Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.8 LAccepted-AOC HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹45.8 L+₹1.3 L (2.99%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
7 Oct 2021, 6:00 pmClosed
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
86490E8 SPECIAL REPAIRS TO BLDG NO 40 25 AND 27 AT OTA UNDER GE STM CHENNAI.
2021_MES_471841_1
86490E8
Open Tender
Civil Works
Item Rate
180 days
GE STM CHENNAI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE STM CHENNAI
₹84,000
Yes
31 Dec 2021
31 Aug 2021
14 Oct 2021
31 Aug 2021
7 Oct 2021
25 Sept 2021
31 Aug 2021 - 7 Sept 2021
Amount
REVISED BOQ UPLOADED ON 21 SEP 2021, BOQ UPLOADED ON 31 AUG 2021 CANCELLED
SCH "A" (CIVIL WORKS)
Taking down chowkats or frames (wooden / steel) with shutters (without taking off shutters from the frames) exceeding 1.50 sqm but not exceeding 4.00 sqm each and removing from site under Sch of credit complete all as specified and as directed.
Taking down chowkats or frames (wooden / steel) with shutters (without taking off shutters from the frames) not exceeding 1.50 sqm each and removing from site under Sch of credit complete all as specified and as directed.
Taking down cement plaster any description on brick or stone walls, concrete surfaces, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removal of unserviceable debris to outside of MD land complete all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal from site under Sch of credit of bore of pipe 15mm complete all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal from site under Sch of credit of bore of pipe 20mm complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 150mm thickness (below or above ground level) and and removal of unserviceable debris to a distance not exceeding 100m complete all as specified and as directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar, including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles and removal of unserviceable debris to a distance not exceeding 100m complete all as specified and as directed.
Demolition of stone slabs / tiles of any description or thickness in floors or vertical surfaces, as in ceramic tiles laid, bedded and pointed in any mortar including bedding screed and backing in vertical surfaces and removal of unserviceable debris to outside of MD land complete all as specified and as directed.
Dismantling of stone slabs / tiles of any description or thickness in floors or vertical surfaces, laid, bedded and pointed in any mortar including bedding screed and backing in vertical surfaces and removal of unserviceable debris to outside of MD land complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc.,) or insulation boards / slabs / blankets any thickness including cover fillets and framework and removing from site under Sch of credit complete all as specified and as directed.
BLANK
Dismantling timber scantlings 40 sqcm and over in section in framed work in any position and taken on credit complete all as specified and as directed.
Dismantling of battens for tiles, shingles etc, of any size including tilting fillets spaced exceeding 150mm complete all as specified and as directed.
Dismantling of single layer Mangalore pattern or similar tiles in roofing complete all as specified and as directed.
Plain cement concrete, type B1, 1:2:4, using 20mm graded stone aggregate as in copings, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and as directed.
Reinforced cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Reinforced cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate as in beams, lintels over 1.5m span complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Supply only Liquid Water proofing compound all as specified and as directed.
Brickwork with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of designation 50 complete all as specified and as directed.
Forming jambs, etc. to openings in CM 1:4, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slabs like raised platform slab and similar work not exceeding 200mm thick (horizontal or sloping), flat with rough finished surface of concrete complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor / roof beams and similar items including edges rough finished surfaces of concrete complete all as specified and as directed.
Timber as Second class hardwood in scantlings, clean sawn framed and fixed complete all as specified and as directed.
Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, as in IInd class hardwood complete all as specified and as directed.
Factory made Glazed and skeleton shutters, of IInd class hardwood, 30mm thick open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, with plain, chamfered or rounded. mitred and rebated sash bars for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b) complete all as specified and as directed.
Glass or wire cloth as required shall be measured and paid separately.
Factory made Glazed and skeleton shutters, of IInd class hardwood, 35mm thick open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, divided into squares, with plain, chamfered or rounded. mitred and rebated sash bars for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and as directed.
Glass or wire cloth as required shall be measured and paid separately.
Factory made plain, framed, panelled shutters (any number of panels), of IInd class hardwood, 35mm thick with panels of wood particle board with commercial face veneers complete all as specified and as directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as per relevant drawing in SSR Part-II complete all as specified and as directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixed in frames as per relevant drawing in SSR Part-II complete all as specified and as directed.
Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 200mm complete all as specified and as directed.
Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 125mm complete all as specified and as directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, length of bolt 300mm complete all as specified and as directed.
Butt hinges, extruded aluminium alloy, with mild steel hinge pin, anodised, type C-21 of size 75mm complete all as specified and as directed.
Butt hinges, extruded aluminium alloy, with mild steel hinge pin, anodised, type C-21 of size 100mm complete all as specified and as directed.
Butt hinges, stainless steel, with stainless steel hinge pin and fixed to frame of size 100mm complete all as specified and as directed.
Ordinary rat tail rod pattern springs, 300mm, mild steel, including roller and roller plate as in repairs complete all as specified and as directed.
Extruded aluminium alloy handles, fabricated type, anodised of size 150mm complete all as specified and as directed.
Extruded aluminium alloy handles, fabricated type, anodised of size 125mm complete all as specified and as directed.
Tubular towel rail, brass chromium plated, 20mm dia, D type, 600mm long between flanges complete all as specified and as directed.
Aluminium (die cast) body door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples as in repairs complete all as specified and as directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Mild steel as in framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors and similar work conforming to Fe-290, Gde-E-65 complete all as specified and as directed.
Mild steel as in small articles such as hold fast and like conforming to Fe-290 Grade-E-165 complete all as specified and as directed.
Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed.
Mild steel TMT bars but 5mm dia and over upto and including 10mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers & binders complete all as specified and as directed.
Welding in repairs of metal not exceeding 25mm in length and thickness of metal to be welded not exceeding 6mm thick complete all as specified and as directed.
Aluminium frame for doors, windows, ventilators with one or more rebates including ioining cleat for fixing etc. powder coated to minimum 50 micron thickness complete all as specified and as directed.
Aluminium sections powder coated to minimum 50 micron thickness as in styles and rails and handle of aluminium door / window shutters, except fixing complete all as specified and as directed.
(a) Rubber packing, screws etc. as required shall be measured fixing of shutters.
(b) Glass or wire cloth as required shall be measured and paid separately.
Fixing only aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary ioining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, and provision of anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21, 100mm long (2 Nos.), suitable handle (1 No.) , aluminum tower bolt 125mm (02 Nos) etc., complete all as specified and as directed.
(a) All aluminium sections including snap beading, joining cleats, glazing cilps etc. shall be measured under aluminium shutters separately as supply only.
(b) Glass or wire cloth as required shall be measured and paid separately.
(c) The fixtures given are for shutter of approximate size 0.50m x 1.50m.
Aluminium grill (dyed to required shade according to IS-1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to existing window frame with CP brass / stainless steel screws at 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium section around the opening , complete all as specified and as directed.
Aluminium sliding windows, powder coated to minimum 50 micron thickness all as given here-in-after complete all as specified and as directed. Frame:- Three track section shall be of weight not less than 1.060 kg/m. Shutter:- Consists of 03 Nos Shutters i.e 02 Nos od Glazed shutters and 01 No of Gauzed shutter. Sections of shutter (stiles and rails) sections shall be of weight not less than 0.562 kg/m. Builders hardware:- Standard locking device for glazed shutters.
(a) All aluminium sections including glazing clips, snap beading, joining cleats, rubber packing, screws etc., as required are deemed to be included in the rate quoted.
(b) Glass or wire cloth as required shall be measured and paid separately.
(c) The fixtures given are for window unit of size exceeding 1.0 sqm but not exceeding 2.20 sqm.
False ceiling of tiles of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanised at 120 grams / sqm, both sides inclusive), consisting of main "T" runner, cross tees, secondary cross tees and wall angles and laying light weight calcium silicate false ceiling tiles of approved texture in the grid including required cutting / making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., complete all as specified and as directed.
The item shall be read in conjunction with detailed particular specifications given here-in-after and the rate quoted is deemed to include for all the provisions given therein.
Aluminium snap grid framework (powder coating of minimum 50 microns) of grid size 605mm x 605mm of main and cross tee of size 40mm x 25mm x 1.5mm thick and wall angle size 25mm x 25mm x 1.5mm thick for false ceiling including fixing of supporting hangers complete all as specified and as directed.
The hangers for support of false ceiling shall be measured and paid separately.
Anodised aluminium snap grid of size 605mm x 605mm frame work for false ceiling but fixing only all as specified
The materials required such as aluminium sections and hangers for support of false ceiling as retrieved from dismantling shall be reused.
Hangers 6 mm dia. G.I. (hanging depth as per site condition) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long at intervals as per manufacturers instructions complete all as specified and as directed.
Prelaminated particle board minimum 9mm thick, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination for insulation purpose fixed with staples on snap grid ceiling complete all as specified and as directed.
Particle board any thickness for insulation purpose fixed with staples on snap grid ceiling but except sheeting complete all as specified and as directed.
The boards as retrieved from dismantling shall be reused.
Prelaminated particle board minimum 12mm thick, exterior grade, one side prelaminated with decorative choice lamination and other side balancing white fixed with screws to timber framework including lipping with teakwood 6mm thick fixed with nails complete all as specified and as directed.
Prelaminated particle board minimum 9mm thick, exterior grade, one side prelaminated with decorative choice lamination and other side balancing white fixed with screws to timber framework including lipping with teakwood 6mm thick fixed with nails complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry at the rate of 3.0kg of cement per square metre complete all as specified and as directed.
Plain cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate, 50mm thick as in floor, finished fair and even complete all as specified and as directed.
Plain cement concrete 75mm thick, 1:3:6, type C1, using 20mm graded stone aggregate as in plinth protection / foot path / hardstanding, surface finished fair and even complete all as specified and as directed.
Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeeding 0.11 sqm (300mm x 300mm), in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / sqm complete all as specified and as directed.
Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeeding 0.38 sqm (600mm x 600mm), in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / sqm complete all as specified and as directed.
Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / sqm complete all as specified and as directed.
Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeeding 0.11 sqm, (600mm x 150mm) in vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed.
Glazed ceramic tiles of grade B-III coloured of size 350mm x 250mm / 450mm x 350mm, minimum 7mm thick in vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed.
Chequered cement concrete tiles with grey cement and pigment of size 200mm x 200mm x 25mm thick set, jointed and pointed in neat cement slurry at the rate of 4.20 kg / sqm in floors laid over cement screed in CM 1:4, 20mm thick complete all as specified and as directed.
Machine cut, polished, kota stone slab flooring as in staircase treads, landing etc., 20-25mm thick laid over cement screed base in CM 1:3, 20mm thick, laid and jointed with grey cement slurry at the rate of 4 kg per sqm, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Machine cut, polished, kota stone slab flooring as in risers of steps. skirting, dado and pillar , 20-25mm thick laid over backing coat in CM 1:3, 20mm thick, laid and jointed with grey cement paste, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Granite (of any type) work, of thickness 18mm to 20mm, (table rubbed and polished) in wash basin platforms, cooking platforms, steps, jambs, pillars, windows and the like set in cement mortar 1:4, 20mm thick, including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite stone complete all as specified and as directed.
Rendering 15mm thick in CM(1:6) on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 10mm thick in CM(1:6) with a top coat of rendering 5mm thick in CM(1:4) mixed with liquid water proofing compound on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Preparing old plastered surfaces of wall and applying two coats of white wash on plastered wall surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed.
Preparing newly plastered surfaces of wall,, applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed
Complete removal of existing treatment from wall surfaces, applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed
Preparing newly plastered surfaces of wall, applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over a coat of alkali resistant priming paint, complete all as specified and as directed
Complete removal of existing treatment from wall surfaces, applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over a coat of alkali resistant priming paint over wall care putty 3mm thick, complete all as specified and as directed
Sheet glass, 4mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Plain fillets of IInd class hardwood, rectangular or triangular in section, not exceeding 3 sqcm, clean sawn, secured with nails or brads complete all as specified and as directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in ends of posts, backs of chowkats etc., area exceeding 0.10 sqm but not exceeding 0.50 sqm each and treated with tar or coal tar black paint and sanding complete all as specified and as directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in small articles such as stop, covers, gully gratings, hold fasts etc., , area not exceeding 0.10 sqm each and treated with tar or coal tar black paint and sanding complete all as specified and as directed.
Preparing new surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparing old painted surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Preparing old painted surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Steel tubing, galvanised, medium grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls and ceilings or laid in floors of bore of pipe 15mm complete all as specified and as directed.
Steel tubing, galvanised, medium grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls and ceilings or laid in floors of bore of pipe 20mm complete all as specified and as directed.
Dismantling existing water tanks, exceeding 500 litres and not exceeding 1000 litres, lowering and taken on charge on credit and provision of rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) , three layered hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 litres complete all as specified and as directed.
Gun metal, globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed of bore of pipe 25mm as in repairs complete all as specified and as directed.
Gun metal, globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed of bore of pipe 20mm as in repairs complete all as specified and as directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed both ends for iron pipe or brass ferrule and fixed, of bore of pipe 25mm complete all as specified and as directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed both ends for iron pipe or brass ferrule and fixed, of bore of pipe 20mm complete all as specified and as directed.
Bib taps, cast copper alloy, chromium plated, with flange, with crutch or butterfly handle, screwed down, screwed both ends for iron pipe or for brass ferrule and fixed of bore of pipe 15mm complete all as specified and as directed.
Make shall be of Prayag Cat No. Neptune Series PIS-06 or equivalent of makes listed here-in-after.
Stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore of pipe 15mm as in repairs complete all as specified and as directed.
Angle valves, fancy type, chromium plated, with flange, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore of pipe 15mm complete all as specified and as directed.
Make shall be of Prayag Cat No. Neptune Series PIS-10 or equivalent of makes listed here-in-after.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of bore 110mm as in repairs complete all as specified and as directed.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of bore 75mm as in repairs complete all as specified and as directed.
PVC (SWR) bend any radius of bore 75mm complete all as specified and as directed.
PVC (SWR) bend any radius of bore 110mm complete all as specified and as directed.
Vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) and including fixing of the following components viz. pedestal pan with "P" or "S" trap, seat and cover for pedestal pan, flushing cistern, brackets, chain and pull or lever handle, flushing pipe including jointing to socket of flushing rim and connecting pipe to union of flushing cistern, inlet and overflow pipe, anti-syphonage pipe or stopper fixed as in repairs complete all as specified and as directed.
Flushing cistern, flush pipe, seat cover, P trap, WC connector, as required shall be measured and paid for under supply only separately.
Vitreous china squatting pan, "Orissa" pattern, size 580mm x 440mm white, with integral foot rests (excluding flushing cistern and flush pipe) and including fixing of the following components viz. squatt pattern pan with loose cast iron or vitreous chinaware, "P" or "S" trap, seat, flushing cistern, brackets, chain and pull or lever handle, flushing pipe including jointing to socket of flushing rim and connecting pipe to union of flushing cistern, inlet and overflow pipe, anti-syphonage pipe or stopper, setting the trap in and pan in lime concrete, 150mm minimum thickness and finished just below level of rim of pan to receive floor finishing as in repairs complete all as specified and as directed.
Flushing cistern and flush pipe as required shall be measured and paid for under supply only separately.
Supply only PVC valveless, syphonic action type flushing cistern 10 litres capacity low level, white with inlet, ball valve, float and handle / push button, including brackets complete all as specified and as directed.
Supply only flush pipe of polyethylene of high density, 32mm dia for low level / high level flushing cistern complete all as specified and as directed.
Supply only of plastic water closet seat, white, complete all as specified and as directed.
Make shall be of Prayag Cat No. 513, Standard Series or equivalent of makes listed here-in-after.
PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
Vitreous china wash basin, white, flat back, size 550mm x 400mm excluding taps, waste fitting, but including brackets and including fixing of the following components viz. pillar taps, waste fittings and union, plugs and chains and connecting upto supply pipes, wastes or traps, screws, plugs, cement mortar and other subsidary materials required for fixing including cutting for and pinning in ends of brackets but exclusive of fixing of supply and waste pipe as in repairs complete all as specified and as directed.
(a) Pillar taps and waste fittings as required shall be measured and paid for under supply only separately.
(b) Supply and waste pipes as required shall be measured and paid for separately.
Supply only pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed of bore of pipe 15mm complete all as specified and as directed.
Make shall be of Prayag Cat No. Neptune Series PIS-02 or equivalent of makes listed here-in-after.
Supply only waste fittings, brass, chromium plated for glazed ware basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed of bore of pipe 32mm complete all as specified and as directed.
Make shall be of Prayag Cat No. Droplet Series BEA-10S or equivalent of makes listed here-in-after.
LDPE pipes, 32mm bore of pipe, of pressure rating 6 kgf/sqcm with polyethylene thread union and check nuts, fixed to walls as in waste pipe in wash basin as in repairs complete all as specified and as directed.
PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
PVC connections 15mm size with PTMT nuts of length 450mm as in repairs complete all as specified and as directed.
Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections for bore of trap 40mm including necessary packing, union and cap and fixed as in repairs complete all as specified and as directed.
Make shall be of Prayag Cat No. BEA-21/7" or equivalent of makes listed here-in-after.
PVC (SWR) floor trap, plain with grating of diameter of outlet 75mm including jointing with solvent cement as in repairs complete all as specified and as directed.
PVC (SWR) floor trap, plain with grating of diameter of outlet 110mm including jointing with solvent cement as in repairs complete all as specified and as directed.
PVC (SWR) vent cowl of bore 110mm complete all as specified and as directed.
Stainless steel sink with drainage board, 1mm thick, for kitchen, with plugs, waste pipe, waste fittings, washers, including bedding in cement mortar 1:4 on dwarf walls or fixing on and including cantilever cast iron brackets, connecting union to pipe etc., overall size 915mm x 460mm with bowl size 410mm x 330mm x 200mm (size approximate) as in repairs complete all as specified and as directed.
Make shall be of Prayag Cat No. 1239DM matt finish or equivalent of makes listed here-in-after.
Brass Chromium plated shower rose 100mm size with or without swivel joints, arm including fixing to steel pipe or union complete all as specified and as directed.
Make shall be of Prayag Cat No. Cascade Series BOS-32 (Shower) and BOS-47 (Arm) or equivalent of makes listed here-in-after.
Aluminium designer curtain rods (draw berms rod) exterior grade 3mm thick with holding clamps and fixed to wall with rawl plugs and brass screw including dismantling existing curtain rod including brackets any type complete all as specified and as directed.
Aluminium designer curtain rods brackets suitable for rods as described above complete all as specified and as directed.
Wash basin mixer brass, chromium plated, for shower for mixing of hot and cold water screwed for iron pipe. bore of pipe 15mm as in repairs complete all as specified and as directed.
Make shall be of Jaquar Cat No.CON-CHR-169KNB or equivalent of makes listed here-in-after.
Health faucet, chromium plated, 2 in 1, suitable for 15mm bore of pipe with SS tube length 1000mm, wall hook, water shower gun, washers, connections, brass union etc., as in repairs complete all as specified and as directed.
Make shall be of Prayag Cat No. BEA-97 or equivalent of makes listed here-in-after.
Toilet paper holder brass, chromium plated, fixed to walls with chromium plated brass screws complete all as specified and as directed.
Make shall be of Jaquar Cat No.ACN-CHR-1151N or equivalent of makes listed here-in-after.
Corner glass shelf including bracket and fittings, matt finish chromium plated (MCH / Colour CP), fixed to walls with chromium plated brass screws complete all as specified and as directed.
Make shall be of Jaquar Cat No. ACH-CHR-1173 or equivalent of makes listed here-in-after.
Towel rack with lower hanger of stainless steel fixed to walls with chromium plated brass screws as in repairs complete all as specified and as directed.
Make shall be of Jaquar Cat No.AHS-CHR-1581H or equivalent of makes listed here-in-after.
Wall mixer brass, 3-in-1, chromium plated, for shower for mixing of hot and cold water screwed for iron pipe. bore of pipe 15mm as in repairs complete all as specified and as directed.
Make shall be of Jaquar Cat No.CON-CHR-281 KN or equivalent of makes listed here-in-after.
Stainless steel rack kitchen plate rack size 910mm x 780mm x 250mm, with screws and necessary fittings including making holes to fix to walls complete all as specified and as directed.
Make shall be of Prayag Cat No.P-348 or equivalent of makes listed here-in-after.
SCH "A" PART-II (INTERNAL ELECTRIFICATION)
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, etc., and separating the serviceable items for reuse, removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated 1100 volts grade unsheathed cable FRLS confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed on surface with suitable clamps on ceiling etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor cable FRLS green in colour as earth continuity conductor and connected to common earth dolly, metal flush box and cover plate with frame for suitable number of modules flush mounted and concealed in walls for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for one light point controlled by one switch.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.135 here-in-before but for one ceiling fan point controlled by one switch and regulator
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.135 here-in-before but for one exhaust fan point controlled by one switch.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.135 here-in-before but for One switch socket outlet point 3 pin 5 Amps on same board with other switches.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.135 here-in-before but for One switch socket outlet point 3 pin 5 Amps on independent board.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.135 here-in-before but for One bell / buzzer point controlled by one bell push
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.135 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
Taking down carefully unserviceable sub-main wiring and provision of Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 4.0 sqmm FRLSH conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 4.0 sqmm PVC insulated single core multistranded copper conductor cable FRLSH (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
(a) Two runs of 4 sqmm cable and one run of 4 sqmm cable and one run of conduit will be measured as one length.
(b) Cutting chases on walls for concealing pipes and cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring.
Modular switch, one way, 6 Amps, one module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 00 or equivalent of makes as listed here-in-after.
Modular switch, one way, 16 Amps, one module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 08 or equivalent of makes as listed here-in-after.
Modular socket outlet, 6A-2/3 pin combined, two module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 44 or equivalent of makes as listed here-in-after.
Modular socket outlet, 6A / 16A-2/3 pin combined, two module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 45 or equivalent of makes as listed here-in-after.
Modular Bell push, flush type, 5 Amps complete all as specified and as directed.
Make shall be of Legrand Cat No. 5734 13 or equivalent of makes as listed here-in-after.
Metal flush box in any number of combinations as required complete all as specified and as directed.
The rate shall be quoted on per module basis irrespective of the number of modules in the combination.
White cover plate with frame in any number of combinations as required complete all as specified and as directed.
The rate shall be quoted on per module basis irrespective of the number of modules in the combination.
Modular Fan step regulator, 120 W, 250V, two module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 28 or equivalent of makes as listed here-in-after.
Ceiling rose, 3 terminal, PVC / polycarbonate, insulated body complete as specified and as directed.
Bell, ding dong type, AC, 230 Volts, single pole complete all as specified and as directed.
Lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Isolator 63 Amps, TPN, 415 Volts, 50 Hz, AC supply,with breaking capacity of 10 kA complete all as specified and as directed.
Isolator 40 Amps, DP, 230 Volts, 50 Hz, AC supply,with breaking capacity of 10 kA complete all as specified and as directed.
MCB 6-32 Amps, SP, 240 Volts, 50 Hz, AC supply, "C" curve, with breaking capacity of 10 kA complete all as specified and as directed.
MCCB 160 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz, 16 kA breaking capacity, with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 100% of Icu having spreader links and barriers as standard feature of manufacturer as in repairs complete all as specified and as directed.
Sheet metal enclosures with socket plug top and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 10 Amps, 10 kA, 240 V as in repairs complete all as specified and as directed.
Taking down MCB DB including inner components and provision of MCB DB TPN 4 way, vertical, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for MCCB FP, 160 Amps, as incomer and MCB SP as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed.
MCCB and MCB as required shall be measured and paid separately.
Taking down MCB DB including inner components and provision of MCB DB SPN 8 way, single door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and DP / SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed.
MCB as required shall be measured and paid separately.
Taking down MCB DB including inner components and provision of MCB DB SPN 12 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed.
MCB as required shall be measured and paid separately.
Taking down MCB DB including inner components and provision of MCB DB SPN 4 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed.
MCB as required shall be measured and paid separately.
Taking down and dismanting old ceiling fan and provision of energy saving ceiling fan 1200mm sweep, double ball bearing type, opal white colour, with suitable down rod, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan complete all as specified and as directed.
(a) Make shall be of Havells Cat No.Efficiencia Neo or equivalent of makes as listed here-in-after.
(b) The old ceiling fan shall be deposited in the MES store yard of AGE E/M STM.
Taking down old model heavy exhaust fan, sealing cable end and removing fan to store and provision of exhaust fan, heavy duty, 300mm sweep, 900 RPM, with louvers, metal body conforming to IS-2312-1967, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing and fixing arrangements like making hole in wall and finishing to shape to match adjoining surface and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed.
(a) Make shall be of Havells Cat No.Turbo Force SP or equivalent of makes as listed here-in-after.
(b) The old exhaust fan shall be deposited in the MES store yard of AGE E/M STM.
LED batten fitting 20 W, 230 V, extruded aluminium housing provided for easy heat dissipation wall mounted complete pre wired and including tube and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed.
(a) Make shall be Havells Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after.
LED batten fitting 10 W, 230 V, extruded aluminium housing provided for easy heat dissipation wall mounted complete pre wired and including tube and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed.
(a) Make shall be Havells Cat No. LUMILINEPLUSBS10WLED865SPCSS or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after.
Surface mounted, LED flat panel, 42W, 2 x 2, luminaire, 230 V, pre wired including driver connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire complete all as specified and as directed.
(a) Make shall be Havells Cat No.VENUSNEOHE2X2PLR18-42WLED857MOD plus suitable driver or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after.
LED building security light fitting 30W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5m bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed.
(a) Make shall be as Havells Cat No. ENDURAPEARLSL30WLED757SASYTOPCMP under or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
Trivector DLMS, three phase compliance of accuracy class 1.0, 3 x 240 V, 50 Hz with backlit LCD display of rating 10 - 60 A (Measure and display trivector V, I, kW, PF, Hz, last month historic of kWH and MD in kW) with special features like TOD, tamper logging, optical communication port and display in the absence of power including necessary electrical connection complete all as specified and as directed.
Taking down existing geyser and provision of geyser 25 litres capacity, 5 star rating including all fittings and fixtures , nuts, bolts and connecting in the same position ,complete all as specified and as directed.
(a) Make shall be of Havells Cat No.MONZA EC GHWAMFSWH025 or equivalent of makes as listed here-in-after.
(b) The old geyser shall be deposited in the MES store yard of AGE E/M STM.
Taking down ceiling fan any sweep, dismantling and opening up, replacing bearings, bushes, condensors of same existing type and capacity, greasing, assembling back, painting of fans complete, with synthetic enamel paint by spraying including filling cavities with filler, coat after cleaning all dust, dirt, grease, etc., testing and writing MES No.20mm height with synthetic enamel paint black and hanging back in position with all accessories and connecting including 1.5 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing complete all as specified and as directed.
Taking out existing earthing materials and provision of earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
SCH "A" PART-III (EXTERNAL ELECTRIFICATION)
Taking out existing cable any type / cross section and provision of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments of the following sizes complete all as specified and as directed.
Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(a) 3.5 core, cross sectional area 50 sqmm
(b) 4 core, cross sectional area 25 sqmm
(c) 2 core, cross sectional area 6 sqmm
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under fllor / / under roads / crossings etc., of bore of pipe 50mm for cable protection complete all as specified and as directed.
Earthwork as required shall be measured and paid separately.
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls / poles etc., of bore of pipe 50mm for cable protection complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil all as specified and as directed.
Earthwork is deemed to be carried out by manual method. However mechanised method may be adopted without any extra cost to the government.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Dry river sand laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
Punned thickness only shall be measured.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Common burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection complete all as specified and as directed.
Post top landscape luminaire, 25 Watts, new generation, energy saving, environmental friendly, with symetrically light distribution spun aluminium with high power LED as light source and connecting up complete all as specified and as directed.
(a) Make shall be as Havells Cat No. RUBYPT25WLED757PSYMTOPC under or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
Sheet moulded compound (SMC) box, weather proof type, hinged door, off white colour of size 240mm x 130mm x 110mm comprising MCB SP 6 Amps, 10 kA - 01 No and Neutral link - 01 No fixed on pole with suitable clamps, bolts and nuts duly painted complete all as specified and as directed.
Cutting existing bituminous / concrete road surfaces to a depth not more than 150mm, and making good the surface with PCC 1:3:6, type C1, using 20mm graded stone aggregate to match to the adjacent surface after laying pipes / cable including removal of debris to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Cubical content of PCC shall be measured.
RAJASEKARAN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .