Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹47.8 L+₹3.4 L (7.55%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest bidder | |
| 3 | L3₹50.0 L+₹5.5 L (12.4%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest bidder | |
| 4 | L4₹50.0 L+₹5.5 L (12.4%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest bidder | |
| 5 | L5₹50.0 L+₹5.5 L (12.4%)Rejected-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L5 | Rejected-Finance Being other than lowest bidder |
| Sl No | Description | Qty | Unit | L and S ENTERPRISES L7 | MS ENTERPRISES L8 | Mavee Syndicate L5 | V.H.Constructions L1 | M/s. A&T Enterprises L4 | M. Laxman Rao and sons L6 | THE DECAN ENGINEERING AND REFRIGERATION COMPANY L11 | GANGARAJU ENTERPRISES L3 | VS ENTERPRISES L9 | Srinivash Engineers L10 | SRI SAI RAM ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/ underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- | ||||||||||||||
| 1.01 | Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.
Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose. | 50 | Each | 300 ₹15,000 | 293 ₹14,650 | 200 ₹10,000 | 450 ₹22,500 | 250 ₹12,500 | 285 ₹14,250 | 200 ₹10,000 | 275 ₹13,750 | 302 ₹15,100 | 150 ₹7,500 Lowest | 350 ₹17,500 |
| 1.02 | Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply.
Note :-
(i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately.
(ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes. | 50 | Each Job | 600 ₹30,000 | 633 ₹31,650 | 500 ₹25,000 | 880 ₹44,000 | 540 ₹27,000 | 575 ₹28,750 | 200 ₹10,000 Lowest | 550 ₹27,500 | 598 ₹29,900 | 200 ₹10,000 Lowest | 675 ₹33,750 |
| 1.03Notes for Item Nos 1.01 to 1.02 :- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/ her for completion of day to day complaint within 24 Hrs from the time of reporting.Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/ non-completion remarks from users/ MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify auth rep/ Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/M, Secunderabad and the same shall be submitted to E/M No II store on daily basis. | ||||||||||||||
| 2.00 | M&L for ACSR conductor, steel reinforced for LT over head lines on poles including stretching tightening of poles insulator with binding wire of suitable size with insulator/ stretching of ACSR conductor including disconnecting/ taking out old existing unsv ACSR conductors complete all as specified and directed. | 2 | Qtl | 21,000 ₹42,000 | 21,533 ₹43,066 | 19,500 ₹39,000 | 5,000 ₹10,000 Lowest | 20,430 ₹40,860 | 21,400 ₹42,800 | 22,000 ₹44,000 | 19,000 ₹38,000 | 21,450 ₹42,900 | 12,400 ₹24,800 | 21,000 ₹42,000 |
| 3.00 | M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/ taking out old existing unsv insulators complete all as specified and directed. | 20 | Each | 300 ₹6,000 | 233 ₹4,660 | 294 ₹5,880 | 850 ₹17,000 | 290 ₹5,800 | 350 ₹7,000 | 200 ₹4,000 Lowest | 270 ₹5,400 | 289 ₹5,780 | 200 ₹4,000 Lowest | 250 ₹5,000 |
| 4.00 | M&L for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/ taking out old existing unsv insulators complete all as specified and directed. | 20 | Each | 180 ₹3,600 | 193 ₹3,860 | 150 ₹3,000 Lowest | 700 ₹14,000 | 170 ₹3,400 | 195 ₹3,900 | 200 ₹4,000 | 190 ₹3,800 | 176 ₹3,520 | 200 ₹4,000 | 150 ₹3,000 Lowest |
| 5.00 | S&F in replacement Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/ mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/ bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, up to 50m including disconnecting/ taking out old existing unsv stay assembly complete all as specified and directed. | 4 | Per Set | 2,500 ₹10,000 | 2,533 ₹10,132 | 2,200 ₹8,800 | 2,900 ₹11,600 | 2,400 ₹9,600 | 2,390 ₹9,560 | 2,000 ₹8,000 | 2,445 ₹9,780 | 2,453 ₹9,812 | 1,200 ₹4,800 Lowest | 2,400 ₹9,600 |
| 6.00 | S&F in replacement of Galvanised steel wire (GI) 4mm dia including disconnecting/ taking out old existing unsv GI wire complete all as specified and directed. | 100 | RM | 20 ₹2,000 Lowest | 33 ₹3,300 | 40 ₹4,000 | 45 ₹4,500 | 24 ₹2,400 | 22 ₹2,200 | 20 ₹2,000 Lowest | 22 ₹2,200 | 24 ₹2,400 | 90 ₹9,000 | 20 ₹2,000 Lowest |
| 7.00 | M & L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/ taking out old existing unsv cross arms complete all as specified and directed. | 4 | Qtl | 15,000 ₹60,000 | 14,893 ₹59,572 | 17,000 ₹68,000 | 10,000 ₹40,000 | 1,350 ₹5,400 Lowest | 14,940 ₹59,760 | 14,000 ₹56,000 | 16,400 ₹65,600 | 15,300 ₹61,200 | 11,000 ₹44,000 | 15,000 ₹60,000 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
11 Jun 2026, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE (U) Secunderabad, Mudfort - 500003
REPAIR/ MAINTENANCE OF LT DISTRIBUTION SYSTEM, HIGH MAST AND ASSOCIATED CONTROL GEAR, LIGHTS AND ALLIED WORKS AT AOC CENTRE, 54 DOU, SAFILGUDA MD COMPLEXES, 2 MW SOLAR PLANT AND ADJOINING AREA UNDER AGE EM II OF GE(U) SECUNDERABAD.
2026_MES_766724_1
GE (U)/SEC/TOKEN/M12 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SECUNDERABAD
As per tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹96,000
Yes
17 Aug 2026
21 May 2026
18 Jun 2026
21 May 2026
11 Jun 2026
4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/ underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- | |||||
| 1.01 | Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.
Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose. | 50 | Each | 99 | ₹4,950 |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TM12_8615_Tender.pdf
Tender Documents • 0.53 MB
BOQ_858687.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .