Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹1.1 Cr Quoted ₹1.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.3 Cr+₹8.5 L (7.21%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹1.3 Cr+₹8.5 L (7.21%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.3 Cr+₹11.6 L (9.85%)Rejected-Finance | ₹1.3 Cr+₹11.6 L (9.85%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹1.3 Cr+₹11.8 L (9.99%)Rejected-Finance | ₹1.3 Cr+₹11.8 L (9.99%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹1.3 Cr+₹12.0 L (10.2%)Rejected-Finance | ₹1.3 Cr+₹12.0 L (10.2%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
22 Feb 2023, 6:00 pmClosed
CWE NO 2 DELHI CANTT
HQ CWE No 2 Delhi Cantt-10
SPL REPAIR TO BLDG NO T-08 T-10 T-12 T-13 AND ROOF TREATMENT OF BLDG NO P-59 P-61 OTM ACCN AT EME WKSP UNDER GE (WEST ) DELHI CANTT-10
2023_MES_572887_2
CWE/WEST-46/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE WEST DELHI CANTT
as per tender documents
9 documents required · 9 mandatory
₹1,000
GE WEST DELHI CANTT-10
₹2.2 L
Yes
23 Mar 2023
27 Jan 2023
24 Feb 2023
27 Jan 2023
22 Feb 2023
9 Feb 2023
Amount
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section framed work complete all as specified and directed.
Dismantling of 100 mm dia Cast Iron pipe (Soil/waste/vent) with fittings from walls, on floors & from trenches if required including taking out any type of joints complete all as specified and directed.
S&F 100 mm dia (bore of pipe) cast iron (sand cast) soil,waste and vent pipe in any length , with or without ears with lead joint and wal/ floor complete all as specified and directed.
Taking down eves gutter and rainwater pipes (any size or pattern) including all fittings heads, shoes, bends, swan necks etc including cleaning or refixing or removel to store complete all as specied and directed.
M & L Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of Thickness 0.80 mm zinc coating 275 complete all as specied and directed.
S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including all necessary extra joints and stack clamps stay including bolts and nuts including dismantaling old complete all as specified and directed
S&F PVC (SWR) shoe to 110mm bore pipes including all necessary joints complete all as specified and directed.
M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (coating of sheet not less than 150 GSM) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, slightly/completly rounded or chamford as per site requirement fixed with self tapping screws complete all as specified and directed.
M&L for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick (coating of sheet not less than 150 GSM) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, hard and dense soil getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B2 using 40 mm gradedaggregate as foundation complete all as specified and directed .
Dismantling wrought iron or mild steel work of any description not otherwise provided for concerete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
S&F mild steel framed work such as grills grating etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars barred iron doors, laddewrs framed balustrers walkways railings frame work for roof covering & similar confirming to Fe 290 Gde-E-165 complete all as specified and directed.
M&L for base plate in bottom 10mm thick and jointing complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section, frame work for chajja with gusset plates, rails, braces and similar work etc complete drilled for fixing of steel sheeting or other covering. confirming to Fe 410-W (Gde-E-250) quality 'A' complete all as specified and directed.
S&F Mild steel, plain, black sheet 1.6 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, pipes or flat sections) including distance pieces, cleats etc conforming Fe 410-W (Gde-E-250 quality -A) complete all as specified and directed.
M&L for complete removal of old steel surface of any description over 10cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coats of red oxide primer including removing of existing paint with paint remover or suitable chemical complete all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down wooden/steel chowkhats/door/ventilator frame including shutter (without taking off shutter) not exc.1.5 Sqm each complete all as spd & directed.
M&L for powder coating (minimum thickness of powder coating 50 micron) aluminium frame section for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F Powder coated aluminium, windows and ventilators shutters, side hung type with out sash bar, aluminium sections weighing not less 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber packing , anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long, hinges type B-21 100mm long and suitable handles ect complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm with stainless steel wire staples, wooden beading etc complete all as specified and directed.
S & F 4 mm thick sheet tinted glass, ordinary quality glazing with rubber gasket in complete all as specified and directed.
M&L for powder coated aluminium grill of powder coating of minimum 50 micron with aluminium mesh of size 50 mm x 50mm with square tube solid 6mm thick including aluminium channel of suitable size complete all as specified and directed at site.
Taking down door/window frames with shutters exc 1.50 sqm but not exc 4.00 sqm each (without taking off shutters from frame) all as specified.
S&F Powder Coated aluminium, door with door frame of 96.6mm X 44.8 mm X 1.6 mm thick and shutter with styles 84.0mm x44.7mmX1.6mm thick rails 101.60mmX44.88X1.6mm thick incl 6mm glass of make Modi/Atul and Partly/fully fixed with 12mm thick prelaminated particle board fixed with aluminium snap beading and rubber gasket. The each shutter fitted with 02 Nos tower bolt 200 mm, 04 Nos handle 150mm and two hydraucally floor spring & mortice lock of approved make all as specified
Taking down wooden/steel shutters from frames and re-fixing including alteration in same opening exc 2 sqm complete all as specified and directed.
Taking down wooden/steel shutters from frames exc 2 sqm complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including internal layer of terrazzo dado and mortar bedding removing rubbish of the premises complete all as specified and directed.
M&L for vitrified tile of size 600mmx 600mmx8mm thick joint free light shade (square/rectangular) area of each tile n.exc 0.36 Sqm in floors etc set and jointed in neat cement slurrry and pointed in coloured cement to match over 15 mm thick scereed bed in CM 1:6 etc. complete .
All as per item no 33.00 here-in-before but on vertcal surfaces with 10 mm thick back rendering in CM 1:4 .
M&L for Coloured Cement concrete reflective type chequered tiles 30cm X 30cm X 25mm thick machine pressed; set jointed and pointed in neat cement slurry in floors and cut and pointed with white cement and pigment including 20mm screed bed in CM 1:6 including dismantling of existing tiles or cement mortar beddding of any thick ness complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20 to 25 mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the floor including rubbing and polishing over and including 20mm screed bed in CM 1:6 including dismantling of existing tiles or cement mortar beddding of any thick ness complete all as specified and directed.
All as per item no 36.00 here-in-before but on vertical surfaces with 10 mmthick back rendering in CM 1:4 ..
Demolition of cement concrete (unreinforced) in ground floor and paving not exc. 15cm thickness (below or above ground level) complete all as specified and directed.
M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D2 (using 40mm stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for 50mm thick sand cushion/sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for Machine pressed coloured reflective type pre cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade, complete all as specified and directed.
M&L PCC (1:3:6) type C2 (using 20mm stone aggregate) as in floors/pavings /plinth protection etc, finished even and fair (75mm thick) with using extra cement.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, AC sheet etc.) or insulation boards/ slabs/blankets, any thickness, including cover fillets any description fixed in any position complete all as specified and directed.
Providing & fixing false ceiling at all height with GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and patterns (with semi perforated 12mm thick micro tegular edged GRG false ceiling tiles) having moisture content less than 2% humidity resistance of 99%. NRCO 50 TO 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams per sqm including both sides) comprising of maint runners of size 15 x 32 mm of length 1200mm of secondary intermediate cross-T of size 15 x 32 mm length 600mm to from grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanising @ 80 gram per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners 6mm dia fully threaded hanger rod upto 1000mm length and L Shape level adjuster of size 85 x 25 x 2mm. Galvanised iron perimeter wall angel of size 24 x 0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to center and 40mm long drywall wood screws. The work shall be carried out as per specification, drawing and as per directions of Engineer-in-Charge.
BLANK
Demolition of brick work built in Cement mortar and removing the debries out side MoD land complete all as specified and directed.
M&L brick work built in cement mortar 1:4 using sub class 'B' bricks(using old size brick) straight or curved on plan exc 6 mtr mean radius using old size bricks complete all as specified and directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in cement or cement lime mortar; not previously plastered; and scrubbing down with water etc. to receive plaster complete all as specified and directed.
M&L 15 mm thick rendering of ready mix mortar(CM 1:4) of approved make of external wall surface finished fair even and smooth without using extracement as whole or in patch complete all as specified and directed ..
Taking down of cement plaster of any description on brick or stone walls/ceiling including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L 15 mm thick rendering of ready mix mortar (CM 1:6)of approved make of internal wall surface finished fair even and smooth without using extracement as whole or in patch complete all as specified and directed ..
M & L for preparation of newly plastered surface of walls applying two coats of oil bound distemper over a coat of primer complete as specified and directed.
M&L for applying Two coats of 100% Premium acrylic emulsion(Weather coat) paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over putty not less than 1.0 mm complete all as specified and all as directed by Engr-in-Charge .
Demolition of reinforced cement concrete of any description and in any position including rubbish removal out slide of rubbish of of the premises complete all as specified and directed.
M & L for providing, cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates including form work complete all as specified and directed.
M&L for TMT bars 10mm dia , and over cut to length bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed.
M&L for TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders cut to length bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed.
Dismantling of brick tiles or terraing tiles single layers as on roof. Complete all as specified and directed.
Demolition of mud in roof any thickness incl plastering and leeping etc amd removal beyond mod land complete all as specified and directed.
M&L for wire brushing and cleaning top surface of existing roof surface, including flashings and junction of parapets, etc. complete all as sepcified and directed.
M&L PCC 1:2:4 type B0 (using 12.5 mm graded stone agg) cement concrete as in roof padding etc.complete all as specified and directed.
M&L for 10mm thick screed bed in CM 1:4 with water proofing liquid as per manufacturer instructions when concrete is a still green etc complete alll as specified and directed. (Note:- Water proofing liquid shall be measured and separately)
M&L for applying a coat of bitumen primer confirming @0.50 ltr/ Sqm on prepared surface of plaster and applying a coat of hot blown bitumen 85/25 gde @1.2 kg/sqm and applying APP based Polymeric membrane minimum weighting 3.5kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt.not less than 150 grm/ sqm) and sealing joints by torched application complete all as specified and directed. (Note: Work be done through approved applicator only)
Supply only Liquid water proofing compound, complete all as specified and directed.
Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. complete all as specified and directed.(Note: Work be done through applicator approved)
S&F 15 mm bore steel water tubing medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors including cutting chases, pinning in brick wall cutting n.exc 10 cm girth and making good to facings where required and pointing in CM 1:3 including taking out old pipes complete all as specified and directed.
S&F GI tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors 20 mm bore including taking out old pipes complete all as specified and directed.
S&F in repair 1000 ltrs capacity rotational molded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & 20mm dia tank nipple suitable for HDPE water tank, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc.
M & L Concealed Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/on surface conduit for ceiling/truss/columns portions etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor,including fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing modular switches , socket outlet and fan regulators etc , all as specified and directed for the followings:-
(a) One light/Fan/Exhaust Fan point controlled by one switch
(b ) One socket outlet point 5 Amps on independendent board
(c ) One socket outlet point 5 Amps controlled by one switch on same board along with other switches.
All as per item No 72.00 here-in-before but with 2 core copper conductor cable FLRS 2.50 sqmm for one 3 pin modular socket outlet,15 Amps concealed and including provision of 2.50 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
All as per item No 72.00 here-in-before but with 2 core copper conductor cable FLRS 4.0 sqmm for one 3 pin AC Box outlet, 20 Amps concealed in wall and including provision of 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor.
Supply and fix switch modular type single pole one way 6 Amps all specified and as directed.
Supply and fix modular socket 5 pin multi purpose 6 Amps flush type .
Supply and fix modular socket multi purpose 2-in-1, 6 pin 6/16 Amps 2 module.
Supply and fix modular switch 16 Amps one module single pole one way.
Supply and fix modular ceiling fan regulator,step type for ceiling fan 120 W 2 module .
S&F ceiling rose surface PVC 65x50 mm type with three terminals.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts ,220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with MS angle bracket,clamp,fastner of suitable size complete all as specified and directed.
Taking down MCBs/ DBs of any type and make all as directed by Engr-in-charge
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 4 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed.
Supply and fix DB TPN 4 way verttical, IP - 43 Protection double door 440 V AC 50Hz with for MCCB 125 Amp,4P as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed.
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete AC Box with one double pole MCB 20 Amp.
Supply and fix MCB SPN 40 To 63 Amps 240 volts 10 KA 50 HZ C curve complete.
Supply and fix MCB SP 5 to 32 Amps 240 volts 10 KA 50 HZ C curve complete.
Supply and fix MCB SPN 63 Amps 440 volts 10 KA 50 HZ C curve complete.
Supply and fix MCCB 125 Amps ,3P ,440 volts 16 KA 50 HZ complete.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with metallic blades, and frame including metallic louvers shutter complete fixing with 4 nos of hole fastners all as specified and directed.
M&L for breaking old existing wall and making provn of a round hole for fix of 450 mm sweep exhaust fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
M&L for XLPE insulated, heavy duty electric cable with stranded aluminium conductor,1100 volts grade of cross sectional area 16 Sqmm, 4 Core laid in trenches/fixing on wall (with GI Clamps and screws on wooden gutties)/poles or passing through pipe including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing complete all as specified and directed.
Taking down fan, Ceiling cable end, dismantling blades and removing fan and blades to store and refixing the same after the repair all as directed.
M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F ceiling fan blade 1200 mm sweep made up of aluminium body having provision of free size monting nuts/screw all as per requirement at site complete all as specified and directed.
Taking down of wall mounting fan of 450 mm sweep size carry out necessary repair ,dully cleaned and refixing the same on site all as specified and directed.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including PVC conduit for submain wiring and connection complete including PVC unsheathed copper conuctor cable of 4 Sqmm size S/C as earthwire, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories Concealed in walls/surface on ceiling and column,beam all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point earth plate surrounding use of charcoal dust and salt in layer including excavation and earth work , GI pipe 20 mm dia light grade for watering with wire mess and funnel and GI pipe 15 mm dia medium grade for protection of earth lead complete upto main TPN DB making of PCC earth pit using 1:2:4 type B1 using 20mm dia stone aggregate provision of MS PIT cover 300mm x300mm with handle complete all as specified or indicated including testing on completion all as directed.
A R construction
MINHAS CONSTRUCTIONS
M/S SHRINARAYAN MEENA
Shiv Shankar Nirman Co.
CHOPRA BUILDERS
Vipul Construction
L G BUILDERS
M/s M M BAHL
SHREE RAM BUILD TECH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .