| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.3 L+₹49,064.50 (1.50%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹34.9 L+₹2.1 L (6.45%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹36.4 L+₹3.7 L (11.2%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹36.5 L+₹3.7 L (11.3%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
23 Jul 2022, 6:00 pmClosed
GE (UTILITIES) UDHAMPUR
GE (UTILITIES) UDHAMPUR PO-GARHI, PIN-182121
Repair /Replacement of LT Panel boards and connected Electrical Infrastructure Spares Under GE(Utilities) Udhampur.
2022_MES_524245_2
GE/U-20/22022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹80,000
Yes
5 Aug 2022
25 Jun 2022
25 Jul 2022
25 Jun 2022
23 Jul 2022
16 Jul 2022
Amount
Taking out the existing unserviceable LT Panel and Supply , installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments:- (a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 amps for Phases and neutral - 01 set.
(b) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job. (c) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos. Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 300/320 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. Outgoing:- (a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos. (b) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos.
Taking out the existing unserviceable LT Panel and Supply , installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel.Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :- (a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 500 amps for Phases and neutral - 01 set.
(b) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job. (c) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos. Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. Outgoing:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. (b) MCCB 4 pole ,Ics=100%Icu- 26 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. (c) MCCB 4 pole ,Ics=100%Icu- 26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos.
Taking out the existing unserviceable LT Panel and Supply , installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :- (a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 1000 amps for Phases and neutral - 01 set.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Taking out the existing unserviceable LT Panel and Supply , installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :- (a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 1000 amps for Phases and neutral - 01 set.
Taking down old unservicable over head aluminium conductor of any size and type complete all specified and directed by Engr-in-Charge.
XLPE insulated, armoured, aluminium conductor cable of sizes 240 sqmm 3.5 core, 1100 volts grade, heavy duty ,laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge:- Make:-Havells/Polycab/Gloster/Grandley/KEI
All as per serial item No 7.00 here-in-before but size 150 sqmm 3.5core.
All as per serial item No 7.00 here-in-before but size 95 sqmm 3.5 core.
All as per serial item No 7.00 here-in-before but size 50 sqmm 3.5 core.
All as per serial item No 7.00 here-in-before but size 25 sqmm 4 core.
All as per serial item No 7.00 here-in-before but size 16 sqmm 4 core.
PVC insulated multi stranded aluminium conductor (in replacement) PVC cable sheathed 6 sqmm twincore and making connections of street light fittings from UG cable complete all as specified and directed by Engr-in-Charge. Make : Plaza/Paragon/kalinga.
PVC insulated two core 1.5 sqmm multi standard copper conductor cable from junction box to light fittings complete all as specified and directed by Engr-in-Charge.
Factory made sheet metal enclouser (junction box) made out 3.15mm CRCA sheet powder coated, weather proof, out door type (in replacement) with 60cm long legs 04 nos made out of angle iron of size 40x40x6 mm equal angle, size of enclouser not less then 75x60x30 cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of rating 800 amps suitable for 1 incoming and 3 out going feeders, mounted on insulators including necessary thimbles/lugs of suitable sizes, necessary earth work and PCC foundation for grouting of four legs complete all as specified and directed by Engr-in-Charge.
Modular box made of FRP impact resistance plastic & heat resistant materials of suitable size to accommodate the fixtures with IP65 including connector terminal block 4 pole and 25A SPN suitable for fixing cable connection and fixing to pole with suitable nuts, bolts complete all as specified and directed by Engr-in-Charge.
Modular box made of FRP impact resistance plastic & heat resistantance including aluminium Bus Bar of capacity 50 Amps 3 phase 1 Neutral connector terminal complete all as specified and directed by Engr-in-Charge. Note:- The modular box must be including necessary arangement for fixing of MCBs.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying /repair to pipe line and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, excavated soil including spreading levelling ,watering and well running in layers not exceeding 25cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavated soil to a distance n. exc 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed by Engr-in-Charge.
Ornamental 10 Watt LED Retrofit Garden Light bollard having height of 1m from base and width of 30cm made out of die cast aluminium/cast iron, elegant look, duly primer and painted antique colour finish complete all as specified and directed by Engr-in-Charge. Make : - HI-Lite model No HL-138 or equivalent in Havells/polycab/Bajaj.
LED bollard lights of 10/11 Watt capacity, IP-65 rated inverted pyramid tripod type with soft 360 degree light distribution complete all as specified and direceted by Engr-in-Charge. Make: - Crompton Cat part No - LBLSN-10-CDLor equivalent in Polycab/Havells. Note :- Necessary grouting for fixing of bollard must be included in the quoted rated by the contractor.
LED post top with powder coated aluminimum die cast and spun with clear/opal diffuser, suitable for landscape lightning and should have 5700k CCT, IP65 60 Watt excellent heat dissipation for long life complete all as specified and directed by Engr-in-Charge. Make : Polycab Cat part No - PGR0201012 or equivalent in Havells/Crompton.
GI tubing light grade, 50mm bore including necessary clamps for the protection of the cable, laid in trenches/under road/path complete all as specified and directed by Engr-in-Charge.
Focus light of capacity 18/15 Watt environmental friendly, new generation, energy saving, decorative spike light for architectural and monument lightning complete all as specified and direceted by Engr-in-Chare. Make:- Havells/Phillps/Crompton/Polycab/Wipro.
Double walled corrugated pipe (DWC) of size 120/103 mm for cable of size 240 sqmm,150 sqmm & 95 sqmm with necessary Snap fit Coupler complete all as specified and directed by Engr-in-Charge. Make:- Rex Polyxtrusion Pvt. Ltd/Tirupati/Supreme.
Double walled corrugated pipe (DWC) of size 90/76 mm for cable of size 50 sqmm with necessary Snap fit Coupler complete all as specified and directed by Engr-in-Charge. Make:- Rex Polyxtrusion Pvt. Ltd/Tirupati/Supreme.
Double walled corrugated pipe (DWC) of size 77/63 mm for cable of size 25 sqmm with necessary Snap fit Coupler complete all as specified and directed by Engr-in-Charge. Make:- Rex Polyxtrusion Pvt. Ltd/Tirupati/Supreme.
Double walled corrugated pipe (DWC) of size 40/32 mm conforming to IS: 14930/IS 16205 for protection of LT cable for cable of size 16sqmm with necessary Snap fit Coupler complete all as specified and directed by Engr-in-Charge. Make:- Rex Polyxtrusion Pvt. Ltd/Tirupati/Supreme.
vijay kumar gupta and co
K S BUILDERS
MOHAN LAL AND SONS
kailu construction co
D P ASSOCIATES
FANGALIA TRADERS
slathia construction works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .