Worley on behalf of Ms Hindustan Petroleum Corporation Limited (HPCL) invites bids through e-tendering
20000389-HD-10120
20000389-HD-10120
Open Tender
Two Bid
Siddipet, Telangana
₹0
Exempted
2 Feb 2021
12 Jan 2021
2 Feb 2021
2 Feb 2021
12 Jan 2021 - 20 Jan 2021
19 Jan 2021
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | S&I OF 100W LED EXD FLD | S&I OF 100W LED EXD FLD — Supply, Installation, Testing and Commissioning of Flameproof type (suitable for Ex-d, Zone-1&2, Gas grp IIA/IIB, Temp. class T3), 240V, 1ph, 50Hz, 100W, LED, pole mounting, integral floodlight fixture with flameproof junction box & flameproof control gear box complete with lamps, housing, reflectors, flameproof glands, metallic plugs etc. and all other accessories as required at sitE for pigging area. The Lumens output of the fixture shall be min. 8500 and BALIGA make, model type: FLPW-2595L LED 100W or any other equivalent model and make.Supply of above material with all accessories as per approved drawings, layouts, specifications, datasheets, approved vendor list etc. including the transportation upto the site/yard, unloading, storage at site and including supply of installation material as per installation details with any additional material as per actual site requirement and/or instructions of site-in-charge etc. so as to ensure the completeness of installation work. CONTRACTOR shall be responsible for selection and supply of exactly suitable material as per the layouts, datasheets, specifications and actual site conditions for safe and standard installation. Note that the quantities are tentative and shall be supplied based on IFC (Issued for Construction) documents and actual site requirements.Receiving, handling, loading, unloading, unpacking, transporting equipment / accessories from storage point or any other location within the project site, alignment, assembling of various parts, inter-connections, grouting of fixing bolts & other associated work (including cutout in the false ceiling, chipping of concrete, making it good etc.) and Installation, testing and commissioning under the supervision of HPCL / WP of following lighting and small power equipment. Rate shall include mounting of fixture along with its accessories like chokes, condensers, reflectors, control gear boxes and lamps, checking of internal wiring. All consumables such as ball and socket, hanger rods, lugs, glands, GI chains, hardwares, anchor-fasteners etc. are in the scope of the contractor. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge. | - | Each |
| 2 | S&I OF 8M EXD FLOOD LTG | S&I OF 8M EXD FLOOD LTG — Supply, Installation, Testing and Commissioning of Hot dip galvanized, Octagonal type, flood lighting pole of 8 mtr height, suitable for mounting of 4 nos of 100W LED flameproof type flood lighting fixture (along with JB and control gear box) including external mounted 415 V, 3ph+N, 50 Hz, 4 Way, Flameproof(Ex'D'), IP55, Die cast Aluminium Alloy, junction box suitable for Zone 1, IIA/IIB, T3 area and 4 nos. 4C x 10mm² 2XWY cable entries with 2 nos. blanking plugs, including cabling within pole, baseplate with anchor bolts and nuts, all accesories like glands etc. as per tender documents. Cable sizes to be confirmed during detail engineering. Poles shall be hot dip galvanised to 610 gms per sq.m.Supply of above material with all accessories as per approved drawings, layouts, specifications, datasheets, approved vendor list etc. including the transportation upto the site/yard, unloading, storage at site and including supply of installation material as per installation details with any additional material as per actual site requirement and/or instructions of site-in-charge etc. so as to ensure the completeness of installation work. CONTRACTOR shall be responsible for selection and supply of exactly suitable material as per the layouts, datasheets, specifications and actual site conditions for safe and standard installation. Note that the quantities are tentative and shall be supplied based on IFC (Issued for Construction) documents and actual site requirements.Receiving, handling, loading, unloading, unpacking, transporting equipment / accessories from storage point or any other location within the project site, alignment, assembling of various parts, inter-connections, grouting of fixing bolts & other associated work (including cutout in the false ceiling, chipping of concrete, making it good etc.) and Installation, testing and commissioning under the supervision of HPCL / WP of following lighting and small power equipment. Rate shall include mounting of fixture along with its accessories like chokes, condensers, reflectors, control gear boxes and lamps, checking of internal wiring. All consumables such as ball and socket, hanger rods, lugs, glands, GI chains, hardwares, anchor-fasteners etc. are in the scope of the contractor. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge. | - | Each |
| 3 | S&I OF 70W LED STREET LGT | S&I OF 70W LED STREET LGT — Supply, Installation, Testing and Commissioning of Industrial type, Weatherproof, IP55(Min.), 240V, 1ph, 50Hz, 70W, LED, suitable for pole mounting, integral street light fixture with junction box & control gear box complete with lamps, housing, reflectors, glands, metallic plugs etc. and all other accessories as required at site. The Lumens output of the fixture shall be min. 7400 lumens and PHILIPS make model type: BRP410 LED 074 CW HE MR FG S2 PSU GR or any other equivalent model and make.Supply of above material with all accessories as per approved drawings, layouts, specifications, datasheets, approved vendor list etc. including the transportation upto the site/yard, unloading, storage at site and including supply of installation material as per installation details with any additional material as per actual site requirement and/or instructions of site-in-charge etc. so as to ensure the completeness of installation work. CONTRACTOR shall be responsible for selection and supply of exactly suitable material as per the layouts, datasheets, specifications and actual site conditions for safe and standard installation. Note that the quantities are tentative and shall be supplied based on IFC (Issued for Construction) documents and actual site requirements.Receiving, handling, loading, unloading, unpacking, transporting equipment / accessories from storage point or any other location within the project site, alignment, assembling of various parts, inter-connections, grouting of fixing bolts & other associated work (including cutout in the false ceiling, chipping of concrete, making it good etc.) and Installation, testing and commissioning under the supervision of HPCL / WP of following lighting and small power equipment. Rate shall include mounting of fixture along with its accessories like chokes, condensers, reflectors, control gear boxes and lamps, checking of internal wiring. All consumables such as ball and socket, hanger rods, lugs, glands, GI chains, hardwares, anchor-fasteners etc. are in the scope of the contractor. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge. | - | Each |
| 4 | S&I OF 8M ST LTG POLE | S&I OF 8M ST LTG POLE — Supply, Installation, Testing and Commissioning of Hot dip galvanized, Octagonal type, decorative type street lighting pole of 8 mtr height with single decorative type arm of 1mtr length suitable for mounting of 1 nos of 70W, LED, industrial type street lighting fixture including marshalling box (Junction box) inside the pole suitable for looping of 415V, TPN, 50 Hz incoming supply including cabling within pole and including baseplate with anchor bolts and nuts.Supply of above material with all accessories as per approved drawings, layouts, specifications, datasheets, approved vendor list etc. including the transportation upto the site/yard, unloading, storage at site and including supply of installation material as per installation details with any additional material as per actual site requirement and/or instructions of site-in-charge etc. so as to ensure the completeness of installation work. CONTRACTOR shall be responsible for selection and supply of exactly suitable material as per the layouts, datasheets, specifications and actual site conditions for safe and standard installation. Note that the quantities are tentative and shall be supplied based on IFC (Issued for Construction) documents and actual site requirements.Receiving, handling, loading, unloading, unpacking, transporting equipment / accessories from storage point or any other location within the project site, alignment, assembling of various parts, inter- connections, grouting of fixing bolts & other associated work (including cutout in the false ceiling, chipping of concrete, making it good etc.) and Installation, testing and commissioning under the supervision of HPCL / WP of following lighting and small power equipment. Rate shall include mounting of fixture along with its accessories like chokes, condensers, reflectors, control gear boxes and lamps, checking of internal wiring. All consumables such as ball and socket, hanger rods, lugs, glands, GI chains, hardwares, anchor- fasteners etc. are in the scope of the contractor. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge. | - | Each |
| 5 | S&I OF 63A INDU. SKT RCPT | S&I OF 63A INDU. SKT RCPT — Supply, Installation, Testing and Commissioning of Industrial type, wall/structure mount, Ultra violet resistant, Outdoor type, IP55(Min.), Switch receptacles having 63A, 415V, 3Ph+1N+1E, 50Hz, 5 Pin socket / receptacles with plug top, 415V, 63A, 50Hz, 4P MCB+ELCB with terminal suitable for cable termination (3.5C x 35 Sq.mm Al/XLPE/SWA/PVC FRLS cable) plastic body with loop in loop out facility. Each socket shall be provided with 4 way Junction box with suitable entries, metallic plugs, glands (Suitable for 3.5C x 35 Sq.mm Al/XLPE/SWA/PVC FRLS cable) etc. and all other accessories as required at siteSupply of above material with all accessories as per approved drawings, layouts, specifications, datasheets, approved vendor list etc. including the transportation upto the site/yard, unloading, storage at site and including supply of installation material as per installation details with any additional material as per actual site requirement and/or instructions of site-in-charge etc. so as to ensure the completeness of installation work. CONTRACTOR shall be responsible for selection and supply of exactly suitable material as per the layouts, datasheets, specifications and actual site conditions for safe and standard installation. Note that the quantities are tentative and shall be supplied based on IFC (Issued for Construction) documents and actual site requirements.Receiving, handling, loading, unloading, unpacking, transporting equipment / accessories from storage point or any other location within the project site, alignment, assembling of various parts, inter- connections, grouting of fixing bolts & other associated work (including cutout in the false ceiling, chipping of concrete, making it good etc.) and Installation, testing and commissioning under the supervision of HPCL / WP of following lighting and small power equipment. Rate shall include mounting of fixture along with its accessories like chokes, condensers, reflectors, control gear boxes and lamps, checking of internal wiring. All consumables such as ball and socket, hanger rods, lugs, glands, GI chains, hardwares, anchor- fasteners etc. are in the scope of the contractor. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge. | - | Each |
| 6 | S&IOF415V,TPN12WAY,IND | S&IOF415V,TPN12WAY,IND — Supply, Installation, Testing and Commissioning of 415 V, TPN, Single front, wall mount, Industrial type, indoor, Normal lighting distribution Panel for Plant area with 1 no.63A TPN ELCB+MCB as incomer and 12nos, 16A 4P MCB as outgoing feeders. Cable sizes to be confirmed during detail engineering.Supply of above material with all accessories as per approved drawings, layouts, specifications, datasheets, vendor list etc. including the transportation upto the site/yard, unloading, storage at site and including supply of installation material as per installation details with any additional material as per actual site requirement and/or instructions of site-in-charge etc. so as to ensure the completeness of installation work. CONTRACTOR shall be responsible for selection and supply of exactly suitable material as per the layouts, datasheets, specifications and actual site conditions for safe and standard installation. Note that the quantities are tentative and shall be supplied based on IFC (Issued for Construction) documents and actual site requirements by Contractor.Receiving, handling, loading, unloading, unpacking, transporting equipment / accessories from storage point or any other location within the project site, alignment, assembling,inter-panel wiring, grouting of panel fixing bolts & other associated work (including chipping of concrete (as required) and making good) and Installation, testing and commissioning under the supervision of suppliers commissioning engineer / HPCL / WP (including loop checking of various modules / inter-panel loop checking / field loop checking) of following distribution boards. Rate shall also include all hardware required for installation and foundation bolts (as per various installation standards / good engineering practices), testing & commissioning as per site testing format, minor modifications as required in the control schematic including preparing final as built documentations, stenciling with epoxy paint of approved paint shade (as per site in charge / WP / HPCL engineer) on various / all modules / panels with relevant indentification like Tag Number / of equipment inclusive of touch up of paint (if required), all complete as per the specifications,scope of work and directions of the Engineer-in-Charge. Note that all dimensions, weights etc. are tentative and shall be finalised during detail engineering based on vendor drawings. | - | Each |
| 7 | S&I OF 415V,TPN,12WAY,IND | S&I OF 415V,TPN,12WAY,IND — Supply, Installation, Testing and Commissioning of 415 V, TPN, Single front, wall mount, Industrial type, indoor power distribution board for Non-UPS power distribution in control room consisting of 1 no. 63A 4P MCB as incomer with 12 nos. 16 A DP MCB as outgoing feeders. Cable sizes to be confirmed during detail engineering.Supply of above material with all accessories as per approved drawings, layouts, specifications, datasheets, vendor list etc. including the transportation upto the site/yard, unloading, storage at site and including supply of installation material as per installation details with any additional material as per actual site requirement and/or instructions of site-in-charge etc. so as to ensure the completeness of installation work. CONTRACTOR shall be responsible for selection and supply of exactly suitable material as per the layouts, datasheets, specifications and actual site conditions for safe and standard installation. Note that the quantities are tentative and shall be supplied based on IFC (Issued for Construction) documents and actual site requirements by Contractor.Receiving, handling, loading, unloading, unpacking, transporting equipment / accessories from storage point or any other location within the project site, alignment, assembling,inter-panel wiring, grouting of panel fixing bolts & other associated work (including chipping of concrete (as required) and making good) and Installation, testing and commissioning under the supervision of suppliers commissioning engineer / HPCL / WP (including loop checking of various modules / inter-panel loop checking / field loop checking) of following distribution boards. Rate shall also include all hardware required for installation and foundation bolts (as per various installation standards / good engineering practices), testing & commissioning as per site testing format, minor modifications as required in the control schematic including preparing final as built documentations, stenciling with epoxy paint of approved paint shade (as per site in charge / WP / HPCL engineer) on various / all modules / panels with relevant indentification like Tag Number / of equipment inclusive of touch up of paint (if required), all complete as per the specifications,scope of work and directions of the Engineer-in-Charge. Note that all dimensions, weights etc. are tentative and shall be finalised during detail engineering based on vendor drawings. | - | Each |
| 8 | S&I OF 4Cx4,2XWY,1.1KV | S&I OF 4Cx4,2XWY,1.1KV — Supply, Laying/Installation, termination, testing & commisioning of 4C x 4 sq mm 2XWY (1100V) cable (for lighting in plant). Rate shall include supply of cables, holding clamps etc.Receiving, handling, loading, unloading, unpacking, transporting from storage point or any other location within the project site, laying, glanding, lugging, termination, testing & commisioning of lighting cables of above sizes as per specification and datasheets inclusive of all consumables such as clamps for cleating of cables on surface, hardware etc., including chipping of wall/surface, installing conduit (concealed) and making wall/surface good, including the cost of all labours, material, equipment etc. complete as per approved drawings, specifications of this tender and directions of engineer-in-charge. Job includes supply and installation of Industrial glands as required with all accessories as required at site. Job includes supply and installation of Industrial type reducers and/or adapters as required at site. Job includes supply and installation of Crimping type Tinned copper/Aluminium, insulated, Pin type/Ring type lugs/heavy duty tubular/long barrel type tubular lugs for bolted connection as required at site. | - | Meters |
| 9 | S&I OF 2Cx2.5,2XWY,1.1KV CA | S&I OF 2Cx2.5,2XWY,1.1KV CA — Supply, Laying, termination, testing & commisioning of 2Cx2.5 Sq.mm, 2XWY,1.1kV, FRLS CableSupply of Copper conductor, XLPE insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured, FRLS power cables including transportation to yard/site, unloading, Storage at site as per datasheet, specifications of this tender and as per approved vendor list. These quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanantely installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Receiving, handling, loading, unloading, unpacking, transporting from storage point or any other location within the project site, laying, termination, testing & commisioning of copper conductor, XLPE insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured power cables of above size as per specification including supply & spreading of approved fine river sand in cable trenches, approved second class bricks of 75mm thickness in cable trenches for cable protection laid lengthwise inclusive of all consumables such as clamps including trefoil clamps at every 3 meters for 1C cables, cable tags (cable tags at every 30m and on bents), hardware, trefoil clamps etc. including supply and installation of cable markers for underground cable routes (including transportation upto Site/Yard, unloading & storage at site), including excavataion of soil up to the required depth, installation of cables, back filling and compacting of soil and disposing the excess soil etc. including supply and installation of suitable GI pipes from buried trench to the equipment as per installation details and IFC layouts including supply and installation of crimping type tinned copper/Aluminium, Pin type/Ring type lugs/heavy duty tubular/long barrel type tubular lugs for all cable sizes as mentioned above and as required at site (including transportation upto Site/Yard, unloading & storage at site) including the cost of all labours, material, equipment etc. complete as per approved drawings, specifications of this tender and directions of engineer-in-charge. | - | Meters |
| 10 | S&I OF 2Cx10,2XWY,1.1KV | S&I OF 2Cx10,2XWY,1.1KV — Supply, Laying, termination, testing & commisioning of 2Cx10 Sq.mm, 2XWY,1.1kV, FRLS CableSupply of Copper conductor, XLPE insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured, FRLS power cables including transportation to yard/site, unloading, Storage at site as per datasheet, specifications of this tender and as per approved vendor list. These quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanantely installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Receiving, handling, loading, unloading, unpacking, transporting from storage point or any other location within the project site, laying, termination, testing & commisioning of copper conductor, XLPE insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured power cables of above size as per specification including supply & spreading of approved fine river sand in cable trenches, approved second class bricks of 75mm thickness in cable trenches for cable protection laid lengthwise inclusive of all consumables such as clamps including trefoil clamps at every 3 meters for 1C cables, cable tags (cable tags at every 30m and on bents), hardware, trefoil clamps etc. including supply and installation of cable markers for underground cable routes (including transportation upto Site/Yard, unloading & storage at site), including excavataion of soil up to the required depth, installation of cables, back filling and compacting of soil and disposing the excess soil etc. including supply and installation of suitable GI pipes from buried trench to the equipment as per installation details and IFC layouts including supply and installation of crimping type tinned copper/Aluminium, Pin type/Ring type lugs/heavy duty tubular/long barrel type tubular lugs for all cable sizes as mentioned above and as required at site (including transportation upto Site/Yard, unloading & storage at site) including the cost of all labours, material, equipment etc. complete as per approved drawings, specifications of this tender and directions of engineer-in-charge | - | Meters |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
20000389-HD-10120.pdf
TENDER_DOCUMENT • 39.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .