| 1 | L1₹3.2 LAccepted-AOC | ₹3.2 L | L1 | Accepted-AOC Being L1, Work has been awarded to M/s- COOL CONTROL CORPORATION |
| Sl No | Description | Qty | Unit | COOL CONTROL CORPORATION L1 |
|---|---|---|---|---|
| 1.01 | Laying of existing PVC insulated, PVC sheathed aluminium conductor armoured cable of following sizes on the existing M.S. tray/surface of wall with saddles/PVC thread screws etc. complete as required.(For package).(a) 4 x 16 Sq. mm. on cable tray clamped with 1mm thick saddle. | 60 | Mtrs | 4,500 ₹5,310 Lowest |
| 1.02 | S/M end termination for the 4x16Sqmm PVC insulated PVC sheathed Aluminium conducter armoured cable of 1.1KV grade with brass compression gland and Aluminium lugs i/c crimping the aluminium lugs etc.as required (1Set comprising three lugs & one gland). | 10 | Sets | 3,500 ₹4,130 Lowest |
| 1.03 | S/F 2 x 1.5Sqmm PVC insulated PVC sheathed Copper conducter armoured cable of 1.1KV grade on the existing cable trays /surface complete with its end terminations etc.complete as required. | 45 | Mtrs | 11,250 ₹13,275 Lowest |
| 1.04 | Providing annuaciator control / alarm in the existing LT panel for the AC package system with necessary indications, contactors, fuses, relays thermostats, humidistats, sensing devices for:- (A) Audio Visual indication in case of following:- (a) Switch room tem. higher than pre set value 23C±3C. (b) Fire alarm, (c) Fire damper closer. (d) Fresh Air Fan fail. (B) INTERLOCKS:- (a) Stoppeage of A/C package in case operation of F/D alarm by provision of suitable contactors for tripping of package AC system. | 1 | Job | 20,000 ₹23,600 Lowest |
| 1.05 | S/F of suitable size volume control damper made out of 18 gauge GI sheet for making connection with the package etc complete as required. | 3 | Sq.mtr | 27,000 ₹31,860 Lowest |
| 1.06 | S/F of suitable Size Canvas for making connection with the package etc complete as required. | 3 | Job | 14,400 ₹16,992 Lowest |
| 1.07 | S/f 4 core 16 sqmm PVC insulated armoured aluminiumr cable i/c making connection etc. complete as required. | 50 | mtr | 22,750 ₹26,845 Lowest |
| 1.08 | Dismantlling of existing 7 TR Package A.C. unit with outddoor condensor unit I/c refrigerent pipeing, tray of Package AC unit from package unit for reuse etc.complete as required. | 8 | Nos | 40,000 ₹47,200 Lowest |
| 1.09 | Shifting of existing Old Package AC indoor unit from Plant Room to outside the plant room etc.complete as required | 8 | Job | 12,000 ₹14,160 Lowest |
| 1.10 | Labour Charge for reinstallation of recovered Duct Damper Fire damber, Nut, Bolt, Bars, Gaskit, Fashner & canvas connection etc. complete as required. | 2 | Nos | 4,000 ₹4,720 Lowest |
Tender Value
₹3.0 L
EMD Value
₹6,078
Closing Date
28 Jan 2025, 4:00 pmClosed
Executive Engineer (Electrical)
O/o Executive Engineer (Electrical) BSNL Electrical Division 1ST Floor, Bhopal House, Lalbagh Lucknow
SITC of 15 X 7 TR MB HP AC Air-conditioning PKG Units for different sites in various circles in BSNL on PAN India basis except NE, JK, AN, and Lakshadeep. RC. Sh Associated work for SITC Of 3 nos 7TR MB, HPAC , AC PKG Unit for MSC at RTTC LKO
2025_BSNL_224559_1
72/TEDL/BSNL/2024-25, dated 17.01.2025
Open Tender
Electrical Works
Item Rate
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
AO, (Cash), O/o The GMTD, BSNL, Lucknow
₹6,078
Yes
29 Jul 2026
22 Jan 2025
29 Jan 2025
22 Jan 2025
28 Jan 2025
22 Jan 2025
Laying of existing PVC insulated, PVC sheathed aluminium conductor armoured cable of following sizes on the existing M.S. tray/surface of wall with saddles/PVC thread screws etc. complete as required.(For package).(a) 4 x 16 Sq. mm. on cable tray clamped with 1mm thick saddle.
S/M end termination for the 4x16Sqmm PVC insulated PVC sheathed Aluminium conducter armoured cable of 1.1KV grade with brass compression gland and Aluminium lugs i/c crimping the aluminium lugs etc.as required (1Set comprising three lugs & one gland).
S/F 2 x 1.5Sqmm PVC insulated PVC sheathed Copper conducter armoured cable of 1.1KV grade on the existing cable trays /surface complete with its end terminations etc.complete as required.
Providing annuaciator control / alarm in the existing LT panel for the AC package system with necessary indications, contactors, fuses, relays thermostats, humidistats, sensing devices for:- (A) Audio Visual indication in case of following:- (a) Switch room tem. higher than pre set value 23C±3C. (b) Fire alarm, (c) Fire damper closer. (d) Fresh Air Fan fail. (B) INTERLOCKS:- (a) Stoppeage of A/C package in case operation of F/D alarm by provision of suitable contactors for tripping of package AC system.
S/F of suitable size volume control damper made out of 18 gauge GI sheet for making connection with the package etc complete as required.
S/F of suitable Size Canvas for making connection with the package etc complete as required.
S/f 4 core 16 sqmm PVC insulated armoured aluminiumr cable i/c making connection etc. complete as required.
Dismantlling of existing 7 TR Package A.C. unit with outddoor condensor unit I/c refrigerent pipeing, tray of Package AC unit from package unit for reuse etc.complete as required.
Shifting of existing Old Package AC indoor unit from Plant Room to outside the plant room etc.complete as required
Labour Charge for reinstallation of recovered Duct Damper Fire damber, Nut, Bolt, Bars, Gaskit, Fashner & canvas connection etc. complete as required.
ITC of Microprocessor based high precision Air cooled PAC type AC units i/c filling of exisitng refrigerant gas etc. complete as required.
Re-Installation of exisitng recovered copper refrigerent pipe size 7/8 & 5/8 with cutting, Gas breezing, copper elbo, copper shoket, saddling etc. complete as required.
Installation of exisitng recovered cable tray i/c painting etc. complete as required.
Supplying and fixing of copper refrigerent pipe with saddling of following size etc. complete as required.(a) 7/8" (hot gas refrigerant pipe)
(b) 5/8" (cold gas refrigerant pipe)
Recharge of R-407 gas as per requirement including testing and commissioning etc.as required.
Leak testing of copper refrigreat piping (Section and Discharge line both) with the help of Nitrogen gas holding the pressure for 24 hours including breezing etc.complete as required.
S/f 4 core 2.5 sqmm PVC insulated flexible copper cable i/c pdg PVC glands and AL. lugs, making connection etc. complete as required. From indoor unit to outdoor unit)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (a) 150 mm width X 50 mm depth X 1.6 mm thickness
(b) 100 mm width x 50 mm depth x 1.6 mm thickness
© Pdg rubber pads below the PAC units on floor etc complete as reqd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].