Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.2 L+₹2.3 L (11.3%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹23.5 L+₹3.5 L (17.6%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹23.7 L+₹3.7 L (18.4%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹23.9 L+₹3.9 L (19.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
26 Jul 2022, 6:00 pmClosed
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
SPL REPAIR TO BLDG NO P-15 UNDER ZONE-I AND PROVN OF COVER SHED AT P-06, ROOF TREATMENT TO BLDG NO. P-168, P-174 AND P-175 UNDER ZONE -II AREA AT JAIPUR MIL STN
2022_MES_533751_1
GE/J-18/2022-23
Open Tender
Civil Works
Item Rate
180 days
JAIPUR
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹43,000
Yes
22 Aug 2022
25 Jun 2022
28 Jul 2022
25 Jun 2022
26 Jul 2022
8 Jul 2022
25 Jun 2022 - 7 Jul 2022
Amount
Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in concrete, including taking out embedded portion and making good disturbed ground
M&L Cement concrete in foundations, filling and mass-concrete in PCC 1:2:4Type B-2 (using 40 mm graded stone aggregate).
Dismantling wrought iron or mild steel work of any description nototherwise provided complete all as directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over red oxide primer exc 10 CM in width or girth complete all as directed.
Demolition of cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level) complete all as directed.
M & L for plain Cement Concrete 1:4:8 type D-2 (40mm graded aggregate) in foundation filling mass concreting and in sub base floor complete all as directed.
Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in cement mortar complete all as directed
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement laid over and including 25 mm thick sand cushion layer complete all as specified and directed
M & L for precast PCC blocks or slabs 150 mm thick (1:2:4) mix type B-1 using 20 mm graded aggregated with plain or interlocking joints, Kerb stone on road side etc as directed complete in walls setting in CM (1:6).
M&L for preparation of new concrete surfaces of any description over 10cm girth or width, not otherwise described and applying two coat of synthetic enamel paint over a coat of primer complete all as specified
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles.
M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 for raising of height of drain, manhole / wall complete all as specified.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. rubbish off the premises.
M & L rendering 15mm thick on stone masonary surfaces or surface other than fair faces of brick work on wall in CM 1:4 finished even and smooth without using extra cement.
M & L rendering 15mm thick on stone masonary surfaces or surface other than fair faces of brick work on wall in CM 1:6 finished even and smooth without using extra cement.
Cutting openings through walls for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises
M&L brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 for raising of height of drain, manhole / wall complete all as specified.
M & L Sand stone slabs of 25mm in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete
M & L Preparing new plastered surfaces and applying three coats of white wash on ceiling complete all as directed.
M & L Preparing new plastered or unplastered surfaces of wall and applying two coats of cement base paint complete all as directed.
M & L Preparing new plastered surfaces and applying two coats of oil bound distemper over a coat of priming plastered surfaces with alkali resistant priming paint complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles and rubbish off the premises
M & L for Machine cut 20-25mm thick kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20mm screed bed in CM 1:6 complete all as directed.
M & L for glazed coloured ceramic tiles 300x450x7 to 8mm thick, on vertical surfaces of wall such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick screed plaster in CM 1:4 complete all as directed.
M&L Virified Ceramic tiles 9-10mm thick, light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set over & including 15mm thick screed in CM 1:6 jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
M&L for Virified Ceramic tiles 9-10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm,on vertical surfaces such as skirting, dados and risers to steps ,wall etc set over & including 10 mm thick cement plaster in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match colour of the tile complete all as directed
M&L for Non skid coloured joint free ceramic tiles 7mm to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor set and jointed in neat cement slurry and pointed in coloured cement match the shade of tiles over and including 15 mm thick screed bed in CM 1:6 complete all as directed
Taking down door chowkaht or frame of any description area n.exc 1.50 Sqm each without taking off shutters from the frame.
Taking down door chowkaht or frame of any description area exc 1.50 Sqm but n exc 4 Sqm each without taking off shutters from the frame.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube of 1.25 mm thickness suppling & fixing in opening as per specification & drawing complete all as directed
S&F Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
S & F 35mm thick factory made plain, framed, paneled door shutters kiln seasoned and chemically pressure treated second class, hardwood (two panels) with lock rail and panel of 9mm thick BWP commercial marine grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive confirming to IS-710. The size of rails and style shall be as per IS-1003 complete all as directed.
S & F 35mm thick factory made second class hardwood glazed and skelton door shutter kiln seasoned and chemically treated, open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete. The size of members of shutters shall be as specified in MES SSR Part-I complete all as directed.
S&F 300mm long aluminium anodized alloy sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts etc.
S & F 150mm long aluminium handles, cast type anodised complete
S & F 200mm long Aluminium barrel tower bolt stove enamelled black with bright bolt and fixed complete
S & F 150mm long aluminium anodised barrel tower bolts of extruded sectionand fixed complete
S & F 100mm size stainless steel butt hinges medium weight cold rolled and fixed complete all as directed.
S & F stainless steel wire cloth 0.63 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as directed.
Supply and fixing anodised aluminium frame of any type and cros section for door, windows, ventilators with one or more rebates incl jointing cleat for fixing/fittings etc complete all as specified
M&L for anodised aluminium frame of Powder Coating for grill, doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified.
S&F sheet glass 4.00 mm thick, ordinary quality and glazing with fixing in metalic frame in square exc 0.5 sqm in each pane complete all as directed
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and metalic frame and removing from site complete all as directed
Excavating in post holes each n exc 0.5 cum getting out, returning filling in and ramming earth or brokent rubble mixed with earth around, in layers not exceedings 25cm watering and removing surplus soil to distance n exc 50 m and making good surface in soft/ loose soils complete all as directed.
M&L for Providing PCC 1:3:6 type D-2 (40mm grade agg) as in foundations etc complete all as directed.
S & F Steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering also fastening and fixing conforming to FE 290 Gde-165 complete all as directed.
S&F band, straps, plates, angle cleats for securing purling to wood or tubular tress or rafter, witn ties etc Fe 410 or Fe 310
M&L for Steel work in tublar trusses incl spl shaped washer etc using ERW or induction butt welded tubes conforming to IS-1161-1998 gd St-240 complete all as directed
S&F Anodized aluminium snap grid frame work of size 605 x 605 mm for false ceiling including necessary notching. The snap grid shall consist of anodized aluminium main & cross tee of size 35 x 25 x 1.4 mm weighing 0.24 kg/RM and 25 x 25 x 1.40 mm weiighing 0.191 kg/RM respectively. The main and cross tee shall be jonted at junction crossing with anodized aluminium angle bracket of size 15mm x 15mm x 1.5 mm weighing 0.12kg/RM fixed with suitale MS bolts, nuts and washer. The snap grid anodized aluminium angle of size 35 x 25 x 1.6 mm weighing 0.36 kg/RM fixed to wall with suitable arrangement and providing 12 mm thick minral fibre boards in grid fixed as false ceiling grid and hanger 6 mm dia GI up 1200 long made of aluminium as per specificatiion all as specified and directed by Engineer-in-Charge
S&F sheet glass 5.5 mm thick, ordinary quality and glazing with rubber bedding and clips in square n exc 0.5 sqm in each pane.
S&F Solar control film 25 micron relfective type sticked to glass panes as per instructions of manufactures
S&F 6mm thick plywood, 5 ply grade BWE type BB fixed with screw to timber frame work with 0.90 mm decrative laminate type 1 of surface finish, colour and pattern as approved fixed with approved adhesive as per make instructions complete all as directed.
Taking up or down steel tubing and connection including cleaning of size 15 mm bore complete all as directed.
Taking up or down steel tubing and connection including cleaning of size 20 mm bore complete all as directed.
Taking up or down steel tubing and connection including cleaning of size 25 mm bore complete all as directed.
S&F GI tubing 15mm bore, medium grade with all fitting, fixed to wall or concealed or fitted to ceiling or laid under floor.
S&F GI tubing 20mm bore, medium grade with all fitting, fixed to wall or concealed or fitted to ceiling or laid under floor.
S&F GI tubing 25mm bore, medium grade with all fitting, fixed to wall or concealed or fitted to ceiling or laid under floor.
S&F in repair 15 mm bore bib tap fancy type chromium plated cast copper alloy with cruth or butter fly handle screwed down for iron pipeand fixed complete.
S&F in repairs PVC valveless, syphonic action type flushing cistern low level 10 ltr capacity white, with intel, ball valve, float and handle including brakects flushing, brakects flushing pipe complete all as specified & directed.
S&F PVC connections 15 mm size with PTMT nuts of length 600 mm.
S&F in repairs Vitreous China wash basin, white , flat back, size 550mmx 400mm, including brackets , coupling and waste pipe complete all as specified & directed.
S&F in repair Pillar tap, 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe.
S & F in repairs Vitreous China wash down water closet pan (Pedestal pattern), white including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device.
S&F in repair stop valve, 15mm bore, cast copper alloy, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe and fixed
S&F in repair angle stop valve, 15mm bore, cast copper alloy chromium plated screwed for iron pipe.
S&F in repair chromium plated shower roses of 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as directed.
S&F in repair ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe 25 mm dia and fixed (Minimum Weight 210 gms)
S&F in repair ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and fixed (Minimum Weight 142 gms)
S&F in repair PVC (SWR) pipes of 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors.
S&F in repair PVC (SWR) pipes of 110mm bore, single socketed, in any length with rubber ring joints, fixed to wall complete all as directed.
S&F PVC (SWR) bends any radius of 75 mm bore
S&F PVC (SWR) bends any radius of 110 mm bore
M & L for PVC (SWR) floor trap of 75mm bore, plain with grating including jointing with solvent cement
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
S&F in repair 15mm bore, gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe fixed all as directed
S&F in repair 20mm bore, gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe fixed all as directed
M&L for mild steel flat, round or square bars, in available lengths of grade Fe-410-w (Gde E-250) quality -A complete all as directed
S&F in reapir Rotatinal moulded polyethylene water storage tanks of 500 ltr capacity, double layed (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as directed.
S&F Brass chromium plated tubular towel rail 20 mm dia D type 60 cm long between flanges
M & L 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as plinth protection finishing even and smooth without using extra cement
Taking down existing roof treatment complete including PCC and properly clean the surface to remove loose particles with wire brushes and removing the debris out side of MoD Land complete all as specified and directed.
M&L for screed plaster 15 mm thick in CM 1:4 on roof surface complete and finished the surface even and smooth without using extra cement etc. complete all as specified and directed
M & L cutting out cracks to V section in existing roofs or terracing, cleaning out, and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 complete all as secified and as directed
M&L 25 mm thick cement concrete type B-0 (using 12.5mm size graded stone aggregates) average as in RCC roof surface to horizontal and vertical surfaces, finish the surfaces even and smooth using extra cement including necessary form work all as specified and directed.
M&L for surface painting with one coat of polymeric primer @ 0.40 Kg per sqm, conforming to IS : 3384, APP based polymeric membrane, 3 mm thick (min), weighing not less than 3 Kg/sqm, reinforced with polyster non woven fabric ( weighing not less than 150 gms/ Sqm). (Application of polymeric membrane shall be by torch application all as per manufacturer instructions, side overlap shall be 75mm and end laps shall be 100mm and all overlap joints shall be sealed well) including one coat of bituminous aluminium paints complete all as specified and directed
Taking down carefully surface aluminum or copper point wiring with exisitng PVC concealed conduit for (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into & including concealed rigid non metalic PVC conduit medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and terminated in and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenoic laminated white sheet cover for mounting switches, sockets, fan regulators as required for one light point controlled by one switch.
All as per item No. 90 here-in-before but one fan point controlled by one switch.
All as per item No. 90 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 90 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into into & including concealed rigid non metalic PVC conduit medium grade not less than 20mm dia ISI marked ivory colour with all conduit and terminated in and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenoic laminated white sheet cover one socket point 16 Amps controlled by one switch.
S&F switch piano flush button single pole one way 6 Amp complete.
S&F switch piano flush button single pole one way 16 Amp complete.
S&F socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete.
S&F ceiling rose 3 plates polycarbonate body complete.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into into & including concealed rigid non metalic PVC conduit medium grade not less than 20mm dia ISI marked ivory colour with all conduit and terminated in and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm and white modular cover plate for mounting modular switches, socket as required for one three pin socket point 16 Amps controlled by one switch.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into & including concealed rigid non metalic PVC conduit medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and terminated in and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm and white modular cover plate for mounting modular switches, socket as required for one light point controlled by one switch.
All as per item No. 102 here-in-before but one fan point controlled by one switch.
All as per item No. 102 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 102 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
S&F in repair LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 115 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete Make : Cat part No. Philips- BN 308C LED 205-6500 L120 PSU WH or equivalent as approved by GE
S&F in repair LED batten (0.6M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 1000 lumens at a minimum system efficacy of 100 lumen per watt and total power consumption not more than 10 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete.
M&L for earthing with galvanized steel earth plate electrode 600mmx 600mmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth Wire 4.0 mm dia , by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No. 03 of SSR Part -I connected to earthing point , PCC pit in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40mm thick cover, watering arrangement with funnel and wire mesh and 20mm bore medium grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earh work including testing on completion.
Taking down MCB distribution boards with incoming and out going controls, any make, any size & removing from site complete all as directed
S&F MCB distribution board, SPN, 12 ways, 240 volts powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as directed
S&F MCB distribution board, Tripple pole and neutral, powder coated CRCA steel sheet, suitable for 8 way 415 volts, degree of protection IP 43, IK-09 with reversible double door, recess mounted, having 100 Amps insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F in repair MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCBs of 'C' series Double pole 40 to 63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size & length complete all as directed Make : Cat part No. Philips-WT 202W LED GS PSU S2 PC or equivalent as approved by GE
S&F ceiling fans complete with blades, down rods electronic regulator and accessories, 230V, 1200mm sweep, Minimum air delivery 210CFM with service value 6.00 BEE 05 star rated with brushless direct current motor (BLDC) complete. Make Havells cat part No. ES 50 or equivalent as approved by GE
S&F exhaust fan, 300mm sweep, made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, coper winding complete all as directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated completed with all accessories such as safety valve, themostate, NRV connection piece etc.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L for sand cushioning to cable with dry fine sand in trenchs 8 cm below the cable and 15 cm above the cable after laying complete as specified and directed.
Supply and laying un-reinfored precast concrete cable cover, class LV, type-I, flat, size 250mm x 150mm x 40mm complete all as directed.
Dismantling and taking out UG cable any size unserviceable items fixed in any position and removal from site, all as directed.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 Sqmm nominal cross section 2 core laid in trenches,fixed to pole or passing through pipes including all necessary clamps,nuts, bolts washers complete all as specified and directed.
S&F 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 20 amp as directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store and hanging again after all repair and rewinding including cable for making connection etc complete all as directed.
Rewinding the motor of celing fan 1200/1400 mm of any type and make with super enamelled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption.
Renewal of ball bearing of ceiling / exhaust fan of any size and make as required with alignment of shaft and testing complete.
Renewal of AC film capacitor 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete.
Renewal of shaft of approved quality for ceiling fan / exhaust fan any make any type & size as required.
M&L for painting of ceiling fan of any sweep and make with one coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface with detergent etc
Renewal of rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of any size and make as required.
Renewal of PVC canopy suitable for ceiling fan of any size and make as required.
S&F post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant with driver and lamp copmlete all as directed.
M&L for clamp and back plates fabricated form steel section conforming to Gde FE410-0 or GE310-0 including nuts, bolts, washers, drilling holes for bolts in any shape or size for fixing ceiling fan complete all as directed.
M&L for submain wiring with two runs of single core PVC insulated and unsheathed, multistranded FRLS copper conductor of size 6.00 sqmm, LT cable, 1100 volts grade and one run of 6 sqmm single core, multistrand copper conductor (green) as earth continuity conductor drawn through existing concealed conduit complete all as specified and directed.
Supplying & fix modular switch one way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675501 or equivalent as approved by GE.
Supplying & fix modular switch one way 16 amp 1 module all as per Legrand Mylinc cat ref no. 675511 or equivalent as approved by GE.
Supplying and fixing modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent as approved by GE.
Supplying and fixing modular socket 6 amp 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675550 or equivalent as approved by GE.
Supplying and fixing modular hum free electronic step fan regulator, 100 watt 2 module all as per Legrand cat ref no. 675530 or equivalent as approved by GE.
Supplying and fixing energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required. Make - Philips cat ref no. RC365B LED33- 6500 PSU OD WH or equivalent as approved by GE.
Schedule of Credit
UNIVERSAL INFRAPROJECT PVT LTD
M/S ROHIT CONSTRUCTION
SAI MAX INFRAPROJECTS
MSR INFRATECH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .