Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC Being as lowest tender | |
| 2 | L2₹21.0 L+₹2.8 L (15.6%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L2 | Rejected-Finance Other than lowest |
Tender Value
₹21.4 L
EMD Value
₹42,820
Closing Date
15 Dec 2020, 6:00 pmClosed
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
PROVISION OF OPEN SIT OUT AND FLOOR TILES IN WATING AREA IN TRIDENT MESS PROVISION OF TOILET IN GE P EAST AND CERTAIN B R WORKS IN 505 ARMY BASE WORKSHOP AREA OF AGE B R I AND PROVISION OF DESERT COOLERS FOR OTM BLDG NO P 48 AND P 52 OF 2 FTSG AT
2020_MES_395135_1
GE/NORTH-68/2020-21
Open Tender
Civil Works
Item Rate
120 days
GE (N) DELHI CANTT-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹42,820
Yes
23 Jan 2021
13 Nov 2020
17 Dec 2020
13 Nov 2020
15 Dec 2020
27 Nov 2020
Amount
B/R Works Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil all as specified and as directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth in foundation and getting out in soft/loose soil all as specified and as directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone agg as in foundation, filling and mass concrete all as specified and as directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4, type B0 damp proof course to horizontal or vertical surfaces including necessary formwork.
Earth filling under floor spreading and leveling in layers n.exc. 25cm thick including well ramming including watering as required all as specified and as directed.
M&L for Hard core of gauge n.exc. 63mm of branch stone, and leveled in layers n.exc. 15cm thick watered and rammed to a true surface all as specified and as directed.
M&L for PCC 75mm thick , 1:3:6 using 20 mm graded stone aggregate as in sub base all as specified and as directed.
M&L 75 mm thick PCC 1:3:6 type C2 finished even and smooth without using extra cement as in plinth protection, paths , steps etc all as specified and as directed.
Returning filling and spreading leveling watering and well ramming in layers n.exc 25 Cm in soft/loose soil all as specified and as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the staring point in soft/loose soil all as specified and as directed.
M&L for 15mm thick rendering on fair face of brick wall or concrete surface in CM 1:6 finished even & smooth as in internal surfaces all as specified and as directed.
M&L for 15mm thick rendering in CM (1:4) on fair/un-even surfaces of brick work or concrete surfaces to be finished even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering on fair face of brick wall surface in CM 1:4 mixed with WPC finished even & fair on external wall as specified and as directed.
All as per item No.15 above but 05 mm thick in CM (1:4) on ceiling, complete all as specified and directed.
S&F roof trusses/trussed/ purlins/rails and fastning heavy brackets framing (Beam , T,angleor flat section) including distance pieces all as spd .
MS tubular structures as in truss, purlins rafters, posts including induction butt welded tubes conforming to Gde St-240
M&L for MS Plates, plain or chequered, of any thickness as in gusset plate , cover plate etc in thickness in available sizes for Gde-Fe-410-W Gde-E-250 qulaity B all as directed.
S&F for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick consisting of thermoplastic core of anti oxident LDPE sandwitched betweenwith insulated thermresistance poly fiber, as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed by Engr-in-Charge.
S&F for Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering eaves board, gutter, valley and in cladding to wall fixed with self tapping screws all as specified and directed by Engr-in-Charge.
Supply only integral Water proofing compound.
M&L for RCC (1:2:4) 20mm graded aggregate in Foundation all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders bressummers, lintels, cantilvers, shelves including sup-ports, overhangs, etc. also splays between floors and beams, etc.
M&L Mild steel bars 10mm dia & over cut to length bent to shape required incl cranking bending spirally for lintels, columns, slabs incl mild steel wire (annealed)) not less than 0.90mm dia or securing with clips quality TMT bars
All as per above item 25 but 6 to 8mm as in stirrups all as specified and as directed.
M and L for preparation of newly or previously untreated surfaces of steel or iron work over 10 cms width or girth and applying two coats of synthetic enamal paint over a coat of Zink chrome red oxide primer complete all as specified and directed.
Treating the bottom and sides of excavation, top of surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area
Treating the backfill in contact with foundation at the rate of 7.5 litres of mulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
S&F 10 mm thick toughned glass door shutters of size area exc 1.50 Sqm but n exc 4.00Sqm, including diamond edging all sides,making of eatching, lining and monograme area nexc 0.50 sqm each by sand blasting design and pattern as aproved by Engineer in charge neccessary floor spring hydraulically regulated, otherside fixed on pivote.CP fiitings and fixtures, 2 numbers 450 mm long CP handles ,CP Locking arrangment,synthatic transparrent beading at edge of door for air lock ,neccessary cuting & holes moulding and fixed in complete as specified and directed by Engr in Charge.
S & F 10 mm thick toughened glass as in partition including diamond edging all sides,making of eatching, lining and monograme area nexc 0.50 sqm each by sand blasting design and pattern as aproved by Engineer in charge , icluding CP "L" , "U" or spider heavy duty clams suitable for fixing of glass , min 4 nos per sqm all as spd and directed.
S & F 32mmx32mm square Chromium plated Stainless steel Structurel Pipe including induction butt welded tubes and grinding for smooth finish including bendig to a required shape ,complete all as specified and direcred.
Supply and fixing 4mm thick Aluminium Composite panels in metalic colours as in ceiling, external /internal wall/column cladding, in any shape and pattern consisting of 3 mm thermoplastic core of anti oxident LDPE sandwitched between two skins of 0.5mm thick alloy sheet, finished with PDVF base coating on the front side and polymer paint service coating on the reverse side confirming to ECCA of AAMA, mounted on anodic (20 microns thick) coated aluminum tube frame 25x50mm & 1.6 mm thick, designed to withstand wind pressure of 200 Kg /Sqm fixed to the brick/RCC/ MS framed structure with necessary hot diped galvanised (80 micron thick) clamps, bracket and anchor fasteners confirming to IS: 4759-1996. Extruded sections shall be of 6063 T5 or T6 alloy confirming to ASTM B-221. The rates quoted shall include Alluminum frame, ACP Panels, clamps 110 mm size, weather sealant, gasket, foam, fixture, scaffolding, all machineries and other fastening streps, nuts/bolts, rivets washers and cost of approved shop drawing etc Complete all as directed.
S & F Gl frame work for step up and down designer seamless ceiling and wall lining comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete in all respect as specified and directed. Note: Entire work to be executed through authoried rep of manufacturer.
M & L for step up and down designer false ceiling & wall lining with 12 mm th Gypsum board as per as per approved design & pattern fixed with screw or as per manufacturers instructions including taping form work etc complete in all respect as specified and directed. Note: Entire work to be executed through authoried rep of manufacturer.
S& F Ulta voilet Window film , heat controll and scratch resistance fixed on glass complete as specified and directed.
S&F powder coated Aluminium section of size 44x44x1.5mm fixed with self driven screw over roof sheeting , design and pattern as approved by Engg- in - charge
M&L double charged vitrified coloured tiles (1000 mmx1000mm) ,10 mm thick in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the exisiting surface including 15 mm th screeding in CM (1:6) all as spd and directed.
M/L 18- 20mm thick granite (of any type) work (table rubbed and polished) as in pillars, steps and like set and jointed in neat cement slurry and pointed in coloured cement to match the exisiting surface including 15 mm th screeding in CM (1:4) all as spd and directed.
M&L for machine cut kota stone 20-25 mm thick over and including 15 mm thick cement screed base in CM 1:4 laid and jointing with 3 kg neat cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed
Grinding and polishingf edges of granite slabs in any shape as directed and specified.
Roughning surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc and brushing neat cement slurru with 3.00 Kg of cement per Sqm all as spd and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:6) on fair/un-even surfaces of brick work or concrete surfaces to be finished even and smooth without using extra cement, complete all as specified and directed.
M&L three coats of white wash on newly plastered surfaces of wall including preparation, complete all as specified and directed.
M&L three coats of white wash on newly plastered surfaces as in ceiling including preparation, complete all as specified and directed.
M&L for preparation of new plaster surfaces and applying two coat of cement base paint over alkali resistence primer on wall complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface.
M&L for 100mm thick cement concrete type D-2 1:4:8 (40mm graded agg) as in sub floor; complete all as specified and directed.
M&L for 25mm thick cement concrete type B-0 (1:2:4) using 12.5mm graded stone aggregate as in levelling course, complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n. exc. 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement over and including15mm thick screed/bedding layer in CM (1:6), complete all as specified and directed.
M&L for glazed coloured ceramic tiles of size 450x300x7mm thick on vertical surfaces such as skilting/dado over 10mm thick rendering in CM (1:4), complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete glazing bars dovetailed or welded, complete all as specified and directed.
S&F 3mm thick steel glass ordinary quality and glazing with oil putty in squares area not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
M&L synthetic enamel paint on newly steel surfaces two coats including primer and preparation, complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, complete all as specified and directed.
S&F solid PVC door frame of size 50 mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, in opening as per specification & drawing.
S&F aluminium handle cast type anodized 150mm, complete all as specified and directed.
S&F 100 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed.
S&F aluminium anodized barrel tower bolts of extruded section of length 150mm and fixed with cadymium plated wood series, complete all as specified and directed.
S&F aluminium alloy anodized sliding door bolt 300mm with hasp staple, complete all as specified and directed.
S&F GI tubing medium grade with all fittings and fixed complete to wall, coiling or laid in floors of 15mm bore, complete all as specified and directed.
M&L for cutting chasses for concealed water tubing of 15mm dia and making good, complete all as specified and directed.
S&F steel water tubing 20mm bore medium grade fixed to walls, complete all as specified and directed.
Supply 10 Ltrs capacity PVC low level valve less flushing cistern (white) symphonic action type with all fittings such as inlet ball valve bloat and handle and flush pipe of polythene, complete all as specified and directed.
S&F vitreous china wash down water closet pan (padestal pattern) white and trap incl connection to drain or outgoing pipe and to flushing pipe anti symphonize pipe and Plastic water closet seat, white, closed pattern with flat bottom, & cover & mild steel CP or aluminised hinging device etc complete all as specified and directed.
S&F PVC waste pipe 32mm dia for WHB, complete all as specified and directed.
S&F PVC connection 15mm dia 450mm long with brass coupling/unions on both ends suitable for flushing cistern and WHB, complete all as specified and directed.
S&F in repairs cp brass toilet paper holder complete all as specified and directed.
S&F 15mm bore bib taps cast copper alloy chromium plated with crutch or butterfly handle screwed down, complete all as specified and directed.
S&F CP hygienic spray (health faucet with 1.5M long tube) complete all as specified. MAKE : PRAYAG/CERA
S & F 15 mm bore CP Angle Stop valve fancy type high pressure screwed for iron pipe and fixed complete all as specified
S&F vitreous china wash hand basin with stand white flat back of size 550x400mm including cutting for and pinning in ends of brackets, PVC flexible waste pipe 32mm dia, brass chromium plated waste fittings, PVC connecting pipe and CP pillar tap etc complete all as directed and spcified. (Make : CERA/HINDWARE)
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F PVC (SWR) bends any radius 75mm dia
S&F PVC (SWR) bends any radius 110mm dia
Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate, 75mm thick as in plinth protection/pavment and the like, finish the surfaces even and fair without using extra cement all as directed and specified
Supplying, laying and testing of 100mm dia SGSW (salt glazed stone ware) drain pipe grade 'A' laid in trenches to level/gradient, jointed in CM (1:1), all as specified for the following internal dia, complete all as specified and as directed by Engineer-in-Charge.
M&L for concrete bed to 100mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate including necessary shuttering and supports to concrete and for laying beds to falls complete all as specified and directed for the following bore of pipes :-
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in benching and coping of manholes etc including necessary form work, complete all as specified and as directed by Engineer-in-Charge.
S&F PVC water tanks 500 ltr cap rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I.
Form work to soffits of suspended slab such as roof slabs, floor slabs and similar work; n. exc 200mm thick(horizontal or sloping) all as specified and directed by Engr in Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders bressummers, lintels, cantilvers, shelves including sup-ports, overhangs, etc. also splays between floors and beams, etc.
Form work to edges of concrete flats, floor and roofs n. exc 20 cm wide horizontal or sloping and similar work exc 10cm but n exc 20cm wide
Mild steel bars(TMT) 8mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooking for columns hooking ends and binding with and for and including MS wire (annealed) not less than 0.9mm dia.
All as per item No.87 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L for reinforcement cement concrete type B-1 1:2:4 (20mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings and in shelves and the like.
M&L for reinforcement cement concrete type B-1 1:2:4 (20mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span.
S&F Shelf of PTMT fixed with & including CP brass screws & wooden / platic cleats (min. weight 300gms)
S&F cast iron 75mm nahani trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed.
S&F vitreous china urinal, half stall type, white (back wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe
S & F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum weight 60 gms)
Brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall in cement mortar 1:4 coplete all as specified and directed.
M&L for providing precast reinforcement cement concrete (1:2:4) type B-1 using 20mm graded aggregate in man holes covers slabs all as specified.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 100/150mm dia pipes complete all as specified and as directed.
S & F 20 mm dia brass CP towel rail 24" all as specified and directed by Engr in Charge
S& F 20mm dia Ball valves high pressure of PTMT with epoxy oatedAluminium rod & high density plastic ball screwed for iron pipeand fixed. (Minimumweight 15mm-142gms/2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm- 690 gms) ®
S&F 15mm dia Stop valves, cast copper alloy,screwed down,high pressure,with crutch orbutterfly handle,screwed bothends for ironpipe or forunions and fixed
M&L for preparation/roughning of the plastered/unplastered roof surfaces incl of removal of grass, small trees and fix the APP polymeric water proofing membarance of minimum 3mm thickness & weighing not less than 3.6kg/sqm of Make : 'Superthemolay' manufactured by M/S STP Ltd or HYPER PLAS (Poleyster) manufactured by M/S IWL ltd or SHALIPLAS (Poleyster) as approved by GE, black finished reinforced with non-woven poleyster matt. With a thermofusible finish laid over 85/25 grade bitumen @ 1.2Kg/Sqm over bitumenous primer at the rate of 0.40 kg/sqm, torching overlaps with a propane or a butane gas torch with a overlap of 100 mm at the sides and 150 mm at the ends and sealing applying a consistent coat of bituminous paint over APP surface all as per manufacturers instructions over and including screed bedding 15mm thick on brick/roof surfaces in cement mortar 1:4, mixed with water proofing compound and SBR of FOSROC as per manufactrurs instruction complete all as directed and specified
Treating the bottom and sides of excavation, top of surface of filled earth, under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
40mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork in PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate
Demolition of PCC of any description and any position complete all as specifed
TMT steel bars of dia 10mm and over cut to length bent to shape required and binding with MS wire annealted of dia n less than 0.9mm dia
15mm thick plastering in CM 1:4 on brick masonary surfaces finihsed even and smooth with out using extra cement
M&L providing precast cement concrete type 1:2:4 (using 20mm ) in landing, cover slabs (for manholes) complete all as specified and directed
E/M Portion M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete for one light/fan point controlled by one, one way switch 06 Amps
All as peritem No 109 here-in-before but one fan point controlled by one, one way switch 06 Amps
All as per srl item No 109 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per srl item No 109 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Serial Item No 109 above but point wiring with 2.5 Sqmm SC FRLS cables and earth continuity wire of 1.5 Sq mm SC FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete
S&F modular switch, 06 Amps, single pole, one way, 250 volts, one module and IP 20 protection complet AHCSXXW101/061 or Philips, Cat No : 913702314401)
S&F modular switch, 16 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete (Make : Legrand, Cat No : 6755 13 or equivalent in Havells, Cat No : AHCSXIW161 or Philips, Cat No : 913702314801)
S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete (Make : Legrand, Cat No : 6755 50 or equivalent in Havells, Cat No : AHLKPXW065 or Philips, Cat No : 913702309701)
S&F modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete (Make : Legrand, Cat No : 6755 55 or equivalent in Havells, Cat No : AHLKCXW163 or Philips, Cat No : 913702309901)
S&F modular ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 120 watts, duly ISI marked complete (Make: - Legrand, Cat No. 6755 30 or equivalent in Havells, Cat No : AHLRFHW005 or Philips, Cat No : 913702331601)
S&F ceiling fan 1400 mm sweep, 230 Volt, AC Energy Saving type, white colour, complete with all accessories, nuts bolts, clamps etc and connecting up with provn of copper flexible cable of size 1.5 Sqmm from ceiling rose to fan complete (Make : Havells Model No ES-50 Premium 5. or equivalent in Bajaj/ Crompton Greaves)
S&F recess mounted downlighter 12 watt in warm white light with pressure die cast aluminium heat sink and PC diffuser in white powder coated finish with integral LED driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 138 mm dia height 90 mm incl connection complete
S&F recess mounted downlighter 7 watt in warm white light with pressure die cast aluminium heat sink and PC diffuser in white powder coated finish with integral electronic LED driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 138 mm dia height 90 mm incl connection complete
S&F flexible LED digital strip, 24 watt, colour coordinated 5 mtr RGB strip with light travel function including LED driver for 24 watt in warm white light, IP 40 and connection complete all as directed (Make : Havells FLEXON LED DIGITAL RGB STRIP IP40 Cat No. LHEHDNPNUN4F024 or equivalent in Philips/ Wipro)
S&F pressed sheet metal enclosure (MCB DB), Triple pole and neutral with 200 Amps rated bus bar, double door type, 240 volts, DB to be grouted on wall including disturbed surface to match existing surface complete for 4 way
S&F MCB Triple pole & neutral 63 amp, 240 volts, 'C' series, 10 KA breaking capacity & connection complete
M&L for two single core (submain) PVC insulated cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete (For Cassette ACs from TPN DB)
S&F pressed sheet metal enclosure (MCB DB), single phase and neutral with 200 Amps rated bus bar, double door type, 240 volts, DB to be grouted on wall including disturbed surface to match existing surface complete for 8 way
S&F MCB single pole, 240 volts, 'C' series, 10 KA breaking capacity & connection complete of the following capacity :-
(a) 10 to 32 amps rating
(b) 63 amps rating
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to DB, testing the earthing after completion all as specified and shown in electric plate No 5 of MES SSR Part-I 1991 print and as directed .
Supply, installation, testing and commissioning of Hot and cooled Air Conditioner Cassette type, electric driven, single phase of capacity 2.0 TR, 5 star rating and energy efficiency rating (EER) 3.2, including indoor & outddoor unit, wind free technology avoids cold draft and provides uniform temperature across the room, individual blade control provides customised comfort, operation range - 15 Deg C to 52 degree C complete with cardless remote control unit, twin rotory copper compressor, suction copper piping, condensate drain piping, iron rod frame, stand as per site requirement complete all as directed (Make:- Hitachi/ Daikin/ O-General/ Blue Star) (Note :- Manufacturer Warranty: 1 Year on Product, 1 Year on Condenser, 3 Years on Compressor)
Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor wall mounted type, fully elecronic controlled & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5 % and of capacity 5.0 KVA complete all as directed (Make : Microtech/Blue Bird/V-Guard/Zenith/Sinetrac)
S&F industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volts of 32 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for laying of electric cable complete in any type of soil complete
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete
M & L for sand cushioning with Ganga Sand to underground cable (15 cm thick before laying and 8 cm thick after laying the cable complete
M&L for GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified and directed for 40 mm bore size
Supply and lay cable in trenches/through pipes/ducts or on poles, XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 16 Sqmm 4 core size (Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately)
Supply and fixing of desert / Air Cooler 25"x25"x32" body made out of 18 SWG GI sheet duly powder coated paint with 500mm sweep copper wound fan motor kit 180 watt ISI marked 1400 RPM, 230 Volt AC and tank capcaity not less than 60 ltr f fitted in existing window with 6mm thick plywood to cover the gap complete all as specified and directed
R. S. Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .