Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.0 L+₹48,336 (5.09%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-Finance Not being for Lowest | |
| 3 | L3₹10.0 L+₹50,283 (5.30%)Rejected-Finance 464 SHIVAJI MARG RAJROOPPUR ALLAHABAD UTTAR PRADESH 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Not being for Lowest | |
| 4 | L4₹10.5 L+₹1.1 L (11.1%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L4 | Rejected-Finance Not being for Lowest | |
| 5 | L5₹10.7 L+₹1.2 L (12.3%)Rejected-Finance | L5 | Rejected-Finance Not being for Lowest |
| Sl No | Description | Qty | Unit | Bharat Trading Company L1 | chauhan construction L6 | M/S Amar Enterprises L7 | M/S ANKIT ENTERPRISES L5 | Mohit Enterprises L2 | RK Enterprises L4 | R K GUPTA AND SONS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for preventive maintenance of fire alarm system complete Addressable type at 24 ED technical area having smoke, heat, multi detector, flame detector, Addressable module, manual call point, addressable electronic sounder cum strobe, short circuit isolator, electronic siren, PA system complete with monthly checkup of entire system and unliimited breakdown calls complete all as specified & directed.
NOTE:-
(i) Testing of fire alarm system as per relevant IS in the presence of the user and Engr-in-Charge is deemed to be included in the quoted rate.
(ii) The spare parts required to be replaced will be measured and paid seperately.
(iii) The unserviceability issued of fire alarm system shall be attended with in 24 hours failing which a sum of Rs 1000/- per day shall be recoverd from the contractor.
(iv) The preventive maintenance of fire alarm system under this contract shall be done through rep of OEM only.
(v) The contractor shall carry out routine checking of the complete fire alarm system and rectify the minor/major defect noticed during checking immidiately. Cleaning of detector once in a month and making the maintenance register for above maintenance and one separate register to be maintained by the contractor. The register will be signed by Engr-in-Charge / JE (E/M) and user rep after rectifying the defect.
(vii) One job per month will be measured and paid for each location/bldg. | 60 | Each Job Per Month | 5,200 ₹3,12,000 | 6,050 ₹3,63,000 | 6,500 ₹3,90,000 | 6,050 ₹3,63,000 | 5,420 ₹3,25,200 | 6,000 ₹3,60,000 | 5,000 ₹3,00,000 Lowest |
| 2.00 | Taking down old unserviceable Switch power supply (SMPC) of Control Panel make Honeywell Morleyor as per sample and supply and fixing Switch power supply (SMPC) input 100-240 V out put 24 V, 1.3 to 2 Amp, operating temprature -10 degree to + 50 degree C, closed housing with protection against mains AC, short circuit protection in-built filter against EMC interference complete all as specified & directed. | 2 | Each | 11,800 ₹23,600 | 11,190 ₹22,380 | 11,000 ₹22,000 | 11,000 ₹22,000 | 11,150 ₹22,300 | 10,500 ₹21,000 Lowest | 11,050 ₹22,100 |
| 3.00 | Taking down old unserviceable detector base and supply and fixing analogue Addressable detector base advanced protocol and smoothing filter to suppress false alarm maintain loop connectivity complete all as specified & directed. | 25 | Each | 140 ₹3,500 Lowest | 253 ₹6,325 | 350 ₹8,750 | 250 ₹6,250 | 265 ₹6,625 | 225 ₹5,625 | 250 ₹6,250 |
| 4.00 | Taking down old unserviceable Heat detector and Supply, Installation, testing and commissioning addressbale sensor type certified to EN 54 part 1, 58 degree addressable type microprocessor based, programable inteligent type, blue light opticle thermal heat detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed. | 15 | Each | 2,300 ₹34,500 Lowest | 2,699 ₹40,485 | 3,000 ₹45,000 | 2,680 ₹40,200 | 2,550 ₹38,250 | 2,650 ₹39,750 | 2,700 ₹40,500 |
| 5.00 | Supply, Installation, testing and commissioning in replacement addressable sensor type certified to EN 45 addressable type microprocessor based, programmable intelligent type, blue light optical smoke detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, conforms to EN 54-7, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed. | 15 | Each | 2,040 ₹30,600 Lowest | 2,209 ₹33,135 | 2,900 ₹43,500 | 2,260 ₹33,900 | 2,150 ₹32,250 | 2,500 ₹37,500 | 2,270 ₹34,050 |
| 6.00 | Supply, Installation, testing and commissioning in replacement addressbale intelligence having inbuilt microprocessor, memory and decision alogrithm twin angle with both forward and backward light scattering mechanism cum thermal multicriteria detector (sensor) with heat and smoke combination (multi detector) confirms EN54-5 & FN 54-7 LPCB approved complete all as specified & directed. | 30 | Each | 2,475 ₹74,250 | 2,799 ₹83,970 | 2,800 ₹84,000 | 2,690 ₹80,700 | 2,350 ₹70,500 Lowest | 2,700 ₹81,000 | 2,700 ₹81,000 |
| 7.00 | S&F in replacement maintenance free battery of capacity 12 Volt 7 AH, VRLA AGM type including standard spade terminals connecting and testing at site complete with one year warranty including taking down old unsv battery complete all as specified & directed. | 10 | Each | 2,625 ₹26,250 Lowest | 2,989 ₹29,890 | 2,900 ₹29,000 | 2,775 ₹27,750 | 2,750 ₹27,500 | 2,750 ₹27,500 | 2,795 ₹27,950 |
| 8.00 | Taking down old unsv PCB of main Control panel of fire alarm and supply and fixing of new PCB of existing make complete all as specified & directed. | 2 | Each | 17,800 ₹35,600 | 18,670 ₹37,340 | 20,000 ₹40,000 | 17,500 ₹35,000 | 16,500 ₹33,000 Lowest | 17,400 ₹34,800 | 17,510 ₹35,020 |
| 9.00 | S&F in replacement ONLINE UPS 1 KVA (1000 VA) 6 Volt pure sinewave without in-Built batteries,40-50 Min backup, inbuilt OVCD (over voltage Cut off Device) with surge protection, efficient micro controller based, advanced PFC technology, static bypass-improves reliability, over temprature indication and protection, generator compatible, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including wall mounted stand for UPS suitable sizecomplete all as specified & directed.
Note: Old unserviceable UPS should be deposited to MES Store yard. | 2 | Each | 24,500 ₹49,000 | 26,540 ₹53,080 | 28,000 ₹56,000 | 26,000 ₹52,000 | 22,500 ₹45,000 Lowest | 25,500 ₹51,000 | 25,000 ₹50,000 |
| 10.00 | M&L in replacement sub main wiring with two run of single core PVC FRLS IS-694 cable with multi stranded copper conductor of size 1.50 Sqmm and drawing through in PVC medium grade heavy duty conduit pipe on surafce of wall with using 1.50 Sqmm PVC insulated unsheathed multi stranded copper conductor cable connected to earth and earth dolly in conduit including conecting to main board including PVC conduit heavy duty minimum 20 mm dia size complete all as specified & directed.
NOTE : (i) One run of conduit with three run of copper cable in equal size shall be measured against one unit. | 150 | RM | 160 ₹24,000 Lowest | 219 ₹32,850 | 200 ₹30,000 | 200 ₹30,000 | 215 ₹32,250 | 190 ₹28,500 | 205 ₹30,750 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
25 May 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF Manauri
AGE (I) AF Manauri
REPAIR/MAINT OF SMOKE DETECTOR AND FLAME DETECTOR INFRASTRUCTURE WITH OTHER CONNECTED WORKS AT 24 ED
2026_MES_763380_1
8000/22/E8
Open Tender
Civil Works
Item Rate
335 days
Manauri Prayagraj
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF MANAURI
₹19,800
Yes
14 Nov 2026
4 May 2026
27 May 2026
4 May 2026
25 May 2026
18 May 2026
4 May 2026 - 13 May 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for preventive maintenance of fire alarm system complete Addressable type at 24 ED technical area having smoke, heat, multi detector, flame detector, Addressable module, manual call point, addressable electronic sounder cum strobe, short circuit isolator, electronic siren, PA system complete with monthly checkup of entire system and unliimited breakdown calls complete all as specified & directed.
NOTE:-
(i) Testing of fire alarm system as per relevant IS in the presence of the user and Engr-in-Charge is deemed to be included in the quoted rate.
(ii) The spare parts required to be replaced will be measured and paid seperately.
(iii) The unserviceability issued of fire alarm system shall be attended with in 24 hours failing which a sum of Rs 1000/- per day shall be recoverd from the contractor.
(iv) The preventive maintenance of fire alarm system under this contract shall be done through rep of OEM only.
(v) The contractor shall carry out routine checking of the complete fire alarm system and rectify the minor/major defect noticed during checking immidiately. Cleaning of detector once in a month and making the maintenance register for above maintenance and one separate register to be maintained by the contractor. The register will be signed by Engr-in-Charge / JE (E/M) and user rep after rectifying the defect.
(vii) One job per month will be measured and paid for each location/bldg. | 60 | Each Job Per Month | - | - |
| 2 | Taking down old unserviceable Switch power supply (SMPC) of Control Panel make Honeywell Morleyor as per sample and supply and fixing Switch power supply (SMPC) input 100-240 V out put 24 V, 1.3 to 2 Amp, operating temprature -10 degree to + 50 degree C, closed housing with protection against mains AC, short circuit protection in-built filter against EMC interference complete all as specified & directed. | 2 | Each | - | - |
| 3 | Taking down old unserviceable detector base and supply and fixing analogue Addressable detector base advanced protocol and smoothing filter to suppress false alarm maintain loop connectivity complete all as specified & directed. | 25 | Each | - | - |
| 4 | Taking down old unserviceable Heat detector and Supply, Installation, testing and commissioning addressbale sensor type certified to EN 54 part 1, 58 degree addressable type microprocessor based, programable inteligent type, blue light opticle thermal heat detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed. | 15 | Each | - | - |
| 5 | Supply, Installation, testing and commissioning in replacement addressable sensor type certified to EN 45 addressable type microprocessor based, programmable intelligent type, blue light optical smoke detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, conforms to EN 54-7, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed. | 15 | Each | - | - |
| 6 | Supply, Installation, testing and commissioning in replacement addressbale intelligence having inbuilt microprocessor, memory and decision alogrithm twin angle with both forward and backward light scattering mechanism cum thermal multicriteria detector (sensor) with heat and smoke combination (multi detector) confirms EN54-5 & FN 54-7 LPCB approved complete all as specified & directed. | 30 | Each | - | - |
| 7 | S&F in replacement maintenance free battery of capacity 12 Volt 7 AH, VRLA AGM type including standard spade terminals connecting and testing at site complete with one year warranty including taking down old unsv battery complete all as specified & directed. | 10 | Each | - | - |
| 8 | Taking down old unsv PCB of main Control panel of fire alarm and supply and fixing of new PCB of existing make complete all as specified & directed. | 2 | Each | - | - |
| 9 | S&F in replacement ONLINE UPS 1 KVA (1000 VA) 6 Volt pure sinewave without in-Built batteries,40-50 Min backup, inbuilt OVCD (over voltage Cut off Device) with surge protection, efficient micro controller based, advanced PFC technology, static bypass-improves reliability, over temprature indication and protection, generator compatible, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including wall mounted stand for UPS suitable sizecomplete all as specified & directed.
Note: Old unserviceable UPS should be deposited to MES Store yard. | 2 | Each | - | - |
| 10 | M&L in replacement sub main wiring with two run of single core PVC FRLS IS-694 cable with multi stranded copper conductor of size 1.50 Sqmm and drawing through in PVC medium grade heavy duty conduit pipe on surafce of wall with using 1.50 Sqmm PVC insulated unsheathed multi stranded copper conductor cable connected to earth and earth dolly in conduit including conecting to main board including PVC conduit heavy duty minimum 20 mm dia size complete all as specified & directed.
NOTE : (i) One run of conduit with three run of copper cable in equal size shall be measured against one unit. | 150 | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
Tender22.pdf
Tender Documents • 1.39 MB
LISTOFMAKE22.pdf
Additional Documents • 0.96 MB
BOQ_855076.xls
BOQ • 0.33 MB
Amendment22.pdf
PDF • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .