Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹36.1 L Quoted ₹37.3 L | L1 | Accepted-AOC Due to being L1 |
| 2 | L2₹37.6 L+₹32,748 (0.88%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹37.6 L+₹32,748 (0.88%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹41.6 L+₹4.3 L (11.6%)Rejected-Finance | ₹41.6 L+₹4.3 L (11.6%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹41.8 L+₹4.5 L (12.2%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹41.8 L+₹4.5 L (12.2%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹42.7 L+₹5.4 L (14.5%)Rejected-Finance | ₹42.7 L+₹5.4 L (14.5%) | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
11 Mar 2022, 6:00 pmClosed
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Repair/Maint/Replacement of perimeter lightings alongwith connected items and unserviceable accessories of various Gen sets under GE (Utilities) Udhampur
2022_MES_507478_1
GE/U-61/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE UTILITIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹97,000
Yes
29 Mar 2022
11 Feb 2022
14 Mar 2022
11 Feb 2022
11 Mar 2022
25 Feb 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
DWC pipe conforming to IS:14930(Part-II)/IS16205 Part -II 77 mm outer dia 06 mtr each (Bar) in trenches crossing in drain etc. for protection of UG cable complete all as specified and directed by Engr-in-Charge.
Plain cement concrete M- 7.5, (1:4:8), type D-2 (using 40mm graded crushed stone aggregates) as in foundation complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-15, type B-0 (using 12.5 mm graded crushed stone aggregates) as in coping complete all as specified and directed by Engr-in-Charge.
Supply and laying in trenches, LT underground cable, XLPE insulated, armoured, heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 16Sqmm, 4 core, multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and directed by Engr-in-Charge. Note : Necessary excavation shall be measured and paid separately under respective items of the BOQ .
Supply and erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws. Poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-37, 9.5mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height of 1.5 m and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engineer-in-Charge. Note: - Excavation, Earth Work and PCC in foundation shall be measured and paid for separately.
Post top lantern, LED, type 40 watt , 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection complete all as specified and directed by Engr-in-Charge. Make-Polycab Cat No PCGPT 01 40C or its techno commercial equivalent in Havells/CG/Wipro/Bajaj.
LED street light fitting, 45 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. Make-Polycab Cat No PCGLS C4 45W or its techno commercial equivalent in Havells/CG/Wipro/Bajaj.
LED street light fitting, 60 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. Make-Polycab Cat No PCGLS C4 60W or its techno commercial equivalent in Havells/CG/Wipro/Bajaj.
LED street light fitting, 72 Watt , 230 V , AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/wattscomplete all as specified and directed by Engr-in-Charge. Make-Polycab Cat No PCGLS C4 72W or its techno commercial equivalent in Havells/CG/Wipro/Bajaj.
LED street light fitting, 90 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. Make-Polycab Cat No PCGLS C4 90W or its techno commercial equivalent in Havells/CG/Wipro/Bajaj. Note: For item Serial no 9.00 to 13.00 (a) Brackets required for fixing of fitting are inclusive of rate quoted. (b) Necessary grouting/making good on existing surfaces in inclusive of rate quoted. (c) GI pipe of required dimensions if required at site shall be provided by the contractor.
LED flood light, 120 watt, 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge. Make-Polycab Cat No PCGLS C5 01 150W or its techno commercial equivalent in Havells/CG/Wipro/Bajaj.
LED flood light, 150 watt, 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge. Make-Polycab Cat No PCGLS C5 01 150W or its techno commercial equivalent in Havells/CG/Wipro/Bajaj.
LED flood light, 200 watt, 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant (in repair) complete with driver and lamp CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge. Make-Polycab Cat No PCGLS C5 01 200W or its techno commercial equivalent in Havells/CG/Wipro/Bajaj.
Terminal box made out of SMC with hinged door and locking arrangements of size 140x140x95mm (in repair) including Backlite 4 way connector,M.S. Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer ,electrical connections including MCB SP 6-32 Amps complete all as specified and as directed by Engr-in-Charge. Make - Sintex product code No GSJB-1414 or its techno commercial equivalent in Havells/CG/Pplycab/Bajaj.
Pole mounted junction box (Street light box) sliding type doors fits to base by 3 phase busbar insulator - 04 Nos (in repair) for street lighting system with nuts and bolts with fixing arrangment, outdoor type of dismension 240 x 130 x 110 mmwith suitable screen printed skull and bones for danger notice on middle and top cover of the box complete all as specified and directed by Engr-in-Charge. Make - Sintex product code No GSJB-2817or its techno commercial equivalent in Havells/CG/Pplycab/Bajaj.
Two single core PVC insulated and sheathed copper conductor cable (in repair) 2.5 Sqmm nominal size and one single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size for earth continuity from main lines to the street light fittings after removing u/s one complete all as specified and directed by Engr-in-Charge.
Three core PVC cable (in repair), FRLS with copper conductor round cable 1.5 Sqmm for connection from juction box to street light fittings complete all as specified and directed by Engr-in-Charge.
Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including GI pipe of 75mm dia suitable for 0.4mpa working pressure complete all as specified and directed by Engr-in-Charge.
GI tubing, light, grade, 50 mm bore laind in trenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all as specified and directed by Engr-in-Charge.
Maintenance of following capacity DG sets and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter,CR element and CR plates complete with ‘O’ rings and draining of Engine oil ,coolant and topping up with the new engine oil, coolant complete all as specified and directed by Engr-in-Charge :- Note :- (i) Engine oil & coolent shall be measured and paid separately. (ii) Labour & transportation shall be arranged by contractor and quoted rate deemed to be inclusive in the unit rate. Make: KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON/MAHINDRA
DG set of capacity up to 10 KVA.
DG set of capacity above 10 KVA and up to 30 KVA.
DG set of capacity above 30 KVA and up to 63 KVA.
DG set of capacity above 63 KVA and up to 82.5 KVA.
DG set of capacity above 82.5 KVA and up to 110 KVA.
DG set of capacity above 110 KVA and up to 125KVA.
DG set of capacity above 125 KVA and up to 182.5KVA.
DG set of capacity above 182.5 KVA and up to 250 KVA.
DG set of capacity 320KVA.
DG set of capacity 415KVA.
DG set of capacity 500KVA.
Renewal/Replacement of existing unserviceable batteries with maintenance free batteries of 150 AH, 12V including connecting to DG set . Make:- EXIDE/ AMARON/LUMINAIRE
All as per serial item No 24.00 here-in-before but of 180 AH, 12V including connecting to DG set. Make:- EXIDE/ AMARON/LUMINAIRE
Attending the breakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and rectify the fault and give report to concern JE complete all as specified and directed by Engr-in-Charge. Note :- Spare Parts for rectification the faults shall be measured and paid seperately.
Renewal/ repairs of unserviceable automatic voltage regulator (AVR) upto 125 KVA DG set including all spares, testing complete all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.
Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 125KVA and upto 320 KVA DG set including all spares, testing complete all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.
Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 320 KVA and up to 625 KVA DG set including all spares, testing complete all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.
Dismantling of exhaust pipe of the DG set up to 30KVA capacity by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and replaced with new asbestos rope , well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer,welding works if required ,painting and fixing the same in its original position complete all as specified and directed by Engr-in-Charge .
All as per serial item No 28.00 here-in-before but of 40KVA to 182.5 KVA DG set.
All as per serial item No 28.00 here-in-before but of 200 KVA to 415 KVADG set.
All as per serial item No 28.00 here-in-before but of 500 KVA to 625 KVA DG set.
Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connections as per DG Set OEM recomendation, testing and commissioning complete all as specified and directed by Engr-in-Charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.
Supply only armature coil for self starter of any make, any capacity and any model 24 Volts including testing complete all as specified and directed by Engr-in-Charge.
Rewinding of field coil for self starter of 24 volts with fine enamelled copper conductor of same gauge with 'F' class insulation, size twins and weight with necessary insulating materials, guage of conductor suitable of any make, any capacity and any model complete all as specified and directed by Engr-in-Charge.
Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 12 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connection as per DG Set OEM recomendation, testing and commissioning complete all as specified and directed by Engr-in-Charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.
Supply only armature coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as specified and directed by Engr-in-Charge.
Rewinding of field coil for self starter of 12 volts with fine enamelled copper conductor of same gauge with 'F' class insulation, size twins and weight with necessary insulating materials, guage of conductor suitable for any make, any capacity and any model complete all as specified and directed by Engr-in-Charge.
Disconnecting the oil cooler of capacity up to 100 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing, opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling including refixing in its original position, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Disconnecting the oil cooler of capacity above 100kVA to 320KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing, opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling including refixing in its original position, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Disconnecting the oil cooler of above 320KVA and up to 625 kVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing, opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling including refixing in its original position, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Renewal/ replacement of existing unserviceable air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of Upto 100 KVA capacity as that of existing make and model complete all as specified and directed by Engr-in-Charge: - Make for item No.38 to 38.04: OEM recomended.
All as per serial item No 38.00 here-in-before but for the DG sets above 100 KVA and up to 182.5 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 38.00 here-in-before but for the DG sets above 182.5 KVA and up to 320 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 38.00 here-in-before but for the DG sets above 320 KVA and up to 415 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 38.00 here-in-before but for the DG sets above 415 KVA and up to 625 KVA capacity complete all as specified and directed by Engr-in-Charge.
Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities DG sets and taking down the radiator assembly by unscrewing all mechanical/electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly, cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recomendation etc., for the DG set of capacity up to 100KVA complete all as specified and directed by Engr-in-Charge:
All as per serial item No 39.00 here-in-before but for the DG sets above 100 KVA and up to 182.5 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 39.00 here-in-before but for the DG sets above 182.5 KVA and up to 320 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 39.00 here-in-before but for the DG sets above 320 KVA and up to 415 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 39.00 here-in-before but for the DG sets above 415 KVA and up to 625 KVA capacity complete all as specified and directed by Engr-in-Charge.
Renewal of battery cable leads of copper conductor and with brass lugs terminal, for the 12V, 150/180 /200 AH batteries to self stater as that of existing size and length complete all as specified and directed by Engr-in-Charge.
Renewal/replacement of 'V' belts for the DG Set Upto 100 KVA DG Set capacity as per existing size and model complete all as specified and directed by Engr-in-Charge. Make :- FENNER/ DUNLOP
All as per serial item No 41.00 here-in-before but for the DG sets above 100 KVA and up to 182.5 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 41.00 here-in-before but for the DG sets above 182.5 KVA and up to 320 KVA capacity complete all as specified and directed by Engr-in-Charge
All as per serial item No 41.00 here-in-before but for the DG sets above 320 KVA and up to 415 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 41.00 here-in-before but for the DG sets above 415 KVA and up to 625 KVA capacity complete all as specified and directed by Engr-in-Charge.
Renewal/replacement of fan belts for the DG sets Upto 100 KVA capacity as per existing size and model complete all as specified and directed by Engr-in-Charge. Make :- As per OEM Recomendation
All as per serial item No 42.00 here-in-before but for the DG sets above 100 KVA and up to 182.5 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 42.00 here-in-before but for the DG sets above 182.5 KVA and up to 320 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 42.00 here-in-before but for the DG sets above 320 KVA and up to 415 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 42.00 here-in-before but for the DG sets above 415 KVA and up to 625 KVA capacity complete all as specified and directed by Engr-in-Charge.
Renewal/replacement of Dynamo belts for the DG sets Upto 100 KVAcapacity as per existing size and model complete all as specified and directed by Engr-in-Charge. Make :- As per OEM Recomendation
All as per serial item No 43.00 here-in-before but for the DG sets above 100 KVA and up to 182.5 KVAcapacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 43.00 here-in-before but for the DG sets above 182.5 KVA and up to 320 KVA capacity complete all as specified and directed by Engr-in-Charge
All as per serial item No 43.00 here-in-before but for the DG sets above 320 KVA and up to 415 KVA capacity complete all as specified and directed by Engr-in-Charge.
All as per serial item No 43.00 here-in-before but for the DG sets above 415 KVA and up to 625 KVA capacity complete all as specified and directed by Engr-in-Charge.
Disconnecting & removing the unservicable DC wiring from DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire of existing guage wire by providing flexible pipe including making all electrical connections as per OEM recomendation for satisfactory completion of job & checking of electrical/electronic spares working condtion and testing etc complete all as specified and directed by Engr-in-Charge. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate.
Replacement of existing unserviceable water temperature gauge with new water temperature gauge for the DG set of any description including making necessary electrical /mechanical connections and taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make: OEM recomended make
Replaceemnt of existing unserviceable lubricant oil temperature gauge with new lubricant oil temperature gauge for the DG set of any capacity including making necessary electrical /mechanical connections and taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make: OEM recomended make
Replacement of existing unserviceable oil/fuel pressure gauge with new oil pressure gauge for the DG SET of any capacity including making necessary electrical /mechanical connections and taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make: OEM recomended make
Engine oil 15W/40 for toping up upto the required level and service complete all as specified and directed by Engr-in-Charge. Make :- CASTROL/ INDIAN OIL/ SERVO
Replacement of Line Voltage Monitors (LVMS) of existing make of DG set of 100 KVA to 625 KVA capacity listed parameters including testing complete all as specified and directed by Engr-in-Charge. Make :- OEM recommended
Replacement of Line Voltage Monitors (LVMS) of existing make of DG set capacity up to100 KVA capacity listed parameters including testing complete all as specified and directed by Engr-in-Charge. Make :- OEM recommended
Drain out the fuel from the fuel tank of DG set of any size/capacity and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements ccomplete all as specified and directed by Engr-in-Charge.
Replacement of Rectifiers of existing Make of DG Set of 100 KVA to 625 KVA capacity with all listed parameters including testing complete all as specified and directed by Engr-in-Charge.
Replacement of Rectifiers of existing Make of DG Set capacity up to 100 KVA capacity with all listed parameters including testing complete all as specified and directed by Engr-in-Charge.
Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling, lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable for same existing size/guage & reconnecting the same, refixing back in original position including making all necessary electrical/mechanical connections, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Removing the defective charging dynamo of capacity 12 Volt DC any make, model, any capacity and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling, lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/guage & reconnecting the same, refixing back in original position including making all necessary electrical/mechanical connections, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Replacement of unserviceable spares for water manifold and Radiator spares upto 63 KVA DG set complete all as specified and directed by Engr-in-Charge for the following spares:- (a) Radiator rubber hoses.
(b) Clamp for hump hose.
(c) Hose clamps.
(d) hump hose.
Replacement of unserviceable spares for water manifold and Radiator spares above 63 and upto 182.5 KVA DG set complete all as specified and directed by Engr-in-Charge for the following spares:- (a) Radiator rubber hoses.
(b) Clamp for hump hose.
(c) Hose clamps.
(d) hump hose.
Replacement of unserviceable spares for water manifold and Radiator spares above 182.5 KVA and upto 320 KVA DG set complete all as specified and directed by Engr-in-Charge for the following spares:- (a) Radiator rubber hoses.
(b) Clamp for hump hose.
(c) Hose clamps.
(d) hump hose.
Replacement of unserviceable spares for water manifold and Radiator spares above 320 KVA and upto 625 KVA DG set complete all as specified and directed by Engr-in-Charge for the following spares:- (a) Radiator rubber hoses.
(b) Clamp for hump hose.
(c) Hose clamps.
(d) hump hose.
Inhibitor corrosion (coolant additive concentrate) required for top up (TVS Make) complete all as specified and directed by Engr-in-Charge.
Supply and topping up of acid mixture suitable for lead acid batteries of 12 volts complete all as specified and directed by Engr-in-Charge.
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as specified directed by Engr-in-Charge.
Battery brass terminal and jelly complete all as specified and directed by Engr-in-Charge.
Remove the fuel injection pump from the engine, transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares including bringing back and refixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity up to 63 KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for up to 63KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Supply only barrel and Plunger for up to 63KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Supply only FIP Bearing for up to 63KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Remove the fuel injection pump from the engine, transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares including bringing back and refixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 63 KVA and upto 182.5KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for above 63 KVA and upto 182.5KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Supply only barrel and Plunger for above 63 KVA and upto 182.5KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Supply only FIP Bearing for above 63 KVA and upto 182.5KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Remove the fuel injection pump from the engine, transport to an authorized service centre for service, calibration and to adjust by replacing the following unservicable worn-out spares with new appropriate make minor spares including bringing back and refixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 182.5 KVA and upto 320KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for above 182.5 KVA and upto 320KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Supply only barrel and Plunger for 182.5 KVA and upto 320KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Supply only FIP Bearing for above 182.5 KVA and upto 320KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Remove the fuel injection pump from the engine, transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares including bringing back and refixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 320 KVA and upto 625KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for above 320 KVA and upto 625KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Supply only barrel and Plunger for above above above 320 KVA and upto 625KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Supply only FIP Bearing for above above 320 KVA and upto 625KVA capacity DG set complete all as specified and directed by Engr-in-Charge.
Self starter Motor, 24 volts, suitable for existing DG set above 82.5 KVA to 500 KVA capacity including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as specified and directed by Engr-in-Charge. Make :- LUCAS or its equivalent make approved by OEM of DG set.
Self starter Motor, 12 volts, suitable for existing DG set capacity up to 82.5 KVA including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as specified and directed by Engr-in-Charge. Make :- LUCAS or its equivalent make approved by OEM of DG set.
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity up to 125 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as specified and directed by Engr-in-Charge.
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity above 125KVA and up to 500 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as specified and directed by Engr-in-Charge.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable for DG Set of capacity 125 to 625 KVA including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable to DG Set of capacity up to 125 KVA including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity up to 125 KVA including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity above 125KVA up to 625 KVA including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Repairs to Alternator of following DG Sets, transporting the same to the OEM authorised service center/work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing complete all as specified and directed by Engr-in-Charge:- Note: Copper winding material will be measured and paid seperately under relevant Item
DG set Upto 100 KVA capacity.
DG Set of capacity 100KVA to 125 KVA.
DG Sets of capacity 125 KVA to 320 KVA.
DG Set of capacity 320 KVA to 400 KVA.
Supply only High conductivity copper conductor winding material including necessary insulation material required complete all as specified and directed by Engr-in-Charge.
Taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from for the following DG sets, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same including testing complete all as specified and directed by Engr-in-Charge:-
DG Sets of capacity up to 82.5 KVA.
DG Sets of capacity100 KVA to 182.5 KVA.
DG Sets of capacity 182.5 KVA to 250 KVA.
DG Set of capacity 250KVA to 400 KVA.
DG Set of capacity 400 KVA to 625 KVA.
Dismantling & disconnecting all connection of the cylinder heads from diesel engine and sent to OEM authorised Service center for calibration and repairs by replacing the spares such as Valves, Value Guides, Valves seats and repairs kit and re-assembling to its original position with necessary Engine cylinder head gasket and O rings for the following capacities including testing complete all as specified and directed by Engr-in-Charge:-
DG Sets of capacity 7.5 KVA to 40 KVA.
DG Sets of capacity 40 KVA to 82.5 KVA.
DG Sets of capacity 100 KVA to 182.5 KVA.
DG Sets of capacity 182.5 KVA to 250 KVA.
DG Sets of capacity 250KVA to 400 KVA.
DG Sets of capacity 400 KVA to 625 KVA.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as specified and directed by Engr-in-Charge. Note:- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
Replacement of microprocessor based control unit suitable to DG set controlls/commands of 100 KVA to 320 KVA capacity with all listed parameters as per recomendation including testing complete all as specified and directed by Engr-in-Charge.
Replacement of microprocessor based control unit suitable to DG set controlls/commands of 400 KVA to 625 KVA capacity with all listed parameters as per OEM recommendation including testing complete all as specified and directed by Engr-in-Charge.
On load change over switch, 630 Amps capacity, suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make:- Havells/L&T//HPL. Note for item no.83.00 to 88.00: (i)These items shall be executed immediately as and when required basis.
On load change over switch, 400 Amps capacity, suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make:- Havells/L&T/Standard/HPL
Supply and mounting AVM(anti vibration) pads for Engine,radiator and alternator of DG set of any capacity including labour charges for proper mounting and all necessary misc accessroies complete all as specified and directed by Engr-in-Charge.
Door hinges suitable for existing DG set including removing old un seviceable one complete all as specified and directed by Engr-in-Charge.
Single core, copper cable,120sqmm to 150 sqmm, 1100 Volt suitable for existing DG set including removing old unserviceable one complete all as specified and directed by Engr-in-Charge.
Copper lugs 120 sqmm to 150 sqmm suitable for 1100 Volt copper cable suitable for existing DG set including removing old unserviceable one complete all as specified and directed by Engr-in-Charge.
Notes for all items :- (a) Daily Collecting of complaints from JE/AGE is responsiblity of Contractor. After collecting Complaints from Complaint Register/Break down attending register duly signed by JE/Engr-in-Charge and contractor and Insturction by JE by Phone/SMS, complaint should be completed within 48 Hours of complaint receiving, Major complaints/AMF panel wiring/Rewinding etc items should be completed within 05 days. (b) Minimum 01 Technician with all tools, ladder and testing Equipment, as per the site requirement shall be provided by contractor. (c) Every month complete testing for serviceablity of DG Set for all Generator shall be done and reports shall be submitted to Engr- in -Chage at the end of every month (if items required shall be paid under relevant items given above). (d) Documents required for complaints like Stationery, Complaint Register, Slips & Site Order Book shall be provided by the contactor. (e) safety precautions shall be responsiblity of the contractor. (f) Contractor to comply all the respective notes of Particular Specifications attached.
MOHAN LAL AND SONS
NAVYUG TRADERS
FANGALIA TRADERS
HIMALAYA ENTERPRISES
DAVINDER SINGH
proach associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .