Executive Engineer (Elec),PWD.,Electrical Division
OFFICE OF THE EXECUTIVE ENGINEER (ELECTRICAL), PWD., Electrical Division, Tirunelveli.
Renewal of 2 Nos 2.0 TR Airconditioner units to the Component Separation Room at Blood Bank building in Kanniyakumari Govt. Medical College Hospital at Asaripallam in Kanniyakumari District.
2026_PWD_709696_1
7(20)EE/2026-27 dated.30.09.2026
Open Tender
Electrical Works
Lump-sum
30 days
Asaripallam
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1,400
1 Oct 2026
1 Oct 2026
16 Oct 2026
1 Oct 2026
15 Oct 2026
1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Renewal by Supply and Installation of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of | 2 | Nos | 46,140 | ₹92,280 |
| 1.01 | Cooling
Dehumidifying
Air Circulating
Filtering
The installation works for the above split type AC units includes the following.
1.Mounting/Fitting Indoor and outdoor units at their respective locations.
2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required.
3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing.
4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.
5. Leakage testing the entire system unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit up to switch within 3 Meters of location of indoor unit (Carrier/Voltas/ O General) (Blood Bank ) | - | - | - | - |
| 2 | Renewal by Supply and Installation of 5KVA Capacity Electronic Automatic Voltage Stabilizer V-GUARD make VGS 500 Model with Input Voltage range of 170Volt- 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. | 2 | Nos | 4,646 | ₹9,292 |
| 3 | Renewal by Supply and fixing of MS stand for fixing Outdoor unit. | 2 | Nos | 979 | ₹1,958 |
| 4 | Renewal bySupply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) | 8 | Mtrs | 980 | ₹7,840 |
| 5 | Renewal by Supply and fixing of water drain pipe line | 20 | Mtrs | 58 | ₹1,160 |
| 6 | Removal of AC and its Accessories and Transportation Charges from work site to section office. | 1 | Job | 708 | ₹708 |
| 7 | GST | 1 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.84 MB
TNO122.pdf
Tender Documents • 0.79 MB
BOQ_852759.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .