as directed Make : POWERWARE, AE, ANDREW YULE, APLAB, V-GUARD, ITE GURGAON VINITEK, VOLINA, BRENTFORD, MICROTECH, Sinetrac, Carrier
Supply and installation voltage corrector for automatic operation including taking down unserviceable voltage corrector, 4 to 5 KVA single phase naturally air cooled with electronic time delay relay, input between 170 volt to 250 volts, out put voltage at 230 volt with accuracy of +/- 2.5% complete all as specified and as directed Make : POWERWARE, AE, ANDREW YULE, APLAB, V-GUARD, ITE GURGAON VINITEK, VOLINA, BRENTFORD, MICROTECH, Sinetrac, Carrier
Repair to voltage corrector in auth work shop 2 to 5 KVA single phase including replacement the spares i.e. relay, volt meter, diod,fuse, indicator etc to make input between 170 volt to 250 volts out put voltage at 230 volt with accuracy of + 2.5% complete all as specified and as directed. Make : POWERWARE, AE, ANDREW YULE, APLAB, V-GUARD, ITE GURGAON VINITEK, VOLINA, BRENTFORD, MICROTECH, Sinetrac, Carrier
Replacement single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB 20 Amp, 240 volts, having breaking capacity 10 kA, 'C' Curve complete all as specified and directed.
Point wiring with two single core PVC insulated, unsheathed, FRLSH type, 1100 volts grade, multistranded copper conductor cable 4 sqmm in and including non metallic rigid PVC casing caping/conduit ISI marked with box and sheet all connected accessories including one single core multistanded PVC insulated FRLSH type, 4 sqmm copper conductor cable unsheathed as earth continuity cable from DB to cooling appliances point complete all as specified .
Switch piano flush type, single pole, 230 volt one way , 15 Amps all as specified and directed.
Socket out let 2 in 1, 5/15 Amps, ISI marked, 230 Volts compete all as specified.
Cutting chasing in wall/roof/ floor laying for drain pipe/coper pipe/wiring and making good the disturb area as existing to match all as specified and directed.
Modular box for AC including MCB SP 20 Amps, socket 16 Amps, pin top 3 pin 16 Amps, protected socket 4 module short circuit breaking capacity 3KA MCB,and dummy plate, 215 volt AC 50 hz complete all as specified make Havells/Cona or equivalant
u and v engineers and consultants
Horizon Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .