Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.5 LAccepted-AOC | 1 | Accepted-AOC Lowest Accepted Bidder | |
| 2 | 2₹22.5 L+₹5.7 L (33.8%)Rejected-AOC | 2 | Rejected-AOC Lowest Accepted Bidder is M/S Bhadu Builders |
Tender Value
₹24.9 L
EMD Value
₹49,720
Closing Date
9 Jan 2023, 6:00 pmClosed
Col Avik Saxena, CWE Bikaner
HQ CWE Bikaner, Mil Stn Bikaner, PIN-334001
Repair/ maintenance of DG Sets, EOT Cranes and Mechanical Laundry, Incinerator and connected work under GE (A) Suratgarh
2022_MES_568935_1
CA No CWE BKN-Token No. 59/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Suratgarh
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (A) Suratgarh
₹49,720
Yes
6 Mar 2023
13 Dec 2022
16 Jan 2023
13 Dec 2022
9 Jan 2023
27 Dec 2022
13 Dec 2022 - 20 Dec 2022
Amount
Periodical maintenance of 1250 KVA capacity DG Set at 184 MH (Make-Cummins) and ensuring smooth functioning of DG Set complete all as specified and as directed. Notes :- (i) Spare parts, accessories, oil, filters, etc required for maintenance of DG Set shall be measured and paid for separately as “Supply only” under relevant items of this Schedule. (ii) The rate quoted shall include the maintenance & repairs and not inclusive of major repair / overhauling of DG Set. In case of any dispute between contractor & GE regarding this aspect, the decision of Accepting Officer shall be final & binding. (iii) Spare parts, accessories, oil, filters, etc for repair shall be procured from manufacturer’s authorised dealer only. (iv) All tools, testing instruments shall be arranged by the contractor including necessary transport. (v) The fixing/labour element for items catered here-in-after as “Supply only” shall be deemed to be included in the quoted rate of this item.
All as per serial item No 1.00 here-in-before but 625 KVA capacity DG Set at 184 MH (Make-Cummins) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 320 KVA capacity DG Set at KLP Filteration Plant (make-Cummins) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 250 KVA capacity DG Set at Raj canal Pump house (Make-Kirloskar) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 160 KVA capacity DG Set at New filtration plant KLP PH and STP MAP Ph-II (Make : Kirloskar) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 140 KVA capacity DG Set at KLP Sig centre (Make : Kirloskar) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 125 KVA capacity DG Set at STP PH-I (Make : Kirloskar) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 110 KVA capacity DG Set at 10 Corps Zonal work shop (Make : Cummins) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 100 KVA capacity DG Set at KLP Ops Room (Make : Rustom) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 100 KVA capacity DG Set at Lt AD Pump House and MAP PH-II Pump House (Make : Kirloskar) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 100 KVA capacity DG Set at SASF Birdhwal (Make : CG) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 100 KVA capacity DG Set at ILP Sig Centre (Make : Ashoka Leyland) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 63 KVA capacity DG Set at MAP Phase-I Pump House, Old KLP Pump House, Vaidya Marg, Sunder Ji Marg, Near 6(I) Offrs Mess and Inf Bn PH (Make : Kirloskar) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 63 KVA capacity DG Set at Ashoka Auditorium (Make : Ashoka Leyland) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 40 KVA capacity DG Set at FOL Depot (Make : Cummins) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 25 KVA capacity DG Set at 7 Garh PH, 62 Car PH, 815 CETC "A", "B" & "C" location and NKT Ascon Node (Make : Kirloskar) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 20 KVA capacity DG Set at STP 14 Mech and Intermediate Pump House (Make : Kirloskar) complete all as specified and as directed.
All as per serial item No 1.00 here-in-before but 7.5 KVA capacity DG Set at 85 Armd Regt KSP (Make : Cummins) complete all as specified and as directed.
Supply only Bypass filter element with ‘O’ ring for 1250 KVA capacity DG Set as required at site complete all as specified and as directed. Make : As per existing / recommended by OEM.
All as per serial item No 19.00 here-in-before but for 625 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 19.00 here-in-before but for 320 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 19.00 here-in-before but for 250 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 19.00 here-in-before but for 160 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 19.00 here-in-before but for 140 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 19.00 here-in-before but for 125 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 19.00 here-in-before but for 110 KVA capacity DG Set complete all as specified and as directed.
Supply only lubrication oil filter element with 'O' ring for 1250 KVA capacity DG Set as required at site complete all as specified and as directed. Make : As per existing / recommended by OEM.
All as per serial item No 27.00 here-in-before but for 625 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 320 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 250 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 160 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 140 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 125 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 110 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 100 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 63 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 40 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 25 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 20 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but for 7.5 KVA capacity DG Set complete all as specified and as directed.
Supply only Air filter element inner and outer with 'O' ring for 1250 KVA capacity DG Set as required at site complete all as specified and as directed. Make : As per existing / recommended by OEM.
All as per serial item No 41.00 here-in-before but for 625 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 320 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 250 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 160 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 140 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 125 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 110 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 100 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 63 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 40 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 25 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 20 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 41.00 here-in-before but for 7.5 KVA capacity DG Set complete all as specified and as directed.
Supply only fuel filter element with 'O' ring for 1250 KVA capacity DG Set as required at site complete all as specified and as directed. Make : As per existing / recommended by OEM.
All as per serial item No 55.00 here-in-before but for 625 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 320 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 250 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 160 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 140 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 125 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 110 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 100 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 63 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 40 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 25 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 20 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 55.00 here-in-before but for 7.5 KVA capacity DG Set complete all as specified and as directed.
Supply only fan belt for 625 to1250 KVA capacity DG Set as required at site complete all as specified and as directed. Make : Fenner / Dunlop
All as per serial item No 69.00 here-in-before but for 250 to 320 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 69.00 here-in-before but for 100 to 160 KVA capacity DG Set complete all as specified and as directed.
All as per serial item No 69.00 here-in-before but for 7.5 to 63 KVA capacity DG Set complete all as specified and as directed.
Supply only distilled water to be filled in batteries complete all as specified and as directed.
Supply only ignition switch with key for DG sets of any capacities complete all as specified and as directed. Make : As per existing / recommended by OEM.
Supply only battery cable of size 70 sqmm PVC insulated multi stranded copper conductor single core cable (ISI marked) with necessary lugs complete all as specified and as directed.
Supply only Coolant for top up radiator of DG set complete all as specified and as directed. Make & Grade : As per existing / recommended by OEM.
Supply only Water temperature gauge for DG Set complete all as specified and as directed. Make : As per existing / recommended by OEM.
Supply only oil pressure gauge assembly for DG Set complete all as specified and as directed. Make : As per existing / recommended by OEM.
Supply only oil temperature gauge for DG Set complete all as specified and as directed. Make : As per existing / recommended by OEM.
Supply only flexible braided hydraulic hose 5/8" dia x 600 mm length including suitable check nuts & washers for DG Set complete all as specified and as directed. Make : As per existing / recommended by OEM.
S&F in replacement electronic Automatic Voltage Regulator (AVR) of 100 V, 8 Amps suitable for DG Set of capacity upto 100 KVA including necessary terminal’s sleeves etc as required at site of any type and make of DG Sets, complete all as specified and as directed. Make : As per existing / recommended by OEM.
M&L for electronic Automatic Voltage Regulator (AVR) of 50 V, 16 Amps suitable for DG Set of capacity from 100 KVA to 320 KVA including necessary terminal’s sleeves etc as required at site of any type and make of DG Sets, complete all as specified and as directed. Make : As per existing / recommended by OEM.
Supply only solenoid switch suitable for any capacity DG set complete all as specified and as directed. Make : As per existing / recommended by OEM.
Supply only lubricant oil SAE 20 W - 40 for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling in DG Sets complete all as specified and as directed. Make : Castrol / Power Supreme
Supply only battery terminal heavy duty made of brass with bolts and washers all as required at site complete all as specified and as directed.
M&L for taking down unserviceable fuel injection pump from any type/ capacity DG set, carrying to workshop for repairing including necessary spares and calibration, refixing the same duly repaired to its original position and testing for its serviceability at site, complete all as specified and directed.
S&F in replacement 180 Ah, 12 V maintenance free battery and initial charging complete including inbuilt charger including required electrolyte/distilled water etc and fixing to DG Set, complete all as specified and as directed.
S&F in replacement 90 Ah, 12 V maintenance free battery and initial charging complete including inbuilt charger including required electrolyte/distilled water etc and fixing to DG Set, complete all as specified and as directed.
S&F in replacement 160 Ah, 12 V maintenance free battery and initial charging complete including inbuilt charger including required electrolyte/distilled water etc and fixing to DG Set, complete all as specified and as directed. Note for serial item No. 87.00 to 89.00 : 24 Months replacement warranty to be given by the contractor without any extra cost.
S&F in replacement Self starter assembly for DG set of 110 to 320 KVA, 24 Volts DC including testing complete all as specified and as directed. Make : Lucas TVS or as per existing / recommended by OEM.
S&F in replacement Self starter assembly for DG set of 7.5 to 100 KVA, 12 Volts DC including testing complete all as specified and as directed. Make : Lucas TVS or as per existing / recommended by OEM.
M&L for taking out unserviceable alternator from 63 KVA to 250 KVA capacity DG set, transportation to workshop for repair, rewinding with existing size copper conductor wire, varnishing, drying, refixing, connecting and testing, complete all as specified and as directed. Make : As per existing / recommended by OEM.
S&F in replacement Rubber hose set for 20 KVA to 100 KVA capacity DG set radiator, complete all as specified and as directed. Make : As per existing / recommended by OEM.
S&F in replacement Rubber hose set for 110 KVA to 320 KVA capacity DG set radiator, complete all as specified and as directed. Make : As per existing / recommended by OEM.
S&F in replacement complete PLC system for 63 to 100 KVA DG set as per on ground existing Make complete all as specified and as directed.
M&L for making smooth surface by scratching the old paint and rubbing with emery paper, filling putty in dents, where required, and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer with spraying process including writing of SM / MES number on DG set for 20 KVA to 100 KVA capacity DG set, complete all as specified and as directed.
M&L for making smooth surface by scratching the old paint and rubbing with emery paper, filling putty in dents, where required, and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer with spraying process including writing of SM / MES number on DG set for 110 KVA to 250 KVA capacity DG set, complete all as specified and as directed.
S&F in replacement turbo charger, complete all as specified as directed. Make:- Holest or as per existing / recommended by OEM.
M&L for opening/dismantling of 63 KVA to 100 KVA capacity DG set, disconnecting all connections from panel to terminal box, repair/replacing the field coils to the alternator, refixing the field coils to the alternator after drying the varnish and making the electric connections to terminal box with proper brass nut bolts and washers, testing and commissioning to the entire satisfaction of Engineer-in-Charge, complete all as specified and as directed.
M&L for dismantling radiator from engine, transporting it to work shop, repair of leakage pipes, cleaning the radiator with cleaning agents, re-assembling the Engine completely to entire satisfaction of Engineer-in-Charge, complete all as specified and as directed.
S&F Stainless steel butt hinges for generator canapoy/ enclosure having minimum thickness 5mm and size 75mmx100mm with nut and bolt fixing arrangement complete all as specified and as directed.
Inspection/checking of AMF panel of DG set of capacity 40 KVA to 100 KVA installed at various installations of any make and shape and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMF panel as detecting during inspection or pointed out by representative of department and carry out maintenance complete all as specified and as directed. Note :- Spare parts required shall be measured and paid for separately as “Supply only” under respective items of BOQ.
Supply only 4 Pole power contactor with AC coil 185 Amps, 3 phase 415 volt, 50 HZ, 2 NO + 2 NC with integrated auxiliary contacts suitable for AMF panels complete all as specified and as directed. Make : Legrand Cat part No 416280 or equivalent in Havells / GE / L&T / Siemens
Supply only Pre Magnetic Contactor 150A/270V, 3 Pole with coil 24 volts DC (Dual) (Make : Subtech) complete suitable for AMF panels complete all as specified and as directed.
Supply only Engine start relay 12/24 Volt DC suitable for AMF panels complete all as specified and as directed. Make : Eagle Man / PIC or as per existing / recommended by OEM.
Supply only frequency meter 45 to 55 Hz, AC 415 volt suitable for AMF panels complete all as specified and as directed. Make : AE / Premier or as per existing / recommended by OEM.
Supply only cranking relay 12/24 volts DC 8/11 stage suitable for AMF panels complete all as specified and as directed. Make : Eagle Man or as per existing / recommended by OEM.
Supply only cranking relay 220 volts AC 8/11 stage suitable for AMF panels complete all as specified and as directed. Make : Eagle Man or as per existing / recommended by OEM.
Supply only indicator lamp assembly LED type with red / green / blue for phases R,Y,B suitable for AMF panels complete all as specified and as directed.
M&L for replacement of unserviceable / worn out control wiring of AMF panel of DG set of capacity upto 100 KVA with existing size of cable and testing complete all as specified and as directed.
S&F in replacement OFF load change over switch of 160 Amp Capacity with Sheet Steel Enclosure with necessary mounting accessories, complete all as specified and as directed. Make : Havells / L&T / Legrand / C&S
S&F in replacement OFF load change over switch of 200 Amp Capacity with Sheet Steel Enclosure with necessary mounting accessories complete all as specified and as directed. Make : Havells / L&T / Legrand / C&S
M&L for control wiring with single core copper cable of size 2.5 sqmm (ISI marked) from AMF panel to DG set complete all as specified and as directed.
M&L for MS / ERW conduit 20mm dia (ISI marked) burried in ground / fixed to floor / wall with all fittings for passing of control wiring from AMF to DG set complete all as specified and as directed.
S&F in replacement Battery charger 24 V 10 A panel mounted operating on 230 Volt single phase 50 Hz supply complete all as specified and as directed.
Inspection/Checking and repair/servicing of EOT gantry crane double girder type track rail and load chain hook having span of 12.5 Mtr with traverse of 60 x 60 mtr and lift 6 mtr capacity 10 Ton, carrying out necessary cleaning, including greasing of all movable parts, filling of gear oil, stripping down all other related parts etc, complete overhauling of Crane all as per manufacturer’s instructions complete all as specified and directed. Note : Spare parts, gear oil, etc shall be measured and paid for separately as “Supply only” under respective items of BOQ.
All as per serial item No 117.00 here-in-before but 5 Ton capacity EOT gantry crane complete all as specified and directed.
All as per serial item No 117.00 here-in-before but 2 Ton capacity EOT gantry crane complete all as specified and directed.
M&L for fault finding in control panel of EOT Crane 10/5/2 Ton Capacity, repairing to control panel after finding out the faults if any including replacement of spare parts, rewiring to the panel board with existing size stranded copper wire complete all as per site requirement for smooth functioning of control panel including scraping out old paint, clean stain oily spot thoroughly and painting externally and internally with two coats of synthetic enamel paint by using spray gun (without any damage to components inside) complete all as directed. Note : Spare parts shall be measured and paid for separately as “Supply only” under respective items of BOQ.
Supply only limit switch (Rotary type/ Lever type for Hoisting motion and L.T., CT motion) complete all as specified and directed. Make : As per existing / recommended by OEM.
Supply only new gear oil 50 grade as per IS:8406/1993 complete in the speed control/transfer gear mesh box / sumps / boxes / tanks of LT / CT / main hoist / Auxiliary hoist of EOT / HOT / Monorail cranes. Make : As per existing / recommended by OEM.
S&F Power contactor 3 Pole, 65 Amps, 230 Volt 2 NO + 2 NC Auxiliary Contacts complete all as specified & as directed. Make : Legrand Cat Pt No 416166 or equivalent in Siemens / BCH.
S&F Power contactor 3 Pole, 32 Amps, 230 Volt 2 NO + 2 NC Auxiliary Contacts complete all as specified & as directed. Make : Legrand Cat Pt No 416126 or equivalent in Siemens / BCH.
S&F Power contactor 3 Pole, 18 Amps, 230 Volt 1 NO + 1 NC Auxiliary Contacts complete all as specified & as directed. Make : Legrand Cat Pt No 416106 or equivalent in Siemens / BCH
S&F Thermal over load relay Range 12-18 Amps complete all as specified & as directed. Make : Legrand Cat Pt No 416673 or equivalent in Siemens / C&S
S&F Thermal over load relay range 22-32 Amps complete all as specified & as directed. Make : Legrand Cat Pt No 416676 or equivalent in Siemens / C&S
S&F in replacement Step down Transformer copper wound 440 to 110/120 Volts output double stage complete all as specified and as directed.
M&L for dismantling and Rewinding of 3 HP to 5 HP electric motor with supper enamelled copper wire existing gauge including replacement of two Nos bearings, insulating material and re-fixing in position after necessary repairs complete all as specified & as directed. Make of bearing : SKF / NBC Make of winding wire : CHETAK / FINOLEX / EMGEE / DEVIDAYAL / ASIAN Note : Labour & transportation for carry out motor to workshop for repair and carry back after repair is included in the unit rate of the item.
M&L for dismantling and Rewinding of 7.5 HP to 15 HP electric motor with supper enamelled copper wire existing gauge including replacement of two Nos bearings, insulating material and re-fixing in position after necessary repairs complete all as specified & as directed. Make of bearing : SKF / NBC Make of winding wire : CHETAK / FINOLEX / EMGEE / DEVIDAYAL / ASIAN Note : Labour & transportation for carry out motor to workshop for repair and carry back after repair is included in the unit rate of the item.
S&F in replacement Remote control wire PVC copper conductor 1.5 sqmm, 16 Core multi standard (ISI marked) complete all as specified & as directed.
S&F in replacement hauling cable PVC copper multi standard copper conductor 10 Sqmm, 3 core with cable loader complete all as specified & as directed.
S&F in replacement magnetic type brake assembly for left right motor 3 HP complete all as specified & as directed.
Repair to reduction Gear box of 10 Ton / 5 Ton capacity EOT Crane, with & including following repairable items complete all as specified & as directed :- (a) White manth Bronze Gear - 01 No. (b) Burm of steel - 01 No. (c) Ball Bearing - 04 Nos. (d) Oil seal - 02 Nos. (e) Gear oil
Inspection & checking of Mechanical laundry steam boiler of capacity 200 Kg/hr and finding of fault by checking control devices, claibration of PLC, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including descaling the boiler and making connections complete all as specified and as directed. Notes : (i) All spare parts for repair shall be procured from manufacturer’s authorised dealer only. (ii) All tools, testing instruments shall be arranged by the contractor including necessary transport. (iii) The fixing/labour element for spare parts required to be replaced shall deemed to be included in quoted rates of this item and spare parts shall be measured and paid for separately as “Supply only” under respective items of this Schedule.
Inspection and checking of washer Extractor of Capacity 30 Kgs make Ramson and findng of fault by checking control devices, claibration of PLC, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc. removing the defects and refixing in its original position including making connections complete all as specified and directed. Notes : (i) All spare parts for repair shall be procured from manufacturer’s authorised dealer only. (ii) All tools, testing instruments shall be arranged by the contractor including necessary transport. (iii) The fixing/labour element for spare parts required to be replaced shall deemed to be included in quoted rates of this item and spare parts shall be measured and paid for separately as “Supply only” under respective items of this Schedule.
Inspection & checking of Drying tumbler of capacity 30/50 Kg (make Febcare/Ramson) and finding of fault by checking control devices, claibration of PLC, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed. Notes : (i) All spare parts for repair shall be procured from manufacturer’s authorised dealer only. (ii) All tools, testing instruments shall be arranged by the contractor including necessary transport. (iii) The fixing/labour element for spare parts required to be replaced shall deemed to be included in quoted rates of this item and spare parts shall be measured and paid for separately as “Supply only” under respective items of this Schedule.
Inspection & checking of Flat work ironer front feed and rear return type and finding of fault by checking control devices, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed. Notes : (i) All spare parts for repair shall be procured from manufacturer’s authorised dealer only. (ii) All tools, testing instruments shall be arranged by the contractor including necessary transport. (iii) The fixing/labour element for spare parts required to be replaced shall deemed to be included in quoted rates of this item and spare parts shall be measured and paid for separately as “Supply only” under respective items of this Schedule.
Inspection & checking of flat body press machine and finding of fault by checking control devices, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed. Notes : (i) All spare parts for repair shall be procured from manufacturer’s authorised dealer only. (ii) All tools, testing instruments shall be arranged by the contractor including necessary transport. (iii) The fixing/labour element for spare parts required to be replaced shall deemed to be included in quoted rates of this item and spare parts shall be measured and paid for separately as “Supply only” under respective items of this Schedule.
Inspection & checking of air compressor and finding of fault by checking control devices, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed. Notes : (i) All spare parts for repair shall be procured from manufacturer’s authorised dealer only. (ii) All tools, testing instruments shall be arranged by the contractor including necessary transport. (iii) The fixing/labour element for spare parts required to be replaced shall deemed to be included in quoted rates of this item and spare parts shall be measured and paid for separately as “Supply only” under respective items of this Schedule.
Supply only SS seal bush
Supply only housing ring
Supply only Anabond (85 gm packing).
Supply only Flexible Pipe (Size: 1/2" X 1mtr.).
Supply only Temperature Controller for boiler of capacity 200 Kg/Hr.
Supply only Probe for Temperature Controller for boiler of capacity 200 Kg/Hr.
Supply only Steam Trap 1/2" for boiler of capacity 200 Kg/Hr.
Supply only bearing RVWE30 Big (bearing NU213).
Supply only bearing RVWE30 Small (bearing 6311).
Supply only mechanical seal RVWE30 (shaft seal 85mm jhon crane).
Supply only oil seal RVWE30.
Supply only Emergency switch red.
Supply only indicator red.
Supply only transformer 415/220 V AC tumble drier.
Supply only pump cylinder (pump bottle).
Supply only NRV as per sample or required at site for boiler of capacity 200 Kg/Hr.
Supply only data cable
Supply only Pneumatic Valve for (Y - Type, Size : 2")
Supply only Globe gate Valve 1".
Supply only Drain Valve for 30 KG.
Supply only Air solenoid valve.
Supply only Push Button.
S&F in replacement MS Pipe, heavy grade, 20mm bore, ISI marked, including all fittings complete all as specified and as directed.
S&F in replacement MS Pipe, heavy grade, 25mm bore, ISI marked, including all fittings complete all as specified and as directed.
Supply only sensor with RX / TX with controller power supply and wiring.
Supply only C.O.P push button suitable for passenger lift.
Supply only Landing car button suitable for passenger lift.
Supply only Car Gate Switch suitable for passenger lift.
Supply only Door operator drive controller power unit.
Supply only Break oil.
Supply only Variable Voltage Variable Frequency (VVVF) drive 12.5 HP 380/480 Volts AC 50 Hz, preprogrammed as per existing Lift Make: Schneider.
Supply only Rectifier card 110 V - 24 V output.
Supply only SMPS Card.
Supply only Main control Card.
Supply only Transformer Card, AC 110 Voltage.
Supply only Relay Board.
Supply only Timer card.
Supply only Gate lock switch.
Supply only Gate lock spring.
Supply only MOM Card
Supply only Control Transformer
Supply only track roller
Supply only track incentary
Supply only door shoe
Supply only door belt / door rope
Supply only Infra red sensor
Supply only door coupler assembly
Supply only final limit
Supply only emergency alarm
Supply only break liner
Supply only Main Hoist Rope of traction steel, atleast 19 strands wound about a core centre, circumference of rope 13 mm, factor of safety as given in relevant IS code with end nut lock complete all as specified and directed.
Supply only divertor pulley
S&F in replacement of LED down light fitting, 12 Watt recess mounted (for ceiling cutout dia150 mm), white 6000k in pressure die cast aluminium luminaire in powder coated white finish in round profile with seperate electronic driver with fixing frame and all eletrical connection complete all as specified and directed.
M&L for rewinding of motor for cabin fan 60 Watt single phase with replacement of unserviceable bearing, connector, pvc cable, etc complete all as specified and directed.
M&L for rewinding of motor 10 / 12.5 HP three phase with replacement of unserviceable bearing, connector, pvc cable, terminal plate etc. complete all as specified and directed.
Repair/overhauling to ARD system of lift by replacement to unserviceable control card, dry cell battery etc to make ARD serviceable and testing complete all as specified and directed. Note: Dry cell battery shall be measured and paid for seperately.
Supply only battery dry cell type 12 volts, 18 AH of elevator Automatic Rescue Device (ARD) with electrical connection complete all as specified and directed. Make : Exide Type EP18-12
M&L for repair to Variable Voltage Variable Frequency (VVVF) drive, 10/12.5/15HP, including repairing/ replacement of main control cord, IGBT card, diode, capacitor, rectifier, testing & re-fixing, software installation complete all as specified and directed.
Taking down the existing 2 Ton Capacity electric Control Panel from the Crane to ground level & removal of all old wiring, all contactors of different capacities, Transformer, Indicating lights, terminal block etc. (complete scrapping of old panel) after scrapping panel shall be painted with synthetic enammel paint with mounting plate, after painting all components are required to be changed with new one:- (i) Main MCB 63 Amps rated TPN - 01 No (ii) Main Contactor 40 Amps rated having coil voltage 415/110 Volts - 01 No (iii) Step down Tranformer 500VA having 415/110/36/24 Volts tapping - 01 No (iv) Veriable frequency drive 3.7 KW with D.B.R. - 01 No. (v) Contactor 18 Amps rated coil voltage 415/110 Volts - 04 Nos. (vi) Brake Contactor 10 Amps rated - 03 Nos. (vii) Wiring with suitable P.V.C. flexible copper wire of suitable size with 20% cusion with thimbles. (viii) Suitable terminal blocks for making electrical connections
M&L for fixing of New 'C' Track system for free movement of Push Button station, including fabrication & fixing of iron bracket complete all as specified and directed.
M&L in replacement of steel wire rope 9mm of having 6x36 FMC construction, complete all as specified and as directed. Make:- Usha Martin / Mahadev. (Test certificate of wire rope shall be submitted by contractor)
M&L in replacement of 11KW V.F.D. drive with D.B.R. mounted in a sheet steel enclosure made out of M.S. Sheet not less than 16 SWG for 10 TON capacity EOT Crane including programming of drive complete all as specified and as directed. Make:- Delta / Schnieder / L&T
M&L for preparation of old surfaces of 10/5 TON EOT crane Gantry and Garder L.T. (approx 69 Mtr) and C.T. (approx 12.5) for painting with two coats of existing colour (yellow & Grey) anti corrosive paint of first quality after one coat of red oxide complete all as specified and as directed.
S&F in replacement 01 HP motor Pump for Boiler having 600 PSI, 12 LPM (litre per minute) function capacity having 950 RPM as per ISO 9001:2008 CO as revised time to time complete all as specified and directed.
M&L for preparation of old surfaces of Boiler chimeny for painting with two coats of aluminium anti corrosive paint of first quality after one coat of red oxide complete all as specified and as directed.
M&L for periodical maint of oil fired incinerator of which includes the following works. (a) Descalling of Gap between greads (b) Descalling of combution Chamber (c) Descalling of arch chamber (d) Descalling of stack arrester. (e) Overhauling burner nozzel blast tube pump, diffuser etc (f) Cleaning of Diesel tank and fuel lines Note:- (i) Rate includes for painting on Diesel Tank and writing in white paint date of cleaning and capacity. (ii) Contractor should attend day to day complaint of incenarator regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates. (iii) Spare parts shall be measured and paid separately.
M&L for galvanised steel sheet 5mm thick for fabrication of water tank (2.50m x 1.30m x 1.30m) for incinerator from structural steel sections conforming to Fe-290 Gde E-165, including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, supplied and fixed in repair complete all as specified and as directed. Note : - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge. (ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)
Suppyling, installing, testing and commissioning in replacement of factory made Outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre (vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :- Incoming: (a) 250 Amps aluminium bus bar including Neutral and Three phase - 01 Set (b) MCCB 4 Pole, 160 Amps rating, rupturing capacity 36 KA, 415 Volts - 01 No Make : L&T / Legrand / Schneider / ABB Outgoing: (a) MCCB 4 Pole, 100 Amp, rating, rupturing capacity 25 KA, thermal Magnetic release type -01 No, (b) MCB 63 Amps, SPN, rupturing capacity 25 KA - 03 Nos Make : MCCB/MCBs - L&T / Legrand / Schneider / ABB (c) Digital Volt and Amp Meter flush type 96X96mm including CTs suitable size - Each separately. (d) Internal all links & control cable and indicators - set of three
M&L for preparation of old surfaces of incenarator chimeny (Appx. 25 mtr long) for painting with two coats of aluminium anti corrosive paint of first quality after one coat of red oxide complete all as specified and as directed.
Inspection/checking and calibration of weighing machine of capacity 30 Ton by checking/repairing all the connections and cleaning of load beam cell, etc to make the machine serviceable and to measure actual weight by replacing defective parts, if any, complete all as specified and directed. Notes: The Cost of parts if repalced deemed to be included in item rate only.
Gupta Suppliers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .