Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹1.6 L+₹23,600 (17.1%)Admitted-Fee/PreQual/Technical/Finance NO 64 4 STATE BANK COLONY EDAMALAI PATTIPUDUR TRICHY 620012 | TRICHY | TRICHY | TAMIL NADU | 620012 | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | V BEST ENGINEERS L1 | RCS L2 |
|---|---|---|---|---|---|
| 1.00 | Renewal by Supply, Erection, testing and Commissioning of 1.5.0 TR (45000K cal / hr) ABS plastic split type Air conditioner confirming to IS 1391 [part 2] 1992 with Rotary compressor operating on refrigerant R-22/Non CFL suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with Three Star rating as per BEE Specification Three Star Rated and capable of performing the following functions.
(A) Cooling (B) Dehumidifying (C) Air Circulating. (D) Filtering.The installation work for the above split type AC units includes the following.
1. Mounting / fixing indoor and outdoor units at their respective locations.
2. Laying refrigerent pipe line of 6mtrs. distance, both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm.
3. Installing the suction pipe with expanded polythene foam 5mm thick tubing.
4. Laying 15mm dia flexible PVC drain pipe of 6mts. Length to throw out the condensate water being formed in the indoor unit.
5. Leakage testing the entire gas unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units up to 4mtr. length and up to switch within the 3 mtrs. of location of indoor unit. (Make - Carrier / Voltas / Blue Star make only) | 2 | No. | 35,000 ₹70,000 Lowest | 45,000 ₹90,000 |
| 2.00 | Renewal by Supply and Erection of 4 KVA electronic automatic Voltage stabilzer with input range of 170V-270V and output range of 200-240V with high / low cut off 3 minutes time delay relay with demonstration suitable for operation on 230V/50HZ single phase AC supply.(V-GUARD/syscom/equ). | 2 | No. | 4,000 ₹8,000 Lowest | 4,000 ₹8,000 Lowest |
| 3.00 | Supply and fixing of MS stand for fixing outdoor unit. | 2 | No. | 950 ₹1,900 Lowest | 950 ₹1,900 Lowest |
| 4.00 | Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug on wall with earth connection (For AC Plug) | 2 | No. | 1,190 ₹2,380 Lowest | 1,190 ₹2,380 Lowest |
| 5.00 | Renewal by supply and fixing of 1meter downrod in existing Ceiling fans. | 47 | No. | 462 ₹21,714 Lowest | 462 ₹21,714 Lowest |
| 6.00 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and with painting of suitable colour. | 51 | Mtr. | 260 ₹13,260 Lowest | 260 ₹13,260 Lowest |
| 7.00 | Less credit | 1 | Lot | 600 ₹-600 Lowest | 600 ₹-600 Lowest |
| 8.00 | GST @ 18% | 1 | Job | 20,997.72 ₹20,997.72 Lowest | 24,597.72 ₹24,597.72 |
Tender Value
₹1.4 L
EMD Value
₹1,400
Closing Date
19 Nov 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical), PWD, Trichy
Office of the Executive Engineer(Electrical), PWD, Electrical Division, Trichy
Provision of Additional Air conditioner units in Blood Bank and Additional Fan Down rod and allied works at various places in the Government Medical College Hospital at Ariyalur in Ariyalur District.
2026_PWD_721859_1
TN No 5 2026-27 Dt 03.11.2026
Open Tender
Electrical Works
Item Rate
Ariyalur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1,400
20 Nov 2026
5 Nov 2026
20 Nov 2026
5 Nov 2026
19 Nov 2026
5 Nov 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Renewal by Supply, Erection, testing and Commissioning of 1.5.0 TR (45000K cal / hr) ABS plastic split type Air conditioner confirming to IS 1391 [part 2] 1992 with Rotary compressor operating on refrigerant R-22/Non CFL suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with Three Star rating as per BEE Specification Three Star Rated and capable of performing the following functions.
(A) Cooling (B) Dehumidifying (C) Air Circulating. (D) Filtering.The installation work for the above split type AC units includes the following.
1. Mounting / fixing indoor and outdoor units at their respective locations.
2. Laying refrigerent pipe line of 6mtrs. distance, both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm.
3. Installing the suction pipe with expanded polythene foam 5mm thick tubing.
4. Laying 15mm dia flexible PVC drain pipe of 6mts. Length to throw out the condensate water being formed in the indoor unit.
5. Leakage testing the entire gas unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units up to 4mtr. length and up to switch within the 3 mtrs. of location of indoor unit. (Make - Carrier / Voltas / Blue Star make only) | 2 | No. | - | - |
| 2 | Renewal by Supply and Erection of 4 KVA electronic automatic Voltage stabilzer with input range of 170V-270V and output range of 200-240V with high / low cut off 3 minutes time delay relay with demonstration suitable for operation on 230V/50HZ single phase AC supply.(V-GUARD/syscom/equ). | 2 | No. | - | - |
| 3 | Supply and fixing of MS stand for fixing outdoor unit. | 2 | No. | - | - |
| 4 | Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug on wall with earth connection (For AC Plug) | 2 | No. | - | - |
| 5 | Renewal by supply and fixing of 1meter downrod in existing Ceiling fans. | 47 | No. | - | - |
| 6 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and with painting of suitable colour. | 51 | Mtr. | - | - |
| 7 | Less credit | 1 | Lot | - | - |
| 8 | GST @ 18% | 1 | Job | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
129bloodbank.pdf
Tender Documents • 0.71 MB
BOQ_866826.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .