Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
18 Oct 2021, 6:00 pmClosed
GE (EAST) FEROZEPUR CANTT
GE (EAST) FEROZEPUR CANTT PIN-152001
Spl repair / replacement of old conventional street light to LED lights at CQMH Abdul Hamid Enclave (MAP-II) and certain sanctioned works under GE(East) Ferozepur Cantt
2021_MES_477123_1
8163/GE/E/FZR/21-22
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (EAST) FEROZEPUR CANTT
₹43,000
Yes
7 Jan 2022
22 Sept 2021
20 Oct 2021
22 Sept 2021
18 Oct 2021
5 Oct 2021
Amount
Excavation in trenches in soft/ loose soil not exc 1.5 m deep and n.exc 1.5 mtr wide for laying of cable,etc. and getting out complete all as specified and directed
Returning, filling in earth including spreading leveling and well ramming excavated soil in layer not exceeding 25 cm thick each layer, back in trenches after cable have been laid & tested,poles,stairs,struts have been erected & tested complete all as specified and directed.
Removing of surplus soil (soft/loose) obtained from excavation to a distance not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and directed
M & L dry and clean fine sand for cable cushioning for cable protection complete all as specified and directed. Note : Punned down thickness shall be measured.
Supply and laying well burnt old size sub class 'B' bricks laid in trenches for cable protection. complete all as specified and directed
Supply & fixing of LED Street light 90 Watt made up of pressure die cast housing with toughned glass Aesthetically designed roadway luminiare with excellent thermal management IP 66 protection complete all as specified and directed Make- KCSAD LED Cat Part No-KDST90 or equivalent makes of Havells/Bajaj as approved by GE.
Disconnecting and taking down unrepairable HPSV/HPMV/MH/ CFL/Tube Light Fittings lamp type street light fitting of any type and capacity from existing 9 mtr swan neck type pole for complete all as specified and directed.
Supply & fixing 3 core 1.5 sqmm PVC insulated and FR PVC round sheathed copper conductor flexible 1100 volts for connection from Junction Box to street light fittings. Make : Havells/Polycab or other equivalent makes as approved by GE
Supply and fix XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor rating 1100 volts cross sectional area 16Sq mm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified and directed.
Supply & fixing street light pole mounted cable junction box IP-65 of Size 250x200x105 for 3 phase /4 core made out of thermal plastic material including bus bar for 3 phase suitable for 16/25 UG sqmm cable including clamps Made out of MS flat 40x5mm including bolts, nuts duly painted and MCB SP 6Amp, including suitable gland for cable entry. etc Including taking out Old unserviceable Junction box and connected item Make : Sintex CAT part No GS-JB-2520 or other equivalant makes as approved by GE
M&L painting and numbering to steel tubular pole of any length and size with one coats aluminium paint including preparation of old painted surface by scrubbing complete all as specified and directed
M&L for Boring of holes under road, pavement, hard standing for laying pipe for crossing cable including getting out, disposal of rubbish off to a distance upto 50 Mtrs including 50 mm GI pipe medium grade. complete all as specified and directed
Supply and fixing automatic street light switch for automatic swithcing of street light/high mast light (timer switch) for Three Phase Load light. The Digital timer 24 hrs alongwith suitable power contractor as per IEC - 60947-4-1 , including incoming & outgoing MCBs,SMC Encloser and support terminal and enclosed in pole/wall mounted factory made PVC enclosure made out of rust proof , shock & termite proof and FRLS grade confirming to IP 54 of capacity 6 KW, Three phase, Current rating 32/TP and MCB rating 40/TPN, having Facility of manual operation. Make- HAVELLS (model - IHXTS03060 or quivalent model of Swdeep/Hansel/Havells as approved by GE.
M&L Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2 using 40 mm graded stone aggregate. The chamber shall be constructed on metre away from edge of earth pit 50mm pre cost cover of cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates and MS angle iron 50x50x6mm frame including two coats of painting over coat of red oxide primere ot exposed steel surface complete all as specified and shown on electried plats No 3 of SSR Part-I - 2009. Note: execution in soft/loose soil returning filling and removal of surplus soil to a distance of 50 metre as directed is included in unit rate.
Material and labour for installation high Galvanized mast light of height 15 m long in two section, 3 mm section thickness, top dia 150 mm and bottom dia 340 mm suitable for 6 to 9 latern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 gauge and double drum winch with luminaire mounting arm, pulley assembly, aviation obstruction light, lightining arrestor spike including RCC/PCC foundation as per manufactures instruction and including automatic street light switch for automatic swithching of high mast light (timer switch) based on lux level of natural light and enclosed in pole/wall mounted factory made PVC enclosure made out of rust , shock, termite proof and FR grade confirming to IP 54 of capacity 5 KW, Single phase , 240 V complete all as specified and directed.Make - CROMPTON / PHILLIPS / BAJAJ as approved by GE. Note: 1. The flood light fittings/ LED 150 Watt shall be measured and paid seperately. 2. The installation of highmast light will be carried out in presence, Rep of manufacturer's.
Supply & fixing of flood light fitting pressure die cast aluminum LED of 150 Watt as light source and electronic driver , made up of pressure die cast housing with toughned glass Aesthetically designed roadway luminiare with excellent thermal management . Make- havells Cat Part :- ENDURAPEARLMAGPLUSSL150W LED757PASYTOTG or eqviualent makes of Phillips / Bajaj as approved by GE
Supply and laying of cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls of size 25 Sqmm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified and directed. Make- havells / Gloster / Universal as approved by GE
Supply and fix Galvanised iron steel tubing light grade of size 40mm complete with all fittings for cable protection complete all as specified and directed
M/s Manoj Construction Co.
M/s Bansi Lal
Karan Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .