| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-Failed to submit their original EMD and tender fee in the form of Demand draft in the drop box provided at COA office before closing date and time, hence tender will considered as invalid as per the NIT condition Sl.no 1 of d |
Tender Value
₹4.3 L
EMD Value
₹8,556
Closing Date
22 Nov 2021, 5:00 pmClosed
DIRECTOR CSIR-IICT
CSIR--IICT, HYDERABAD
Non Comprehensive Annual Maintenance Contract for DG sets and Synchronization Panel installed at CSIR-IICT, Hyderabad
2021_CSIR_92474_2
ESD/Elect/l-188/2021
Open Tender
Electrical Works
Item Rate
365 days
CSIR--IICT
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DIRECTOR CSIR-IICT
₹8,556
2 Dec 2021
15 Nov 2021
24 Nov 2021
15 Nov 2021
22 Nov 2021
15 Nov 2021
Amount
Providing non comprehensive annual maintenance for 500KVA DG Sets (Cummins & Volva Penta Make each 3 Nos.) as required for one year. The work includes regular monthly visits and break down calls whenever required. Periodic maintenance as per manufacturer’s schedule, Prompt troubleshooting and rectification, Check fuel, cooling, lubricating oil, air, exhaust, and electrical systems, Lubricating oil level and condition, Top-up / replace if required, Water / Coolant level and condition, Top-up / replace if required, Air restriction, Clean / change Air Cleaner element as required, Fuel level and sedimentation in fuel tank. Drain / replace water separator accordingly, Color of exhaust gases and act accordingly, Check for any leakage from of the systems, Check for any loose fasteners. Tighten accordingly, Electrolyte level in the battery. Top-up if required, Tightness of all battery connections. Tighten accordingly, Tension and condition of belts. Tighten / replace as required, Free flow of cooling air through radiator, Tightness if all cable connections, Notice for any overheating of cable terminals, All Instruments, Gauges and Relays functionality, Operation of D.G. Set in Manual/AMF mode, Check for any vibrations, Check for any abnormal sound, Check Voltage, Frequency, and Amperes etc. Adjust accordingly if required, Check alternator for overheating / abnormal noise, Check and Record all parameters as required and as directed by the engineer in charge.
Providing non comprehensive annual maintenance for 600KVA DG Set (Cummins Make) as required for one year. The work includes regular monthly visits and break down calls whenever required. Periodic maintenance as per manufacturer’s schedule, Prompt troubleshooting and rectification, Check fuel, cooling, lubricating oil, air, exhaust, and electrical systems, Lubricating oil level and condition, Top-up / replace if required, Water / Coolant level and condition, Top-up / replace if required, Air restriction, Clean / change Air Cleaner element as required, Fuel level and sedimentation in fuel tank. Drain / replace water separator accordingly, Color of exhaust gases and act accordingly, Check for any leakage from of the systems, Check for any loose fasteners. Tighten accordingly, Electrolyte level in the battery. Top-up if required, Tightness of all battery connections. Tighten accordingly, Tension and condition of belts. Tighten / replace as required, Free flow of cooling air through radiator, Tightness if all cable connections, Notice for any overheating of cable terminals, All Instruments, Gauges and Relays functionality, Operation of D.G. Set in Manual/AMF mode, Check for any vibrations, Check for any abnormal sound, Check Voltage, Frequency, and Amperes etc. Adjust accordingly if required, Check alternator for overheating / abnormal noise, Check and Record all parameters as required and as directed by the engineer in charge.
Providing non comprehensive annual maintenance for 140KVA DG Set (Cummins Make) as required for one year. The work includes regular monthly visits and break down calls whenever required. Periodic maintenance as per manufacturer’s schedule, Prompt troubleshooting and rectification, Check fuel, cooling, lubricating oil, air, exhaust, and electrical systems, Lubricating oil level and condition, Top-up / replace if required, Water / Coolant level and condition, Top-up / replace if required, Air restriction, Clean / change Air Cleaner element as required, Fuel level and sedimentation in fuel tank. Drain / replace water separator accordingly, Color of exhaust gases and act accordingly, Check for any leakage from of the systems, Check for any loose fasteners. Tighten accordingly, Electrolyte level in the battery. Top-up if required, Tightness of all battery connections. Tighten accordingly, Tension and condition of belts. Tighten / replace as required, Free flow of cooling air through radiator, Tightness if all cable connections, Notice for any overheating of cable terminals, All Instruments, Gauges and Relays functionality, Operation of D.G. Set in Manual/AMF mode, Check for any vibrations, Check for any abnormal sound, Check Voltage, Frequency, and Amperes etc. Adjust accordingly if required, Check alternator for overheating / abnormal noise, Check and Record all parameters as required and as directed by the engineer in charge.
Providing non comprehensive annual maintenance for Synchronization Panel for one year: - Non Comprehensive annual maintenance for 6x500KVA DG Set Synchronization Panel installed at CSIR-IICT, Hyderabad with 6Nos. Of Comap make IG NT Controllers with SCADA software, including all wiring & Electrical & Electronics parts excluding 12 Nos. ACB's. The work includes monthly visit of engineer, highly skilled technician & helper for regular checkup and emergency visits to resolve any issuees related to synchronization panel and its components. Periodic maintenance as per manufacturer’s schedule, All repairs related to electronic components of synchronization panel and related service for software of SCADA and performing routine tests and emergency tests as required and as directed by the engineer in charge.
UNIVERSAL ELECTRICALS
SHAKTI POWER LINES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .