Chief Engineer Jabalpur Zone
HQ Chief Engineer Jabalpur Zone Ridge Road Jabalpur Cantt 482001
PROVN OF RCC OH TANK 60000 GLN CAP 01 NO IN LITCHI BAGAN AREA 25000 GLN CAP IN INF BATTALION LOCATION CONNECTED PIPE LINES AT RANCHI
2025_MES_742672_1
753028A PROVN OF RCC OH TANK 60000 GLN CAP IN LITCHI BAGAN AREA 25000 GLN CAP IN RANCHI
Open Tender
Civil Works
Lump-sum
365 days
RANCHI
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE RANCHI
₹3.0 L
Yes
9 Apr 2026
22 Dec 2025
2 Feb 2026
22 Dec 2025
26 Jan 2026
19 Jan 2026
Lump sum
Lump sum
Lump sum
Lump sum
Item No 03 : M&L for centrifugally cast (spun) ductile Iron ISI marked with socket and spigot ends confirming to IS 8329/2000 for water supply line in standard length of 5.5/6 mtr of classification K-9 suitable for push on joint (rubber gasket DI joiting) with cement mortar lining inside the pipe with outside zink caating as per IS 8239/2000 induding M& L for push o joit laid in trenches and testing complete all as specified and directed of size 150 mm (6") dia ind cutting welding, grinding and jointing complete all as specified and directed.
Item No 04 : M&L for cetrifugally cast (spun) ductile iron ISI marked with flange joint confirming to IS 8329/2000 for water supply line in standard length of 3 mtr of classification K-9 suitable for flange joint (rubber gasket DI joiting) with cement mortar lining inside the pipe with outside zink coating as per IS 8239/2o0o induding M& L for flange joint laid vertically and testing complete all as specified and direoed of size 150 mm (6" dia incl cutting .welding, grinding and jointing complete all as specified and directed.
Item No 05 : M&L for centrifugally cast (spun) ductile Iron ISI marked with socket and spigot ends confirming to IS 8329/2000 for water supply line in standard length of 5.5/6 mtr of classification K-9 suitable for push on joint (rubber gasket DI joiting) with cement mortar lining inside the pipe with outside zink caating as per IS 8239/2000 induding M& L for push o joit laid in trenches and testing complete all as specified and directed of size 100 mm (4") dia ind cutting welding, gñnding and jointing complete all as specified and directed.
Schedule 'A' Part III
(External Water supply)
(a) 20 mm dia
(b) 25 mm dia
(c) 40 mm dia
(d) 50 mm dia
(a) 20 mm dia.
(b) 25 mm dia.
(c) 40 mm dia.
(d) 50 mm dia.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part-III
(Demolition)
Demolition of RCC in floors and paving n. exc 15 cm thikness (below or above ground level) complete all as specified and directed.
Demolition of RCC in roofs, floors (other than ground floors) beams chajjas lending slab and similar suspended works height up to exc 10.00 mtr from GL complete all as specified and directed.
Demolition of RCC in roofs, floors (other than ground floors) beams chajjas lending slab and similar suspended works height exc 10.00 mtr n exc 20.0 mtr from GL complete all as specified and directed.
Demolition of RCC in roofs, floors (other than ground floors) beams chajjas lending slab and similar suspended works height exc 20.00 mtr n exc 25.0 mtr from GL complete all as specified and directed.
Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) complete all as specified and directed.
Dismantling of 15 mm dia cast iron or renforced concrete drain pipes jointed in cement mortar and taking out of trenches complete all as specified and directed.
Removing building materials etc a distance upto 1.5 Km beyond the lead included in the rate including loading. Unloading and stacking at the load destination complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
SCHEDULE OF CREDIT
Old U/S Cross arm of any size
Old ACSR conductor
Old Copper bus bar/ copper strips of any size
Old Insulators of any size
Old 33/11 kV LAs of any size
Old 33 kV /11 kV GODs of any size
Old 33 kV /11 kV Horn Gap fuse of any size
Old PCC pole of any size
Old steel tubular pole of any size
Old 11kV Cable of 95/120 sqmm size
Old 33kV Cable of 300 sqmm size
Old 11kV Cable of 95/120 sqmm size
Old Scrap Iron
Old CI pipe of any type in any condition
Old UNSV CI fittings
Total :
Notes :- (a) All quantities shown under column 4 are provisional and may vary during execution. Actual amount of credit shall be worked out based on rates inserted under Col. 5 of Schedule of credit.
(b) Tenderers are advised to inspect the old material/ items at site and ascertain their condition. It shall be deemed that the contractor has made himself well aware and ascertained the condition of these items whether he inspects them or not. No claim whatsoever on this account shall be admissible by the Government. The mode of measurement shall be same as for the work to executed. tenderers are requested to verify the condition of the materials, any dispute arises at later stage will not be entertained.
(c) The items as indicated in Schedule of credit shall be the property of the contractor. The total amount of Schedule of credit shall be deducted from total of Schedule „A' [BOQ] to arrive at Contract Sum.
(d) The rates inserted under Column 5 are firm and the contractor shall have no claim what so ever against the department if the actual value of dismantled materials turns out to be different from the cost given by the department.
(e) All above materials shall be recorded in MB jointly by Engineer-in -Charge and contractor.
(f) No rebate on Schedule of credit shall be accepted.
Signature of contractor
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.11 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.80 MB
TENDER.pdf
Tender Documents • 4.33 MB
BOQ_834917.xls
BOQ • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .