| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAdmitted-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | SANT KABEER NAGAR | UTTAR PRADESH | 272125 | ₹9.5 L | L1 | Admitted-Finance |
| 2 | L2₹10.0 LAdmitted-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹10.0 L | L2 | Admitted-Finance |
| 3 | L3₹10.0 LAdmitted-Finance 464 SHIVAJI MARG RAJROOPPUR ALLAHABAD UTTAR PRADESH 211011 UDYAM UP 03 0022460 | PRAYAGRAJ | UTTAR PRADESH | 211011 | ₹10.0 L | L3 | Admitted-Finance |
| 4 | L4₹10.5 LAdmitted-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | ₹10.5 L | L4 | Admitted-Finance |
| 5 | L5₹10.7 LAdmitted-Finance | ₹10.7 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bharat Trading Company L1 | chauhan construction L6 | M/S Amar Enterprises L7 | M/S ANKIT ENTERPRISES L5 | Mohit Enterprises L2 | RK Enterprises L4 | R K GUPTA AND SONS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for preventive maintenance of fire alarm system complete Addressable type at 24 ED technical area having smoke, heat, multi detector, flame detector, Addressable module, manual call point, addressable electronic sounder cum strobe, short circuit isolator, electronic siren, PA system complete with monthly checkup of entire system and unliimited breakdown calls complete all as specified & directed.
NOTE:-
(i) Testing of fire alarm system as per relevant IS in the presence of the user and Engr-in-Charge is deemed to be included in the quoted rate.
(ii) The spare parts required to be replaced will be measured and paid seperately.
(iii) The unserviceability issued of fire alarm system shall be attended with in 24 hours failing which a sum of Rs 1000/- per day shall be recoverd from the contractor.
(iv) The preventive maintenance of fire alarm system under this contract shall be done through rep of OEM only.
(v) The contractor shall carry out routine checking of the complete fire alarm system and rectify the minor/major defect noticed during checking immidiately. Cleaning of detector once in a month and making the maintenance register for above maintenance and one separate register to be maintained by the contractor. The register will be signed by Engr-in-Charge / JE (E/M) and user rep after rectifying the defect.
(vii) One job per month will be measured and paid for each location/bldg. | 60 | Each Job Per Month | 5,200 ₹3.1 L | 6,050 ₹3.6 L | 6,500 ₹3.9 L | 6,050 ₹3.6 L | 5,420 ₹3.3 L | 6,000 ₹3.6 L | 5,000 ₹3 L |
| 2.00 | Taking down old unserviceable Switch power supply (SMPC) of Control Panel make Honeywell Morleyor as per sample and supply and fixing Switch power supply (SMPC) input 100-240 V out put 24 V, 1.3 to 2 Amp, operating temprature -10 degree to + 50 degree C, closed housing with protection against mains AC, short circuit protection in-built filter against EMC interference complete all as specified & directed. | 2 | Each | 11,800 ₹23,600 | 11,190 ₹22,380 | 11,000 ₹22,000 | 11,000 ₹22,000 | 11,150 ₹22,300 | 10,500 ₹21,000 | 11,050 ₹22,100 |
| 3.00 | Taking down old unserviceable detector base and supply and fixing analogue Addressable detector base advanced protocol and smoothing filter to suppress false alarm maintain loop connectivity complete all as specified & directed. | 25 | Each | 140 ₹3,500 | 253 ₹6,325 | 350 ₹8,750 | 250 ₹6,250 | 265 ₹6,625 | 225 ₹5,625 | 250 ₹6,250 |
| 4.00 | Taking down old unserviceable Heat detector and Supply, Installation, testing and commissioning addressbale sensor type certified to EN 54 part 1, 58 degree addressable type microprocessor based, programable inteligent type, blue light opticle thermal heat detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed. | 15 | Each | 2,300 ₹34,500 | 2,699 ₹40,485 | 3,000 ₹45,000 | 2,680 ₹40,200 | 2,550 ₹38,250 | 2,650 ₹39,750 | 2,700 ₹40,500 |
| 5.00 | Supply, Installation, testing and commissioning in replacement addressable sensor type certified to EN 45 addressable type microprocessor based, programmable intelligent type, blue light optical smoke detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, conforms to EN 54-7, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed. | 15 | Each | 2,040 ₹30,600 | 2,209 ₹33,135 | 2,900 ₹43,500 | 2,260 ₹33,900 | 2,150 ₹32,250 | 2,500 ₹37,500 | 2,270 ₹34,050 |
| 6.00 | Supply, Installation, testing and commissioning in replacement addressbale intelligence having inbuilt microprocessor, memory and decision alogrithm twin angle with both forward and backward light scattering mechanism cum thermal multicriteria detector (sensor) with heat and smoke combination (multi detector) confirms EN54-5 & FN 54-7 LPCB approved complete all as specified & directed. | 30 | Each | 2,475 ₹74,250 | 2,799 ₹83,970 | 2,800 ₹84,000 | 2,690 ₹80,700 | 2,350 ₹70,500 | 2,700 ₹81,000 | 2,700 ₹81,000 |
| 7.00 | S&F in replacement maintenance free battery of capacity 12 Volt 7 AH, VRLA AGM type including standard spade terminals connecting and testing at site complete with one year warranty including taking down old unsv battery complete all as specified & directed. | 10 | Each | 2,625 ₹26,250 | 2,989 ₹29,890 | 2,900 ₹29,000 | 2,775 ₹27,750 | 2,750 ₹27,500 | 2,750 ₹27,500 | 2,795 ₹27,950 |
| 8.00 | Taking down old unsv PCB of main Control panel of fire alarm and supply and fixing of new PCB of existing make complete all as specified & directed. | 2 | Each | 17,800 ₹35,600 | 18,670 ₹37,340 | 20,000 ₹40,000 | 17,500 ₹35,000 | 16,500 ₹33,000 | 17,400 ₹34,800 | 17,510 ₹35,020 |
| 9.00 | S&F in replacement ONLINE UPS 1 KVA (1000 VA) 6 Volt pure sinewave without in-Built batteries,40-50 Min backup, inbuilt OVCD (over voltage Cut off Device) with surge protection, efficient micro controller based, advanced PFC technology, static bypass-improves reliability, over temprature indication and protection, generator compatible, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including wall mounted stand for UPS suitable sizecomplete all as specified & directed.
Note: Old unserviceable UPS should be deposited to MES Store yard. | 2 | Each | 24,500 ₹49,000 | 26,540 ₹53,080 | 28,000 ₹56,000 | 26,000 ₹52,000 | 22,500 ₹45,000 | 25,500 ₹51,000 | 25,000 ₹50,000 |
| 10.00 | M&L in replacement sub main wiring with two run of single core PVC FRLS IS-694 cable with multi stranded copper conductor of size 1.50 Sqmm and drawing through in PVC medium grade heavy duty conduit pipe on surafce of wall with using 1.50 Sqmm PVC insulated unsheathed multi stranded copper conductor cable connected to earth and earth dolly in conduit including conecting to main board including PVC conduit heavy duty minimum 20 mm dia size complete all as specified & directed.
NOTE : (i) One run of conduit with three run of copper cable in equal size shall be measured against one unit. | 150 | RM | 160 ₹24,000 | 219 ₹32,850 | 200 ₹30,000 | 200 ₹30,000 | 215 ₹32,250 | 190 ₹28,500 | 205 ₹30,750 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
25 May 2026, 6:00 pmClosed
AGE (I) AF Manauri
AGE (I) AF Manauri
REPAIR/MAINT OF SMOKE DETECTOR AND FLAME DETECTOR INFRASTRUCTURE WITH OTHER CONNECTED WORKS AT 24 ED
2026_MES_763380_1
8000/22/E8
Open Tender
Civil Works
335 days
Manauri Prayagraj
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF MANAURI
₹19,800
Yes
20 Jun 2026
4 May 2026
27 May 2026
4 May 2026
25 May 2026
18 May 2026
4 May 2026 - 13 May 2026
Taking down old unserviceable Switch power supply (SMPC) of Control Panel make Honeywell Morleyor as per sample and supply and fixing Switch power supply (SMPC) input 100-240 V out put 24 V, 1.3 to 2 Amp, operating temprature -10 degree to + 50 degree C, closed housing with protection against mains AC, short circuit protection in-built filter against EMC interference complete all as specified & directed.
Taking down old unserviceable detector base and supply and fixing analogue Addressable detector base advanced protocol and smoothing filter to suppress false alarm maintain loop connectivity complete all as specified & directed.
Taking down old unserviceable Heat detector and Supply, Installation, testing and commissioning addressbale sensor type certified to EN 54 part 1, 58 degree addressable type microprocessor based, programable inteligent type, blue light opticle thermal heat detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed.
Supply, Installation, testing and commissioning in replacement addressable sensor type certified to EN 45 addressable type microprocessor based, programmable intelligent type, blue light optical smoke detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, conforms to EN 54-7, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed.
Supply, Installation, testing and commissioning in replacement addressbale intelligence having inbuilt microprocessor, memory and decision alogrithm twin angle with both forward and backward light scattering mechanism cum thermal multicriteria detector (sensor) with heat and smoke combination (multi detector) confirms EN54-5 & FN 54-7 LPCB approved complete all as specified & directed.
S&F in replacement maintenance free battery of capacity 12 Volt 7 AH, VRLA AGM type including standard spade terminals connecting and testing at site complete with one year warranty including taking down old unsv battery complete all as specified & directed.
Taking down old unsv PCB of main Control panel of fire alarm and supply and fixing of new PCB of existing make complete all as specified & directed.
S&F in replacement ONLINE UPS 1 KVA (1000 VA) 6 Volt pure sinewave without in-Built batteries,40-50 Min backup, inbuilt OVCD (over voltage Cut off Device) with surge protection, efficient micro controller based, advanced PFC technology, static bypass-improves reliability, over temprature indication and protection, generator compatible, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including wall mounted stand for UPS suitable sizecomplete all as specified & directed. Note: Old unserviceable UPS should be deposited to MES Store yard.
M&L in replacement sub main wiring with two run of single core PVC FRLS IS-694 cable with multi stranded copper conductor of size 1.50 Sqmm and drawing through in PVC medium grade heavy duty conduit pipe on surafce of wall with using 1.50 Sqmm PVC insulated unsheathed multi stranded copper conductor cable connected to earth and earth dolly in conduit including conecting to main board including PVC conduit heavy duty minimum 20 mm dia size complete all as specified & directed. NOTE : (i) One run of conduit with three run of copper cable in equal size shall be measured against one unit.
Taking down any type of detector and clean properly with help of air blower and after cleaning fixed in existing position complete all as specified & directed. Note : T&P (ladder, Air blower, etc) shall be arranged by the Contractor under own cost and arrangement.
Supply, Installation, testing and commissioning in replacement floor/surface mounting addressable microprocessor fire alarm control main control panel single loop with BS EN 54 and indicating panel sounder circuits complete with LCD Display and push button to acknowledge alarm, testing and reset suitable for operation 230 volts single phase 50 Hzs AC supply 24 V DC supply with suitable capacity charger maintenance free batteries and battery charger,compatable with detector for communication to detectors and 2 x 16 character LCD, confirming to IS : 2189 and BSEN 54 of capacity from 99 detector and 99 module devices upto 200 detector single loop 6*4' character 2 sounder circuits PTR requires network card and modules (per each loop) etc including making all connection and fixing accessories complete all as specified & directed.
Supply, install, testing and commissioning in replacement conventional electronic speaker cum hooter with range of 25-30 meter with output not less than 4 watt including necessary connection complete all as specified & directed.
Taking down old unserviceable siren and supply and fixing Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured with sound output variation of +5 DB 500 mtrs range complete all as specified & directed.
S&F in replacement addressable control unit for siren complete all as specified & directed.
Supply and fix addressable type Manual Call point resettable type compatible with main fire alarm control board microprocessor based as per IS-2189 complete all as specified and directesd.
Taking down old unserviceable cable and Supply and laying for XLPE insulated PVC innersheathed, armoured, LT control cable FRLS multistranded copper conductor, 1100 volts grade, cross-sectional area 2.50 Sqmm 4 core as per IS 7098 (Part I) 1988 complete all as specified & directed.
S&F in replacement AFO (Auto fire off) plastic fire extinguisher ball (orange colour) it can self active in the presence of fire, active within 3 to 5 seconds upon reaching the appropriate temprature and extenguish the fire, maintenance free for period 5 years, completely harmless to the human body, area cover 360 degree angle, area of about 70 to 80 sqft, it can be extinguish three classes of fire, solid, Liquid and electrical classes of fire, weight 1.50 Kg, 100% eco friendly, 100% bio-degradable along with fixing on wall accessories complete all as specified & directed.
S&F in replacement Fire extinguisher spray foam type 500 ml aluminium body with stand, spray which contain chemical solution that works immediately on touch to keep small from growing dangerously out of control complete all as specified & directed.
S&F in replacement Eco fire ABC powder type 6 Kg fire extinguisher (red and black) effective for all type of fire with wall mount hook, ISI/ BIS marked, ISO & CE certified multipurpose use with 5 year warranty portable complete all as specified & directed. Make :-"Eco Fire / AMEREX / Kidde"
S&F in replacement Eco fire ABC powder type 9 Kg fire extinguisher (red and black) effective for all type of fire with wall mount hook, ISI/ BIS marked, ISO & CE certified multipurpose use with 5 year warranty portable complete all as specified & directed. Make :- "Eco Fire / AMEREX / Kidde"
Taking down old foam of fire extinguisher and refilling of ABC powder type, CO2 fire extinguisher, foam type fire in extinguisher cylinder complete all as specified & directed. (Note : Contractor shall be provide all safety equipment to the person which is refill the Cylinder)
Supply, Installation, testing and commissioning in repair Net work card for integration of fire alarm Panels to repeater panel into a net worked system complete as per existing fire alarm infrstrucure system for smooth operation/forformance complete all as directed by engr-in-charge.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
Tender22.pdf
Tender Documents • 1.39 MB
LISTOFMAKE22.pdf
Additional Documents • 0.96 MB
BOQ_855076.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid