Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.3 LAdmitted-Finance | -15.99% | ₹8.3 L | L1 | Admitted-Finance |
| 2 | L2₹8.3 LAdmitted-Finance | -15.55% | ₹8.3 L | L2 | Admitted-Finance |
| 3 | L3₹8.4 LAdmitted-Finance 4 KRISHNA COLONY AGRA ROAD JAIPUR | -15.00% | ₹8.4 L | L3 | Admitted-Finance |
| 4 | L4₹9.6 LAdmitted-Finance | -3.11% | ₹9.6 L | L4 | Admitted-Finance |
Tender Value
₹9.9 L
EMD Value
₹19,720
Closing Date
19 Feb 2026, 6:00 pmClosed
EXECUTIVE ENGINEER PWD CITY DN III JAIPUR
EXECUTIVE ENGINEER PWD CITY DN III JAIPUR
Improvement for Overall Safety Work in Sawai Man Singh Stadium, Jaipur (Plumbing work)
2026_CEPWD_538988_1
ST NIT 91/2025-26 EE PWD CITY DN III JAIPUR
Open Tender
Civil Works
30 days
JAIPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
EE PWD CITY DN III JAIPUR/ MD RISL BY EGRASS
₹19,720
Yes
20 Feb 2026
16 Feb 2026
20 Feb 2026
16 Feb 2026
19 Feb 2026
16 Feb 2026
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity.
Hoisting Charges for each floor : For items 2.26.5 to 2.26.8
P&F Divertors in water supply lines for walls, wash basin etc
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 20mm nominal size
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 25 mm nominal size
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 50 mm nominal size
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 20mm nominal bore.
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 25mm nominal bore.
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 50mm nominal bore.
P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonry chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concretee, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm.
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 160 mm dia
Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concretee 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth up to 0.5 M
Supplying and fixing Ferro- cement cover with C.I. frame for chambers & man holes of size. 500mm dia 25 Kg.-do-70 MT centre point load seal type (Heavy duty.)
Labour charges for making connection of sewer line through main hole.
Mechanised Cleaning of sewer line of diameter upto 200mm with the help of trolley mounted electrical driven machine having flexible steel springs of length 20ft. Each which are rotated with the help of electric motor and clutch assembly.
Mechanised Cleaning and desilting of manhole/sewer line chambers With the help of mechanical bucket which gets open and close through levers. Depth upto 1.0 mtr.
Excavating trenches of required width for pipe cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.: All kinds of soil Pipes cables, etc. exceeding 80mm dia but not exceeding 300mm dia.
Carriage of Material Earth, Sand, Lime, Morrum manure or sludge including loading and unloading For 20 Km.
Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.
Add Extra if I/rail section is used
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
Tendernotice_2.pdf
PDF • 3.23 MB
Tender_document_91_1.pdf
Tender Documents • 6.08 MB
BOQ_961089.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid