| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹42.3 L+₹2.2 L (5.58%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹44.6 L+₹4.5 L (11.3%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹45.1 L+₹5.1 L (12.8%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest tenderer | |
| 5 | L5₹45.6 L+₹5.6 L (14.0%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
14 Sept 2021, 6:00 pmClosed
GE (NW) KUNJALI
DR HOMI BHABHA ROAD, NAVY NAGAR, COLABA, MUMBAI - 400 005
8416 MAINT REPAIR REPLACEMENT OF LT PANEL LT UG CABLE AND OTHER ALLIED WORKS AT INS KUNJALI INWTC BV YARD CWE COMPLEX ETC UNDER GE NW KUNJALI
2021_MES_468844_1
8416/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹96,000
Yes
9 Oct 2021
17 Aug 2021
16 Sept 2021
24 Aug 2021
14 Sept 2021
31 Aug 2021
17 Aug 2021 - 24 Aug 2021
Amount
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, indoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet,side canopy, front openable doors having aluminium bus bar of capacity 200 amps for phases and 100 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at MOC AC Plant Agnibhahu Sub Station including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 200 Amps 4pole,37 KA,Thermal magnetic - 1 Nos (Incomer) b) MCCB, 3 pole 100 Amps,18 KA,Thermal magnetic - 2 Nos (Out going) c ) MCCB , 3 Pole 32 Amps, 18 KA,Thermal magnetic - 6 Nos (Out going) d) Star delta starter for 60 HP - 02 Nos (Make : L&T/C&S/Seimens) e) Star delta starter for 10 HP - 06 Nos (Make : L&T/C&S/Seimens) f) MCB 32AMP 10KA TPN -02 Nos (Out going) g) Volt meter , digital type ,0 - 500V - 1 Nos h) Ammeter, digital type with CT's - 1 No j) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/Seimens
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, indoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet,side canopy, front openable doors having aluminium bus bar of capacity 200 amps for phases and 100 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at "B" Chal PUMP HOUSE including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 125Amps 4pole,37 KA,Thermal magnetic - 1 Nos (Incomer) b) MCCB, 3 pole 40 Amps,18 KA,Thermal magnetic - 2 Nos (Out going) c) Star delta starter for 15HP - 02 Nos (Make : L&T/C&S/Seimens) d) MCB 32AMP 10KA TPN -02 Nos (Out going) e) Volt meter , digital type ,0 - 500V - 1 Nos f) Ammeter, digital type with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/Seimens
S & F in repairs MCCB, 415 volts, 3 pole of cap 63 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4200 43 or equivalent in siemens/GE / C&S
S & F in repairs MCCB, 415 volts, 3 pole of cap 100 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4200 45 or equivalent in siemens/GE / C&S
S & F in repairs MCCB, 415 volts, Four pole of cap 100 Amps, 16 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4200 15 or equivalent in siemens/GE / C&S
S & F in repairs MCCB, 415 volts, four pole of cap 125 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4200 56 or equivalent in siemens/GE / C&S
S & F in repairs MCCB, 415 volts, four pole of cap 200 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4202 48 or equivalent in siemens/GE / C&S
S & F in repairs MCCB, 415 volts, four pole of cap 250 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4202 49 or equivalent in siemens/GE / C&S
S & F in repairs MCCB, 415 volts, four pole of cap 400 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4220 07 or equivalent in siemens/GE / C&S
S & F in repairs MCCB, 415 volts, four pole of cap 630Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4220 09 or equivalent in siemens/GE / C&S
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 41 or equivalent Cat part in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 6 way, 440 volts with 100A Copper Busbar rating 440 Amps, for each phase, 2 Neutral bar, 2 Earth bar, dust and vermin proof with provision for DPX³ 160 MCCB as incomer DP MCB/ Isolator/ RCCB/ RCBO as sub incomers and SP MCB's as outgoing etc. complete all as directed. Make - Legrand cat No 5077 51 or equivalent in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 8 way, 440 volts with 100A Copper Busbar rating 440 Amps, for each phase, 2 Neutral bar, 2 Earth bar, dust and vermin proof with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB's as outgoing etc complete all as directed. Make - Legrand cat No 5077 52 or equivalent in Siemens/GE NOTE FOR ITEM No. 11 to 13 : MCB DBs shall be concealed in wall where ever posible including cost of removing old wooden box making good the surface to match with surrounding deemed to be included in quoted rates
S & F in replacement 20 Amps Single pole and neutral enclosure with a Two Pin and earth plug and socket complete with one single pole MCB and making connections complete all as directed. Make -Legrand Cat Part No. 5078 14 or equivalent in Siemens /GE/ C&S
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make: Legrand cat No 4085 87-95 or equivalent Cat part in Seimens/C&S.
S&F MCB SPN 40-63Amps capacity, 10KA 'C' Curve 240V complete all as specified and directed. Make: Legrand cat No 4086 18-20 or equivalent Cat part in Seimens/C&S.
S&F in repairs of 0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter including suitable size of revits/nut bolts complete bending, shaping, drilling, cutting notching and all as specified and directed.
Supply and fixing in repair Ultra slim edge lit type recess mounting LED 2X2 Luminaire 36 watt and extruded aluminium housing with anti-glare diffuser provides high quality ecomonic energy saving lighting LED Luminaire suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and as directed. Make: C&S cat No LTCRSLM36WATT 2X2 or equivalent Cat part in Bajaj / Philips / Crompton
Supply and fix cable jointing STRAIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 120 to 185 sqmm 3.5 cre complete all as specified and directed. Make : Rychem/3M
Supply and fix cable jointing STRAIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 240 to 400 sqmm 3.5 cre complete all as specified and directed. Make :Rychem/3M
Supply and fix cable jointing STRAIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 95 to 120 sqmm 3.5 core complete all as specified and directed. Make :Rychem/3M
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3½ core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3½ core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3½ core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza Note for item No. 22 to 28 : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Excavation in trenches n exc1.5m wide and n exc in depth for laying of cables and getting out in loose/soft soil compete all as directed.
Returing filling in including spreading, levelling watering and well ramming in layers not exc 25cm compete all as directed.
Removing excavated material n exc 50cm and deposting where directed at a level n exc 1.5m above the starting point compete all as directed.
Material and labour for sand filling in trenches fine dry sand as sand cushioning to cable 8 cm before laying of cables and 15 cm after laying cable which shall be punned down to 10 cm complete all as specified and directed. (Note : Only punned down thickness shall be measured and paid)
Supply and layingreinforceced precast concrete cable cover, class LV type , I, flat size 250mmx150mmx40mm laid across the cable complete all as specified and directed.
M&L for GI pipe light grade 100mm dia for protection of UG cable crossing of nalha/bgrdge/road etc complete all as directed.Make : Jindal
M&L for GI pipe light grade 150mm dia for protection of UG cable crossing of nalha/bgrdge/road etc complete all as directed.Make : Jindal
M&L cement concrete in 1:2:4 type B1 using 20mm grade stone aggregate for road cutting/pole couping exposed surfaced and fair and even finishing with out using any extra cement etc complete all as specified and directed
Supply of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 32 mm dia with 250 micron (average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF ECO SAFE compound shall be supplied in 50 Pound Bag. ( 1 Bag required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied alongwith weatherproof chamber. Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
Supply and laying single Core cable of size 50 sq mm (heavy duty), 1100 Volts grade, as IS 694:1990, unsheathed, PVC Insulated and Multi Core PVC Insulated and PVC sheathed industrial cables with flexible bright annealed Copper Conductor, including making connection and taking out old damaged cable complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
M&L for Cutting road/hard standing for laying of cable and re mataling/making good the same to match the existing surface complete all as directed.
Taking down the LT ACB of capacities 630Amps to 2000Amps of any make for repairs, servicing, comprising the following & refixing the same, re-orientation & labour for taking, defective parts & refixing the same spare parts:- (a) Checking /repairs of the mechanism of ACB (b) Checking/repair of the manual closing of the breakers (c) Decarburizing, setting reassembling, cleaning adjustment of fixed contacts, main contact & chamber and applying petroleum jelly all as complete.
M&L for Decorbonising /cleaning of LT 415/380V 3 phase bus bar, bus bar chambers of feeder pillar box, electrical connection complete, ACB, switch fuse unit arrangement incoming & outgoing installed in at various location after removing the complete bus bar from the bus chamber, cleaning with CTC & insure proper decorbonising refixing the same applying backtal (red) solution to the bus bar insulator & checking all the connections & tighting the nuts & bolts thimbles of incoming & out going system complete including replacement of defective rusted bolts, nuts & washers all as specified & directed.
M&L for Decorbonising/ cleaning of ducts of HT/LT cable from various location as per following description. (a)Removing of accumulated, stanated water/oil from the duct either manually or mechanically.(b) Cleaning of cable bunch in duct of all accumulated slit/mud/debris/foreign material. (c) Removing & repositioning of RCC/MS duct covers including one coat of red oxide and one coat of black paint as required.(d) Patch civil work plastering and concreting work.
Shree Ayyappa Engineering
ASHOK ENTERPRISES
NOEL ENGINEERS
ELECTRO ASSOCIATES
Rohit Enterprises
DHARMESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .