Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAdmitted-Finance | ₹28.1 L | L1 | Admitted-Finance |
| 2 | L2₹29.5 L+₹1.4 L (5.11%)Admitted-Finance | ₹29.5 L+₹1.4 L (5.11%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | k manikandan L2 | IDEAL ENGINEERING CONSTRUCTIONS L1 |
|---|---|---|---|---|---|
| 1.00Development works | |||||
| 1.01 | Earth work for foundation in all soils and subsoils to the full depth as may be directed except in hard rock requiring blasting including shoring, strutting and baling out water wherever necessary and refilling the sides of foundations with excavated earth in layers not more than 15 cm thick well rammed and consolidated and depositing the surplus earth in places shown within initial lead and lift including levelling the site etc., complete complying with standard specidfications (a) first depth up to 2.00 m | 400 | cum | 215.88 ₹86,352 | 205.39 ₹82,156 Lowest |
| 1.02 | (b) Second depth 2.00m to 3.00 m | 130 | cum | 228.11 ₹29,654.3 | 217.03 ₹28,213.9 Lowest |
| 1.03 | Supplying and filling in foundation and basement with well gravel in layers of not more than 15 cm thick well rammed, watered and consolidated etc.,complete complying with standard specification | 614 | cum | 281.72 ₹1,72,976.08 | 268.03 ₹1,64,570.42 Lowest |
| 1.04 | Supplying and filling in foundation and baemet with crushed stone sand (M sand) in layers of not more than 15 cm well rammed watered and compacted etc., complete complying with standard specification | 170 | cum | 1,543.47 ₹2,62,389.9 | 1,468.5 ₹2,49,645 Lowest |
| 1.05 | Cement concrete of mix 1:4:8 (one of cement four of sand and eight of aggregate) using 40 mm gauge hard broken stone jelly including cost of conveyance of all materials to the site including form work and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams, bailing out of water, labour for mixing compacting, finising and curing, working at depths tools and plants and incidental chages such as sheeting, shoring and bracing and their subsequent removal etc., all complete as per standard specification. | 15 | cum | 5,313.79 ₹79,706.85 | 5,055.69 ₹75,835.35 Lowest |
| 1.06 | Supplying and errecting steel centering including necessary supports for plain surfaces for Reinforced Cement Concrete works such as column footing,column pedestals, plinth beam, grade beams, staircase steps etc., which requires only nominal strutting using mild steel sheets of size 90 mm x60 mm and 10 BG stiffened with welded mild steel angles of size 25 mm x 25mm x 3mm for boarding laid over siler oak joists of size 10cm x 6.5cm spaced at about 75 cm centre to centre or at suitable intervals etc., complete in all floors complying with standard specification(TNSS no or NBC no 30(S) 86, 86 AV,VI(S3)II (a) Footing, grade beam plith beam | 390 | sqm | 348.47 ₹1,35,903.3 | 331.55 ₹1,29,304.5 Lowest |
| 1.07 | (b) Beams and slabs | 20 | sqm | 1,058.86 ₹21,177.2 | 1,007.43 ₹20,148.6 Lowest |
| 1.08 | (c) Columns | 52 | sqm | 1,270.64 ₹66,073.28 | 1,208.92 ₹62,863.84 Lowest |
| 1.09 | Cement concrete of mix 1:3:6 (one of cement three of sand and six of aggregate) using 40 mm to 20 mm gauge graded hard broken stone jelly including cost of conveyance of all materials to the site including form work and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams, bailing out of water, labour for mixing compacting, finising and curing, working at depths tools and plants and incidental chages such as sheeting, shoring and bracing and their subsequent removal etc., all complete as per standard specification. | 90 | cum | 6,079.86 ₹5,47,187.4 | 5,784.55 ₹5,20,609.5 Lowest |
Tender Value
Refer Docs
EMD Value
₹34,800
Closing Date
17 Sept 2025, 3:00 pmClosed
Commissioner Nagercoil City Municipal Corporation
City Municipal Corporation Office Nagercoil 629001 Ph.No. 04652230984
Nagercoil Municipal corporation Development works like providing retaining wall, compound wall, filling the low lying area with earth and providing interlock paverblocks for the Urban primary Health care centre building at peruvilai (Christober colon
2025_MAWS_601745_1
220/2025-26/AEE_6th SFC
Open Tender
Civil Works
Lump-sum
90 days
Nagercoil Municipal corporation Development works
Registered Contractor
4 documents required · 4 mandatory
₹0
₹34,800
18 Sept 2025
8 Sept 2025
17 Sept 2025
8 Sept 2025
17 Sept 2025
8 Sept 2025
Amount
Development works
Earth work for foundation in all soils and subsoils to the full depth as may be directed except in hard rock requiring blasting including shoring, strutting and baling out water wherever necessary and refilling the sides of foundations with excavated earth in layers not more than 15 cm thick well rammed and consolidated and depositing the surplus earth in places shown within initial lead and lift including levelling the site etc., complete complying with standard specidfications (a) first depth up to 2.00 m
(b) Second depth 2.00m to 3.00 m
Supplying and filling in foundation and basement with well gravel in layers of not more than 15 cm thick well rammed, watered and consolidated etc.,complete complying with standard specification
Supplying and filling in foundation and baemet with crushed stone sand (M sand) in layers of not more than 15 cm well rammed watered and compacted etc., complete complying with standard specification
Cement concrete of mix 1:4:8 (one of cement four of sand and eight of aggregate) using 40 mm gauge hard broken stone jelly including cost of conveyance of all materials to the site including form work and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams, bailing out of water, labour for mixing compacting, finising and curing, working at depths tools and plants and incidental chages such as sheeting, shoring and bracing and their subsequent removal etc., all complete as per standard specification.
Supplying and errecting steel centering including necessary supports for plain surfaces for Reinforced Cement Concrete works such as column footing,column pedestals, plinth beam, grade beams, staircase steps etc., which requires only nominal strutting using mild steel sheets of size 90 mm x60 mm and 10 BG stiffened with welded mild steel angles of size 25 mm x 25mm x 3mm for boarding laid over siler oak joists of size 10cm x 6.5cm spaced at about 75 cm centre to centre or at suitable intervals etc., complete in all floors complying with standard specification(TNSS no or NBC no 30(S) 86, 86 AV,VI(S3)II (a) Footing, grade beam plith beam
(b) Beams and slabs
(c) Columns
Cement concrete of mix 1:3:6 (one of cement three of sand and six of aggregate) using 40 mm to 20 mm gauge graded hard broken stone jelly including cost of conveyance of all materials to the site including form work and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams, bailing out of water, labour for mixing compacting, finising and curing, working at depths tools and plants and incidental chages such as sheeting, shoring and bracing and their subsequent removal etc., all complete as per standard specification.
Providing and laying in position standardised concete mix M-25 grade in accordance with IS 456-2000 using 20 mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/cum and maximum water cement ratio of 0.55 including admixture(plasticiser/super plasticiser) in recommended proportions as per IS 9103 to accelerate related setting of concrete improve workability withouut imparing strength and durability with about (5.0cum), 7730 kg of 20 mm machine crushed stone jelly and with about (3.3 cum) 5156 kg of 10-12mm machine crushed stone jelly and with about(4.79 cum) 7670 kg of crushed stone sand (Msand) but excluding cost of reinforcement grill and fabriation charges, centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing etc.,and providing fixtures like fan clamps in the RCC flooor/roof slab wherever necessary withour claiming extra cost etc., complte complying with standard specifications and as directed by the departmesntal Officers. (a) Foundation and basement
(b) Ground floor
Supplying and fabrication of steel and placing in postion of MS/RTS for all RCC works as per design given including cost of steel and GI binding wire In floors ec., complete complying with standard specification in force per kilogram
Supplying and laying of concrete interlocking paver blocks of 63 mm thickness using rubber mould, approved make with grey colour including cost of conveyance of interlocking blocks and filling stone dust and spreading of stone dust to a thickness of 15 cm etc., all complete and as directed by the departmental Officers
Brickwork in cement mortar 1:5(one of cement and five of sand) using II nd class ground moulded bricks of size 9"x4 3/8"x2 3/4" including finising, curing etc., complete complying with standard specification (a) In ground floor
Plastering with cement mortar 1:5 (one of cement and five of sand ) 12 mm thickincluding all cost and conveyance of all materials to siteincluding cost of csemnt which will be purchased locally by the contractor and conveyance of the same to the actual work site and cost from work imcluding watering curing and all leads of good potable water and all other
Supplying fabricating and errecting M.S main gate, wicket gate & elevation grills including cost of all materials, labour charges for cutting, welding including one coat of epoxy primer etc., all complete. (The design of grill will be given by departmentally)
Supplying and painting the new walls with two coats weather shield exterior emulsion paint as instructed by the departmental Officers inluding preperation of surface, curing etc., all complete in all floors complying with standard specification. (The colour and shade of the paint shall be got approved by the departmental Officers)
Painting the new Iron works such as steel doors, windows, ventilators, window bars, balustrades etc.,in all floor with two coats of synthetic enamel paint of approved quality ( Colour and brand to be got approved by the Executive Engineer before use on works) over the existing red oxide primer coat in all floors excluding cost of priming coat etc., complete complying with standard specification. ( The make, quality and colour of paint should be got approved by the Engineer-in-charge before use on works)
Providing soak pit for the collection of waste water as 1.50 m dia and 3.00 m depth walls dry packed with randam rubble etc as per standard specification etc complete
Supply and run of 2 of 4 sqmm (56/0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable Pvc rigid pipe on wall and ceiling with contineous earth wire connection of 14 SWG TC wire painting of suitable colour (SD 56 PWD Electrical data)
Wiring with 2x1.5 sqmm(22/0.3) PVC insulated unsheathed SC copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC asscessories with TW switch box and 5A FT switch in flush with wall with 3 mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point/fanpoint(for electronic regulator) etc., complete as per standard specification (PWD Electrical data SD 24)
Supplying and fixing of fancy gate light fittings of good quality suitable for 20 w LED bulbs including cost of materials, labour charges for fixing etc., all complete and as directed by the departmental Officers
k manikandan (BID ID -1462966)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .