Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Provision of certain sanctioned works (02) in the area of AGE B/R II under GE (N) Ahmednagar
2021_MES_427596_1
8506 /E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹80,000
Yes
9 Apr 2021
3 Mar 2021
31 Mar 2021
3 Mar 2021
29 Mar 2021
17 Mar 2021
60 days
Amount
Excavating in trenches n exc 1.5 m deep and getting and getting out in any type of soil etc complete all as specified and directe by Engineer-in-Charge
All as per item No 1 (here-in-before) but exc 1.5m wide and n exc 3m in depth
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregates as in foundations filling and in mass concrete etc complete all as specified and directe by Engineer-in-Charge
M&L for RCC M-25 (using 20mm graded stone aggregates) in foundation, pillars etc complete all as specified and directe by Engineer-in-Charge
M&L formwork to sides of concrete foundations, footings, pillar bases of columns and similar work etc complete all as specified and directe by Engineer-in-Charge
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directe by Engineer-in-Charge
All as per item No 7 (here-in-before) but up to 8mm dia
M & L for preparation of new steel surface and applying two coats of synthetic enamel paint over and including one coat of primer etc complete all as specified and directed by Engineer-in-Charge
M&L for 300 mm bore RCC pipes class NP-2 laid and jointed with collars etc complete all as specified and directed by Engineer-in-Charge
All as per item No 9 (here-in-before) but 100 mm bore pipe
M&L for 150 mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge.
M&L for Concrete bed to drain pipes in PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid tested etc bore of pipe 300mm dia etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 12 (here-in-before) but 100 mm bore pipe
All as per item No 12 (here-in-before) but 150 mm bore pipe
All as per item No 12 (here-in-before) but 200 mm bore pipe
Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar etc complete all as specified and directed by Engineer-in-Charge
M&L for solid block masonry built with plain cement concrete (1:5:8) solid blocks, type C5, using 40 mm graded stone aggregates built in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
M&L for solid block masonry built with plain cement concrete (1:5:8) solid blocks, type-C5, not exc 10 cm built in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete of any description and in any position in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and directed by Engineer-in-Charge
M/L for providing 100 mm thick plain cement concrete (1:2:4) type B2 (40mm graded stone aggregate) as in flooring etc complete all as specified and directed by Engineer-in-Charge
M/L for providing 75mm thick plain cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base etc complete all as specified and directed by Engineer-in-Charge.
M & L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C1 using 20 mm graded stone aggregates as in coping including weathering, slightly rounded or chamfered angles and throating and necessary form work etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:3:6 type C1 using 20 mm graded aggregates in surface benching in manholes, channel and drain all as directed.
M&L for 10 mm thick rendering on brick / concrete surfaces in cement and sand mortar (1:4) surfaces finishined even and smooth with out using extra cement mixed with approved water proofing compound etc complete all as specified and directed by Engineer-in-Charge
Supply only Integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge
M&L for reinforced precast cement concrete cover slab, in RCC (1:2:4) type B1 using 20 mm graded stone aggregates including necessary form work for manhole covers etc. set in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge Note: Reinforcement shall be measured and paid separately.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass ( any thickness size ,quality or description ) from wooden/Steel frames glazed with putty or fixed with beads etc complete all as specified and directed by Engineer-in-Charge
M & L for 3 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in squares n.exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge
S & F in repairs galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks ,or galvanised wire staples including necessary beading etc complete all as specified and directed by Engineer-in-Charge
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge
M&L for coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of floor , as in floor etc laid over and including screed bed 15 mm thick in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
Dismantling of ceiling boards or insulation boards any thickness including cover fillets etc complete all as specified and directed by Engineer-in-Charge
M&L for Non-Asbestos Fiber Cement Building Board 4.0mm thick, fixed to GI Snap Grid on Ceiling, etc complete all as specified and directed by Engineer-in-Charge
Dismantling single layered Mangalore pattern or similar tiles as in roofing etc complete all as specified and directed by Engineer-in-Charge
M&L for roof tiles, Mangalore patterns , interlocking at side joints , laid dry etc complete all as specified and directed by Engineer-in-Charge
M & L for complete removal of existing treatment of wall and apply two coats of OBD over a layer of POP finish finished with roller finish including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frames exc. 1.5 sq. m and n exc 4.00 sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge
M&L for 35 mm thick plain framed, paneled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial plywood. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
S & F pressed steel door frame of size 100 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge
S&F butt hinges medium weight cold rolled mild steel 100mm long etc complete all as specified and directed by Engineer-in-Charge
S&F aluminium anodised barrel tower bolts of extruded section 100mm long etc complete all as specified and directed by Engineer-in-Charge
S&F aluminium anodised barrel tower bolts of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 300mm long.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat synthetic enamel paint over one coat of pink primer etc complete all as specified.
M & L for preparation of old steel surface and applying one coat of synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge
M & L for preparation of old plastered surface of wall and applying one coats of cement paint etc complete all as specified and directed by Engineer-in-Charge
S&F in repairs for false ceiling with Vinyl faced Arm-Gyp-FB, ceiling 600 x 600 x 9mm thick with washable metalized polyester foil backing with Vinyl covered edges, supporting sections shall be of suitable size from same makes embossed on sections and level adjuster duly suspended by 2 mm dia GI wire fixed to roof at 600mm centre to centre as per manufacturer's instructions / specification and all as directed including taking down/ out existing. Make : Armstrong or equivalent in Saint Gobian / Lafarge
S&F precast Hume Pipe septic tank of capacity 50 users including necessary excavation and earthwork in any type of strata etc complete all as specified and directed by Engineer-in-Charge
Taking down cement mortar plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 10 mm thick on stone/brick / concrete surfaces in cement and sand mortar (1:6) surfaces finished even and smooth without using extra etc complete all as specified and directed by Engineer-in-Charge
M & L for preparation of newly plastered surface of wall and applying two coats of OBD over and including 2mm thick Birla white putty finished with roller finish etc complete all as specified and directed by Engineer-in-Charge
M&L for coloured glazed ceramic tiles digitally printed premium designer series of size exc 0.12 Sqm and n'exc 0.18 Sqm , 7-8 mm thick as approved by GE as in dado / skirting or on vertical surfaces, over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile etc complete all as specified and directed.
Supplying and laying 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with all fittings including taking down etc complete all as specified and directed by Engineer-in-Charge
All as per item No 63 (here-in-before) but 20 mm dia
All as per item No 26 (here-in-before) but 25 mm dia
S&F in repairs bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule all as directed. Make:- Cat part No MOR 1020 A(Oriental series) of MARC or equivalent in makes mentioned in list of makes in Appendix `C'
S&F in repairs 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as directed. Make:- Cat part No MOR 1010(Oriental series) of MARC or equivalent in makes mentioned in list of of makes in Appendix `C'
S&F in repairs wash hand basin vitreous China white , flat back or angle type of size 500 X 400 mm incl pillar tap 15mm dia CP, waste chain and plug and porcelain stopper , waste pipe, a pair of brackets, or erecting stand and PVC connection etc complete all as specified and directed by Engineer-in-Charge Make :- Cat Part No C0471 (CHT) Indus series of Parryware or equivalent in makes mentioned in list of makes in Appendix `C'
M&L for steel ventilator with top hung shutter including hinges, steel peg stay, etc complete all as specified and directed by Engineer-in-Charge
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge
M&L for hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge
M&L for 75 mm thcik PCC type C- 2, (1:3:6) (using 40mm graded stone aggregate) as in plinth protection etc complete all as specified and directed by Engineer-in-Charge
Material and labour for coloured glazed ceramic tiles size exc 0.12 Sqm and n'exc 0.18 Sqm , 8-10 mm thick as in dado over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge.
S&F factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face , supplying & fixing in frame at site as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge.
S&F of solid PVC door frame 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face etc complete all as specified and directed by Engineer-in-Charge.
S&F vitreous China bowl urinal flat back, size of 270X360X450 mm, white, with grating and union for discharge pipe excluding flushing cistern, flush pipe and waste pipe, complete including providing and fixing plugs, bedding urinal against wall in cement and sand mortar (1:2), securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement and sand mortar (1:4) complete all as specified and as directed.
Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren etc complete all as specified and directed by Engineer-in-Charge. Make :- Cat Part No C0117 Of Parryware or Cat Part No 20042 of Hindware or equivalent in makes mentioned in list of makes in Appendix `C'
M & L for 15 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc complete all as specified and directed by Engineer-In-Charge.
M & L for 20 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc incl taking down old, etc complete all as specified and directed by Engineer-In-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-In-Charge.
Supply and fix in repair stop valve, 15 mm dia, cast copper alloy,screwed down high pressure screwed down high pressure with cruitch or butterfly handle screwed both ends for iron pipe or for unions all as directed. Make:- Cat part No MOR 1320 (Orintal series) of MARC or equivalent in in makes mentioned in list of makes in Appendix `C'
M&L cast iron floor/Nahani trap with grating 75mm dia including jointing to waste pipe fixed in cement concrete type (1:2:4) type B1 including removing old traps etc complete all as specified and directed by Engineer-in-Charge
S&F 40 mm bore low density polyet- hylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engineer-in-Charge
S&F of 75 mm bore PVC (SWR) bends with access door etc complete all as specified and directed by Engineer-in-Charge
S&F of 110 mm bore PVC (SWR) bends with access door etc complete all as specified and directed by Engineer-in-Charge
M&L for constuction of RCC Hume pipe septic tanks designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc. complete for 10 users as per Drg all as specified and as directed by Engr-in-Charge.
M&L for pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, coloure and design as approved by GE
S&F of Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 etc complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil etc complete all as specified and directed by Engineer-in-Charge
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Excavation in post holes (or similar) each n exc 0.5 cum ,getting out, returning, filling in and ramming earth watering and removing surplus soil to distance n'exc 50 m and making good surface in soft loose soil etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new plastered surfaces and applying two coats of cement paint over one coat of white wash etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C2 using 40 mm graded aggregate in fencing post, etc.
S&F mild steel angle for fencing post including cutting in shape required, mild steel flat iron etc complete all as specified and directed by Engineer-in-Charge.
S&F mild steel bolts with nut and washer for fixing of chain link fencing etc complete all as specified and directed by Engineer-in-Charge.
S&F mild steel round bars for staining and fixing of chain link fencing etc complete all as specified and directed by Engineer-in-Charge.
Supply only chain link fencing etc complete all as specified and directed by Engineer-in-Charge.
Fixing only chain link fencing etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories and provision of PVC boxes (upto 12 module suitble for Mylinc series of Legrand including white plates with frame upto 12 module of make suitable for Mylinc Series ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. (Make of Cable : Finolex/RR Cable/Havells & Make for Conduit : AKG/PRESTOPLAST/PRECISION): - Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Wiring shall be done as per complaints recd from user only on required basis it is not necessary to do whole wiring of any whole bldg 3. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc
One light point controlled by one switch
One fan point controlled by one switch
One 3 pin 5 Amps socket outlet on same board controlled by one switch
One 3 pin 5 Amps socket outlet on independent board controlled by one e switch
All as per Item No 94 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket outlet on independent board
S&F switch piano Modular type single pole, one way 5/6 Amps etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket 2 in 1, 5/6 Amp 230V AC etc complete all as specified and directed by Engineer-in-Charge.
S&F switch piano Modular type single pole, one way 16 Amps etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket 2 in 1, 16 Amp 230V AC etc complete all as specified and directed by Engineer-in-Charge.
S & F stepped type electronic fan regulator Modular type on the existing phenolic laminated sheet etc. as reqd etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge.
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body all as speccified and directed
S&F in replacement double door Sheet metal enclosures factory made DBs 4 way, (TPN DB's) including all MCCBs 63 Amps,415 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge. Make: Legrand Cat No 5076 or equivalent makes in list of makes in Appendix `C'
S&F in replacement double door Sheet metal enclosures factory made DBs 8 way, (SPN DB's) 240 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement double door Sheet metal enclosures factory made DBs 4 way, (SPN DB's) 240 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB , SP, AC, 240 volts of 06 to 40 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCBs, SPN, AC, 240 volts of 63 Amps, 16 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
S&F Smart bright Extruded Aluminium LED batten, 21 watt, 2500 lumens, 6500 K, 230 volts (4ft run length) suitable for surface, wall, & conduit mounting complete including all accessories, three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length for connection etc complete all as specified and directed by Engineer-in-Charge. Make:- Philiphs CAT Part No BN 021 LED 25S 6500 PSU GR S1 or equivalent makes mentioned in list of makes in Appendix `C'
S & F Lumeno LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder and wall light etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge. Make -Havell's Cat Part: (ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC) or equivalent in make of Philips/ wipro
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through in and incl PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly all as specified & directed. (Make of Cable : Finolex/RR Cable/Havells & Make for PVC Casing & Caping : AKG / PRESTOPLAST / PRECISION): - Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) Note: Two run of 4 sq.mm cable, one run of 4 sq.mm cable and one run of PVC Casing & caping shall be measured as one unit
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing House service bracket (hook type complete with 3.0m long G. I. pipe 40mm dia Med. Grade, two nos 90⁰ bends. M.S. hook and stay guy etc complete all as specified and directed by Engineer-in-Charge.
Taking out/down and opening of existing ceiling fans 1200/1400 mm sweep,from any position, of any make etc & refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material /items , making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional. removing burnt out defective unserviceable winding & rewinding with approopriate size of super enamelled copper wire including applying super enamelled varnishing over winding , drying etc , reassembling and fixing after repair replacement Ball bearing No 6201 & 6202, and replacement of capacitor 2.5 mfd, 250 volts , AC, replacement of rubber reel, bolt, nut including pin etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25mtr depth and top edge of the earth plate not less than 1.5mtr below normal ground level connected to galvanised earth lead wire 4.0Sqmm dia by means of nuts,bolts & washer etc. Earth wire connected upto main earth point/DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 ( using 20 mm graded stone agregate) and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of ms bar @ 15 mm CIC with both way lifting arrangement complete including all necessary excavation & earth work etc complete all as specified and directed by Engineer-in-Charge.
Taking out/down carefully and opening of existing water Geysers of 25 Ltrs capacity,from any position, of any make etc & refixing after reassembling and after repair /replacement of spare parts/ material/items, at the desired location and making necessary water inlet, outlet & electric connections to make in functional by using material/parts of minor nature such as screws, insulation tape, nuts, bolts, washers etc including cleaning and painting with spray painting to required gloss with white synthetic enamel paint to complete body & writing MES No with black paint etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement element 1.5 KW, rubber gasket type with & including rubber gasket complete suitable for 25 Ltrs Geysers of any Make as installed at site etc complete all as specified and directed by Engineer-in-Charge
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver etc complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core etc complete all as specified and directed by Engineer-in-Charge.
Cutting to existing CI/GI pipe line upto 80 /50/25 mm dia for taking connection up to 25 mm dia GI pipe including insertion of CI /GITee complete all as specified and directed including Exc & earth Work
Supply and lay in trenches/or on wall medium grade steel water tubing galvanised with all fittings and joints etc complete all as specified and directed by Engineer-in-Charge. for following size :-
(b) 20 mm bore
S&F Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for for 20 mm bore etc complete all as specified and directed by Engineer-in-Charge.
Supply & Lay HDPE pipe 65 mm bore for laying of LT cable complete with all accessores specified and directed
M&L point wiring complete with 1.5sqmm single core unsheathed PVC insulated FRLS cable 1100 V grade multistranded copper conductor of different code of ISI marked drawn through and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly including provision of PVC box of suitable size for mounting switches / sockets and fan regulators etc complete all as specified and directed for the following:-
(a) One light point controlled by one switch one way
(b) One ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way
(c) One switch socket outlet three pin 5 /6 Amps controlled by one switch on independent board.
M&L switch piano flush type single pole,one way, 5 Amps, 240 V etc complete all as specified and directed by Engineer-in-Charge.
S&F lamp holder,PVC/Polycarbonate type with back plate suitable for batten fittings etc complete all as specified and directed by Engineer-in-Charge.
M&L sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in PVC Casing caping 20mm complete all as sfecified and directed (a) 2 run of 4sqmm PVC FRLS copper cable and 1run of 2.5 sqmmPVC FRLS copper cable for earth wire Note for sub main wiring :- 2 runs of wire and 1 run of earth wire will be measured as one unit i.e RM 2. Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted rate.wiring 2 run of wire and1 run of earth wire .
S&F sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 4 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces.
S&F MCB SPN 10 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series. etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB , SP, AC, 240 volts of 06 to 40 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with complete with all accessories all as specified & directed Make ; Havells E-LITE LED PRIDE PLUS NEO Cat No LHEXACP71N1W020) or its equivalent makes mentioned in list of makes in appendix `C'
An amount of Rs 82,709.00 shall be deducted from BOQ on account of schedule of credit
M/s.Abhay Kulkarni and Associates
Arihant Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .