Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹22.0 L+₹3.5 L (19.1%)Rejected-Finance | L2 | Rejected-Finance Highest bidder | |
| 3 | L3₹22.8 L+₹4.4 L (23.7%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L3 | Rejected-Finance Highest bidder | |
| 4 | L4₹23.4 L+₹5.0 L (26.9%)Rejected-Finance | L4 | Rejected-Finance Highest bidder | |
| 5 | L5₹25.9 L+₹7.5 L (40.6%)Rejected-Finance 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L5 | Rejected-Finance Highest bidder |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
9 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Bamrauli
GE AF Bamrauli
PROVN ADDITION ALTERATION BUILDING NO P937 AND CERTAIN SANCTIONED WORKS AT BAMRAULI
2020_MES_378496_1
8603/E8
Open Tender
Civil Works
Item Rate
180 days
Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Bamrauli
₹38,000
Yes
15 Oct 2020
17 Sept 2020
10 Oct 2020
17 Sept 2020
9 Oct 2020
3 Oct 2020
60 days
Amount
S & F mild steel work in tubular trusses incuding special shaped washer etc complete using ERW Welding or induction butt welded tubes conforming to IS 1161 1979 grade st 240 complete all as specified and as directed.
S&F preppainted galvalume aluminum zinc coating GI based corrugated steel sheeting 0.50mm thick of any colour havingtensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M & L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer of any description over 10 cm in width or grith, not otherwise described including complete all as specified and as directed.
Taking down Chowkats or frames with shutter exceeding1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frames) complete all as specified and as directed.
S&F 150mm, long, aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed.
S&F 150 mm long , aluminium handles cast type, anodised and fitted complete all as specified and as directed.
S&F for powder coated anodised aluminium frames for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. (minimum thickness of powder coating 50 micron) complete all as specified and as directed.
S&F powder coated anodised aluminium sliding glazed windowshutter of size as shown in drawing with necessary joining cleats, glazing clips, rubber gasket, aluminium snap beading and locking arrangement at both ends complete all as specified & directed and as shown and drawing CE/ALD/TD-194 sheet No. 1/2 & 2/2. Notes : (i) Glazing will be measured and paid separately under relevant item of schedule 'A'. (ii) Thickness of powder (epoxy polyster) coating shall not be less than 50 Micron (iii) Shade/tint of powder coating (epoxy polyster) shall be as approved by GE. (iv) Weight of aluminium sections shall not be less than 0.55 Kg/m
S&F powder coated anodised aluminium glazed door shutter of size as shownin drawing with necessary joining cleats, glazing clips, rubber gasket, aluminium snap beading and locking arrangement at both ends complete all as specified & directed and and as shown and drawing CE/ALD/TD-194 sheet No. 1/2 & 2/2. Notes :(i) Glazing will be measured and paid separately under relevant item of schedule 'A' (ii) Thickness of powder (epoxy polyster) coating shall not be less than 50 Micron (iii) Shade/tint of powder coating (epoxy polyster) shall be as approved by GE. (iv) Weight of aluminium sections shall not be less than 0.55 Kg/m.
S&F 5.50mm thick coloured sheet glass, best quality and glazing with aluminium clips in square exc 0.5 sq. m in each pane complete all as specified and directed.
S&F for 9mm thick prelaminated particle board exterior grade prelaminated both sides with decorative choice laminations fixed with screws to aluminium door etc complete all as specified and directed.
S&F Stainless steel concealed door closer in floor mounted best quality, suitable for door shutters of 851 to 1000 mm in width and (overall length of cover plate) 140mm etc ccomplete all as specified and directed.
S&F rebated mortice aluminium lock verticle type size 100mm with 4 levers complete all as specified and directed.
M&L for 16-18 mm thick granite (any type) work (table rubbed and polished) in steps, jambs, cooking platform and like and fixed with cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for silicon filling of any depth and width to arrest the leakage through alluminium frames and concrete surfaces complete all as specified and directed.
M&L for 100 mm thick PCC 1:3:6 type C-2 (using 20mm graded crushed stone aggregate) as plinth courses complete all as specified and as directed.
M&L for obtaining clean soil/approved earth from out side MOD land including leveling , spreading and ramming in layers manually with manual comapctors, each layer not excceidng 25 cm after compaction and spreaded up to a height of 3.5 mtrs complete all as specified and directed.
S&F Soild PVC wall lining/panelling consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing on PVC frame complete all as specified and directed by the Engineer-in-Charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive fixing on wall to make PVC frame etc complete all as per specified and directed.
Taking down cement plaster/terrazzo on brick or stone wall surfaces etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by the Engineer-in-Charge.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth (Without using extra cement) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil-emulsion over a coat of alkali resistant primer with a thin layer of 3 mm thick wall care putty complete all as specified and directed.
S&F PVC cabinet frame of size 18 mm x 75 mm made out of 18 mm thick PVC board, wood grain colour and frame shall be fixed with 50 mm long steel screw inside using drilling machine and plastic fasteners complete all as specified and directed.
S&F PVC cabinet box and shutter made out of 18 mm thick one side PVC prelaminated wood grain board and shutter shall be fixed on the PVC frame with two auto hinges and steel screw including fancy type stainless steel handles complete all as specified and directed.
Excavation in trenches/pits in any type of soil (Soft/loose or hard/dense soil) not exc 1.5 m wide and not exc 1.5 m in depth and getting out complete for AFLS cable as per requirement AF,manually with one trades man and helper on daily basis (as and when required) during the contract period complete all as specified and directed.
Returning filling in (with the earth obtained from above) including spreading, levelling, watering and well ramming in layer not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing of surplus excavated materials to a distance not exceeding 50 m and dpositing at a level not exceeding 1.5 m from starting point complete all as specified and directed.
Supply and spread clean river sand as cable cushioning for proctection of cable to be laid in trenches all as per SSR Part-I complete all as specified and directed by the Engineer-in-Charge. Note: Punned depth will be measured and paid.
Supply, laying, jointing & testing of 4 core 25 Sqmm underground LT cables XLPE insulated, PVC sheathed, aluminium conductors, multistranded, armoured heavy duty 1100 Volt grade cross sectional area fixed on wall/floor/roof with MS clips complete all as specified and directed.
S&F MCCB 100 Amps, 4 pole, fixed type, breaking capacity 16 KA at 415 volts , 50 HZ with Sheet Metal encloure for fixing on wall including necessary connection complete all as specified and directed.
S&F vertical TPN distribution board with MCCB incomer, 8 way , confirming to IS 8623-1&3 , IEC 61439- 1&3,IP -43 including neutral and earth link ,double door type front opening 415 volt 50 Htz complete all as specified and directed. Note:- MCCB, MCB will be measured and paid separately under respective items of Schedule 'A'.
M&L Sub main wiring with 3 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 16 sqmm , 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of suitable size including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 10 sqmm 1100 volts grade cable continuous earth wire of green colour code complete. Notes:- (a) Three runs of 16.00 sqmm cable and one run of 10 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment(b) Quoted rate shall deemed to be inclusive of cost of cutting chases in wall for concealed conduit and making good to match with existing surfaces/finish.
S&F MCCB, four pole, 415 Volt ,100 Amp rating, adustable type, 25 KA ultimate breaking capacity complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs complete all as specified and directed.
M&L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm , 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of suitable size including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 2.5 sqmm 1100 volts grade cable continuous earth wire of green colour code complete. Notes:- (a) Two runs of 4.00 sqmm cable and one run of 2.5 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deemed to be inclusive of cost of cutting chases in wall for concealed conduit and making good to match with existing surfaces/finish.
S&F AC starter unit consisting of one 25 Amp capacity starter, one MCB SPN, 25 Amp, 240 volt,10 KA, one 25 Amp sockets and one 25 Amp plug top prewired complete all as specified and directed.
M & L for point wiring with PVC insulated, PVC unsheathed cable single core, nominal area 1.5 sq mm with stranded copper conductor 1100 volts grade drawn into and incl rigid PVC conduit (concealed) 19 mm internal dia with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sq mm unsheathed copper conductor earth wire connected to earth dolly with sunken box for Modular fiiting in wall with brand sheet cover (white) for mounting of switches, sockets and regulators as required complete all as specified and directed for one 3 pin 5 amp switch socket out let independent . Note :- (a) The rate for cutting chases on wall for concealed conduit and steel terminal boxes is deemed to be included in the unit rate quoted.(b) Colour code of wire shall be strictly followed (Red for Phase , Black for neutral and green for earth wire)
S&F modular switch 1 Way 6 A module complete all as specified and directed.
S&F modular switch socket 6 A -2/3 pin combined 2 module complete all as specified and directed.
S & F ceiling rose, suface bakalite, three terminals complete all as specified and directed.
S&F fresh air fan, AC, single phase 230 volts of size 250 mm sweep, plastic body with louvers and making of hole on Glass window , & grouting nut & bolts and connecting with 3 run of 1.5 sqm, single core, PVC insulated mulstistranded copper conductor cable from ceiling rose and making good the disturbed surface with existing colour matching complete all as specified and directed. Make:- Havells Cat part No. Ventil Air DX or equivalent model of make as specified in Appendix B to particular specifications. Note:- Cutting the window's glass and fixing making aluminium frame as required for fixing the fan, the unit rate quoted is deemed to be inclusive of the same.
Supply, installation,testing & commissioning of Tripod Chemical Earthing (i.e. Three chemical earthing are indvidually connected in Delta form through copper strip )which include: (i) Three No's 3000 mm long 50mm dia copper bonded rod with top removal compound filling cap, seepage holes, stainless steel fasteners, HDPE Lockable earth pit cover cum inspection chamber along with 150 Kg of Earth Enhancement Back fill compound compound including digging of pits. (ii) Copper earthing strip 25x3 mm for interconnection of all three pits along with necessary clamps. (iii) Any other accessories including design modifications, to achieve the required earth termination rod resistance value below 1 ohms or as per the OEM / International Standard recommendation. Make: Aes Gel Eathing solutions/ Indelec/Tercel/ Erico .
S& F Earth continuity conductor 25x3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etccomplete all as specified and directed.
Fixing only split units indoor and outdoor units of 1.5 ton capacity all as required including necessary connections complete all as specified and directed . Note : Split AC unit (Indoor & out door) will be issued under Sch 'B'
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor/outdoor type, Built-In Thermal Overload Protection,Low & High Voltage cut-off protection & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA Make: V GUARD(Model No: VND500) / BLUEBIRD(Model No:BA514A) or equivalant model as approved by GE.
M &L for laying of copper tubing of dia 1/2" including insulation with heavy duty rubber foam and brazing work complete all as specified and as directed by Engineer-in-Charge
M &L for laying of copper tubing of dia 1/4" including insulation with heavy duty rubber foam and brazing work complete all as specified and as directed by Engineer-in-Charge
S&F PVC insulated stranded 4 core flexible copper cable of size 2.5 sqmm 1100 volt grade complete all as specified and directed by Engineer –in-Charge
S&F low density polyether pipe (LDPE) of pressure rating 6Kg/cm2 drain pipes of size 40 mm from indoor unit to exist point as per design including accessories clamps fastners complete all as specified and as directed by Engineer –in-Charge
S&F 5 rated ceiling fan, copper wound of 1200 mm sweep, 230 volts, 50 Hz, single phase complete with down rod, canopy and fan blades of suitable size complete all as specified and directed. Make : Havells Model No ES 40 NEO or equivalent model in Usha/CG/Bajaj
S&F wall mounted fans, copper wound winding of 400 mm sweep, 230 volts, 50 Hz, complete with fixing arrangements all as specified and directed. Make : Havells Model No Platina HS or equivalent model in Usha/CG/Bajaj
S&F Pedestal fans, copper wound winding of 450 mm sweep, 230 volts, 50 Hz, complete with fixing arrangements all as specified and directed. Make : Havells Model: Wind Strom or equivalent model in Usha/CG/Bajaj
S&F sheet metal enclosure with socket with two pin and earth plug, plug top and single pole MCB (240 Volt, 32 Amp) to the wall surface or making suitable size of hole in the wall to fix it whenever its required and making good the existing surface complete all as specified and directed. Make : Standerd/Indoasian/Havells
Fixing only window type air conditioner of 2 ton capacity electric driven (single phase) including making hole and frame on wall and make good the disturbed surface with cement plaster/ concrete, existing colour matching complete all as specified and directed. Note : Window AC unit will be issued under Sch 'B'
M&L for sub main wiring with Two runs of single core PVC insulated unsheathed, 1100 volts grade, copper cable 6 Sqmm stranded conductor and drawing through PVC conduit medium duty (ISI Marked) concealed with conduit accessories such as junction boxes, bends, tees etc. incuding continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 Sqmm copper conductor and connected to coommon earth dolly complete as directed including taking down old submain wiring. Notes : (i) One run of MS conduit MS conduit, two runs of cable 6 Sqmm cable (Phase + Neutral) and one run of earth wire 4 Sqmm camle shall be measured and paid as one unit. (ii) Quoted rate shall deemed to be inclusive of cost of cutting chases in wall for concealed conduit and making good to match with existing surface/finish.
HIMANSHU TRADERS
Krishna Enterprises
gangotri enteriprises
chauhan construction
Mohit Enterprises
M/S R S Traders
Ambrish Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .