| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LQualified III A 28 GF VAISHALI GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹49.9 L+₹19,666 (0.40%)Qualified OFFICE NO 8 SHD COMPLEX SHATABDI ENCLAVE SECTOR 49 NOIDA NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L2 | Qualified MII | |
| 3 | L3₹51.9 L+₹2.2 L (4.36%)Qualified 7 1 GF GADI SECTOR 121 GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L3 | Qualified MSE, MII, Category: General | |
| 4 | L4₹53.1 L+₹3.4 L (6.78%)Qualified 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L4 | Qualified MSE, MII, Category: General | |
| 5 | L5₹53.2 L+₹3.5 L (6.97%)Qualified NO 2333 TNHB KAKALLUR BYE PASS ROAD THIRUVALLUR TIRUVALLUR TAMIL NADU 602001 | THIRUVALLUR | TAMIL NADU | 602001 | L5 | Qualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
1 Jan 2025, 9:00 amClosed
C73340415177 Supply of high static pressure Ductable AC unit capacity not less than 16point5 TR
C73340415174 Supply of high static pressure Ductable AC unit capacity 8point5 TR
100000000001 Supply of suitable size refrigerant grade copper piping between indoor and outdoor units
100000000002 Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type
100000000003 Providing of cPVC SDR11 pipes 25 mm with 9 mm thick tube type
100000000004 Supply of site fabricated GI sheet metal ducts of 22 Guage Birmingham Gauge 0point80 mm and zinc coating not less than 120 gbym2
100000000005 Supply of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell
100000000006 Supply of wall mounted Electric control panel with incommer MCCB multimeter indication lamps including seperate MCCB unit for AC outdoor unit refer Annexure III
100000000007 Supply of XLPE insulated PVC sheathed armoured copper conductor 1point1 kV grade LT cable of size 4 core - 6 sqmm
100000000008 Supply of XLPE insulated PVC sheathed armoured copper conductor 1point1 kV grade LT cable of size 4 core - 10 sqmm
100000000009 Supply of XLPE insulated PVC sheathe copper conductor 1point1 kV grade LT cable of size 4point0 core - 2point5 sqmm
100000000010 Supply of perforated Hot Dipped Galvanised Iron cable tray of size 150 mm width X 50 mm depth X 1point6 mm thickness
100000000011 Installation testing and commissioning of high static pressure Ductable AC unit capacity not less than 16point5 TR
100000000012 Installation testing and commissioning of high static pressure Ductable AC unit capacity 8point5 TR
100000000013 Erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split AC units 8point5 TR
100000000014 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube
100000000015 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type
100000000016 Fabrication installation testing and commissioning of site fabricated GI sheet metal ducts of 22 Guage Birmingham Gauge 0point80 mm and zinc coating not less than 120 bym2
100000000017 Fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell
100000000018 Erection testing and commissioning of wall mounted Electric control panel with incommer MCCB multimeter indication lamps including seperate MCCB unit refer Annexure IV
100000000019 Laying of XLPE insulated PVC sheathed armoured copper conductor 1point1 kV grade LT cable of size 4 core - 6 sqmm
100000000020 Laying of XLPE insulated PVC sheathed armoured copper conductor 1point1 kV grade LT cable of size 4 core - 10 sqmm
100000000021 Laying of XLPE insulated PVC sheathed copper conductor 1point1 kV grade LT cable of size 4 core - 2point5 sqmm
100000000022 Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness
100000000023 Dismantling and shifting of existing ductable 9X16point5 TR and 5X8point5 TR including associated supports
7278952
GEM/2024/B/5733503
Two Packet Bid
C73340415177 Supply of high static pressure Ductable AC
45 days
Ghaziabad, Uttar Pradesh
Total value wise evaluation
BOQ
1 document required · 1 mandatory
Exempted
20 Dec 2024
20 Dec 2024
1 Jan 2025
SITC OF DUCTABLE AC
C73340415177 Supply of high static pressure Ductable AC unit capacity not less than 16point5 TR
C73340415174 Supply of high static pressure Ductable AC unit capacity 8point5 TR
100000000001 Supply of suitable size refrigerant grade copper piping between indoor and outdoor units
100000000002 Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type
100000000003 Providing of cPVC SDR11 pipes 25 mm with 9 mm thick tube type
100000000004 Supply of site fabricated GI sheet metal ducts of 22 Guage Birmingham Gauge 0point80 mm and zinc coating not less than 120 gbym2
100000000005 Supply of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell
100000000006 Supply of wall mounted Electric control panel with incommer MCCB multimeter indication lamps including seperate MCCB unit for AC outdoor unit refer Annexure III
100000000007 Supply of XLPE insulated PVC sheathed armoured copper conductor 1point1 kV grade LT cable of size 4 core - 6 sqmm
100000000008 Supply of XLPE insulated PVC sheathed armoured copper conductor 1point1 kV grade LT cable of size 4 core - 10 sqmm
100000000009 Supply of XLPE insulated PVC sheathe copper conductor 1point1 kV grade LT cable of size 4point0 core - 2point5 sqmm
100000000010 Supply of perforated Hot Dipped Galvanised Iron cable tray of size 150 mm width X 50 mm depth X 1point6 mm thickness
100000000011 Installation testing and commissioning of high static pressure Ductable AC unit capacity not less than 16point5 TR
100000000012 Installation testing and commissioning of high static pressure Ductable AC unit capacity 8point5 TR
100000000013 Erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split AC units 8point5 TR
100000000014 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube
100000000015 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type
100000000016 Fabrication installation testing and commissioning of site fabricated GI sheet metal ducts of 22 Guage Birmingham Gauge 0point80 mm and zinc coating not less than 120 bym2
100000000017 Fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell
100000000018 Erection testing and commissioning of wall mounted Electric control panel with incommer MCCB multimeter indication lamps including seperate MCCB unit refer Annexure IV
100000000019 Laying of XLPE insulated PVC sheathed armoured copper conductor 1point1 kV grade LT cable of size 4 core - 6 sqmm
100000000020 Laying of XLPE insulated PVC sheathed armoured copper conductor 1point1 kV grade LT cable of size 4 core - 10 sqmm
100000000021 Laying of XLPE insulated PVC sheathed copper conductor 1point1 kV grade LT cable of size 4 core - 2point5 sqmm
100000000022 Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness
100000000023 Dismantling and shifting of existing ductable 9X16point5 TR and 5X8point5 TR including associated supports
Ductable Ac Bid Details 2/21
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_7278952.pdf
GEM_BID
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
techspecsac_2024-12-20-13-21-56_ea04dacf1a69df548c7fe12112b6858d.pdf
BOQ
boq_item_sample_file_ac_2024-12-20-13-21-56_222d3f089cf9813fc3095d778f4c45db.csv.pdf
BOQ
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .