Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC E 82 HQ CE A N Z PB POST BOX NO 687 LILLYPUR NEAR MES GURUDWARA HADDO POST SRI VIJAYA PURAM 744 102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.5 L+₹1.8 L (4.60%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹43.3 L+₹3.6 L (9.08%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
CERTAIN B/R AND E/M REPAIRS AND PERIODICAL SERVICES AT MC DET, PHOENIXBAY, NAD, SAMUDRIKA AND MES BUILDING AND OTHER MINOR UNITS, JCDA OFFICE, HOSTEL, DAD GUEST HOUSE AND NAVY PARK UNDER AGE B/R-I OF GE HADDO, PORT BLAIR
2023_MES_603944_1
8770/GE/H/PB
Open Tender
Civil Works
Item Rate
270 days
GE Haddo Port Blair
Class D category a(i)
9 documents required · 9 mandatory
₹500
Yes
GE Haddo
₹90,000
Yes
8 Sept 2023
17 Jun 2023
22 Jul 2023
17 Jun 2023
18 Jul 2023
1 Jul 2023
17 Jun 2023 - 27 Jun 2023
Amount
Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry not exceeding 10cm in width and setting in cement mortar (1:4) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
Supply only integral water proofing compound.
M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whiting on plastered surface complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of external walls of any description and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer complete all as specified and as directed.
Dismantling floor/ skirting (Terrazzo/ PCC/Ceramic tiles) including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for glazed ceramic tiles in vertical surfaces using size of tiles 350x250x7mm / 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tile with and including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) of approved shade, area of each tile not exceeding 0.36 Sqm as in floors etc., laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
M&L for 15mm dia or bore galvanised steel tubing, medium grade, with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F 20mm bore CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and as directed.
Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
M&L for 20mm dia or bore galvanised steel tubing, medium grade, with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F 25mm bore CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings , fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
S&F in repairs flush pipe of polyethylene of low or high density or PVC, 32mm dia for flushing cistern all as specified and as directed
S&F in repairs white vitreous china wash down water closet pan (pedestal pattern) with PVC seat cover with mild steel chromium plated or aluminised hinging device including connection to down pipe and flushing pipe all as specified & directed.
S&F in repairs wash hand basin vitreous china white (flat back) of size 550x400mm including 15 mm dia pillar cock , CI bracket 15mm dia polythene connection , 32mm dia waste coupling and 32mm dia PVC waste pipe 900mm long etc. complete all as specified, including taking down the existing wash hand basin all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified and as directed.
S&F in repairs 32mm dia waste coupling fitting, brass, chromium plated for basin, with long screw sanks and fly nut, bedded in red lead cement.complete all as specified and directed.
S&F in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover with stainless steel/ PVC/ Aluminium hinging die as required and as specified
S&F in repairs bib tap 15mm dia or bore, cast copper alloy, chromium plated with capstan headed handle screwed down, for iron pipe complete all as specified and as directed.
S&F in repairs pillar tap, brass, 15mm dia, chromium plated, fancy type with capstan heads, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed. MAKE: PRAYAG Cat part No. PIS-02H or equivalent in PARRYWARE/JAQUAR/JOHNSON
S&F in repairs angular stop cock, 15mm dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, with long shank and cup (concealed type) screwed down, screwed both ends for iron pipe or for unions complete all as specified and as directed. MAKE: Jaquar Cat part No. CON-053KN or equivalent in PARRYWARE/ PRAYAG/ JOHNSON
S&F in repairs WHB mixer, 15mm dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, with long shank with central hole screwed down, screwed both ends for iron pipe or for unions, complete all as specified and as directed. MAKE: JAQUAR Cat part No. CON-167KNB or equivalent in PARRYWARE/ PRAYAG/ JOHNSON
S&F wall mixer, 15mm dia, cast copper alloy, chromiun plated, three way HOT & COLD, heavy duty, fancy type, screwed down for iron pipe or for unions, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. CON-281KN or equivalent in PRAYAG/PARRYWARE
S&F in repairs bib tap, brass, 15mm dia, chromium plated, fancy type long body, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed. MAKE: Jaquar Cat part No. CON-107KN or equivalent in PARRYWARE/ PRAYAG/ JOHNSON
S&F in repairs toilet paper holder, brass, chromium plated complete all as specified and as directed. MAKE: JAQUAR Cat part No. ACN-1153N or equivalent in PARRYWARE/ PRAYAG/ JOHNSON
S&F in repairs tubular towel rail, brass, chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. AQN-7711 or equivalent in PARRYWARE/ PRAYAG/ JOHNSON
S&F in repairs health faucet, brass, chromium plated with 8mm dia, 1.0 m long flexible tube, screwed for iron pipe or for brass ferrule 15mm dia or bore complete all as specified and as directed. MAKE: PRAYAG Cat part No. BEA-41 or equivalent in PARRYWARE/ ZOLOTO/ JOHNSON
Supply and fix Vitreous China urinals, Half stall type, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) and including PTMT urinal spreader, PTMT domed 32mm bore dia waste coupling and waste pipe complete, fixed in repairs all as directed.
S&F in repairs stainless steel grating cover 100mm dia fixed with white cement complete all as specified and as directed
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc., complete all as specified and as directed.
Demolition stone slabs and tiles of any description or thickness in floors, aprons, risers of steps, skirting, dado etc., laid bedded and pointed in any mortar complete all as specified and as directed.
S&F pre-painted zinc coated aluminium sheet (Galvalume) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F pre-painted zinc coated aluminium sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scaffolding for a height upto 12.0 metres complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
M&L for mild steel hold fasts, bands, straps, supports or stays for rainwater, brackets/clamps for eaves/barge boards and valley gutter and similar articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F aluminium flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers.
M&L for 18 to 20mm thick granite slab (of approved shade), machine cut, as in floors, vertical surfaces, steps (treads/risers) and the like laid over 15mm thick screed bed in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, polishing and rounding (chamfering) the edges complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 50mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in levelling course, sub base of floorings and pavings complete all as specified and as directed.
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for complete removal of old decorated surafces of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
M&L for preparation of old brick/ concrete surfaces of walls and cornices by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots etc and applying of one coat 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 0.75 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
M&L for complete removal of old decorated surfaces of walls and cornices and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for preparation of old decorated surfaces of walls and cornices by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots etc and applying one coat of distemper oil emulsion complete all as specified and as directed.
M&L for preparation of old surfaces of ceilings and cornices by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforescent salt and trading oil and greasy spots etc and applying one coat of distemper oil emulsion complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint of first quality complete all as specified and as directed.
M&L for preparation of old steel surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint of first quality complete all as specified and as directed.
M&L for preparation of old painted surfaces of walls/concrete, kerb stone etc of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
S&F in repairs three layered rotational moulded polyethylene water storage tanks, triple layered, ISI marked (cylindrical vertical with closed top), 500 litres capacity, hoisted and fixed in position all as specified in SSR Part I, 2009 including provision of 40mm/25mm spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
S&F in repairs three layered rotational moulded polyethylene water storage tanks, triple layered, ISI marked (cylindrical vertical with closed top),1000 litres capacity, hoisted and fixed in position all as specified in SSR Part I, 2009 including provision of 40mm/25mm spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
Dismantling ceiling boards / wall cladding (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets and grid complete all as specified and as directed.
M & L for prelaminated particle board 18-19mm thick (ISI Make), interior grade prelaminated one side with decorative choice laminations and other side balancing white lamination, fixed with screws to timber, steel frame work as in shelves or shutters, panelling etc,fixed in repairs, complete all as specified and directed.
M&L for providing 18mm thick superior chemical pressure treated edge glued finger jointed rubco hut rubber wood and the 8" width panel of board will be fixing after cutting of 12.7mm tongued and grooved will be fixed over rubber wood frame/ rubber wood runner (beam) of sizxe 5mm x 18mm fixed by secret nailing on the panel & the frame will be fixing on the wall by metal screws, before fixing the rubberwood panels on the frame all the surface area applying SH adhesive (Make Fevicol) for enhanced fion the wall. There will be fixing designed rubwood beading on top and bottom termination of wood boarding and finished after completing the carpentary works all the visible wood area will be sanding by No. 60 & 80 wood sanding paper, after that will be applying Sheenlac make filler with mixing of NCD thinner (Sheenlac make), the pasting chock putty in the shabby / nailing area which will be sanding with No. 120 sanding paper, after that will applying sealer of sheenlac make and walnut colour stainer, then cutting with No. 320 sand paper, after completing the above process will spray melamine polish of Berger / Sheenlac make then cutting with No. 400 sanding paper and finally applying Silicon (Make Waxpol) with Soft Banyan Cloth for better shining / finishing. complete all as specified & directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed.
S&F for roof trusses (framed), trussed, purlines, and fastening and heavy brackets framing (beam, tee, angle, channel or flats section) including distance pieces, cleat etc conforming to Fe-410 (Gde-E250) quality -A complete all as specified and directed.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., 4mm thick non-asbestos fibre cement building design boards duly applied with two coats of oil bound distemper over a coat of primer fixed or laid/ inserted to aluminium frame work with screws complete all as specified and as directed.
M&L for seamless gypsum board false ceiling 12 mm thick including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with joining compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flange of 20mm and 30 mm, web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed.
Taking down shutters of any description, area not exceeding 1.0 Sqm each and removing to store complete all as specified and as directed.
Taking down shutters of any description, area exceeding 1.0 Sqm but not exceeding 2.0 Sqm each and removing to store complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each and removing to store complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area not exceeding 1.5 Sqm each complete all as specified and as directed.
S&F Second class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints including preservative treatment complete all as specified and as directed.
S&F 35mm thick second class hard wood, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, fixed to chowkats complete all as specified and as directed.
S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), fixed to chowkats complete all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube as per specification & drawing, fixed in opening complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rail and bottom rail, pannelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement S&F in the frames at site as per specification and drawings complete all as specified and as directed.
M&L for aluminium partition, window and door/ventilator with frame and shutters fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
Supply only stainless steel IMAX Hinges for aluminium window shutter
Supply only aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed.
Supply only for 4.0 mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading) in square not exceeding 0.5 Sqm in each panes complete all as specified and directed..
Supply only for 4.0 mm thick figured glass, pin head type and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only 12mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side with balancing white lamination complete all as specified and as directed.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F 150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F in repairs 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21 complete all as specified and as directed.
S&F sliding door bolt, 300mm long, aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
S&F sliding door bolt, 250mm long, aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and as directed.
S&F in repairs 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F in repairs 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21 complete all as specified and as directed.
S&F in repairs 150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F in repairs sliding door bolt, 300mm long, aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
S&F in repairs floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm complete all as specified and as directed.
Supply and fix in repairs aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of pink primer complete all as specified and as directed.
S&F in repairs curtain rails, 20mm dia, anodised aluminium decorative type powder coated including designed fixing brackets, complete all as specified and as directed.
S&F door closer, aluminium (extruded section body), hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, fixed in repairs with screws complete all as specified and as directed.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints,fixed to walls using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 110mm complete all as specified and as directed.
S&F in repairs 75mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, fixed to walls using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 75mm complete all as specified and as directed.
Taking down carefully old unserviceable aluminium/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.
Taking down existing unserviceable main switches/ distribution boards of any description along with MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed.
Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for the following :- Make or wire : Polycab / Gloster / Anchor / Finolex Make of PVC Casing & Caping : Modi /Precision / Supreme / Finolex / Polycab
ONE LIGHT/FAN point controlled by one, one way 5 Amps switch.
ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on independent board.
ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on same board.
ONE BELL point controlled by one, one way 5 Amps switch.
ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on independent but below the switch board of light point with cable of 1.5Sqmm size.
M&L for Point wiring complete with 4 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 4 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 15A SOCKET OUTLET point controlled by one, one way 15 Amps switch on independent board.
S&F switch piano, flush type, single pole, one way, 5 Amps, 240 volts complete all as specified and as directed. Make: Anchor/Cona/Legrand
S&F switch piano, flush type, single pole, one way, 15 Amps, 240 volts complete all as specified and as directed. Make: Anchor/Cona/Legrand
S&F socket outlet, 2-in-1 pin, 5A, flush type, multipurpose, 240 volts complete all as specified and as directed. Make: Anchor/Cona/Legrand
S&F socket outlet, 2-in-1, 5 pin, 15A, flush type, multipurpose, 240 volts complete all as specified and as directed. Make: Anchor/Cona/Legrand
Repair to LED light / PTLS of any model / make / rating in position including testing of serviceability of connected accessories and wiring upto respective switch / control unit including and replacing unserviceable items such as drivers, holder and making light complete all as specified and directed.
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 5A, 240 volts complete all as specified and as directed.
S&F electric bell, ding dong type, AC, 230 volts complete all as specified and as directed. Make: Anchor/Cona/Legrand
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 25mm dia) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for the following:- Make or wire : Polycab / Gloster / Anchor / Finolex Make of PVC Casing & Caping : Modi /Precision / Supreme / Finolex / Polycab
ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch.
TWO LIGHT points controlled by one, one way 6 Amps modular switch.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on independent board.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on same board
ONE BELL point controlled by one, one way 6 Amps modular switch.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent but below the switch board of light point with cable of 1.5Sqmm size.
M&L for Point wiring complete with 4 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 25mm dia) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 4 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board.
M&L for repair to point wiring for light / fan / socket by cutting, removing and replacing the burnt and unserviceable wire with new FRLS cable and conduits with copper conductor 1.5 / 2.5 Sqmm size, jointing with same size wires, replacing the saddles, refixing the loose / hanging conduits / casing capping properly all as directed. NOTE : (i) Rate is inclusive for FRLS cable and other minor items. (ii) The representative of the Contractor shall report to Engineer-in-Charge / JE on daily basis to carry out repairs and completion report to be submitted all as specified and directed.
S&F in repairs the following items including disconnecting, removing the unserviceable item and connecting into electric circuit and testing.
(a) S&F switch socket combination box type 2-in-1, 5 pin, 5 Amps, flush type, universal all as specified and as directed. Make : Anchor / Cona / Legrand
(b) S&F switch socket combination box type 2-in-1, 6 pin, 15 Amps, flush type, universal all as specified and as directed. Make : Anchor / Cona / Legrand
(c) S&F modular electronic fan regulator for ceiling fan, step type, 5 speed, AC, 2 module, 120 watts, 240 volts complete all as specified and as directed. MAKE : Anchor/ Cona / Legrand.
S&F modular switch, one way, one module, single pole, 6 Amps, 240 Volts AC complete all as specified and as directed. MAKE : ROMA (Anchor)/ Havells (Crabtree) / Legrand.
S&F modular switch, one way, one module, single pole, 16 Amps, 240 Volts AC complete all as specified and as directed. MAKE : ROMA (Anchor)/ Havells (Crabtree) / Legrand.
S&F modular socket outlet, multipurpose, 2/3 pin combined, 2 module, single pole, 6 Amps, 240 Volts AC complete all as specified and as directed. MAKE : ROMA (Anchor)/ Havells (Crabtree) / Legrand.
S&F modular socket, outlet multipurpose, 2/3 pin, 6/16 Amps combined, 2 module, single pole, 240 Volts AC complete all as specified and as directed. MAKE : ROMA (Anchor)/ Havells (Crabtree) / Legrand.
S&F modular bell push, one way, one module, single pole, 6 Amps, 240 Volts AC complete all as specified and as directed. MAKE : ROMA (Anchor)/ Havells (Crabtree) / Legrand.
Taking down carefully ceiling fan of any make, size from its location, dismantling complete, examine complete parts throughly, oiling, greasing all parts and complete overhauling of fan including replacement of small parts such as split oin, nut bolts, screws and assembling back the fan, make fully functional, re-fixing the fan to its position including replacing and providing of twin core copper wire 23/0.0076 from fan to ceiling rose and painting the fan with same colour of fan complete all as directed.
All as per item No.124 above but exhaust fan any make, size and type including painting to existing colour of fan all as directed.
All as per item No.124 above but wall mounting fan any make, size and type including painting to existing colour of fan all as directed. Note : Item No. 124 to 126 : The representative of the Contractor shall report to Engineer-in-Charge / JE on daily basis to carry out repairs to fan and completion report to be submitted.
Rewinding of ceiling fan (any sweep) stator by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in ceiling fan complete all as specified and as directed.
Rewinding of exhaust fan by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in exhaust fan complete all as specified and as directed.
Rewinding of wall mounted fan by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position wall mounted fan complete all as specified and as directed.
S&F sealed ball bearing suitable for ceiling fan with bearing No. 6201/6202 complete all as specified and as directed.
S&F shaft suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and as directed.
S&F in repairs of fan blades for ceiling 1200mm/1400mm sweep indicating all accessories complete all as specified and directed.
S&F in repairs wall mounted fan blade set of 300/400mm sweep including all accessories complete all as specified and as directed.
S&F exhaust fan blade set of 150/250/300/380mm sweep body metal or plastic including all accessories complete all as specified and as directed.
Taking down carefully electric geysers of any make, type and capacity after disconnecting of electrical and water connections, opening of bottom cover, checking of all parts and taking out copper tank, checking of its leakage and removing the dust, brazing the leakage and painting of geysers with two coats of synthetic enamel paint, replacement of burnt out spares and assembling the geyser and re-fixing back in its original position complete all as specified and as directed. NOTE: Spares shall be measured and paid separately under relevant items as SUPPLY ONLY.
SUPPLY ONLY heating element 1500 watts.
SUPPLY ONLY thermostat switch.
SUPPLY ONLY pressure release valve.
SUPPLY ONLY thermal cut out.
SUPPLY ONLY indicator lamp RED/GREEN colour.
SUPPLY ONLY connecting pipe
S&F Starter switch of capacity 25 Amps, including 4 modular plate, one 16A socket and one 16Amps plug top, working on 240 volts AC supply, suitable for air conditioner. MAKE: Crabtree / ANCHOR (ROMA)/ HAVELLS/LEGRANT
M&L for Sub main wiring complete with four runs of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Four runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with four runs of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 10 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Four runs of 10.0 Sqm copper conductor, One run of 10.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including not less than 25mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 1.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including not less than 25mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 1.5 Sqm copper conductor, One run of 1.5 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S & F DB VTPN sheet metal enclosure double door IP 43 protection, door earth suitable for incoming upto MCCB 160 Amps/200 Amps & outgoing MCB TP / SP. Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete including taking down old unserv DB of any type /rating and making good to the distrubed surface /walls all as specified and directed. Make : Indo Asian/Havells/L&T/Legrad
S&F MCB DB, SPN, 12-way, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and incl taking down old u/s DB of any type/rating and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811808 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F MCB DB, SPN, 8-way, double door, 240 Volts with 100 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and incl taking down old u/s DB of any type/rating making good disturbed surfaces to match with surrounding surface complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811807 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F MCB DB, SPN, 4-way, double door, 240 Volts, 50 Hz with 100 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and incl taking down old u/s DB of any type/rating making good disturbed surfaces to match with surrounding surface complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811805 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F in repair MCCB, 4 pole, 125 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed. MAKE: INDO ASIAN/ L&T/ LEGRAND/ HAVELLS
S&F in repairs MCCB, 3 pole, 100 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed. MAKE: INDO ASIAN/ L&T/ LEGRAND/ HAVELLS
S&F MCB, TPN, "C" series, 415 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811220 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, TP, "C" series, 230 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811198 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, TP, "C" series, 230 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811196 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, DP, "C" series, 230 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811174 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811122 to 811129 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F in repair of 18 watts surface mounted LED light fitting with slim high perfomanance surfaced mounted LED Panel. PDC, aluminium housing and and high translucent frosted plastic diffu7ser makes it a robust luminaire , efficacy . 100 lm/W light fittings yellow/white colour, round/square shape as requirtaed at site complete all as specified and directed. Make : CG Cat Part No: LCDSPLN-S-18-CDL or equivalent make of Philips/Havells/Luker NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S&F 18 Watts, 220 Volts recess mounting LED ceiling light fitting, yellow/white colour, round/square shape as requirement at site, made from slim design LED polycarbonate ;housing down lighter with superior light output and integral driver. Efficiencxt 100 lm/w complete all as specified and directed. Make : CG Cat Part No. LCDEP-18-CDL or equivalent make of Havells/Luker/Philips NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S&F 15 Watts, 220 Volts recess mounting LED ceiling light fitting, yellow/white colour, round/square shape as requirement at site, made from slim design LED polycarbonate ;housing down lighter with superior light output and integral driver. Efficiencxt 100 lm/w complete all as specified and directed. Make : CG Cat Part No. LCDEP-15-CDL or equivalent make of Havells/Luker/Philips NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S&F 09 Watts, 220 Volts recess mounting LED ceiling light fitting, yellow/white colour, round/square shape as requirement at site, made from slim design LED polycarbonate ;housing down lighter with superior light output and integral driver. Efficiencxt 100 lm/w complete all as specified and directed. Make : CG Cat Part No. LCDEP-09-CDL or equivalent make of Havells/Luker/Philips NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S&F 30 Watts LED light, recess mounting luminaire with glare free uniform illumination having longer life and less maintenance, size 600mmx600mm, 25000 burning hours including all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat Part LCTLRNE-30-FO- CDL or equivalent in HAVELLS/LUKER/PHILIPS
Supply and fixing of LED tube light fittings with 20 Watt, 4 feet (White/worm white colour as required at site ) trim linea neu is a PC batten, Compact appearance, simple and versatile in nature makes it as long lasting, efficiency solution for offices and other commercial spaces efficacy 100 lm/W , THD ≤ 15% with operating voltage range 150-300V, 50Hz with driver efficency > 85%,surge voltage withstand 2.5KV,Power factor ≥ 0.9 ,energy efficient fitting surface mounted including connecting up with two/three core cable complete all as specified and directed Make: CG Cat Part No :CCS-102-20-65-SL-DP-NWH or equivalent make to Luker/ Havells/Philips Note:Quoted rate is inclusive of any other misc materials required for fixing new fittings
Supply and fixing of LED tube light fittings with 10 Watt 2 feet (White/worm white colour as required at site ) trim linea neu is a PC batten, Compact appearance, simple and versatile in nature makes it as long lasting, efficiency solution for offices and other commercial spaces efficacy 100 lm/W , THD ≤ 15% with operating voltage range 150-300V, 50Hz with driver efficency > 85%,surge voltage withstand 2.5KV,Power factor ≥ 0.9 ,energy efficient fitting surface mounted including connecting up with two/three core cable complete all as specified and directed Make: CG Cat Part No :CCS-102-10-65-SL-DP-NWH or equivalent make to Luker/ Havells/Philips Note:Quoted rate is inclusive of any other misc materials required for fixing new fittings
S & F of wall mounting decorative fittings of capacity 9 watts including 9 watts of LED bulb white/warm as required at site including fixing arrangement of light fittings complete all as specified and as directed Make: Philips Model No : 34302 or equivalent CG/Havells/Luker
S&F in repair of (CRYSTA COB SWIVEL) energy efficient 1x7W 3000K (white /yellow colour ) LED spotlight for low ceiling height applications round in shape, pressure die-cast aluminium housing, spring loaded clips for easy mounting complete all as directed. Make : Havells (Model No. LHEEGEPBIE1W009) or equivalent in Philips(7W COB PRO)/CG
S&F 25 Watts LED security light fitting with aesthetically designed COB LED ensure efficient optics and uniform distribution of light, for street light application. Pressure die cast aluminium housing powder coated in graphite grey and toughened glass of IP 65, including necessary fixing arrangements as per site requirements class-1 of model : Freedom of make CG complete all as specified and as directed. MAKE: CG (Cat Part No : TRP-415-25-57-SL-LM-NBK) or equivalent make of Philips/ C&S
S&F 9 Watts holder type LED lamp 230 Volts, 50Hz complete all as specified and as directed. MAKE: PHILIPS / C&S/ HAVELLS
S&F 7 Watts retrofit holder type LED lamp 230 Volts, 50Hz complete all as specified and as directed. MAKE: PHILIPS / HAVELLS/ CROMPTON GREAVES
S&F LED Strip light, 60 LED per metre, 28watts with driver, 2400 Lumen, 5 metre length, dimension 8mm wide x 3mm thick, including all fixing arrangment as per site requirement complete all as specified and as directed. The cradle is provided for monitoring purpose all as directed. Make: Philips Model: Skycove 28watt LED strip/CG/ Havells
S&F capacitor 2.5mfd, 230 Volts for ceiling fans including taking out old unserviceable one complete all as specified and as directed. MAKE: CAPCO/UNIVERSAL/TIBCON/EPCOS
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Repair to LED light /PTLS of any model/make/rating in position including testing of serviceability of connected accessories, and wiring upto respective switch/control unit including and replacing unserviceable items such as drivers , holder and making light functional. Note: (i) All the spares such as drivers, holder, LED tubes etc including replacing will be will measured and paid separately (ii) The representative of the contractor shall report to Engineer-in-charge/JE on daily basis to carry out repairs to light fitting and completion report to be submitted all as specified and as directed
S&F PVC insulated copper conductor cable of size 2.5Sqmm, 1100 Volts grade, Heavy Duty, served with inner sheathing (flexible) industrial cable complete all as specified.
S&F PVC insulated aluminium flat twin core cable of size 4.0Sqmm, 1100 Volts grade, Heavy Duty, weather proof complete all as specified.
S&F in repairs only electronic drivers for 10 to 24 watt LED post top luminaire / LED light fittings operated at input AC voltage 85 to 265 Volts, 50Hz, output DC voltage 42 to 65 Volts, 300MA, P.F > 0.95 incl necessary fixing arrangment as per site requirement complete all as specified and as directed. MAKE: PHILIPS/ CROMPTON GREAVES/ HAVELLS/ LUKER
Removing and refixing the following during Addn/ Altn/ modification of existing structure:-
Light fixture/ switch socket outlet of any type and any capacity
Ceiling Fan/ Exhaust Fan of any sweep
Split Air Conditioner of any capacity
S&F Step light 2watts including taking down old unserviceable light fitting complete all as specified and as directed Make: Philips Cat No: 30974 2 Watt LED ceiling light fixture or equivalent in CG/ Havells/ Luker
M/S VISHAL CONSTRUCTION
Sree Tirumala Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .