Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹63,743.50Admitted-Finance | -37.89% | ₹63,743.50 | L1 | Admitted-Finance |
| 2 | L2₹78,142.49Admitted-Finance | -23.86% | ₹78,142.49 | L2 | Admitted-Finance |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 May 2026, 6:55 pmClosed
Commissioner, Municipal Corporation Udaipur
Municipal Corporation Udaipur, Town Hall Link Road
Sewerage Line laying and Repairing works at Various places in Ward no. 7 to 16 and 30,31,32 By ARC (e_08 / Nirman_03)
2026_DLB_559119_1
E_08_2026-27_Nirman_03
Open Tender
Civil Works
365 days
Udaipur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Commissioner, Municipal Corporation Udaipur
₹80,000
Yes
29 May 2026
14 May 2026
26 May 2026
14 May 2026
25 May 2026
14 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work for Sewer line and Manhole in excavation in foundation, trenches manholes, road side chambers etc. including dressing of sides and ramming of bottoms, including getting out the excavated
material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top
level including allowances for any additional excavation beyond the drawings (measurement for payment to be as per standard drawings), re-handling of material/earth to complete the task. In all types soils/ saturated soil such as moorum, sand, sandy silt,
clay, black cotton soil, kankar, etc. Depth upto 1.5 m | 1 | cum | 299 | ₹299 |
| 2 | Earth work for Sewer line and Manhole in excavation in foundation, trenches manholes, road side chambers etc. including dressing of sides and ramming of bottoms, including getting out the excavated
material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top
level including allowances for any additional excavation beyond the drawings (measurement for payment to be as per standard drawings), re-handling of material/earth to complete the task. In ordinary rock.
Depth upto 1.5 m | 1 | cum | 1,262 | ₹1,262 |
| 3 | Carriage of Materials by mechanical transport including
loading, unloading and stacking :: Earth up to 5km | 1 | cum | 254.76 | ₹254.76 |
| 4 | Providing at site, lowering & laying in trenches, aligning & jointing of PVC-U pipes (SN 8) as per IS 15328 (amended up to date) and as per specifications with rubber rings with socket and spigot joint,
(EPDM/SBR) for all depths for pipe length as per drawing and specification including hydraulic field testing (including the cost and
conveyance of water to site for testing) and commissioning etc complete as directed by Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the
outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.
110 mm Nominal Dia | 1 | mtr | 263.5 | ₹263.5 |
| 5 | Providing at site, lowering & laying in trenches, aligning & jointing of PVC-U pipes (SN 8) as per IS 15328 (amended up to date) and as
per specifications with rubber rings with socket and spigot joint, (EPDM/SBR) for all depths for pipe length as per drawing and specification including hydraulic field testing (including the cost and
conveyance of water to site for testing) and commissioning etc complete as directed by Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the
outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.
160 mm Nominal Dia | 1 | mtr | 548 | ₹548 |
| 6 | PProviding, fixing and constructing of pre-cast RCC M-40 grade
circular manholes with internal dia 1.0m and up to specified depth
having pre-cast RCC M-40 grade circular manhole cover frame (ID
0.56m, OD 0.92m), conical piece (top ID 0.56m, bottom ID 1.0m,
vertical height 0.805m, wall thickness 125mm), and circular rings of required heights (ID 1.0m, height 150/225/300/600 mm, wall thickness 125mm) below conical piece as per required depth of
manhole and having steel reinforcement in conical piece @ not less than 80 kg per cum of concrete, including cast-in-situ PCC M-10 grade (1:3:6) foundation of 1.625m dia and 150mm thickness, PCC M15 grade circular wall ID 0.925m, wall thickness 200mm, height equal to ID of sewer pipe + one wall thickness of pipe + 50 mm (to flush the manhole frame with road top, height of wall can be increased but not more than 100mm), PCC M15 grade benching and
channel portion and up to top level of sewer pipe etc complete with curing compaction and form work, supplying and fixing heavy duty SFRC manhole cover as per IS 12592 (Part I and II), supplying and fixing plastic encapsulated CI/MS foot steps / SFRC foot steps, including cost of shuttering, steel reinforcement, testing for water tightness etc. complete in all respect as per drawing, as per specification and the direction of the Engineer. Note:- Excavation of earth work and road cutting for manhole will be measured and paid
separately. Pre-cast RCC M-40 grade circular manholeconical piece with inbuilt cover and frame (height 0.805), cast-in-situ PCC M-10 grade oundation, PCC M15 grade circular wall ID 0.925m, wall thickness
200mm, wall height equal to ID of sewer pipe + one wall thickness of pipe + 50 mm, PCC M15 grade benching and channel portion. Depth of manhole shall be measured from top of manhole cover upto lowest invert of pipe. (Depth includes in the item= height of
Conical piece + ID of Sewer pipe + 1 Wall thickness of pipe +
50mm) | 1 | each | 14,500 | ₹14,500 |
| 7 | Constructing providing and fixing of pre-cast RCC M-40 grade circular Road Side Inspection Chamber including earthwork with following dia and depth cylindrical piece with 100mm wall thickness, inbuilt 100mm thick base slab, inbuilt cover & frame on top, provision
for 110mm OD in and out sewer connection with making proper inbuilt benching and channel with PCC M-15 grade including providing cast-in-situ 100mm thick base foundation of PCC M-10 grade, supplying and fixing circular precast SFRC Circular 300 / 450 mm dia manhole cover with frame MD-10 (as per IS-12592 amended upto date), including steel reinforcement minimum @ 80kg/cum, testing for water tightness complete in all respect as per drawing, specification and the direction of the Engineer. PrPre-cast Road side inspection chamber of 450mm dia (internal), 600mm depth and 750mm dia base foundation | 1 | each | 6,220 | ₹6,220 |
| 8 | Construction of House Sewer Connection inside and outside of Length up to 5 m
a dwelling properties to connect all the outlets of Kitchen, Bath,
toilet/WC of the property to existing inspection chamber of
Sewer Network, which includes Door-to-door survey of all
properties to be connected with Sewer Network, Preparation of
sketch / drawing of arrangement for each house with all the details
and obtain approval from Engineer In-charge or his representative
and Preparation of as built drawing (Layout plan) in AutoCAD for
each property / dwelling connection with sewer network up to
manhole. Including Dismantling of all type of flooring and roads,
i.e. BT/CC/WMM/interlocking block etc with mechanical cutter.
Including Required Excavation of pipe trench/chamber in all type of
strata of specified width up to all depth, Providing, laying, jointing
and aligning of PVC-U pipes (SN-8) as per 15328 (amended up to
date) / HDPE DWC (double wall corrugated) pipes of SN-8 grade as
per IS 16098 (amended up to date)/ SWR Pipes with required PVC/ DWC/SWR fittings with required level & location in buried position over bedding of 50 mm thick M-10 grade and in open position above Code No Description Unit Rate Rs. ground/floor with an encasing of pipe 50 mm cover at 3 sides with M10 grade concrete, Providing, laying, jointing and aligning 160 mm dia PVC-U pipes (SN-8) as per IS15328 (Amended up to date)
providing as sleeve to 110 mm dia PVC-U pipes / HDPE DWC (double wall corrugated) pipes (exposed to atmosphere) for crossing open drains, demolishing, If required and reconstruction of drain in original position with PCC M-10, Brick work with modular extruded burnt fly ash clay sewer bricks (Conforming
to IS: 4885 - 1988) in CM 1:4, 12 mm thick plaster in CM 1:3 and Construction of 2 Nos brick masonry chamber of bricks class designation 75 of 115 mm wall thickness in cement mortar 1:4, clear inside dimension 320 x 320 x 550 mm, 50 mm thick base PCC 1:3:6, providing & fixing 350 x 350 mm RCC precast cover with frame of LD-2.5, earth filling in gaps, finishing with PCC 1:3:6 inside the chamber, Chamber-1 with square mouth S.W. gulley trap P-type of size 100 x 100 mm as per IS 651: 1992 (amended up to date) with
CI grating, in slope around the mouth of Gulley Trap including
provision for fixing of 2 nos. 110 mm dia PVC-U pipe etc. to
connect a single inlet after connecting all the outlets of kitchen &
bath & outlet of this chamber will connect to Chamber-2 or
inspection chamber and the Chamber-2 with a provision for fixing of
2 nos. 110 mm dia PVC-U pipe etc. i.e. a single inlet after
connecting all outlets of toilet & WC of premises to exiting
Inspection chamber, Emptying of septic tank/soakage well etc.
disposing of sludge within a lead of 5 Km and taking out the
sewage, Bypass of septic tank/soakage well by providing, laying, jointing of 110 mm dia PVC-U pipes for all length from inlet to outlet, including PVC coupler, MS clamp and dismantling, repairing, making good the holes etc, Making connection with 110
mm dia PVC-U pipe with exiting inspection chamber (including making holes in Inspection Chamber) for pipes coming out from inside property and Chamber 1/2, making and repairing holes with CM in 1:4, repairing of floor and road with CC M-30 grade same as
original thickness of floor and roadwatering,backfilling, compaction and disposal of all surplus material and sewage etc. to a suitable location with all lead and lift, repairing of underground utilities, if damaged, Complete job to connect a dwelling premises
to sewer network including all material, labour, taxes, charges etc. as per Specifications, drawing and directions of Engineer I | 1 | each | 8,450 | ₹8,450 |
| 9 | Construction of House Sewer Connection inside and outside of Length more than 5 m and upto 10 m
a dwelling properties to connect all the outlets of Kitchen, Bath,
toilet/WC of the property to existing inspection chamber of
Sewer Network, which includes Door-to-door survey of all
properties to be connected with Sewer Network, Preparation of
sketch / drawing of arrangement for each house with all the details
and obtain approval from Engineer In-charge or his representative
and Preparation of as built drawing (Layout plan) in AutoCAD for
each property / dwelling connection with sewer network up to
manhole. Including Dismantling of all type of flooring and roads,
i.e. BT/CC/WMM/interlocking block etc with mechanical cutter.
Including Required Excavation of pipe trench/chamber in all type of
strata of specified width up to all depth, Providing, laying, jointing
and aligning of PVC-U pipes (SN-8) as per 15328 (amended up to
date) / HDPE DWC (double wall corrugated) pipes of SN-8 grade as
per IS 16098 (amended up to date)/ SWR Pipes with required PVC/ DWC/SWR fittings with required level & location in buried position over bedding of 50 mm thick M-10 grade and in open position above Code No Description Unit Rate Rs. ground/floor with an encasing of pipe 50 mm cover at 3 sides with M10 grade concrete, Providing, laying, jointing and aligning 160 mm dia PVC-U pipes (SN-8) as per IS15328 (Amended up to date)
providing as sleeve to 110 mm dia PVC-U pipes / HDPE DWC (double wall corrugated) pipes (exposed to atmosphere) for crossing open drains, demolishing, If required and reconstruction of drain in original position with PCC M-10, Brick work with modular extruded burnt fly ash clay sewer bricks (Conforming
to IS: 4885 - 1988) in CM 1:4, 12 mm thick plaster in CM 1:3 and Construction of 2 Nos brick masonry chamber of bricks class designation 75 of 115 mm wall thickness in cement mortar 1:4, clear inside dimension 320 x 320 x 550 mm, 50 mm thick base PCC 1:3:6, providing & fixing 350 x 350 mm RCC precast cover with frame of LD-2.5, earth filling in gaps, finishing with PCC 1:3:6 inside the chamber, Chamber-1 with square mouth S.W. gulley trap P-type of size 100 x 100 mm as per IS 651: 1992 (amended up to date) with
CI grating, in slope around the mouth of Gulley Trap including
provision for fixing of 2 nos. 110 mm dia PVC-U pipe etc. to
connect a single inlet after connecting all the outlets of kitchen &
bath & outlet of this chamber will connect to Chamber-2 or
inspection chamber and the Chamber-2 with a provision for fixing of
2 nos. 110 mm dia PVC-U pipe etc. i.e. a single inlet after
connecting all outlets of toilet & WC of premises to exiting
Inspection chamber, Emptying of septic tank/soakage well etc.
disposing of sludge within a lead of 5 Km and taking out the
sewage, Bypass of septic tank/soakage well by providing, laying, jointing of 110 mm dia PVC-U pipes for all length from inlet to outlet, including PVC coupler, MS clamp and dismantling, repairing, making good the holes etc, Making connection with 110
mm dia PVC-U pipe with exiting inspection chamber (including making holes in Inspection Chamber) for pipes coming out from inside property and Chamber 1/2, making and repairing holes with CM in 1:4, repairing of floor and road with CC M-30 grade same as
original thickness of floor and roadwatering,backfilling, compaction and disposal of all surplus material and sewage etc. to a suitable location with all lead and lift, repairing of underground utilities, if damaged, Complete job to connect a dwelling premises
to sewer network including all material, labour, taxes, charges etc. as per Specifications, drawing and directions of Engineer I | 1 | each | 10,900 | ₹10,900 |
| 10 | Providing and Fixing Minimum 0.63mm thick GI corrugated sheets (minimum width of each sheet shall be 60 cm) for covering the barricading in one/ two rows one above another and painting in red and white stripes as per the specifications and directions of the Engineer In-charge with proper fixing arrangements with GI limpet washers nuts and bolts complete in all | 1 | sqm | 147 | ₹147 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.74 MB
BOQ_995513.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid