Tender Value
₹11 L
EMD Value
₹22,000
Closing Date
13 May 2024, 6:00 pmClosed
CWE NAGPUR
Commander Works Engineers Bldg No. P-9, Sitabuldi Fort, Nagpur-440 001 Pin-900419, C/o 56 APO
PROVISION OF BOREWELL WITH 5 HP SUBMERSIBLE PUMP AND CONNECTED UPVC DISTRIBUTION PIPE LINE FOR GARUDA TRAINING AREA UNDER GRC KAMPTEE
2024_MES_649052_1
84829/E8
Open Tender
Civil Works - Water Works
Item Rate
120 days
GE KAMPTEE
As per Tender Document
7 documents required · 7 mandatory
₹500
Yes
GE KAMPTEE
₹22,000
Yes
18 Jun 2024
3 Apr 2024
14 May 2024
3 Apr 2024
13 May 2024
24 Apr 2024
Amount
BOREWELL
Material and labour for Trial bore of 150 mm dia upto 60 meter depth below ground level in any kind of soil strata including hard stone/ boulder etc. including electric logging, MS cap, MS Flat iron clamps, reducing socket etc complete all as specified and directed.
Development of trial bore by reaming in following step:—
Material and labour for reaming/ widening of bore up to 525mm for borewell of 60 RM from ground level including casing pipe of 150mm dia and thickness 8mm, confirming to IS 3589- 2001 code including pea gravel of size 3.0mm to 6.0mm complete if found sand strata complete all as specified and directed.
Material and labour for reaming/ windening of bore up to 525mm for borewell of 60 RM including slotted pipe of size 150mm and thickness 8mm, confirming to IS 3589- 2001 code including pea gravel of size 3.0mm to 6.0mm complete if found sand strata complete all as specified and directed.
Material and labour for devlopment of bore well by means of DTH machine followed by high capacity compressor to its optimum yield till clear water of potable quality, free from sand/ slit is obtained including draw down performance and yield test of tube well complete all as specified and directed.
Material and labour for subsequent development of borewell by submersible pump set of suitable capacity till clear water of potable quality free from sand/slit is obtained complete all as specified and directed.
Material and labour for carrying chemical / bacteriological analysis and potable test of water obtained from borewell from Govt approved Micro Engineering and testing Lab complete all as specified and directed.
Material and labour for yield test of bore well by continuous pumping for 12 hours spell to determine safe pumping yield (V notch method) complete all as specified and directed.
Supply & lowering and fixing GI medium grade column pipe 50mm nominal bore of thickness 4mm in to bore hole, both side flanged 10mm thick duly welded including nut, bolts & washers and rubber gasket of suitable size complete all as specified and directed
Supply & lowering and testing and commissioning of submersible set multi stage with electric driven motor of minimum capacity 5 HP, 1.5 LPS discharge at 100m head 3 phase 415 volt, 50 Hz, AC including submersible cable and starter complete all as specified and directed
Supply and fix 150mm dia bail plug, fixed and welded complete all as specified and directed
Supply, install and commissioning of suitable 3 phase starter for 5 HP submersible pump complete all as specified and directed.
Supply and laying of 6 Sqmm x 3 core PVC insulated, PVCsheathed, unarmoured heavy duty stranded copper conductor cable, 1100 volt grade for submersible pump complete all as specified and directed.
Supply and laying mild steel well cap suitable for 150mm dia casing pipe with 4 Nos 18mm dia nuts, bolts and washers, MS clamp fabricated from flat iron 100 x 16mm thick duly drilled holes of suitable size including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDEP) pipe for laying of Electric cable of size 50mm outer diameter and 38 mm inner diameter with IS 14930 (part 2) 2001 and 6mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
Supply & laying testing LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) laid in trenches and through ducts with aluminium conductor 1100 Volt Grade of size 50 Sqmm, 3.5 core including testing complete all as specified and directed.
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
S&F sluice valve, 50 mm bore, flanged and drilled type PN-1.6, ISI marked complete all as specified and directed.
Supply and fix Non-return sluice valve size 65mm complete all as specified and directed.
DISTRIBUTION LINE
Supply and fix unplasticized PVC pipes of size 40mm of pressure rating 10 Kg/ sq cm laid in trenches complete all as specified and directed.
Supply and fix unplasticized PVC pipes of size 25mm of pressure rating 10 Kg/ sq cm laid in trenches complete all as specified and directed.
Excavation in tranches for laying of cable trench, pole and stay foundation not exc. 1.5m wide and not exc. 1.5 m in deep in any soft/loose soil and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering & well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for Rotational mouded polyethylene water storage tanks of capacity 2000 Ltrs (cylinderical vertical with closed top) hoisted and fixed in position as specified in SSR Part-I complete all as specified and directed.
Supply and fixing 1 HP pressure booster pump single phase 230V, 50 Hz & 10-76 LPM discharge, 12-42 mtrs head with automatic pump controller pressure tank of capacity 24 ltrs, in-built thermal over load protector complete all as specified and directed.
Supply and fix gun metal gate valve with iron wheel head, screwed both ends for iron pipe and fixed to 25mm bore complete all as specified and directed.
Supply and fix gun metal gate valve with iron wheel head, screwed both ends for iron pipe and fixed to 40mm bore complete all as specified and directed.
Supply and fix MCB single pole 240 volt, 6 to 40 amps, 10 KA complete all as specified and directed.
Material and labour for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20mm medium grade concealed in wall of the size 2 x 2.5 sqmm with earth wire of 1 x 2.5 sqmm complete all as specified and directed. Note:- Accessories for point / sub main wiring like PVC junction box, bend, tee, elbow shall be of same make.
M/S. ELECTROPOWER TECHNOLOGIES
chronicle enterprises
Bidder Name
chronicle enterprises
M/S. ELECTROPOWER TECHNOLOGIES
SONA LAKSHMI ASSOCIATE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .