Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | ₹1.2 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.3 CrRejected-AOC | ₹1.3 Cr | L2 | Rejected-AOC L1 Being Accepted |
| 3 | L3₹1.4 CrRejected-AOC 03 PATEL STREET GANDHI NAGAR AVADI TIRUVALLUR TAMIL NADU 600054 | THIRUVALLUR | TAMIL NADU | 600054 | ₹1.4 Cr | L3 | Rejected-AOC L1 Being Accepted |
| 4 | L4₹1.4 CrRejected-AOC D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | ₹1.4 Cr | L4 | Rejected-AOC L1 Being Accepted |
| Sl No | Description | Qty | Unit | DJ Group L1 | SREE BALAJI ENTERPRISES L2 | lakshmibuilders L4 | SIVA ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE 'A' (B/R) | |||||||
| 2.00 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as specified and directed. | 2,715 | Sqm | 11 ₹29,865 | 45 ₹1.2 L | 14 ₹38,010 | 27 ₹73,305 |
| 3.00 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:6 complete all as specified and directed. | 1,680 | Sqm | 1,050 ₹17.6 L | 1,260 ₹21.2 L | 1,280 ₹21.5 L | 1,440 ₹24.2 L |
| 4.00 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes with cement mortar 1:6 complete all as specified and directed. | 1,035 | Sqm | 1,250 ₹12.9 L | 1,260 ₹13.0 L | 1,515 ₹15.7 L | 1,260 ₹13.0 L |
| 5.00 | S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B weight of section frame 1.248 kg/m and shutter section weight 0.547 kg/m Jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 4.80/5.0 mm nominal thickness,aluminium wire cloth 0.45 mm dia and average width of aperture 1.4 mm, aluminium alloy handles ,aluminium powder coated any colour deco grill 8 mm dia(75x75mm) etc including taking down old window in any size and make and make good jambs and cills complete all as specified and directed.
Note :- Quoted rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle, 8mm dia aluminium powder coated colour deco grill etc | 324 | Sqm | 8,400 ₹27.2 L | 7,200 ₹23.3 L | 9,700 ₹31.4 L | 7,920 ₹25.7 L |
| 6.00 | Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. | 650 | Sqm | 44 ₹28,600 | 45 ₹29,250 | 65 ₹42,250 | 90 ₹58,500 |
| 7.00 | M&L for 15 mm thick rendering two layers consisting 10 mm thick in CM 1:6 followed by 5 mm thick in CM 1:4 mixed with WPC on fair faces of brick work or concrete surface including finished even and fair all as specified.
Note: WPC shall be measured and paid separately as supply only. | 400 | Sqm | 280 ₹1.1 L | 270 ₹1.1 L | 320 ₹1.3 L | 324 ₹1.3 L |
| 8.00 | M&L for 10 mm thick rendering on internal wall surfaces in cement mortar 1:6 on fair faces incl finished even and smooth w/o using extra cement complete all as specified and directed. | 200 | Sqm | 276 ₹55,200 | 270 ₹54,000 | 300 ₹60,000 | 279 ₹55,800 |
| 9.00 | Supply only Integral waterproofing compound complete all as specified and directed. | 30 | Kg | 122 ₹3,660 | 54 ₹1,620 | 80 ₹2,400 | 63 ₹1,890 |
| 10.00 | M&L for rendering 5mm thick on fair faces of brick work or concrete surfaces with cement mortar 1:3, finished even and smooth (without using extra lime or cement) on ceiling complete all as specified and directed. | 50 | Sqm | 276 ₹13,800 | 270 ₹13,500 | 300 ₹15,000 | 162 ₹8,100 |
Updated dates
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
17 Mar 2026, 6:00 pmClosed
CWE(Navy) Chennai
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai600 009
87740 SPL REPAIRS TO SAILORS IN LIVING C BLOCK AT INS RAJALI ARAKKONAM UNDER GE(M) ARAKKONAM
2026_MES_752140_1
CWE/NAVY/ARK/87740/E8 OF 2025-26
Open Tender
Civil Works
270 days
ARAKKONAM
AS PER NIT TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (M) Arakkonam
₹2.2 L
Yes
10 Apr 2026
10 Feb 2026
19 Mar 2026
10 Feb 2026
17 Mar 2026
3 Mar 2026
10 Feb 2026 - 17 Feb 2026
SCHEDULE 'A' (B/R)
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as specified and directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:6 complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes with cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for 15 mm thick rendering two layers consisting 10 mm thick in CM 1:6 followed by 5 mm thick in CM 1:4 mixed with WPC on fair faces of brick work or concrete surface including finished even and fair all as specified. Note: WPC shall be measured and paid separately as supply only.
M&L for 10 mm thick rendering on internal wall surfaces in cement mortar 1:6 on fair faces incl finished even and smooth w/o using extra cement complete all as specified and directed.
Supply only Integral waterproofing compound complete all as specified and directed.
M&L for rendering 5mm thick on fair faces of brick work or concrete surfaces with cement mortar 1:3, finished even and smooth (without using extra lime or cement) on ceiling complete all as specified and directed.
M &L for applying 2 coats of distemper oil emulsion paint over a coat of primer and putty on wall including preparation of surface by using mechanical tool/ auto roller complete all as specified and directed. Note:- All work shall be carried out by approved applicator of paint manufacturer only. The same shall be approved by GE before carrying out the work.
M &L for Finishing walls with Acrylic Smooth exterior paint of required shade on plastered surface with two or more coats applied @ 1.67 ltr/10 sqm over including priming coat of exterior primer applied @ 2.20 kg/10 sqm and putty by using mechanical tool/auto roller complete all as specified and directed. Note:-All work shall be carried out by approved applicator of paint manufacturer only. The same shall be approved by GE before carrying out the work.
M&L for preparing plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for Complete Removal of existing treatment on wall by vacuum based sanding machine, removal of nails etc & fillng cracks and applying Acrylic Smooth exterior paint of required shade with two or more coats applied @ 1.67 ltr/10 sqm over including priming coat of exterior primer applied @ 2.20 kg/10 sqm and putty by using mechanical tool/auto roller complete all as specified and directed. Note:- (i) Chajja, beam, column to be painted different colour as per Engineer-In-Charge instructions. (ii) All work shall be carried out by approved applicator of paint manufacturer only. The same shall be approved by GE before carrying out the work.
M&L for Complete Removal of existing treatment on ceiling and applying two coats of white wash including preparation of surface complete all as specified and directed.
M&L for Complete Removal of existing treatment on wall by vacuum based sanding machine removal of nails etc & filling cracks and applying two coats of oil bound distemper over one coat of alkali resistant primer and putty by using mechanical tool/ auto roller complete all as specified and directed. Note:- All work shall be carried out by approved applicator of paint manufacturer only. The same shall be approved by GE before carrying out the work.
Taking up or down 20mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 15mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 25mm dia UPVC pipes of pressure rating 10 kgf/cm2 fixed to walls, ceilings or in floors etc., with all fittings complete all as specified and as directed.
S&F 20mm dia UPVC pipes of pressure rating 10 kgf/cm2 fixed to walls, ceilings or in floors etc., with all fittings complete all as specified and as directed.
Taking down eaves, gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning for refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories).
S&F 110mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 75mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110mm PVC (SWR) bends any radius with access door complete all as specified and directed.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each (without taking off shutters from the frames) complete all as specified and directed.
S&F 165x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F 35mm thick second class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F second class hard wood 30mm Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for painting to surfaces of any description, not otherwise descri-bed, over 10cm width, preparation of new wooden surface and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer complete all as specified and directed.
M&L for painting to surfaces of any description, not otherwise descri-bed, over 10cm width, preparation of old wooden surface and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed.
M&L for painting to surfaces of any description, over 10cm in width or girth,not otherwise described inclduing preparation of old steel surfaces and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed.
S&F 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S&F 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 150mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the permises etc., complete all as specified and as directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:6 complete all as specified and directed.
M&L for Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering with cement mortar 1:4 complete all as specified and as directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes,including necesaary repair for existing tanks etc exc 1000 and n exc 2000 ltr complete all as specified and directed
S&F in repairs 19mm dia curtain rods, anodised aluminium alloy including brackets, stops rollers etc., complete all as specified and directed.
S&F in repairs Vitreous China wash basin, white, flat back, size 630x450mm excluding taps, waste, chain and plug and porcelain stopper but including bracket and cutting for pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste complete all as specified and directed.
S&F in repair 75mm PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
S&F in repairs 15mm bore Bib tap fancy type of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm125gms) complete all as specified and directed.
S&F in repairs 15mm bore Pillar taps of fancy type of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-110gms) complete all as specified and directed.
S&F in repairs 15mm bore angle stopcock of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) complete all as specified and directed.
S & F in repairs PVC connection 15 mm size PTMT nuts length 450mm complete all as specified and directed.
S & F in repairs 32mm dia bore PVC waste pipe for wash basin complete all as specified and directed.
Demolition of cement concrete un- reinforced in ground floor & and paving not exceeding 15cm thick, complete all as specified and directed.
M & L for PCC 1:3:6 type C2 75 mm thick (using 40 mm graded aggregate) , as in plinth protection and sub base for paving tiles finishing the surfaces even & fair complete all as specified and directed.
M&L for 100mm thick Cement concrete type D- 2,1:4:8 (using 40mm graded aggregate) complete all as specified and directed.
M&L for sand cushioning/filling under paver block all as specified and directed.
S&F Machine pressed precast Concrete interlocking paver block any shape and size with grey/colour cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 grade all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L for PCC(1:3:6) type C2 (using 40 mm graded stone aggregate) as in surface channels and drain complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds mitred/stopped ends etc. complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge including Nainital or similar pattern in roof covering all as specified and directed.
S & F Pre- painted galvalume aluminIum zinc coating GI based corrugated steel sheet 0.50mm thick of anY colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 300mm, MS ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed.
S&F 150 mm size (Overall length of cover plate) floor door stopper of aluminium body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
Removal of all loose/unsound/bad/damaged concrete or plaster from existing RCC structure of slab/beams/walls by using chisel/hammer, cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplementary bars if required,either by tying it with existing bars or by welding on it. Applying epoxy bonding agent and making good with polymer modified plaster/micro concrete of required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed.
SCHEDULE 'A' (E/M)
Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures, PVC conduits and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials from wall/ceiling etc to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and directed.
Material and labour for Point wiring with 1.5 sqmm (Nominal area) unsheathed FRLS multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into existing concealed conduit through Wall/Ceiling/Floor along with FRLS 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly complete for the following point wiring and making good disturbed surfaces matching with existing paint complete all as specified and directed.
One light/fan point controlled by one switch with cable 1.5 Sqmm size.
one 3 pin socket outlet 5 Amps, on same board with cable 1.5 Sqmm size.
one 3 pin socket outlet 5 Amps, on independent board with cable 1.5 Sqmm size.
All as per item No 66.00 here-in -before but for one 5 pin socket outlet 5/15 Amps, on independent board with cables 2.5 Sqmm size.
One light/fan point controlled by one switch.
one 3 pin socket outlet 5 Amps, on Independent board with cables 1.5 Sqmm size.
All as per item No 67 here-in-before but for one 3 pin socket outlet 15 Amps,on independent board with cables 2.5 Sqmm size.
Supply and fix Modular switch one way 5/6 A white Active one module all as specified and as directed.
Supply and fix Modular socket 5 Amp, 2/3 pin Active white two module complete all as specified and as directed.
Supply and fix Modular switch one way 16 A white Active one module all as specified and as directed.
Supply and fix Modular socket 16 A, 5 pin multi purpose Active white two module complete all as specified and as directed
S&F Ceiling rose three terminals/ PVC/ polycarbonate, isolated body complete all as specified and as directed.
Taking down existing rusted switch board sunken box from site including removing fixtures and fittings such as switch, socket fan regulator complete, removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces necessary plaster, white wash matching with existing colour of wall, floors, etc. all as specified and as directed.
Supply and fixing GI metal flush box suitable for mounting modular plate as per requirement of following modules:-
GI metal flush box, 2 Module
GI metal flush box, 3 Module
GI metal flush box, 4 Module
GI metal flush box, 6 Module
GI metal flush box, 8 Module
GI metal flush box, 12 Module
GI metal flush box, 16 Module
Supply and fixing combined both frame and cover plates, fixing on mounting boxes for following modules:-
Cover plate with frame,1 Module
Cover plate with frame,2 Module
Cover plate with frame,3 Module
Cover plate with frame,4 Module
Cover plate with frame,6 Module
Cover plate with frame,8 Module
Cover plate with frame,12 Module
Cover plate with frame,16 Module
M&L for cutting chases on brick walls/concrete surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carrying out the concealed wiring including necessary finishes all as directed.
Supply and fix high efficiency wall mounted LED light fitting 4 feet white, 20W, integrated LED driver etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old one and taken as credit complete all as specified and as directed.
Supply and fix high performance low wattage Street light not less than 25 Watts LED light fitting ,IP66 protection powder coated pressure die cast aluminium high power street light with heat resisant toughened glass with lens by providing GI pipe medium grade 25 mm dia 1.5 Mtr in length with suitable size MS Clamp two nos made out of 25x3 mm FI incl two coats of synthetic enamel paint over a coat of red oxide primer, prewired and including connecting up with 3 core flexible copper conductor cable of 1.5 Sqmm from ceiling rose to fitting including taking down old u/s damaged fitting all as specified and directed.
Taking down ceiling fans/Exhaust fans of any make and sweep from ceiling hook/existing position complete including disconnecting and transporting to E/M store all as specified and as directed.
Supply and fix ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, frame and louvers complete all as specified and as directed.
Supply and replacement of Metal clad socket single pole and neutral enclosure with a two pin + earth plug top and socket incl taking down old u/s metal clad complete with one double pole 20-32 Amps MCB C Type 230 Volts all as directed.
Taking down sub main wiring along with earth wire of any sizes complete all as specified and as directed.
Material and labour for Sub main wiring with Two runs of single core 4 sqmm for phase and neutral and one run single core 4 sqmm as earth wire with multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade confirming to IS-694 continuity conductor drawn into concealed conduit or non-metallic rigid PVC conduit of minimum 20 mm dia as per site requirement wiring through wall/cable tray/ceiling/floor/roof etc including conduit accessories complete all as specified and as directed. Notes:- (i) The disturbed surfaces shall be made good to match with existing surface including finishes as applicale. (i) Two different color wires shall be used for phase and neutral . (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles . (iv) Three runs of 4.00 Sqmm cable, and one run of PVC conduit will be measured as one unit.
All as per item ser No 84 here in before but Two runs single core 6 sqmm for phase and neutral and one run single core 6 sqmm as earth wire (ie 3X6 Sq mm) complete all as specified and as directed.
All as per item ser No 84 here in before but two runs single core 10 sqmm for phase and neutral and one run single core 10 sqmm as earth wire (ie 3X10 Sq mm) complete all as specified and as directed.
All as per item ser No 84 here in before but Four runs single core 10 sqmm for three phases and neutral and two runs single core 10 sqmm as earth wire (ie 6X10 Sq mm) complete all as specified and as directed.
Supply and fix in repair MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve including taking down old unserviceable MCB complete all as specified and as directed
Supply and fix in repair MCB SPN 230 V, 40-63 Amps with breaking capacity 10KA C curve including taking down old unserviceable MCB complete all as specified and as directed
Supply and fix in repair r MCB TPN 415 V, 40-100 Amps with breaking capacity 10KA C curve including taking down old unserviceable MCB complete all as specified and as directed
S&F DB for MCB SPN 4 way double door DB with 200 amps rated copper bus bar in SS enclosure having IP 43 and IK 09 protection including taking down old u/s DB and MCB's all as specified and directed . Note :- MCB SPN/SP shall be measured and paid under the respective item of the schedule.
S&F DB for MCB SPN 8 way double door DB with 200 amps rated copper bus bar in SS enclosure having IP 43 and IK 09 protection including taking down old u/s DB and MCB's all as specified and directed . Note :- MCB SPN/SP shall be measured and paid under the respective item of the schedule.
S&F DB for MCB SPN 12 way double door DB with 200 amps rated copper bus bar in SS enclosure having IP 43 and IK 09 protection including taking down old u/s DB and MCB's all as specified and directed . Note :- MCB SPN/SP shall be measured and paid under the respective item of the schedule.
S&F sheet metal enclosure TPN MCB DB 8 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements Including taking down old u/s DB, MCB's all as specified and directed. Note :- (i) MCBs shall be measured and paid separately under the respective item of schedule.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp incl taking down old unservicable and connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC cool white (or) warm white colour, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling incl taking down old unservicable fitting and connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed.
M&L for GI Pipe 15mm light grade galvanised with all fittings laid in trenches all as specified and directed.
Schedule of credit amount brought back from Ser Page No.45- Rs. 1,18,815.00 will be deducted from the above quoted amount to derive the contract sum. SIGNATURE OF CONTRACTOR
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
technical_842421.pdf
techsummary_842421.pdf
finance_842421.pdf
BOQ Comparative Chart
xlsx
finsummary_842421.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
87740Generalpages.pdf
Tender Documents • 0.65 MB
BOQ_842421.xls
BOQ • 0.87 MB
87740PS.pdf
Additional Documents • 0.84 MB
Download all tender documents and submit your bid