Loading…
Loading…
Tender Value
₹7.6 Cr
EMD Value
₹15.3 L
Closing Date
23 Mar 2026, 5:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
MR Yognarayan sahu(DFLT)
CE(Baster)
RCPLWE Construction AND MAINTENANCE (BALANCE) WORKS OF MATWADA-JAIGUR-KUTRU ROAD LENGTH 18.00 KM INCLUDING 30 Nos CULVERT BLOCK BHAIRAMGARH DIST BIJAPUR (C.G.)
187077
NIT No. 1064/TC/EinC/ PWD/2025-26
OPEN TENDER
WORKS
6 days
CE(Baster)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
24 documents required · 24 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
OPEN TENDER
PERCENTAGE
OPEN TO ALL
CE(Baster)
PWD Bastar Circle, Jagdalpur
Paschhim Baster Div. Bijapur
90
06
No
0
187077
23 Mar, 2026 5:00:00 PM IST
27 Mar, 2026 10:00:00 AM IST
12 Mar, 2026 5:00:00 PM IST
NIT No. 1064/TC/EinC/ PWD/2025-26
RCPLWE Construction AND MAINTENANCE (BALANCE) WORKS OF MATWADA-JAIGUR-KUTRU ROAD LENGTH 18.00 KM INCLUDING 30 Nos CULVERT BLOCK BHAIRAMGARH DIST BIJAPUR (C.G.)
1527000.00 INR
Fixed Deposit Receipt (OFFLINE)
76339000.00
2
25 Mar, 2026 5:00:00 PM IST
76339000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
11d 3h 3m
24 documents required · 16 mandatory · 8 optional
₹0
₹15.3 L
12 Mar 2026
12 Mar 2026
27 Mar 2026
12 Mar 2026
23 Mar 2026
12 Mar 2026
25 Mar 2026
Compacting Original Ground / Existing Embankment Loosening, Levelling and Compacting original ground/existing embankment/supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.
Excavation in Cutting in Soil by Manual/Machinery means Excavation for roadway in soil for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of Embankment with Material Obtained from Pits Construction of embankment with approved material obtained from borrow pits, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 (Beyond 250m)with all leads as per Technical Specification Clause 301.5(Having CBR more than 5)
Construction of sub-grade and earthen shoulders with approved material (Granular material having CBR not less than 7) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.For Item No.3.12(a) & (b)
Granular Sub-base with Well Graded Material (CBR 20 or more) (Table 400.1) Crushed stone materials (CBR 35 or more) This item is to be used only, where local GSB material or GSB material with blending with other material is not available.
Water Bound Macadam with Crushable Screenings WBM Grading 2 Providing, laying, spreading and compacting mechanically crushed stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.
WBM Grading 3 Providing, laying, spreading and compacting mechanically crushed stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.
Construction of subgrade and earthen shoulders Construction of sub-grade and earthen shoulders with approved material (Granular material having CBR not less than 10) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.(To be used for side shoulder WBM)
Prime Coat (Low Porosity) Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
20mm thick Open-Graded Premix Carpet using Bituminous (VG/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of aggregate 13.2mm size (passing 22.4mm size sieve & retained on 11.2mm sieve and 11.2mm size (passing 13.2mm sieve and retained on 5.6mm sieve) either using penetration grade/ VG bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508., Viscocity grade (VG) Bitumen specification as per IS 73:2006
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510, Viscocity grade (VG) Bitumen specification as per IS 73:2006 Case - II : Type B (II) Bitumen (VG-30)
Semi-Reflective Traffic signs upto 0.90 sqm Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Semi-Reflective Traffic signs more than 0.90 sqm sign board Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Providing and fixing “Citizen Information Board/Maintenance Information Boade” of PMGSY Project (A) Providing and fixing of typical " PMGSY Citizen Information Board" with Logo as per MoRD specifications & drawings, made of 75 mm square or 75 mm dia circular steel tube of 12 SWG 3.2 m height and cross member 2 nos 1m long, fixed with angle iron 50x50x5 mm MS angle on the back
Kilometre Stones & Boundary Pillar Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 5th Kilometre Stone (precast)
Ordinary Kilometer Stone (Precast)
200 m stone (precast)
Boundary Pillar Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
Construction of Plain Cement Concrete Drain with P.C.C. grade M-15 including all shuttering/form work etc. complete as per drawings/technical specification and direction of engineer in charge.
Providing and laying reinforced cement concrete pipe NP3 for Culverts/ Burried conduits on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. (A) 600 mm dia
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C grade M 20 (i) For nominal mix 1:2:4
Excavation for Structure as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (A) Ordinary soil (i) up to 3 m depth
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 I. Stone/Boulder
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 (iii)Cement concrete grade M 10 in case of concrete block pitching
Dismantling Stone Masonry Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. (A) Rubble Stone Masonry in Lime/Cement/mud mortar
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. (A) Upto 600 mm dia
Filling in Foundation Trenches as per drawing and technical specification Clause 1108 & 305.3.9 I. Sand filling
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (ii) P.C.C grade M 15(Nominal mix (1:2.5:5)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 m I. P.C.C grade M 15 (Nominal mix (1:2.5:5)
P.C.C. grade M 20 (Nominal mix (1:2:4)
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. R.C.C M 25 (Design mix)
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
1st Year Maintenance
2nd Year Maintenance
3rd Year Maintenance
4th Year Maintenance
5th Year Maintenance
UOM Name
Percentage
Per mile
Siemens Per meter
Activity unit
Batch
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.08 MB
7680412232868641770_180035_Guidelines_.pdf
NIT • 0.13 MB
5640631325387174899_187077_RRP Recall NOTICE.docx
NIT • 0.05 MB
3396352394120028397_187077_SBD doc.doc
NIT • 0.57 MB
8200788032001223313_180035_boq.xlsx
BOQ • 0.03 MB
Download all tender documents and submit your bid