Superintending Engineer, EDC, Hapur
Superintending Engineer, EDC, Hapur
Replacement of tillted pole, line etc, in area of EDD- Garh
2024_PVVNL_933240_2
14(W)/EDCH/2024-25
Open Tender
Electrical Works
Lump-sum
Hapur
ebnclosd
3 documents required · 3 mandatory
₹1,180
SE, EDC, Hapur
₹2,000
6 Sept 2024
22 Aug 2024
28 Aug 2024
22 Aug 2024
28 Aug 2024
22 Aug 2024
Amount
FOR REPLACEMENT OF TILTED POLS, LINES & ATTENDDING BREAKDOWN ETC. (RUNNING CONTRACT) IN THE AREA OF EDD-GARHMUKTESHWER, UNDER EDC., HAPUR.
Carriage of line material (like 11KV XLPE Cable 3x35-3x70+3x120-3x185sqmm, and 33KV XLPE Cable 3x185/240/300 Sqmm and LT Abc etc.) from JE Store/Electricity Store Center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
Carriage of PCC Pole 8.5mtrs long support from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
Carriage of ST Pole 11mtrs long support from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
Erection & Fixing of PCC Pole 8.5 mtr. long in LT. line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing L.T. Pin Clamps, M.S. Flat of size 50x6 & Schacle Insulator of size 75x90mm, with proper size nuts and bolts, as per direction of site incharge.
Erection & Fixing of PCC Pole 8.5 mtr. long in 11 KV line after digging of suitable pits including fixing of requisite all accessories as per RESPO Drawing/Norms by providing F-Bracket and holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts., as per direction of site incharge.
Erection & Fixing of STP Pole 11 mtr. long in 11 KV line after digging of suitable pits including fixing of requisite all accessories as per RESPO Drawing/Norms by providing F-Bracket and holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts., as per direction of site incharge.
Erection & Fixing of STP Pole 11 mtr. long in 33 KV line after digging of suitable pits including fixing of requisite all accessories as per RESPO Drawing/Norms by providing F-Bracket and holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts., as per direction of site incharge.
Grouting of following STP Pole supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials, as per direction of site incharge.
Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops, as per direction of site incharge.
Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts , as per direction of site incharge.
Laying of following XLPE Cable after digging of earth for making trench by providing good quality brick at three sides of cable and filling of soil and sand in cable trench, including cost of all required fixing material and labour etc. spare cable shall be left in the loop shape at both ends, as per direction of site incharge.
(a) 3x35-3x70+3x120-3x185sqmm 11KV XLPE Cable
(b) 3x185/240/300 Sqmm 33KV XLPE Cable.
Dismantling & removal of existing ACSR Conductor and opening of all accessories and bundling the same at various places , as per direction of site incharge.
Stringging, Saggging of old loose ACSR Conductor & proper completion of work as per RESPO/Drawing Norms, as per direction of site incharge.
(a) ABC Conductor
(b) ACSR Weasel Conductor
(c) ACSR Rabbit Conductor
(d) ACSR Dog Conductor
Re-straightening of Tilted Pole after digging of pit of suitable size adjustment of ST/P.C.C Poles as per RESPO/Drawing Norms and as per direction of site incharge.
Dismantling & Removal of old and used STP (Scrap)/PCC Pole, after digging of pit of suitable size and removal of all accessoires as per RESPO/Drawing Norms and as per direction of site incharge.
Laying Stringging & Final Saggging of ACSR Conductor & proper completion of work as per RESPO/Drawing Norms and as per direction of site incharge.
(a) ABC Conductor
(b) ACSR Weasel Conductor
(c) ACSR Rabbit Conductor
(d) ACSR Dog Conductor
Carriage of old & damaged STP Scrap/PCC Pole, from site of work to JE Store/Electricity Store Centre Hapur including loading and unloading at both the ends on Kachha and Packka road., as per direction of site incharge.
Carriage of old & damaged scrap ABC/Acsr Conductor, from site of work to Electricity Store Centre Hapur including loading and unloading at both the ends on Kachha and Packka road., as per direction of site incharge.
Jumpering and line energisation work properly as per RESPO/Norms and as per direction of site incharge.
BANTI SINGH ELECTRICALS CO
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .