Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC | ₹42.7 L Quoted ₹43.3 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹46.8 L+₹3.5 L (8.05%)Rejected-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | ₹46.8 L+₹3.5 L (8.05%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹47.9 L+₹4.6 L (10.6%)Rejected-Finance | ₹47.9 L+₹4.6 L (10.6%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹47.9 L+₹4.7 L (10.7%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | ₹47.9 L+₹4.7 L (10.7%) | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹48.5 L+₹5.2 L (12.0%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹48.5 L+₹5.2 L (12.0%) | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
18 Oct 2024, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT TO INTERNAL ELECTRIFICATION FITTING FIXTURE SUB MAIN WIRING MAIN DBS BLDG EARTHING AND OTHER MISC E M WORKS IN MD AND OTM ACCNS AT AFTC 2 DC AREA AND AFS JALAHALLI
2024_MES_675615_1
8969/E8
Open Tender
Electrical and Maintenance Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹1 L
21 Nov 2024
20 Sept 2024
25 Oct 2024
20 Sept 2024
18 Oct 2024
4 Oct 2024
20 Sept 2024 - 27 Sept 2024
Amount
Repair, maintenance and making the continuity of supply after rectifying the defects of the electrical items such as light point, fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, batten, ceiling rose, pendent, any type of MCB's, DB's any type of light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection with S&F small pieces of elctrical copper cable of size upto 10 Sqmm single core and length not exceeding 0.50m, complete all as specified and as directed. Note : Any major items required to be repaired/replaced shall be measured and paid under relevant item of BOQ as supply only.Cost of labour for replacement shall be deemed to included in the unit quoted rate.
Note for item No 1 :- (a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education qualification of tradesman shall be produced to Engr-in-Charge before commencement of work.
(b) All bldg light complaints including service connection, sub main & internal electric for entire OTM and Md accn at AF Stn Jalahalli East & West shall be attended
(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format as directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs.
(d) All sort of petty T&P items such as PVC insulation tape, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor without any extra cost to deptt.
(j) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(k) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the representative of contractor by lodging the time and signature of contractor's rep shall be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more than twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(l) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply only switch piano flush type 5 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply only switch piano flush type 15 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T
Supply only shuttered socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed Make : Anchor, Havells, L&T
Supply only shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed Make : Anchor, Havells, L&T
Supply only switch socket combination out let 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T
Supply only switch socket combination out let 2 in 1, 6 pin 5 and 15 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T
Supply only electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/Havells/L&T
Supply only lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Supply only Ceiling rose 3 phase/ PVC/ Polycarbonate, isolated body flush type 6 Amps ( ISI marked) complete all as specified and directed
Supply only single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996, complete all as specified and directed.Make : Legrand/ L&T/ Indo Asian
Supply only electronic LED driver 36/40 W suitable for 2' x 2' ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed.
Supply only PVC insulated FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 Sqmm of 3 core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza/KEI.
Supply only electronic fan regulator modular type 230 volts, step type socket type, hum free 100/240 watt, complete all as specified and directed. Make : Havells / Anchor/ Crabtree.
Supply only PVC Casing & Capping of 15 mm (width), complete all as specified and directed.
Supply only PVC Casing & Capping of 20 mm (width), complete all as specified and directed.
Supply only PVC Casing & Capping of 25 mm (width), complete all as specified and directed.
Supply only 4' 20W/ 18W LED Retro bar tube rod suitable for existing fitting, complete all as specified and directed. Make : Philips, Bajaj, Havells,Crompton
Supply only 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only metal clad switch socket single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20A for concealing in walls. Make : Legrand/ L&T/ Indo Asian
Supply only bakelite sheet not less than 3 mm thick of suitable size, complete all as specified and as directed.
Supply only electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt , complete all as specified and directed Make : Havells / Anchor/ crabtree
Supply only 7 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton/Havells
Supply only bell push, piono type 5/6 Amp, complete all as specified and directed. Make : Anchor/ Cona/ Havells
Supply only TPN, MCB 20 to 32 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian
Supply only TPN, MCB 40 to 63 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5 Sqmm of 3 core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza/KEI.
Supply only switch socket combination outlet 5 in 1/ 5 pin 5 and 15 Amps flush type with box, complete all as specified and directed.
Supply only PVC gang box 1 way 05 Amp, complete all as specified and directed . Make. Cona/L&T/Anchor
Supply only rigid, non-metalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories, complete all as specified and as directed. Make : Avon plast/ supreme/ Diplast
Supply only insulation tape 25 mm width 10m long (ISI Marked), complete all as specified and directed.
Supply only plug top 3 pin 5 Amps AC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply only switch socket combination outlet 3 in 1/ 3 pin 3 and 5 Amps flush type with box, complete all as specified and directed.
Supply only 4 mfd condensor for exhaust fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 6 Sqmm 3 core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza/KEI.
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm 3 core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza/KEI
Supply only SPN MCB 40 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified and directed. Make : Legrand/ L&T/ Indo Asian/Havells
Supply only 10 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ crompton
Supply only modular switch 1 way 6 Amp.1 module , complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/Indo Asian
Supply only modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/Indo Asian
Supply only modular switch 1 way 16 Amp.1 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/Indo Asian
Supply only modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/Indo Asian
Supply only modular white cover plate with frame,3 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor /Indo Asian
Supply only modular white cover plate with frame,4 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor /Indo Asian
Supply only modular white cover plate with frame,6 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor /Indo Asian
Supply only modular white cover plate with frame,08 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor /Indo Asian
Supply only modular white cover plate with frame,12 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor /Indo Asian
Supply only modular switch 1 way 32 Amp.2 module, complete all as specified and directed. Make : Legrand /Crabtree/ Anchor/Indo Asian
Supply only rigid, non-metalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories, complete all as specified and as directed. Make : Avon plast/ Supreme/ Diplast
S&F in replacement factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian/Havells
Supply only plug top 3 pin 15 Amps AC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza/Indo Asian
S&F in replacement factory made powder coated distribution board SPN 6 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian/Havells
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size all as specified and directed. Note: (a) 2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza/KEI.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size all as specified and directed. Note: (a) 2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza/KEI.
S&F Surface & wall mounted LED fitting including 5 watt LED tube rod complete with all accessories internally, pre-wired, connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down old light fitting. Make : Bajaj /Philips /Havells.
S&F in repairs 36 W (WW/WH) LED recessed 2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted. Make : Philips/ Bajaj /CG/Havells.
Taking down aluminium/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed.
M&L for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 Sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC Casing Capping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 Sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly, complete all as specified and as directed. Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells/KEI Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators shall be measured and paid for separetely under respective item of BOQ.
One light point/fan/bell point controlled by one switch.
All as per item No. 66 here in before but for One 3 pin socket out let 5 Amp on the same board
All as per item No. 66 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 66 above but wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently.
M&L for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 Sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through surface PVC conduit/ existing concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 Sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells/KEI Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch.
All as per item No. 71 here in before but for one 3 pin socket out 5 Amp on the same board
All as per item No. 71 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 71 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 Sqmm drawn through and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size, complete all as specified and directed. Note: (a) 4 runs of 6 Sqmm cable along with two run of 6 Sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. Make:- Havells/ Polycab/ Plaza/KEI
S&F as in repair PVC casing capping medium grade of size 25 mm on wall /roof with help of screws including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Polycab/ Modi/ Presto Plast
S&F as in repair PVC casing capping medium grade of size 32 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Polycab/ Modi/ Presto Plast
Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white aluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . Test Report to be submitted from any govt of India approved lab , The luminaire and driver shall be BIS approved with "R" number mentioned will submitted at time of delivery,. 5 year Company warrenty certificate to be submitted at the time of delivery, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
S& F replacement of conventional type post top fitting with LED Post tops lamp fitting 40 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make: Philips/Bajaj/CG
M&L for wiring for circuit complete submain wiring with 2 X1.5 Sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 Sqmm single core wire PVC insulated, unsheathed FRLS 1100V grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size , complete all as specified and directed. Note :- Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza/KEI
Supply and fix LED spot light focus light fitting 9W,surface mounted,tiltable type AC 230 volts, complete all as specified and directed.
Supply and fix LED upto 7.5 W decorative,surface mounted,doom shaped pendant light fitting extendable type AC 230 volts, complete all as specified and directed.
Supply & fix in repair decorative recessed mounted ultra slim Square/Round profile 18 W LED(WW/WH) lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 18 Watt and including cosidering material & labour for fixing ceiling hight upto 7.5 Mtr, complete all as per site requirement and directed.
S&F in replacement factory made powder coated distribution board SPN 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB conforming to IS: 8623, all as specified. Make : Legrand/ L&T/ Indo Asian/Havells
S&F in replacement factory made powder coated distribution board SPN 12 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian/Havells
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Casing Capping with accessories in wall/roof/ceiling etc incl steel modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 Sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified and directed for following:- Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells/KEI Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators shall be measured and paid for separetely under respective item of BOQ.
One light point/fan/bell point controlled by one switch
All as per item No. 87 here in before but for One 3 pin socket out 5 Amp on the same board
All as per item No. 87 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 87 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L in repairs for point wiring complete with 1.5 Sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor drawn through and incl surface PVC Conduit/ existing concealed conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 Sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified and directed for following:- Make of Cable : Plaza/ Polycab/ Havells/KEI Make of Conduit : Supreme/ Diplast/ Avon Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators shall be measured and paid for separetely under respective item of BOQ..
One light point/fan/bell point controlled by one switch.
All as per item No. 92 here in before but for One 3 pin socket out 5 Amp on the same board
All as per item No. 92 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 92 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indo asian
Supply and Fix switch piano flush type 15 Amps 240 volts single pole one way, complete all as specified and directed.Make : Anchor/Havells/L&T /Indo asian
Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T /Indo asian
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T /Indo asian
Supply and Fix modular switch 1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indo asian
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indo asian
Supply and Fix modular switch 1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indo asian
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indo asian
S&F in replacement on distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian/Indo asian/Havells
Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white aluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . Test Report to be submitted from any govt of India approved lab , The luminaire and driver shall be BIS approved with "R" number mentioned will submitted at time of delivery . 5 year Company warrenty certificate to be submitted at the time of delivery , complete all as specified and directed. Make : Make : Philips/ Bajaj / CG/Havells..
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of alluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/S LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 02Nos. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA - 01No. (d) MCB SPN of 240 V of capacity 40 Amps 10 KA - 01 No. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The Contractor Shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply and fixed in repairs Sheet metal enclosure with distribution board TPN 415 Volts 8 ways Double door with suitable bus bar for provn for MCBs/ Isolators, fixed to wall and making all connections , complete all as specified and directed. Make: Havells/ Indoasian/Legrand
S&F as in repair of LED Strip connector 220 Volt for RGB coloured, complete all as specified and as directed Make : Bajaj / Philips / Wipro.
S&F in repair of LED Strip light 14.4 watt 220 Volt RGB (WW,WH) Pink coloured, complete all as specified and as directed .
S&F as in repair of neon LED Strip connector 220 Volt, complete all as specified and as directed Make : Bajaj / Philips / Wipro.
S&F in repair of neon LED Strip light 220 Volt RGB coloured, complete all as specified and as directed .
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor for over head service connection suspended by insulating hangers not more than one meter apart including 4 mm dia GI suspension wire, complete all as specified and directed.
S&F in repairs Electronic energy meter single Phase 5 to 30Amps range capacity, complete all as specified. Make : BENTEC / L&T/ABB Note :- Old unserviceable meter shall be deposited to E/M store yard.
S&F in repairs 36 W (WW/WH) LED surface mounted 2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted. Make : Philips/ Bajaj /CG/Havells.
S&F in replacement factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB conforming to IS: 8623, all as specified and directed. Make : Indoasian/ Havells/ Legrand.
Supply & fix Square LED down lighter 15 /18 watt fit at surface/Ceiling, complete all as specified and directed and including taking down old fitting.
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of alluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/S LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA - 01 No. (Incomer). (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 06 Nos. (d) MCB SPN of 240 V of capacity 40 Amps 10 KA - 02 Nos. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The Contractor Shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size all as specified and directed. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza/KEI
Supply and Fixing in repairs of 1 feet surface mounted batten type luminaire , lumen output of 500 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operanting voltage range from 140V-270V. The luminaire shall have a white Alluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . Test Report to be submitted from any govt of India approved lab , The luminaire and driver shall be BIS approved with "R" number mentioned will submitted at time of delivery . 5 year Company warrenty certificate to be submitted at the time of delivery and complete all as directed Make : Philips/ Bajaj /CG/Havells.
S&F in repair of new PVC conduit medium grade of size 20 mm on wall /roof with help of screws and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast
S&F in repair of new PVC conduit medium grade of size 25 mm on wall /roof with help of screws and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast
S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1, complete all as specified and directed. Make : Havells/ L&T/ Indoasian/Legrand
S&F in repair of batten holder suitable for LED bulb required at site, complete all as specified and directed.
Supply & fix in repair decorative recessed mounted ultra slim Square/Round profile 9 W LED(WW/WH) lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 18 Watt and including cosidering material & labour for fixing ceiling hight upto 7.5 Mtr, complete all as per site requirement and as directed.
Supply and fixing building security/ LED street light fitting 36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete.Make: Philips/Bajaj/CG
S&F in repairs Electronic energy meter 3 Phase 30 to 60Amps range capacity. Make : BENTEC / L&T/ABB, complete all as specified and directed. Note :- Old unserviceable meter shall be deposited to E/M store yard.
S&F in Replacement rechargeable 12 W LED bulb with frosted PC cover and pull chord. Rechargeable Li-ion battery of 3.7 volts, 2000 mAh capacity environmentel friendly energy effcient .The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Make : Philips / Havells/Bajaj/Halonix
M&L for in repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtr complete all as specified and directed. Note : All safety measures is the responsible of the contractor.
M&L in repair for stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/wooden beading fixed on wall including necessary fixing arrangement up to height 11 mtr complete all as specified and directed. Note : All safety measures is the responsible of the contractor
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 10 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of conduit : Avon Plast/ Supreme/ Diplast Make of Cable : Plaza/Polycab/Havells/KEI Note: 4 runs of 10 Sqmm cable along with one run of 10 Sqmm cable for earth conductor alongwith suitable size PVC conduit shall be measured as one length
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size all as specified and directed. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza/KEI.
Excavation in trenches for laying under ground cable, errection of poles and stays etc in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 meter and depositing where directed at a level not exc 1.50 M above the starting point complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
M & L for Bricks covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed.
M& L for GI tubing light grade of size 50 mm dia fixed on walls / laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed. Note - Excavation and earthwork to be paid separately in respective item of BOQ.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD. (iv) Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 40 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Material and labour for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian/KEI Note - Earthwork and bricks to be paid separately in respective item of BOQ.
Material and labour for 4 core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian /KEI Note - Earthwork and bricks to be paid separately in respective item of BOQ.
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/S LT panel board and remove from site reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 36 KA 4 Pole - 01 No. (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amps, 25 KA - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amps, 25 KA - 01 No. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps, 10 KA - 01 No. (e) MCB TPN of 415 V of capacity 40 Amps 10 KA - 01 No. (f) MCB SPN of 240 V of capacity 40 Amps 10 KA - 01 No. (g) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (h) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (i) Space for spare feeder - 01 No. Note :- (i) The Contractor Shall submit the drawing for approval of GEbefore executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 10 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 10 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size all as specified and directed. Note: (a) 2 runs of 10 Sqmm cable along with one run of 10 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza/KEI.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 Amp by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as specified and directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/S LT panel board and remove from site reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No. (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 315 Amp, 36 KA - 01No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 02Nos. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 01No. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The Contractor Shall submit the drawing for approval before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). Note :- An amount of Rs 57497.50 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
ELAN ENGINEERS (BID ID -3136388)
SRINIDHI DIESELS & ELECTRICALS (BID ID -3140705)
Shiva Shakthi Electrical Enterprises (BID ID -3143076)
M/S SRI BALAJI ENTERPRISES (BID ID -3138124)
ARUNOTHAYA TRADERS (BID ID -3136715)
M/S J S PRAKASAM (BID ID -3143243)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .