Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | ₹5.2 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹5.3 L+₹9,621 (1.86%)Rejected-Finance | ₹5.3 L+₹9,621 (1.86%) | L2 | Rejected-Finance Higher rate to the contractor |
| 3 | L3₹5.7 L+₹57,451 (11.1%)Rejected-Finance | ₹5.7 L+₹57,451 (11.1%) | L3 | Rejected-Finance Higher rate to the contractor |
Tender Value
₹4.9 L
EMD Value
₹9,800
Closing Date
20 Oct 2022, 5:00 pmClosed
Executive Engineer (OS)
Estate Office, CCS HAU, Hisar
Repair/maintenance of Main KVK Building at Rohtak (i.e. providing false ceiling, wall paneling etc.)
2022_HRY_240104_1
3314-C
Open Tender
Civil Works
Works
60 days
CCS HAU
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
₹9,800
Yes
24 Feb 2023
19 Sept 2022
21 Oct 2022
19 Sept 2022
20 Oct 2022
19 Sept 2022
Amount
Civil work 1 to 3:- Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge gypsum moisture resistant board (HSR 9.46.3)
Providing and Fixing 15 mm thick densifled tegular edged eco friendly light weight calcium silicate false celling tiles of approved texlure of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densifled edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixlures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ·r, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. (HSR 9.48) Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, noncombustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK.
Providing and fixing PVC wall paneling consisting of 7mm thick cactus make hollow PVC section, PVC U section beading of size 25 mm x 8 mm x 12 mm and PVC angle nosing of size 25 mm x 25 mm x 1.5 mm including cost of PVC gatties, screws, jointed with polyfix (instant glue), complete in all respect as per drawing or as directed by Engineer-in-charge. (NS)
EI work 4 to 35:- COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1)
MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. (HSR 23.6.6.1)
MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. (HSR 23.6.6.2)
PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of PVC conduit pipe ISI marked(Medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC Pipe of 20 mm dia. (HSR 23.7.6.1)
PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of PVC conduit pipe ISI marked(Medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2)
FITTING AND ACCESSORIES Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules (HSR 23.8.10.1)
FITTING AND ACCESSORIES Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules (HSR 23.8.10.4)
FITTING AND ACCESSORIES Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 8 Modules (HSR 23.8.10.5)
FITTING AND ACCESSORIES Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.12 Modules (HSR 23.8.10.6)
FITTING AND ACCESSORIES Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (HSR 23.8.11.1)
FITTING AND ACCESSORIES Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch (HSR 23.8.11.3)
FITTING AND ACCESSORIES Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket (HSR 23.8.11.4)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket (HSR 23.8.11.5)
FITTING AND ACCESSORIES Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 23.8.11.7) step type Fan Regulator 2 modules 300 watt
FITTING AND ACCESSORIES Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10)
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- SP MCB 6-32 AMP (HSR 23.22.5.1)
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- SPN MCB 6-32 AMP (HSR 23.22.5.3)
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- TPN MCB 40-63 AMP (HSR 23.22.5.6)
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. S/E of blanking sheet in existing distribution board. (HSR 23.22.7)
DIMANTLING Dismantling of old wiring points (surface wiring system) including necessary repairs to wall etc. Light, fan or call bell Point in cluding circuit /sub main wiring (HSR 23.25.1.1)
DIMANTLING Dismantling of old wiring points (surface wiring system) including necessary repairs to wall etc. wall socket Point in cluding circuit / submain wiring (HSR 23.25.1.2)
EARTHING AND LIGHTING ARRESTOR Earthing with G.I earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. as required. (HSR 24.1.1)
EARTHING AND LIGHTING ARRESTOR Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2)
EARTHING AND LIGHTING ARRESTOR Providing and laying earth connections from earth electrode with 4.00mm dia G.I. wire in 15mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)
EARTHING AND LIGHTING ARRESTOR Providing and fixing 4.00mm dia G1.Wire on surface or in recess for loop earthing as required. (HSR 24.1.13)
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm. (NS)
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. Size 04 sqmm. (NS)
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod etc. (NS) i) 1400mm sweep. Make: Usha, Orient, Crompton
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod etc. (NS) i) 1400mm sweep. Make: Usha, Orient, Crompton
S.I.T.C of push ON/OFF type 25 A Modular type motor starter swithch ( white color) fr AC'S including the cost of petty meterial required to complete the job upto entire satisfaction of Engineer-in Charge. (NS)
Supplying, installation, testing & Commissioning of recessed type 42w Full window glare free opal Diffuser LED Panel of size 595X595mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 42W LED should be 5100 lumen or above in Cool day Light(5600K to 6500K), Power factor>0.95, CRI>70, Average life: ≥50000 hours. Complete with all accessories as required with connections. (Philips, Havells and GE ) (NS)
SITC of 20W LED Tube light Batten ,Surface mounted light fixture, complete with all accessories internally prewired and including connecting up with flexible copper conductor wire with suitable size. Total system Lumen of 20W LED should be >2000Lm or above in Cool day Light(5700K to 6500K), Power factor>0.95, 100 lumen per watt or above, CRI>80, Average life: ≥50000 hours. Make Havells Philips, Wipro (NS)
Vikas Kumar, Contractor
Indora Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .