Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC AT SAWANG GOMIA BOKARO JHARKHAND 829128 | BOKARO | BOKARO | JHARKHAND | 829128 | L1 | Accepted-AOC aoc | |
| 2 | Rejected-Technical KATHARA DIST BOKARO 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Rejected as Not L1 | |
| 3 | Rejected-Technical AT PO JARANGDIH BOKARO | JARANGDIH | BOKARO | JHARKHAND | - | Rejected-Technical Rejected as not L1 |
Tender Value
Refer Docs
EMD Value
₹1,900
Closing Date
29 Aug 2022, 4:00 pmClosed
Project Engineer (EnM), Kathara Colliery
P.E. (EnM), Office of the PO, Kathara Colliery
Electrical repairing / re-wiring and changing of electrical items of different places i.e. river side pump house room, C and D colony pump house room, 9.0 staff room and russian colony transformer etc. under Kathara Colliery Township.
2022_CCL_253698_1
PO(KTC)/PE(EnM) /E-Tender/2022-23/46
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
P.E. (EnM), Office of the PO, Kathara Colliery
AS PER NIT
4 documents required · 4 mandatory
₹1,900
11 Apr 2023
18 Aug 2022
30 Aug 2022
19 Aug 2022
29 Aug 2022
19 Aug 2022
19 Aug 2022 - 25 Aug 2022
Amount
Wiring for light point /fan point/exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduct, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1. Group ‘C’
Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 1). 5/6 Amps Switch
2). 3 Pin 5/6 Amps Socket out let
3). 15/16 Amps Switch
4). 6 Pin 15/16 Amps Socket out let
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing followings way, single pole neutral, sheet steel, MCB distribution board, 240 volts, on surface / recess, completed with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator). I) 8 way, Double Door
Supplying and fixing 5 Amps to 32 Amps rating, 240/415 volts, ‘C’ curve, miniature circuit breaker suitable for inclusive for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. I) Single pole and neutral.
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC consult as required. I). 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC consult as required. I). 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC consult as required. I). 2 X 4 sq.mm + 1 X 4 sq.mm earth wire
Providing of service wire twin core copper (4sq.mm)
Providing of ICDP Switch 32Amp, 240Volt
Providing of PVC wood board (8 x 12)
Labour Charges of Sl. No. 1.12 to 1.14
Total impact of GST for the purpose of CTC
M/S JAY GURU CONSTRUCTION
M/S TIGER ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .