Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC | ₹4.5 Cr Quoted ₹4.3 Cr | L1 | Accepted-AOC Awarded |
| 2 | L1₹4.3 CrRejected-AOC BATASIPUR CITY TOWN DHEKIAJULI P O BATASIPUR P S DHEKIAJULI DIST SONITPUR PIN 784111 | SONITPUR | ASSAM | 784111 | ₹4.3 Cr | L1 | Rejected-AOC Rejected |
Tender Value
₹4.8 Cr
EMD Value
₹9.9 L
Closing Date
22 Dec 2022, 2:00 pmClosed
Chief Engineer, Roads, PWRD
O/o the Chief Engineer,(Roads)PWRD, Assam , Chandmari, Guwahati-781003
MMPPNA_22_23_425 Construction of road from (i) Mayla house to Kanda Daimary House via Kiran Boros House to Bhaskar Daimary House From Ch. 0.00 m to Ch. 2300.00 m, (ii) Sahebtopa Chowk to Baithaputa Namghar (From Ch. 0.00 m to Ch. 473.00 m),
2022_PWD_27897_425
CE/DEV/TB/235/2022-23/01
Open Tender
Civil Works
Item Rate
365 days
Tamulpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,910
₹9.9 L
Yes
Development Branch, O/o the CE (Roads)PWRD, Assam
24 May 2023
5 Dec 2022
23 Dec 2022
5 Dec 2022
22 Dec 2022
15 Dec 2022
5 Dec 2022 - 14 Dec 2022
14 Dec 2022
Amount
(i) Mayla's house to Kanda Daimary's House via Kiran Boros House to Bhaskar Daimary's House From Ch. 0.00 m to Ch. 2300.00 m Construction of Embankment with materials obtained from borrow pits, with a lift up to 1.5 m. transporting to site, speeding, grading to required slope and compacting to meet requirement of table 300.1 and 300.2 with a lead upto 1000 m. as per technical specification clause 301.5. (a) from private land
Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table 300.2 with lead upto 1000 m. as per technical specification clause 303.1 (a) from private land
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material (774-2x1.00 = 772.00 m)
WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means
Inter locking concrete Block pavement I)a Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 . A) Including Edge block/Edge restraints.
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 1) 600 cm equilateral tringle
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 600 mm Circular
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 80mm x 600 mm rectangular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specification and drawing. Three MS Plates of 1.6 mm thick,top and middle plate duly welded with MS flate iron 25mm x 5m size on back on edge. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. all sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1000 dia HP culvert : Earth work in excavation of foundation for structure as per drawing and technical specification Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and deleterious material and disposal upto a lead of 50m. dressing of sides and bottom and backfilling in trenches with excavated suitable material. 1. Ordinary soil (i) Upto 3 m depth
PCC 1:3:6 in Foundation Plain reinforced concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing & Technical Specification Clause 1109.
Providing and Laying RCC NP3 in Single Row Providing and laying reinforcement cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement morter 1:2 but excluding excavation, protection works, backfilling, coccrete and masonary works in head walls and parapets Clause 1106. (B) 1000 mm dia
Brick Masonary work Brick masonary work in cement morter in foundation of Head Wall excluding pointing and plastering as per drawing and technical specifications clause 1109. I)Brick masonary in 1:3 Cement mortar
Brick Masonary work Brick masonary work in cement morter in substructure complete excluding pointing and plastering as per drawing and technical specifications clause 602, 603, 604, 1202 and 1204.. I)Brick masonary in 1:3 Cement mortar
Plstering Plastering with cement mortar ( 1:4 ) 15mm thick on brick work in substructure as per technical specification Rate.
1.50 m Span Slab: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. I. P.C.C grade M 10 Nominal mix 1:3:6
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. III. P.C.C grade M 20 Nominal mix 1:2:4
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 A. With crushed stone I. R.C.C grade M 20 (I) For nominal mix 1:2:4 a} Height upto 5 M
Drainage spouts complete as per drawing and technical specifications Clause 1209
Filler Joint Iv} Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A. With crushed stone
Shifting of utilities as per site requirement in consultation with the concerning department
(ii) Sahebtopa Chowk to Baithaputa Namghar (From Ch. 0.00 m to Ch. 473.00 m) Construction of Embankment with materials obtained from borrow pits, with a lift up to 1.5 m. transporting to site, speeding, grading to required slope and compacting to meet requirement of table 300.1 and 300.2 with a lead upto 1000 m. as per technical specification clause 301.5. (a) from private land
Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table 300.2 with lead upto 1000 m. as per technical specification clause 303.1 (a) from private land
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material (774-2x1.00 = 772.00 m)
WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means
Inter locking concrete Block pavement I)a Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 . A) Including Edge block/Edge restraints.
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 1) 600 cm equilateral tringle
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 80mm x 600 mm rectangular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specification and drawing. Three MS Plates of 1.6 mm thick,top and middle plate duly welded with MS flate iron 25mm x 5m size on back on edge. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. all sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. b) Cement Concrete
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. (c) Reinforced Cement Concrete) Cement Concrete
1.50 m Span Slab: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. I. P.C.C grade M 10 Nominal mix 1:3:6
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. III. P.C.C grade M 20 Nominal mix 1:2:4
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 A. With crushed stone I. R.C.C grade M 20 (I) For nominal mix 1:2:4 a} Height upto 5 M
Drainage spouts complete as per drawing and technical specifications Clause 1209
Filler Joint Iv} Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A. With crushed stone
Shifting of utilities as per site requirement in consultation with the concerning department
(iii) Muri Chowk to Simolubari Village road From Ch. 0.00 m to Ch. 1000.00 m Construction of Embankment with materials obtained from borrow pits, with a lift up to 1.5 m. transporting to site, speeding, grading to required slope and compacting to meet requirement of table 300.1 and 300.2 with a lead upto 1000 m. as per technical specification clause 301.5. (a) from private land
Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table 300.2 with lead upto 1000 m. as per technical specification clause 303.1 (a) from private land
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material (774-2x1.00 = 772.00 m)
WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means
Inter locking concrete Block pavement I)a Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 . A) Including Edge block/Edge restraints.
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 1) 600 cm equilateral tringle
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 600 mm Circular
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 80mm x 600 mm rectangular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specification and drawing. Three MS Plates of 1.6 mm thick,top and middle plate duly welded with MS flate iron 25mm x 5m size on back on edge. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. all sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Single bamboo spur and palasiding of whole 2nd class bamboo (Jati or Bethua) 65mm to 75mm dia closely packed & driven, including fitting and fixing with half bamboo kamis horizantally in three rows with the cane or tieing wire complete and struts 1500 mm apart longitudinally and providing brush wood as per drawing and technical specification clause 1302.5 of MORD a) Driven at least 900mm below and 1800 mm above the ground on average. (From Ch. 625.00 m to Ch. 670.00 m on both side)
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. I By Manual Means (b) Cement Concrete
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. I By Manual Means (c) Reinforced Cement Concrete
1000 Dia HP Culvert : Earth work in excavation of foundation for structure as per drawing and technical specification Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and deleterious material and disposal upto a lead of 50m. dressing of sides and bottom and backfilling in trenches with excavated suitable material. 1. Ordinary soil (i) Upto 3 m depth
PCC 1:3:6 in Foundation Plain reinforced concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing & Technical Specification Clause 1109.
Providing and Laying RCC NP3 in Single Row Providing and laying reinforcement cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement morter 1:2 but excluding excavation, protection works, backfilling, coccrete and masonary works in head walls and parapets Clause 1106. (B) 1000 mm dia
Brick Masonary work Brick masonary work in cement morter in foundation of Head Wall excluding pointing and plastering as per drawing and technical specifications clause 1109. I)Brick masonary in 1:3 Cement mortar
Brick Masonary work Brick masonary work in cement morter in substructure complete excluding pointing and plastering as per drawing and technical specifications clause 602, 603, 604, 1202 and 1204.. I)Brick masonary in 1:3 Cement mortar
Plstering Plastering with cement mortar ( 1:4 ) 15mm thick on brick work in substructure as per technical specification Rate.
1.50 m Span Slab : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. I. P.C.C grade M 10 Nominal mix 1:3:6
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. III. P.C.C grade M 20 Nominal mix 1:2:4
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 A. With crushed stone I. R.C.C grade M 20 (I) For nominal mix 1:2:4 a} Height upto 5 M
Drainage spouts complete as per drawing and technical specifications Clause 1209
Filler Joint Iv} Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A. With crushed stone
Shifting of utilities as per site requirement in consultation with the concerning department
(iv) Bhangbari to Fahurabari Road (Bganbar to Fahurabari Chowk) From Ch. 0.00 m to Ch. 1000.00 m Construction of Embankment with materials obtained from borrow pits, with a lift up to 1.5 m. transporting to site, speeding, grading to required slope and compacting to meet requirement of table 300.1 and 300.2 with a lead upto 1000 m. as per technical specification clause 301.5. (a) from private land
Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table 300.2 with lead upto 1000 m. as per technical specification clause 303.1 (a) from private land
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material (774-2x1.00 = 772.00 m)
WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means
Inter locking concrete Block pavement I)a Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 . A) Including Edge block/Edge restraints.
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 1) 600 cm equilateral tringle
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 600 mm Circular
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 80mm x 600 mm rectangular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specification and drawing. Three MS Plates of 1.6 mm thick,top and middle plate duly welded with MS flate iron 25mm x 5m size on back on edge. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. all sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 I Random rubble masonry in case of stone pitching laid with cement mortar (1:5)
1000 Dia HP Culvert : Earth work in excavation of foundation for structure as per drawing and technical specification Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and deleterious material and disposal upto a lead of 50m. dressing of sides and bottom and backfilling in trenches with excavated suitable material. 1. Ordinary soil (i) Upto 3 m depth
PCC 1:3:6 in Foundation Plain reinforced concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing & Technical Specification Clause 1109.
Providing and Laying RCC NP3 in Single Row Providing and laying reinforcement cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement morter 1:2 but excluding excavation, protection works, backfilling, coccrete and masonary works in head walls and parapets Clause 1106. (B) 1000 mm dia
Brick Masonary work Brick masonary work in cement morter in foundation of Head Wall excluding pointing and plastering as per drawing and technical specifications clause 1109. I)Brick masonary in 1:3 Cement mortar
Brick Masonary work Brick masonary work in cement morter in substructure complete excluding pointing and plastering as per drawing and technical specifications clause 602, 603, 604, 1202 and 1204.. I)Brick masonary in 1:3 Cement mortar
Plstering Plastering with cement mortar ( 1:4 ) 15mm thick on brick work in substructure as per technical specification Rate.
Shifting of utilities as per site requirement in consultation with the concerning department
(v) Mukesh Kharka's House to Gaidang Chowk No.1 Kalipur From Ch. 0.00 m to Ch. 1000.00 m Construction of Embankment with materials obtained from borrow pits, with a lift up to 1.5 m. transporting to site, speeding, grading to required slope and compacting to meet requirement of table 300.1 and 300.2 with a lead upto 1000 m. as per technical specification clause 301.5. (a) from private land
Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table 300.2 with lead upto 1000 m. as per technical specification clause 303.1 (a) from private land
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material (774-2x1.00 = 772.00 m)
WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means
Inter locking concrete Block pavement Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 . A) Including Edge block/Edge restraints.
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 1) 600 cm equilateral tringle
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 600 mm Circular
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 80mm x 600 mm rectangular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specification and drawing. Three MS Plates of 1.6 mm thick,top and middle plate duly welded with MS flate iron 25mm x 5m size on back on edge. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. all sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1.50 m Span Slab: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. I. P.C.C grade M 10 Nominal mix 1:3:6
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. III. P.C.C grade M 20 Nominal mix 1:2:4
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 A. With crushed stone I. R.C.C grade M 20 (I) For nominal mix 1:2:4 a} Height upto 5 M
Drainage spouts complete as per drawing and technical specifications Clause 1209
Filler Joint Iv} Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A. With crushed stone
Shifting of utilities as per site requirement in consultation with the concerning department
GEREMCHA BASUMATARY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .