| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹10.5 L+₹1.0 L (10.7%)Rejected-Finance 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹12.4 L+₹2.9 L (31.0%)Rejected-Finance 8 6TH CROSS MATHRU SHREE NILAYA OPP MAHARISHI RESIDENCE KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹13.7 L+₹4.2 L (44.4%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹14.0 L+₹4.6 L (48.2%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹23,300
Closing Date
21 Oct 2022, 5:00 pmClosed
AGE I AF CHIMNEY HILLS BANGALORE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
SPECIAL REPAIR FOR REPLACEMENT OF CFL LIGHT FITTINGS TO LED LIGHT IN TESTING HALL, SUB GUARD ROOM, MAIN GUARD ROOM, AIRMEN BILLET AND MESS ACTIVITY ROOM AND P-90, 91 AND P-92 BLOCK INCLUDING INTERNAL WIRING AT NO. 2 AFSB MYSORE
2022_MES_543992_2
8538/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
AGE I AF CHIMNEY HILLS BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE I AF CHIMNEY HILLS BANGALORE
₹23,300
Yes
12 Jan 2023
7 Oct 2022
22 Oct 2022
7 Oct 2022
21 Oct 2022
14 Oct 2022
7 Oct 2022 - 10 Oct 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for Point wiring with 1.5 sqmm, single core ,PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of same size as in phase/neutral and connected to common earth dolly drawn through and including rigid PVC conduit of suitable size alongwith fittings and accessories, fixed /laid/concealed in walls/ceilings including cutting chases and making good to walls, floors etc, and also incl suitable sunken type pressed steel terminal box and suitable laminated sheet top cover for the following :- One light/Ceiling fan/ EF/Wall Fan controlled by one, one way switch
One light controlled by Two, Two way switch
One three pin socket outlet 5 Amp controlled by one, one way switch on independent board
All as per above but with 2.5 sqmm and 2.5 sqmm as earth conductor on independent board for 15 Amp Socket
All as per above but with 4 sqmm and 4 sqmm as earth conductor on independent board for 15 Amp Socket
Supply and Fix Modular switch 2 way 6A, 1 module
Supply and fix Modular switch 1 way 6A, 1 module
Supply and fix Modular switch 1 way 16A, 1 module
Supply and fix Modular Socket, 6A - 2/3 pin combined 2 module,
Supply and fix Modular 0 Socket 6A/16A - 2/3 pin combined 2 module,
S & F Modular Fan step regulator, 120W - 2 module
Supply and Fix Modular white cover Plate with Frame 01 Module
Supply and Fix Modular white cover Plate with Frame 02 Module
Supply and Fix Modular white cover Plate with Frame 03 Module
Supply and Fix Modular white cover Plate with Frame 04 Module
Supply and Fix Modular white cover Plate with Frame 06 Module
Supply and Fix Modular Metal Flush box 01/ 02 Module
Supply and Fix Modular Metal Flush box 3 Module
Supply and Fix Modular Metal Flush box 4 Module
Supply and Fix Modular Metal Flush box 6 Module
Supply and fix ceiling rose 3 Phase / PVC/ Polycarbonate, isolated body.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED lights fitting 1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and Fix Single pole and neutral enclosure witha two pin and earth plug and socket complete with one single pole 20 Amp MCB
S&F in replacement SPN distribution boards protection class IP-43 single door suitable for mounting MCB with min 200 Amps rating bus bar SPN 08 way.
S&F in replacement distribution boards protection class IP-43 single door suitable for mounting MCB with suitable rating bus bar TPN 4 way.
S&F in replacement distribution boards protection class IP-43 doubble door suitable for mounting MCB with suitable rating bus bar TPN 12 way.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of Four poles and current carrying capacity 63 Amp to 100Amps in the DB complete with connection testing and commissioning.
Supply and fixing 6 to 32 amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning
All as per above but SPN 40 Amp
Removing of Ceiling Fan from site, Carrying to workshop, Cleaning, Greasing and Refixing at same location
Removing of Exhaust Fan from site, Carrying to workshop, Cleaning, Greasing and Refixing at same location
Removing of Wall Mounted Fan from site, Carrying to workshop, Cleaning, Greasing and Refixing at same location
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
LED Bulb 10 Watts
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required 2 x 10 Sqmm+ 1 x 10 Sqmm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required 2 x 6 Sqmm+ 1 x 6 Sqmm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required 2 x 4 Sqmm+ 1 x 4 Sqmm earth wire
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
SREE VINAYAKA ENTERPRISES
ARCHANA CONSTRUCTION CO
Mandhara Associates
ANAND REFRIGERATION
KUZHIKKAL ENTERPRISES
M/s A N Kalbhavi
H S S ENGINEERS AND CONTRACTORS
RAMESH BABU CO
Lucky Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .