Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹51.8 Cr
EMD Value
₹35 L
Closing Date
15 Dec 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
BHILAI STEEL PLANT
Construction of Main Employee Gate, Material Gate Complexes & Admin Building at Bhilai Steel Plant, Bhilai (Package No. EN-01C)
1785
PCC-NTK/E-006/26/04 Dated: 17/11/2026
OTE-INDG
Non Turnkey
Raipur, Chhattisgarh
• Technical Eligibility Criteria The bidder, as a Sole Bidder, shall fulfill the following Technical Eligibility Criteria for which documentary evidence shall be submitted by the bidder with their offer: A. Bidder should have Experience of having successfully completed similar projects during last 10 (Ten) years ending last day of the month previous to the one in which tender is invited should be either of the following: (i) At least Three completed projects comprising similar works defined below, having value of each of the three work orders not less than INR 13 Crores (Rs. Thirteen Crores ) without GST. OR (ii) At least Two completed projects comprising similar works defined below, having value of each of the two work orders not less than INR 18 Crores (Rs. Eighteen Crores) without GST. OR (iii) At least One completed projects comprising similar work defined below, having value of the work order not less than INR 22 Crores (Rs. Twenty Two Crores) without GST. B. Definition of Similar Works: “Civil works including Construction of RCC – framed structure building with a minimum of G+2 floors for industrial / infrastructure projects” C. Documents to be submitted by the Bidder for fulfilling Technical Eligibility Criteria The bidder, as a Sole Bidder, shall submit Scanned copy of original documents/Self-attested/ Digitally signed copies of the following documentary evidence, issued by client to the bidder, in proof of meeting the prescribed eligibility criteria with specific mention of information required as follows: i. Work Order(s)/Purchase Order(s)/ Contract Agreement(s)/ any other Letter of Award (LOA) of work in respect of Technical Eligibility Criteria by any Central/ State Govt. Organizations/ PSU/Public Limited Companies. ii. Preliminary Acceptance Certificate/ Commissioning Certificate/ Performance Certificate/ Completion certificate/ Final acceptance certificate/ any other documents (indicating executed value of job) issued by any Central/ State Govt. Organizations/ PSU/ Public Limited Companies. iii. In case of ongoing works, Bidder shall submit a document in original, issued by the concerned authority certifying value of completed similar works given in the Eligibility Criteria above against concerned Work Order(s)/Purchase Order(s)/ Contract Agreement(s)/ any other letter of award of work. Note: All work orders having similar work where completion date falls within 10 (Ten) years ending last day of the month previous to the one in which tenders are invited shall be considered for evaluation as per Eligibility criteria, irrespective of date of work order
• A) Financial Eligibility Criteria 1. Average annual financial turnover of the bidder shall not be less than INR 17.84 Crore (Indian Rupees Seventeen Crore Eighty Four Lakhs Only) consecutive financial years during 2023- 24, 2024-25 & 2025-26. 2. P&L statement should be in the name of participating tenderer. 3. The Bidder shall submit copy of Audited annual reports (financial statement) clearly evidencing the Annual Financial Turnover figure for 3 (three) consecutive financial years as mentioned herein above in support of their meeting above stipulated financial criterion. 4. Audited profit & loss account certified by the CA members, submitted by the party/tenderer in support of the turnover against the eligibility criteria shall contain the Unique Document Identification Number (UDIN) for the financial years mentioned above. 5. The net worth of the bidder should be positive in the financial year i.e. 2025-2026, as per the Audited annual accounts. 6. No Corporate Insolvency Resolution/Liquidation Process should have commenced in respect of the Bidder under National Company Law Tribunal (NCLT). A self-certification by the bidder as per Annexure-F shall be submitted. 7. In compliance to "Restriction under Rule 144 (xi) in the General Finance Rules (GFRs) 2017 of Govt. of India (regarding Country of Bidder sharing a land border with India), the Bidders shall submit undertaking in sl.no.09 of Appendix – 1. 8. Certificate/undertaking regarding guidelines in the prescribed format (Appendix-1 to Annexure-H). 9. Self-certification by the bidder as per Annexure -G. Consortium Bidding is not allowed for this package (Sole bidder only)
12 documents required · 12 mandatory
₹35 L
Yes
LINK WILL BE SHARED FOR VC
17 Nov 2026
17 Nov 2026
15 Dec 2026
17 Nov 2026
15 Dec 2026
17 Nov 2026
27 Nov 2026
Architectural Works
Civil Works
Supply of Plant & Equipment
Storage, Handling, Erection, Commissioning and Performance Guarantee Tests, Final Painting, etc.
Total Contract Price: (Sum of Sl.No. 1 to 4)
Input Tax Credit for GST
Contract Price (Net of Input Tax Credit) : (5 - 6)
Quoted percentage variation from total price indicated at Sl.No. 7 above
Above (+)/Below (-)/At par (0)
In Words………………………………...................……%
Total Quoted Price (Considering Percentage variation indicated above at Sl.No. 8 ) Above (+)/Below (-)/At par (0)
In Words…………………………………
Notes:
The bidder shall quote unique percentage in Above(+)/Below (-)/At par (0) at Sl.No. 8 on the above declared estimated total price at Sl.No.7.
Price evaluation will be based on the Total Quoted Price at Sl. No. 9.
In case of arithmetic error in totaling, corrected arithmetic total will be considered.
In case of discrepancy between words and figures and / or arithmetic error in totaling, corrected arithmetic total will be considered.
Remarks / Footnotes / Comments furnished in un-priced bids will prevail, if any discrepancy is found in furnishing any Remarks / Footnotes / Comments between un-priced bids and priced bids.
Signature of Authorised signatory
(Official Seal of Company)
Table -2
Name of the Plant/ Unit:
Package Name :
Package No.
PRICE SCHEDULE FOR ARCHITECTURAL WORKS ON ITEM RATE BASIS
Item No.
40 mm thick with 20 mm nominal size stone aggregate.
18 mm thick
25 mm thick
Double charge vitrified tile polished finish of size
size of tile 600x600 mm
size of tile 600x1200 mm
size of tile 600x1200 mm Matt/ Antiskid finish
Size of tile 600x600 mm
With single piece slab of approved size of any colour in color black/ Ruby red/ cherry/ Elite brown, Cat eye or equivalent
b) Same as above but with 8 mm thick polished granite slab in skirting, dado, staircase and other vertical surfaces with single piece slab size 300 mm x 150 mm
i) colour black/Rubby Red/cherry
a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mmx 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment up to 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.
b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.
c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology up to 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.
450 mm Finished Floor Height (FFH)
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand).
Acid and alkaly resistant tile
In Dado/ Skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand).
Acid and alkaly resistant tile
1:6 (1 cement : 6 fine sand)
1:6 (1 cement : 6 fine sand)
1:3 (1 cement : 3 fine sand)
New work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
two coats
two or more coats on new work
With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre.
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.
Two or more coats on new work.
Two or more coats on new works including a coat of wood filler.
two coats
Profile B
Fixing with adjustable lugs with split end tail to each jamb
35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):
Rectangular or square
1.5 mm thick
single rubber stopper
(a)Fixed to steel window by welding
b)Fixed to openings /wooden frames with rawl plugs screws etc.
Upto 5mm depth and 5 mm width
With float glass panes of 5.0 mm thickness
With float glass panes of 8 mm thickness
(a) For fixed portion
i. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
(b) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
i. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Particle Board 12 mm thick — Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
With stainless steel cover plate minimum 1.25 mm thickness
12.5 mm thick tapered edge gypsum moisture resistant board
With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles
With 15 mm thick tegular/butt edged without perforation plain/designer light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tiles Confirming to JIS-Z2801 and ASTM G-21
(ii) with semi perforated Gypsum board
(i) with cement bonded particle board conforming to IS:14276
(ii) with medium density fibre boards (MDF) conforming to IS:12406
110 mm diameter
160 mm diameter
Screened through sieve of IS designation 16 mm
Holes 90 cm dia, and 90 cm deep.
Holes 60 cm dia, and 60 cm deep.
Common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Trees Plant
Shrubs plant
Hedge Plant
b. Bauhinia purpurea (Kachnar) of plants height 150-165 cm. in big polybags of plants size 25 cm
c. Bottle palm of plants ht. 150-180 cm bottom girth 20-25 cm well devedoped in big poly bags of plants size 25 cm
d. Butea frondosa (Flame of plants Fores ikS/kkt) of plants height 60-75 cm. in big poly bags of plants size 25 cm
e. Callistemon lanceolatus of plants height 150-165 cm. in big poly bags of plants size 25 cm
f. Cassia fistula (Amaltash) of plants height 120-135 cm. in big poly bags of plants size 25 cm
g. Cassia siamea of plants height 150-165 cm. in big poly bags of plants size 25 cm
h. Delonix regia (Gulmohar) of plants height 150-165 cm. in big polybags of plants size 25 cm
i. Ficus elastica Decora (Rubber plant) of plants height 45-60 cm. In earthen pots of plants size 25 cm
k. Ingla dulcis (Jungle Jalebi) of plants height 150-165 cm. in big polybags of plants size 25 cm
m. Lagerstroemia flosreginae of plants height 150-165 cm.in big poly bag of plants size 25 cm
n. Plumeria acutifolia of plants height 120-135 cm. with 2-3 branches in HDPE bag of plants size 30 cm
p. Polyalthia longifolia (Ashok) of plants height 180-195 cm. in gunny bag of plants size 30 cm
q. Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan, Scarlet Queen, Varigata, Glabra Formosa, Peruviana Odissi, Partha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) plant of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots /Plastic pots.
r. Allamanda cathartica plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots
specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, asper the Architectural drawings, as per item description, asspecified, as per the approved shop drawings and as directedby the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainlesssteel wire mesh shall be paid for separately under
relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science &Technologies, India. Cost of testing is payable separately.The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing systemTests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
ii. Kitchen sink without drain board
610x510 mm bowl depth 200mm.
b) Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete
Flexible pipe
32 mm dia
c) Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45gms.
d) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
e) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
CP Brass
15 mm nominal bore
White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
b) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
c) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
W.C. pan with ISI marked white solid plastic seat and lid.
b) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
c) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
b. Providing and fixing PTMT urinal cock of approved quality and colour
15 mm nominal bore, 80 mm long, 42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms
c. Providing and fixing PTMT 15 mm urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 gms
a) Urinal Make: (Kohler Cat No: 5017IN-ER-0), Jaquar URS-WHT-132530) or similar approved equivalent make (Hindware - 96014)
b) Automatic flushing system for urinal Make: (Kohler 8791T-C01-CP), Jaquar SNR-CHR-51097) or similar approved equivalent make (Hindware - F860083)
c) Bottle trap Make: (Kohler Cat No: 7314IN-CP), (Jaquar ALD CHR-769L300X190) or similar approved equivalent make (Hindware - F850072)
White Vitreous China flat back Wash basin size 550x400 mm with single 15 mm C.P. brass pillar taps.
b) Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete
Flexible pipe
32 mm dia
c) Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45gms.
d) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
e) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers Isi marked
b) Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete
Flexible pipe
32 mm dia
c) Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45gms.
d) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
e) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
Granite of any colour and shade
Area of slab above 0.50 sqm
b. Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Granite work
c. Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. Complete
d) Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
15 mm nominal bore.
15 mm nominal bore.
600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms
b. Providing and fixing CP bras shower rose with 15 or 20 mm inlet
150 mm diameter
Flexible pipe
32 mm dia
40 mm dia
45 cm length
15 mm nominal bore
110 mm dia pipes with minimum wall thickness of 3.20mm.
75 mm dia pipes with minimum wall thickness of 3.20mm.
100 mm inlet and 100 mm outlet
100 mm inlet and 75 mm outlet
Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
25 mm nominal bore
32 mm nominal bore.
40 mm nominal bore
50 mm nominal bore
Circular tank
15 mm nominal bore
15 mm nominal bore
15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms.
i) 15 mm nominal bore, 107 mm long
Circular type
100 mm nominal dia
100 mm nominal dia with 25 mm waste hole
25 mm nominal bore
EWC (Make: Hindware Matrix, CERA Cruse, Jaquar DIS-WST-93951UF or similar approved equivalent make)
Health Faucet Make: (Kohler Cat No:12927IN-CP), (Jaquar ALD-CHR-577) or similar approved equivalent make (Hindware - F160110)
Bib cock Make: (Kohler Cat No:16093IN-4-CP), (Hindware Contessa F330041), (Jaquar FLR-CHR-5047N) (Hindware - F730041)
Toilet paper holder Make: (Kohler 5633INCP, Jaqur ACNCHR 1153N, CERA F5004110) or similar approved equivalent make (Hindware - F880003)
Bottle trap (Kohler Cat No: 7314IN-CP), (Jaquar ALD CHR-769L300X190) or similar approved equivalent make (Hindware - F850072)
Verticle SS Grab Bar Jaquar WAC-SAP-BR0600CSN, or similar approved equivalent make
Horizontal SS Grab bar Jaquar WAC-SAP-BG0800CSN, or similar approved equivalent make
Item No.
40 mm thick with 20 mm nominal size stone aggregate.
18 mm thick
25 mm thick
Double charge vitrified tile polished finish of size
size of tile 600x1200 mm
Size of tile 600x600 mm
Polished granite stone slab Jet black, Cherry Red, Elite brown, Cat eye or equivalent
b) Same as above but with 8 mm thick polished granite slab in skirting, dado, staircase and other vertical surfaces with single piece slab size 300 mm x 150 mm
i) colour black/Rubby Red/cherry
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand).
Acid and alkaly resistant tile
In Dado/ Skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand).
Acid and alkaly resistant tile
18 mm thick italian marble stone slab, Perlato, Rosso verona, Fire red or Dark Emperadore etc.
1:6 (1 cement : 6 fine sand)
1:6 (1 cement : 6 fine sand)
1:3 (1 cement : 3 fine sand)
New work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
two coats
two or more coats on new work
With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre.
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.
Two or more coats on new work.
Two or more coats on new works including a coat of wood filler.
two coats
Profile B
Fixing with adjustable lugs with split end tail to each jamb
35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):
Rectangular or square
1.5 mm thick
single rubber stopper
(a)Fixed to steel window by welding
b)Fixed to openings /wooden frames with rawl plugs screws etc.
Upto 5mm depth and 5 mm width
With float glass panes of 5.0 mm thickness
With float glass panes of 8 mm thickness
(a) For fixed portion
i. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
(b) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
i. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Particle Board 12 mm thick — Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
With stainless steel cover plate minimum 1.25 mm thickness
12.5 mm thick tapered edge gypsum moisture resistant board
(ii) with semi perforated Gypsum board
(i) with cement bonded particle board conforming to IS:14276
110 mm diameter
160 mm diameter
Screened through sieve of IS designation 16 mm
Holes 90 cm dia, and 90 cm deep.
Holes 60 cm dia, and 60 cm deep.
Common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Trees Plant
Shrubs plant
Hedge Plant
b. Bauhinia purpurea (Kachnar) of plants height 150-165 cm. in big polybags of plants size 25 cm
c. Bottle palm of plants ht. 150-180 cm bottom girth 20-25 cm well devedoped in big poly bags of plants size 25 cm
d. Butea frondosa (Flame of plants Fores ikS/kkt) of plants height 60-75 cm. in big poly bags of plants size 25 cm
e. Callistemon lanceolatus of plants height 150-165 cm. in big poly bags of plants size 25 cm
f. Cassia fistula (Amaltash) of plants height 120-135 cm. in big poly bags of plants size 25 cm
g. Cassia siamea of plants height 150-165 cm. in big poly bags of plants size 25 cm
h. Delonix regia (Gulmohar) of plants height 150-165 cm. in big polybags of plants size 25 cm
i. Ficus elastica Decora (Rubber plant) of plants height 45-60 cm. In earthen pots of plants size 25 cm
k. Ingla dulcis (Jungle Jalebi) of plants height 150-165 cm. in big polybags of plants size 25 cm
m. Lagerstroemia flosreginae of plants height 150-165 cm.in big poly bag of plants size 25 cm
n. Plumeria acutifolia of plants height 120-135 cm. with 2-3 branches in HDPE bag of plants size 30 cm
p. Polyalthia longifolia (Ashok) of plants height 180-195 cm. in gunny bag of plants size 30 cm
q. Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan, Scarlet Queen, Varigata, Glabra Formosa, Peruviana Odissi, Partha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) plant of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots /Plastic pots.
r. Allamanda cathartica plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots
specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, asper the Architectural drawings, as per item description, asspecified, as per the approved shop drawings and as directedby the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainlesssteel wire mesh shall be paid for separately under
relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science &Technologies, India. Cost of testing is payable separately.The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing systemTests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
i. Kitchen sink with drain board
510x1040 mm bowl depth 200mm.
ii. Kitchen sink without drain board
610x510 mm bowl depth 200mm.
b) Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete
Flexible pipe
32 mm dia
c) Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45gms.
d) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
e) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
CP Brass
15 mm nominal bore
White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
b) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
c) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
W.C. pan with ISI marked white solid plastic seat and lid.
b) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
c) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
b. Providing and fixing PTMT urinal cock of approved quality and colour
15 mm nominal bore, 80 mm long, 42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms
c. Providing and fixing PTMT 15 mm urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 gms
a) Urinal Make: (Kohler Cat No: 5017IN-ER-0), Jaquar URS-WHT-132530) or similar approved equivalent make (Hindware - 96014)
b) Automatic flushing system for urinal Make: (Kohler 8791T-C01-CP), Jaquar SNR-CHR-51097) or similar approved equivalent make (Hindware - F860083)
c) Bottle trap Make: (Kohler Cat No: 7314IN-CP), (Jaquar ALD CHR-769L300X190) or similar approved equivalent make (Hindware - F850072)
White Vitreous China flat back Wash basin size 550x400 mm with single 15 mm C.P. brass pillar taps.
b) Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete
Flexible pipe
32 mm dia
c) Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45gms.
d) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
e) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers Isi marked
b) Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete
Flexible pipe
32 mm dia
c) Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45gms.
d) Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
e) Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
Granite of any colour and shade
Area of slab above 0.50 sqm
b. Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Granite work
c. Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. Complete
d) Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
15 mm nominal bore.
15 mm nominal bore.
600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms
b. Providing and fixing CP bras shower rose with 15 or 20 mm inlet
150 mm diameter
Flexible pipe
32 mm dia
40 mm dia
45 cm length
15 mm nominal bore
Granite Stone of approved shade
110 mm dia pipes with minimum wall thickness of 3.20mm.
75 mm dia pipes with minimum wall thickness of 3.20mm.
100 mm inlet and 100 mm outlet
100 mm inlet and 75 mm outlet
Internal work - Exposed on wall
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
25 mm nominal bore
32 mm nominal bore.
40 mm nominal bore
50 mm nominal bore
Circular tank
15 mm nominal bore
15 mm nominal bore
15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms.
Circular type
100 mm nominal dia
100 mm nominal dia with 25 mm waste hole
25 mm nominal bore
SUMMARY OF ARCHITECTURAL COSTS (NEW PROJECT OFFICE BUILDING + 3NOs. OF GATE COMPLEXES
Table -3
Name of the Plant/ Unit:
Package Name :
Package No.
PRICE SCHEDULE FOR CIVIL WORKS ON ITEM RATE BASIS
New Project Office Building with HVAC-Electrical Substation Building with HVAC-cum-Electrical Subsation Building, Bitumen Road, CC Block Drain, Septic Tank & Soak Pit for 100 Users
Item No.
SECTION - SC [SITE CLEARANCE]
SUB TOTAL: SC:
SECTION - EW [EARTHWORK]
(The measurement for payment shall be for the theoretical excavation volume only as per drawing i.e. for the volume of the block of the excavation having the depth and maximum bottom dimensions of the foundation/structures as per drawing after deducting corresponding quantity of hard rock if any paid separately under respective items. The Bidder shall take into account in his rate the provision for any excess excavation for necessary working space, steps, sloping etc required for excavation safety and other allied works and refilling the side slopes/working space etc.).
( a ) Up to 1.5m depth
( b ) More than 1.5m but not exceeding 3.0m
(The measurement for payment shall be for the theoretical backfilling volume only as per drawing i.e. for the volume of the compacted backfilling calculated based on spot level before backfilling and finished terrace level).
SUB TOTAL: EW:
SECTION - AT [ANTI-TERMITE TREATMENT]
SUB TOTAL: AT:
SECTION - CC [PLAIN & REINFORCED CONCRETE]
(a) Grade M-5 with stone aggregate 40mm and down size.
(b) Grade M-7.5 with stone aggregate 40mm and down size.
(c) Grade M-10 with stone aggregate 20mm and down size.
(d) Grade M-15 with stone aggregate 20mm and down size.
(a) Grade M-25 (upto Plinth Level)
(b) Grade M-25 (above Plinth Level)
(a) In all types of foundations, footings, equipment foundations, rafts, walls, columns, trenches, beams, slabs, and any other similar type of works up to Plinth level.
(b) In Suspended floors, roofs, landings, balconies, access platform, Lintels, beams, beams, cantilevers, Shelves, Columns, stairs and any other similar type of works above plinth level.
(a) Plain mild steel bars
(b) High strength deformed steel bars / TMT bars/ TOR Bars
( ii ) Fe – 500 Grade (Min.)
(a) 1:3 mortar(1cement :3sand)
SUB TOTAL: CC:
SECTION - FL [FLOORING]
SUB TOTAL: FL:
SECTION - MN [BRICK & STONE MASONRY]
(a) 1:6mortar(1cement :6sand)
(a) For Boundary Wall
SUB TOTAL: MN:
SECTION - WP [WATER PROOFING]
SUB TOTAL: WP:
SECTION - MS [MISCELLANEOUS WORKS]
a) 450 mm diameter RCC pipe
150 x 100 mm size P type.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
(a) 160 mm dia
(b) 200 mm dia
(Necessary excavation in trenches at all depths and backfilling after laying of pipe and disposal of surplus earth upto 100m lead is to be paid under respective items).
(a) M.S. tube
(b) G.I Pipes
a) 50 mm dia
b) 65 mm dia
c) 80 mm dia
d) 100 mm dia
e) 150 mm dia
f) 200 mm dia
g) 250 mm dia
a) Manually operated
b) Gear/chain-pully operated
SUB TOTAL: MS:
SECTION : ROADWORK [RD]
a) As per approved compacted thickness mentioned in the drawing with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity.
a) As per approved compacted thickness mentioned with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity.
a) On W.B.M. @ 0.75 Kg / sqm
b) On bituminous surface @ 0.50 Kg / sqm
SUB TOTAL: RD:
01 No. Main Gate Complex & 02 Nos. Material Gate Complex (Excluding Road and drain covering in separate road package but including Septic tank & soak pit for 20 users for each GC
Item No.
SECTION - SC [SITE CLEARANCE]
SUB TOTAL: SC:
SECTION - EW [EARTHWORK]
(The measurement for payment shall be for the theoretical excavation volume only as per drawing i.e. for the volume of the block of the excavation having the depth and maximum bottom dimensions of the foundation/structures as per drawing after deducting corresponding quantity of hard rock if any paid separately under respective items. The Bidder shall take into account in his rate the provision for any excess excavation for necessary working space, steps, sloping etc required for excavation safety and other allied works and refilling the side slopes/working space etc.).
( a ) Up to 1.5m depth
( b ) More than 1.5m but not exceeding 3.0m
(The measurement for payment shall be for the theoretical backfilling volume only as per drawing i.e. for the volume of the compacted backfilling calculated based on spot level before backfilling and finished terrace level).
SUB TOTAL: EW:
SECTION - AT [ANTI-TERMITE TREATMENT]
SUB TOTAL: AT:
SECTION - CC [PLAIN & REINFORCED CONCRETE]
(a) Grade M-5 with stone aggregate 40mm and down size.
(b) Grade M-7.5 with stone aggregate 40mm and down size.
(c) Grade M-10 with stone aggregate 20mm and down size.
(d) Grade M-15 with stone aggregate 20mm and down size.
(a) Grade M-25 (upto Plinth Level)
(a) Grade M-25 (above Plinth Level)
(a) In all types of foundations, footings, equipment foundations, rafts, walls, columns, trenches, beams, slabs, and any other similar type of works up to Plinth level.
(b) In Suspended floors, roofs, landings, balconies, access platform, Lintels, beams, beams, cantilevers, Shelves, Columns, stairs and any other similar type of works above plinth level.
(a) Plain mild steel bars
(b) High strength deformed steel bars / TMT bars/ TOR Bars
( ii ) Fe – 500 Grade (Min.)
i) Using Concrete of grade M-25
(a) Weight of individual element upto 0.5 tonne
(b) Weight of individual element exceeding 0.5 tonne but upto 1.0 tonne
(a) 1:3 mortar(1cement :3sand)
SUB TOTAL: CC:
SECTION - FL [FLOORING]
SUB TOTAL: FL:
SECTION - MN [BRICK & STONE MASONRY]
(a) 1:6mortar(1cement :6sand)
(a) For Boundary Wall
SUB TOTAL: MN:
SECTION - WP [WATER PROOFING]
SUB TOTAL: WP:
SECTION - MS [MISCELLANEOUS WORKS]
a) 450 mm diameter RCC pipe
150 x 100 mm size P type.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
(a) 160 mm dia
(b) 200 mm dia
(Necessary excavation in trenches at all depths and backfilling after laying of pipe and disposal of surplus earth upto 100m lead is to be paid under respective items).
(a) M.S. tube
(b) G.I Pipes
a) 50 mm dia
b) 65 mm dia
c) 80 mm dia
d) 100 mm dia
e) 150 mm dia
f) 200 mm dia
g) 250 mm dia
a) Manually operated
b) Gear/chain-pully operated
SUB TOTAL: MS:
SECTION : ROADWORK [RD]
a) As per approved compacted thickness mentioned in the drawing with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity.
a) As per approved compacted thickness mentioned with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity.
a) On W.B.M. @ 0.75 Kg / sqm
b) On bituminous surface @ 0.50 Kg / sqm
SUB TOTAL: RD:
SUMMARY OF CIVIL COSTS (NEW PROJECT OFFICE BUILDING + 3NOs. OF GATE COMPLEXES
Table -4
Name of the Plant/ Unit:
Package Name :
Package No.
PRICE SHEDULE FOR SUPPLY AND ERECTION/INSTALLATION WORKS ON ITEM RATE BASIS
NEW PROJECT OFFICE BUILDING
UNIT RATE INCLUDING FREIGHT, INSURANCE, EXCL. GST
CCTV system as per TS
Telephone Network system as per TS
Fire Detection and Alarm system as per TS
Sub-Total (A)
Pumps, flow: 2m3/hr @ 25mWC
GI Pipe-DN32
GI Pipe-DN40
PVC Tank-2m3
Gate Valves-DN32
Gate Valves-DN40
Motorised Gate Valve-DN40
Non Return Valve-DN32
REJ-DN40
REJ-DN32
GI Fitting {elbows (45° and 90°), tees (equal and reducing), concentric and eccentric reducers, bends, couplings, unions, crosses, nipples, caps, plugs, flanges, flange adapters, dismantling joints, expansion joints, and branch connections, gasket etc.} and pipe supports {pipe clamps, U-bolts, pipe saddles, brackets, wall supports, floor-mounted supports, ceiling hangers, clevis hangers, adjustable supports, guide supports and anchor supports etc.}
CS Pipe with wrapping coating for underground-DN40
CS Fitting {elbows (45° and 90°), tees (equal and reducing), concentric and eccentric reducers, bends, couplings, unions, crosses, nipples, caps, plugs, flanges, flange adapters, dismantling joints, expansion joints, and branch connections, gasket etc.} and pipe supports {pipe clamps, U-bolts, pipe saddles, brackets, wall supports, floor-mounted supports, ceiling hangers, clevis hangers, adjustable supports, guide supports and anchor supports etc.}
CS Pipe for encasing-DN250
Sub-Total (B)
Sprinkler and Wet riser system Design, supply, install, test and commission a complete automatic wet-type sprinkler system for office buildings in accordance with the latest applicable NBC Part-4 and IS 15105:latest
Internal wet riser system and External Hydrant SYSTEM Fire hydrant/ Landing valves shall be provided with a hose box that shall be fabricated out of fibre reinforced plastic to house 2 nos. of type-III 15 mtrs length fire hoses with SS couplings, SS branch pipe with nozzle and spanner. The box shall be fitted with double door having glass panel.
Extinguishers Portable fire extinguishers shall be provided in all proposed areas/rooms. Type and quantity of fire extinguishers shall be as per IS-2190 latest edition. The design and construction of fire extinguishers shall be as per IS-15683 latest edition and ISI marked.
Sub-Total (C)
Sub-Total (D)
Split AC- Air conditioning system
VENTILATION SYSTEMS:
Sub-Total (E)
Design, Engineering, Supply, Erection, Testing, Commissioning and PG of Grid synchronization of On grid Roof-Top solar of 100 kWp Solar PV Power Plant including Solar photovoltaic module,Solar Grid Inverter/PCU including Isolation Transformer ,PVC/XLPE, Cu/Al Cables,DC Solar cable,Conventional Lightning Arrestor,Module Mounting Structure,ACDB,Installation Accessories (Hardware/ Lugs/ Ferrules/ Miscellaneous),Module Cleaning Pipeline ( PVC ) etc as per Technical Specification.
Sub-Total (F)
Supply, installation, erection, testing and commissioning of all electrical items comprising of HT Cables, Control Cables, Jointing Kit ,HT Termination Kit ,Distribution transformers, Bus duct ,PCCs, VCBs without protection , Main PDB , PDBs, MCB DBs,MLDB ,LDB,SLDB, UPS ,UPS DB ,Complete illumination including lighting transformers, Light fittings, lighting poles, Fans, Pedestral Fans, Modular switchboards with sockets & switches, Sensors with cables complete with hardware and software as required ,MCC for Chiller Plant Loads ,Power cables, Control cables,Wires , Local Control stations, Complete Earthing and Lightning protection with strip & Earthing Pits, Junction Boxes , Cable Gland,Lugs ,Cable Trays , Angle ,Channel,Insert plates,fastener,Chequered plates etc as per the Technical Specifications and project requirements.
Sub-Total (G)
Network Components - Equipment/Item
Managed Layer3 Building switch with redundant fiber modules
Managed Layer 2 Edge Switch without fibre modules
9U Racks
18U Racks
Single Port, Category 6 Information Outlet for client PCs
Network passive components (like Fibre patch cable, fiber patch panel, FO pigtail connectors, UTP patch panel, UTP patch cord, RJ45 connector etc.) for 6 core SMF cable termination and UTP termination
Supply & Laying of UTP cable in 1” PVC conduit/casing/capping (in meters)
Supply & Laying of SMF cable in 1.5” HDPE conduit (in meters)
Supply & Laying of SMF cable in 1” GI pipe (in meters)
Fusion/Splicing
Power Supply
Earthing System
Spares and Consumables
Tools & tackles
Sub-Total (H)
GATE COMPLEXES (3 Nos.)- ONE MAIN & TWO MATERIAL GATES
UNIT RATE INCLUDING FREIGHT, INSURANCE, EXCL. GST
CCTV system as per TS
Telephone Network system as per TS
Fire Detection and Alarm system as per TS
Public Address system as per TS
Sub-Total (A)
Pumps, flow: 2m3/hr @ 25mWC
GI Pipe-DN32
GI Pipe-DN40
PVC Tank-2m3
Gate Valves-DN32
Gate Valves-DN40
Motorised Gate Valve-DN40
Non Return Valve-DN32
REJ-DN40
REJ-DN32
GI Fitting {elbows (45° and 90°), tees (equal and reducing), concentric and eccentric reducers, bends, couplings, unions, crosses, nipples, caps, plugs, flanges, flange adapters, dismantling joints, expansion joints, and branch connections, gasket etc.} and pipe supports {pipe clamps, U-bolts, pipe saddles, brackets, wall supports, floor-mounted supports, ceiling hangers, clevis hangers, adjustable supports, guide supports and anchor supports etc.}
CS Pipe with wrapping coating for underground-DN40
CS Fitting {elbows (45° and 90°), tees (equal and reducing), concentric and eccentric reducers, bends, couplings, unions, crosses, nipples, caps, plugs, flanges, flange adapters, dismantling joints, expansion joints, and branch connections, gasket etc.} and pipe supports {pipe clamps, U-bolts, pipe saddles, brackets, wall supports, floor-mounted supports, ceiling hangers, clevis hangers, adjustable supports, guide supports and anchor supports etc.}
CS Pipe for encasing-DN250
Sub-Total (B)
External Hydrant System - Fire hydrant/ Landing valves shall be provided with a hose box that shall be fabricated out of fibre reinforced plastic to house 2 nos. of type-III 15 mtrs length fire hoses with SS couplings, SS branch pipe with nozzle and spanner. The box shall be fitted with double door having glass panel.
Extinguishers - Portable fire extinguishers shall be provided in all proposed areas/rooms. Type and quantity of fire extinguishers shall be as per IS-2190 latest edition. The design and construction of fire extinguishers shall be as per IS-15683 latest edition and ISI marked
Sub-Total (C)
2 TR Min. 3 BEE Split AC consisting of outdoor unit, indoor unit, refrigerant copper piping with thermal insulation, support structure, brackets, condensate drain piping, insulation, remotes, power socket, power cables, cable trays and all other standard accessories.
Sub-Total (D)
Supply, installation, erection, testing and commissioning of all electrical items comprising of PDBs, MCB DBs,SLDB, UPS ,UPS DB , Lighting & illumination , Light fittings, Lighting poles,High Mast , Fans, , Modular switchboards with sockets & switches,Power cables, Control cables,Wires , Local Control stations, Complete Earthing and Lightning protection with strip & earthing pits ,Junction Boxes , Cable Gland,Lugs ,Cable Trays , Angle ,Channel,Insert plates,fastener,Chequered plates etc as per the Technical Specifications and project requirements.
Sub-Total (E)
Network Components - Equipment/Item
Managed Layer 2 Edge Switch without fibre modules
9U Racks
Single Port, Category 6 Information Outlet for client PCs
Network passive components (like Fibre patch cable, fiber patch panel, FO pigtail connectors, UTP patch panel, UTP patch cord, RJ45 connector etc.) for 6 core SMF cable termination and UTP termination
Supply & Laying of UTP cable in 1” PVC conduit/casing/capping (in meters)
Supply & Laying of SMF cable in 1.5” HDPE conduit (in meters)
Supply & Laying of SMF cable in 1” GI pipe (in meters)
Fusion/Splicing
Power Supply
Earthing System
Sub-Total (F)
SUMMARY OF COSTS
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
1794917158678_Integrity Pact.pdf
NIT • 11.94 MB
1794910092754_TECHNICAL SPECIFICATION.pdf
NIT • 4.79 MB
BSP GATE COMPLEX 3 NOS KEY PLAN.pdf
NIT • 1.25 MB
Main Employee Gate.pdf
NIT • 0.56 MB
Material Gate.pdf
NIT • 0.14 MB
Drawing - Key site plan.pdf
NIT • 0.08 MB
Drawing - New Admin Building Gr. Floor.pdf
NIT • 0.15 MB
Drawing - New Admin Building 1st Floor.pdf
NIT • 0.18 MB
Drawing - New Admin Building 2nd Floor.pdf
NIT • 0.14 MB
SPECIAL CONDITIONS OF CONTRACT.pdf
NIT • 1.01 MB
Tender Schedule with itemwise estimated cost.xlsx
NIT • 0.13 MB
INVITATION TO TENDER.pdf
NIT • 1.20 MB
Amendment to the Safety Conditions of Contracts.pdf
NIT • 0.18 MB
General Conditions of Contract SAIL-S1.pdf
NIT • 1.29 MB
Guidelines for Banning of Buiseness Dealings.pdf
NIT • 0.56 MB
Safety conditions for contract.pdf
NIT • 0.34 MB
Scheme for settlement of disputes (OEC).pdf
NIT • 0.86 MB
GTS -Vol 1 of 3_3. GTS-03 Part-I Sec-C.pdf
NIT • 0.39 MB
GTS -Vol 1 of 3_3. GTS-03 Part-II.pdf
NIT • 1.13 MB
GTS -Vol 1 of 3_3. GTS-03-PART III.pdf
NIT • 2.49 MB
GTS -Vol 1 of 3_4. GTS-04.pdf
NIT • 1.15 MB
GTS -Vol 1 of 3_5. GTS-05.pdf
NIT • 3.50 MB
GTS -Vol 1 of 3_6. GTS-06.pdf
NIT • 1.12 MB
GTS -Vol 1 of 3_7. GTS-07.pdf
NIT • 1.25 MB
GTS -Vol 1 of 3_8. GTS-08.pdf
NIT • 1.31 MB
GTS -Vol 1 of 3_9. GTS-09.pdf
NIT • 2.41 MB
GTS -Vol 1 of 3_10. GTS-10.pdf
NIT • 0.62 MB
GTS -Vol 1 of 3_10. GTS-10-01.pdf
NIT • 0.75 MB
GTS -Vol 1 of 3_10. GTS-10-02.pdf
NIT • 0.71 MB
GTS -Vol 1 of 3_10. GTS-10-03.pdf
NIT • 0.75 MB
GTS -Vol 1 of 3_10. GTS-10-04.pdf
NIT • 0.75 MB
GTS -Vol 1 of 3_10. GTS-10-05.pdf
NIT • 0.85 MB
GTS -Vol 1 of 3_10. GTS-10-06.pdf
NIT • 0.70 MB
GTS -Vol 1 of 3_10. GTS-10-07.pdf
NIT • 0.72 MB
GTS -Vol 1 of 3_10. GTS-10-08.pdf
NIT • 0.70 MB
GTS -Vol 1 of 3_10. GTS-10-09.pdf
NIT • 0.66 MB
GTS -Vol 1 of 3_10. GTS-10-10.pdf
NIT • 0.73 MB
GTS -Vol 1 of 3_10. GTS-10-11.pdf
NIT • 0.73 MB
GTS -Vol 1 of 3_10. GTS-10-12.pdf
NIT • 0.59 MB
GTS -Vol 1 of 3_10. GTS-10-13.pdf
NIT • 0.68 MB
GTS -Vol 1 of 3_10. GTS-10-14.pdf
NIT • 0.71 MB
GTS -Vol 1 of 3_10. GTS-10-15.pdf
NIT • 0.72 MB
GTS -Vol 1 of 3_10. GTS-10-16.pdf
NIT • 0.73 MB
GTS -Vol 1 of 3_10. GTS-10-17.pdf
NIT • 0.73 MB
GTS -Vol 1 of 3_10. GTS-10-18.pdf
NIT • 0.85 MB
GTS -Vol 1 of 3_10. GTS-10-19.pdf
NIT • 0.72 MB
GTS -Vol 1 of 3_10. GTS-10-20.pdf
NIT • 0.71 MB
GTS -Vol 1 of 3_10. GTS-10-21.pdf
NIT • 0.69 MB
GTS -Vol 1 of 3_10. GTS-10-22.pdf
NIT • 0.67 MB
GTS -Vol 1 of 3_10. GTS-10-23.pdf
NIT • 0.69 MB
GTS -Vol 1 of 3_10. GTS-10-24.pdf
NIT • 0.69 MB
GTS -Vol 1 of 3_10. GTS-10-25.pdf
NIT • 0.69 MB
GTS -Vol 1 of 3_10. GTS-10-26.pdf
NIT • 0.59 MB
GTS -Vol 1 of 3_10. GTS-10-27.pdf
NIT • 0.60 MB
GTS -Vol 1 of 3_10. GTS-10-28.pdf
NIT • 0.70 MB
GTS -Vol 1 of 3_1. GTS-01.pdf
NIT • 0.79 MB
GTS -Vol 1 of 3_2. GTS-02.pdf
NIT • 0.87 MB
GTS -Vol 1 of 3_3. GTS-03 Part-I Sec-A.pdf
NIT • 0.67 MB
GTS -Vol 1 of 3_3. GTS-03 Part-I Sec-B.pdf
NIT • 2.46 MB
GTS-Vol 2 of 3_17. GTS-17.pdf
NIT • 1.65 MB
GTS-Vol 2 of 3_11. GTS-11.pdf
NIT • 1.61 MB
GTS-Vol 2 of 3_12. GTS-12.pdf
NIT • 1.09 MB
GTS-Vol 2 of 3_13. GTS-13-01.pdf
NIT • 0.81 MB
GTS-Vol 2 of 3_13. GTS-13-02.pdf
NIT • 0.80 MB
GTS-Vol 2 of 3_13. GTS-13-03.pdf
NIT • 0.63 MB
GTS-Vol 2 of 3_13. GTS-13-04.pdf
NIT • 0.74 MB
GTS-Vol 2 of 3_13. GTS-13-06.pdf
NIT • 1.42 MB
GTS-Vol 2 of 3_13. GTS-13-07.pdf
NIT • 1.39 MB
GTS-Vol 2 of 3_13. GTS-13-08.pdf
NIT • 1.50 MB
GTS-Vol 2 of 3_13. GTS-13-09.pdf
NIT • 1.10 MB
GTS-Vol 2 of 3_14. GTS-14.pdf
NIT • 0.19 MB
GTS-Vol 2 of 3_14. GTS-14-01.pdf
NIT • 0.24 MB
GTS-Vol 2 of 3_14. GTS-14-02.pdf
NIT • 0.25 MB
GTS-Vol 2 of 3_14. GTS-14-03.pdf
NIT • 0.22 MB
GTS-Vol 2 of 3_14. GTS-14-04.pdf
NIT • 0.24 MB
GTS-Vol 2 of 3_14. GTS-14-05.pdf
NIT • 0.21 MB
GTS-Vol 2 of 3_14. GTS-14-06.pdf
NIT • 0.24 MB
GTS-Vol 2 of 3_14. GTS-14-07.pdf
NIT • 0.23 MB
GTS-Vol 2 of 3_14. GTS-14-08.pdf
NIT • 0.23 MB
GTS-Vol 2 of 3_14. GTS-14-09.pdf
NIT • 0.22 MB
GTS-Vol 2 of 3_14. GTS-14-10.pdf
NIT • 0.22 MB
GTS-Vol 2 of 3_14. GTS-14-11.pdf
NIT • 0.25 MB
GTS-Vol 2 of 3_14. GTS-14-12.pdf
NIT • 0.22 MB
GTS-Vol 2 of 3_14. GTS-14-13.pdf
NIT • 0.38 MB
GTS-Vol 2 of 3_14. GTS-14-14.pdf
NIT • 0.40 MB
GTS-Vol 2 of 3_14. GTS-14-15.pdf
NIT • 0.26 MB
GTS-Vol 2 of 3_15. GTS-15.pdf
NIT • 0.14 MB
GTS-Vol 2 of 3_15. GTS-15-01.pdf
NIT • 1.03 MB
GTS-Vol 2 of 3_15. GTS-15-02.pdf
NIT • 0.73 MB
GTS-Vol 2 of 3_15. GTS-15-03.pdf
NIT • 0.87 MB
GTS-Vol 2 of 3_15. GTS-15-04.pdf
NIT • 0.25 MB
GTS-Vol 2 of 3_15. GTS-15-05.pdf
NIT • 0.48 MB
GTS-Vol 2 of 3_15. GTS-15-06.pdf
NIT • 0.26 MB
GTS-Vol 2 of 3_15. GTS-15-07.pdf
NIT • 0.22 MB
GTS-Vol 2 of 3_15. GTS-15-08.pdf
NIT • 0.21 MB
GTS-Vol 2 of 3_15. GTS-15-09.pdf
NIT • 0.23 MB
GTS-Vol 2 of 3_15. GTS-15-10.pdf
NIT • 1.19 MB
GTS-Vol 2 of 3_15. GTS-15-12.pdf
NIT • 0.73 MB
GTS-Vol 2 of 3_15. GTS-15-13.pdf
NIT • 0.73 MB
GTS-Vol 2 of 3_15. GTS-15-14.pdf
NIT • 0.30 MB
GTS-Vol 2 of 3_15. GTS-15-15.pdf
NIT • 0.23 MB
GTS-Vol 2 of 3_15. GTS-15-16.pdf
NIT • 0.23 MB
GTS-Vol 2 of 3_15. GTS-15-17.pdf
NIT • 0.22 MB
GTS-Vol 2 of 3_15. GTS-15-18.pdf
NIT • 0.20 MB
GTS-Vol 2 of 3_15. GTS-15-19.pdf
NIT • 0.26 MB
GTS-Vol 2 of 3_15. GTS-15-20.pdf
NIT • 0.73 MB
GTS-Vol 2 of 3_15. GTS-15-21.pdf
NIT • 0.22 MB
GTS-Vol 2 of 3_15. GTS-15-22.pdf
NIT • 0.21 MB
GTS-Vol 2 of 3_15. GTS-15-23.pdf
NIT • 0.21 MB
GTS-Vol 2 of 3_15. GTS-15-24.pdf
NIT • 0.20 MB
GTS-Vol 2 of 3_15. GTS-15-25.pdf
NIT • 0.29 MB
GTS-Vol 2 of 3_16. GTS-16.pdf
NIT • 9.01 MB
GTS - Vol-3 of 3_18. GTS-18-09 Preferred Makes for FLUID SYSTEM.pdf
NIT • 0.75 MB
GTS - Vol-3 of 3_18. GTS-18-10 Preferred Makes for ACVS.pdf
NIT • 0.71 MB
GTS - Vol-3 of 3_18. GTS-18-11 Preferred Makes for GASES AND LIQUID FUELS.pdf
NIT • 0.68 MB
GTS - Vol-3 of 3_18. GTS-18-12 Preferred Makes for Power Plant & Energy.pdf
NIT • 0.71 MB
GTS - Vol-3 of 3_18. GTS-18-13 Preferred Makes for Fire Protection System.pdf
NIT • 0.69 MB
GTS - Vol-3 of 3_18. GTS-18-14 Preferred Makes for Environmental section unit & equipment.pdf
NIT • 0.82 MB
GTS - Vol-3 of 3_18. GTS-18-15 Preferred Makes for MATERIAL HANDLING.pdf
NIT • 0.96 MB
GTS - Vol-3 of 3_18. GTS-18.pdf
NIT • 0.54 MB
GTS - Vol-3 of 3_18. GTS-18-01 Preferred Makes for Refractory.pdf
NIT • 0.90 MB
GTS - Vol-3 of 3_18. GTS-18-02 Preferred Makes for Instrumentation.pdf
NIT • 0.74 MB
GTS - Vol-3 of 3_18. GTS-18-03 Part-1,2&3 Preferred Make for Electrical.pdf
NIT • 0.84 MB
GTS - Vol-3 of 3_18. GTS-18-04 INFORMATION TECHNOLOGY SYSTEM.pdf
NIT • 0.68 MB
GTS - Vol-3 of 3_18. GTS-18-05 Preferred Makes for CIVIL.pdf
NIT • 0.71 MB
GTS - Vol-3 of 3_18. GTS-18-06 Preferred Makes for Architectural.pdf
NIT • 0.91 MB
GTS - Vol-3 of 3_18. GTS-18-07 Preferred Makes for STRUCTURAL.pdf
NIT • 0.67 MB
GTS - Vol-3 of 3_18. GTS-18-08 Preferred Makes for Lubrication & Hydraulics.pdf
NIT • 0.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .