| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-Finance B 13 ROOM NO 26 2ND FLOOR GEETANJALI NAGAR JASMINE MILL ROAD MAHIM EAST MUMBAI 400 017 | MUMBAI | MAHARASHTRA | 400017 | L1 | Accepted-Finance Responsive | |
| 2 | L2₹16.7 L+₹37,811.54 (2.31%)Accepted-Finance B 4 BEHIND DR SHAIKH BABA COPOUND GATE NO 4 TAGORE NAGAR VIKHROLI EAST MUM 83 | MUMBAI | MUMBAI | MAHARASHTRA | L2 | Accepted-Finance Responsive | |
| 3 | Not Admitted-PreQual/Technical | - | Not Admitted-PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/s VEETRAG ENTERPRISES L1 | MAHARASHTRA TRADING AND GENERAL SUPPLIERS L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation for foundation, substructures, basements, tanks, sumps, walls, chambers, manholes, trenches, poles, pits & general building works in soft/ disintegrated rock, sand stone, stiff clay, gravel, cobble stone, hard laterite, water bound macadam, wet mix macadam, asphalt mix carpet of any type, pitching, soling, paths and hardcore, lime concrete, plain cement concrete, stone masonry and all types of brick/ block masonry below ground level, rock boulders, etc. for depths/lifts upto 1.5M measured from the ground level, including dressing/trimming the sides, leveling of bottoms, manual dewatering, removing rank vegetation, backfilling in layers not more than 200mm thickness, watering, consolidating, compacting to achieve not less then 97% Modified Proctor density conforming to relevant IS, stacking in measurable heaps for future use within owners space or disposing within an initial lead of 150m as directed, loading, unloading, leveling excluding shoring, strutting etc. complete as directed by Engineer-in-Charge.
Note:
1) The rate includes the handling/supporting the existing utilities such as cables, drains, pipes, water mains etc.
2) It also includes the royalty and other taxes if any. | 92.21 | Cum | 621.4 ₹57,299.29 Lowest | 635.76 ₹58,623.43 |
| 2.00 | Providing & Laying dry stone Rubble Soling with average 230 mm size hard stone set in regular lines, handpacked and interstices thoroughly filled with small chips including filling in with good quality murum brought from outside, compacting with iron rammers, watering, sand spreading 12mm thk. layer of grit on top etc complete as directed by Engineer In Charge. (Note: The rate includes the royalty and other taxes if any) | 44.53 | Cum | 2,348.57 ₹1,04,581.82 Lowest | 2,402.84 ₹1,06,998.47 |
| 3.00 | Providing and laying in position plain cement concrete of specified grade cement with trap / granite /quartzite/gneiss metal mixing in concrete mixer including bailing out water, compacting, finishing surface, curing and including the cost of centering and shuttering at all level :
Nominal Mix of 1:3:6 (1 Cement OPC: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). | 29.04 | Cum | 6,447.46 ₹1,87,234.24 Lowest | 6,596.47 ₹1,91,561.49 |
| 4.00 | M-20 grade plain cement concrete (cement content considered @ 260 kg/cum) as er specification. | 35.18 | Cum | 6,206.24 ₹2,18,335.52 Lowest | 6,349.67 ₹2,23,381.39 |
| 5.00 | Foundations, footings, bases of columns, rafts, pilecap as per specifications | 4.73 | Cum | 6,808.33 ₹32,203.4 Lowest | 6,965.68 ₹32,947.67 |
| 6.00 | Columns, Pillars, Piers, Posts and Struts as per specification. | 1.28 | Cum | 11,161.96 ₹14,287.31 Lowest | 11,419.93 ₹14,617.51 |
| 7.00 | Providing and Fixing of Foundation Bolts and nuts in RCC column / pedestal / beam at any level including maintaining the accuracy towards line, level & position including making and using the template etc. complete as directed by Engineer In Charge. (Contractor will take due care for its threads and rusting by applying grease and cotton waste. | 0.06 | MT | 3,00,523.89 ₹18,031.43 Lowest | 3,07,469.36 ₹18,448.16 |
| 8.00 | Providing, detailing, fabricating and fixing at desired location using hot rolled sections and MS Plates of grade Fe 250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), transporting to site and erecting structural steel members for all heights & at all levels including provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary fixtures and operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding and removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. (The qty. for this item shall be measured for gusset plates, base plates, bolts in M.T.) | 8.05 | MT | 87,686.25 ₹7,05,874.31 Lowest | 89,712.79 ₹7,22,187.96 |
| 9.00 | Bare Galvalume/zincalume sheets for roofing as per specification. | 178.5 | Sqm | 643.59 ₹1,14,880.82 Lowest | 658.46 ₹1,17,535.11 |
| 10.00 | HYSD steel bars (Fe 415) as per specification. | 1.26 | MT | 79,483.64 ₹1,00,149.39 Lowest | 81,320.6 ₹1,02,463.96 |
Tender Value
Refer Docs
EMD Value
₹20,100
Closing Date
25 Aug 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
E.E.Mech.South
Municipal Workshop, R. S. Nimkar Marg, Byculla, Mumbai 400 008
Provision for extension of existing OHD protection facility at vehicle servicing area of Garlick Garage
2025_MCGM_1210885_1
DyChEng_MnE_1117_City
Open Tender
Metal Fabrication
Item Rate
Municipal Workshop
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,284
₹20,100
3 Oct 2025
19 Aug 2025
26 Aug 2025
19 Aug 2025
25 Aug 2025
19 Aug 2025
19 Aug 2025 - 25 Aug 2025
Amount
Excavation for foundation, substructures, basements, tanks, sumps, walls, chambers, manholes, trenches, poles, pits & general building works in soft/ disintegrated rock, sand stone, stiff clay, gravel, cobble stone, hard laterite, water bound macadam, wet mix macadam, asphalt mix carpet of any type, pitching, soling, paths and hardcore, lime concrete, plain cement concrete, stone masonry and all types of brick/ block masonry below ground level, rock boulders, etc. for depths/lifts upto 1.5M measured from the ground level, including dressing/trimming the sides, leveling of bottoms, manual dewatering, removing rank vegetation, backfilling in layers not more than 200mm thickness, watering, consolidating, compacting to achieve not less then 97% Modified Proctor density conforming to relevant IS, stacking in measurable heaps for future use within owners space or disposing within an initial lead of 150m as directed, loading, unloading, leveling excluding shoring, strutting etc. complete as directed by Engineer-in-Charge. Note: 1) The rate includes the handling/supporting the existing utilities such as cables, drains, pipes, water mains etc. 2) It also includes the royalty and other taxes if any.
Providing & Laying dry stone Rubble Soling with average 230 mm size hard stone set in regular lines, handpacked and interstices thoroughly filled with small chips including filling in with good quality murum brought from outside, compacting with iron rammers, watering, sand spreading 12mm thk. layer of grit on top etc complete as directed by Engineer In Charge. (Note: The rate includes the royalty and other taxes if any)
Providing and laying in position plain cement concrete of specified grade cement with trap / granite /quartzite/gneiss metal mixing in concrete mixer including bailing out water, compacting, finishing surface, curing and including the cost of centering and shuttering at all level : Nominal Mix of 1:3:6 (1 Cement OPC: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
M-20 grade plain cement concrete (cement content considered @ 260 kg/cum) as er specification.
Foundations, footings, bases of columns, rafts, pilecap as per specifications
Columns, Pillars, Piers, Posts and Struts as per specification.
Providing and Fixing of Foundation Bolts and nuts in RCC column / pedestal / beam at any level including maintaining the accuracy towards line, level & position including making and using the template etc. complete as directed by Engineer In Charge. (Contractor will take due care for its threads and rusting by applying grease and cotton waste.
Providing, detailing, fabricating and fixing at desired location using hot rolled sections and MS Plates of grade Fe 250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), transporting to site and erecting structural steel members for all heights & at all levels including provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary fixtures and operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding and removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. (The qty. for this item shall be measured for gusset plates, base plates, bolts in M.T.)
Bare Galvalume/zincalume sheets for roofing as per specification.
HYSD steel bars (Fe 415) as per specification.
Point wiring by using FRLSH insulated copper conductors (alongwith same size of FRLSH insulated copper conductor for earthing & 3 plate ceiling rose) using CASING-N CAPING: Light /Fan / Ex. fan Points
Point wiring by using FRLSH insulated copper conductors (alongwith same size of FRLSH insulated copper conductor for earthing & 3 plate ceiling rose) using CASING-N CAPING: 5A/6A - 3/5 Pin Plug On Board
LED Tubelight fixtures 1X 18W
Exhaust fan of 450mm sweep, 1400RPM, with 3650 CFM free air delivery, AC 415V , 50 Hz, Three phase complete with all necessary accessories for completing installation
Wall mounting air circulator of 600mm sweep, 230 Volts,AC 50 Hz, oscillating type complete with all necessary accessories for completing installation.
LED Low Bay luminary -150W
MAHARASHTRA TRADING AND GENERAL SUPPLIERS (BID ID -6837131)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .