| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.3 L+₹17,615 (5.63%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹4.4 L+₹1.3 L (41.4%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
12 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri GanganagarCantt Rajasthan-335001
REPAIR/REPLACEMENT OF COOLING APPLIANCES AT MIL STN SRI GANGANAGAR
2023_MES_586009_1
GE SGNR/TOK-59 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sri Ganganagar(Raj)
E Class c(i) and for un-enlisted, refer NIT para 8.
6 documents required · 6 mandatory
₹300
GE Sri Ganganagar
₹10,000
Yes
23 May 2023
16 Mar 2023
14 Apr 2023
16 Mar 2023
12 Apr 2023
28 Mar 2023
Amount
Disconnecting, dismantling and taking out existing burnt out compressor from the water cooler, supply & fixing of new Hermetic sealed unit compressor along with OLP & starting relay of capacity 1 ton suitable for water cooler of cooling capacity 150 Litres per hour including necessary gas charging complete all as specified and directed by Engineer-in-Charge.
All as per item No. 1 here-in-before but of capacity 1/2 HP suitable for water coolers of cooling capacity 60 Ltrs/Hr complete all as specified and directed by Engineer-in-Charge.
All as per item No.1 here-in-before but of capacity 1/3 HP suitable for water coolers of cooling capacity 40 Ltrs/Hr complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of fan motor, Capacitor starter with blade, single phase, AC, 50 HZ suitable for water cooler of cooling capacity 40/60 litre per hour including fittings on existing MS plate form and making connection all as specified and directed by Engineer-in-Charge.
All as per Item No 4 above but suitable for water Cooler 150 Ltrs Cap. complete all as specified and directed by Engineer-in-Charge.
Rewinding of fan motor with super enameled copper winding wire of adequate size and gauge as per existing winding including insulating material, varnish drying, baking etc for water cooler of capacity 150 litre per hour complete all as specified and directed by Engineer-in-Charge.
All as per Item No 6 above but suitable for 40 Ltrs Cap complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement push cock CP brass 15 mm dia bore suitable for water cooler complete all as specified and directed by Engineer-in-Charge.
Cleaning/ flushing the unit with N2 gas and supplying and recharging the refrigerant gas in water cooler capacity 150 litre per hour including replacement of strainer complete all as specified and directed by Engineer-in-Charge.
All as per item No.9 here-in-before but of cooling capacity 40/60 Ltrs/Hr complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of starting relay suitable for water cooler of capacity 150 litre per hour all as specified and directed by Engineer-in-Charge. complete all as specified and directed by Engineer-in-Charge.
All as per item No. 11 here-in-before but of cooling capacity 40/60 ltrs/Hr complete all as specified and directed by Engineer-in-Charge.
Supply and fixing replacement of copper tubing size 3/5 mm dia for suction & discharge lines in water cooler complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of running capacitor 25 MFD oil filled suitable for water cooler of capacity 150 litre per hour complete all as specified and directed by Engineer-in-Charge.
All as per item No. 14 here-in-before but of capacity 10/20 MFD for water cooler of cooling capacity 40/60 Ltrs/Hr all as specified and directed by Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of starting capacitor 80/100 MFD oil filled suitable for water cooler of capacity 150 litre per hour and making necessary electric connection complete all as specified and directed by Engineer-in-Charge.
All as per item No.16 here-in-before but of capacity 40/60 MFD for water cooler of cooling capacity 40/60 Ltrs/Hr complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of thermostat switch complete with plate and screw suitable for water cooler of cooling capacity 150/60/40 litre per hours and making necessary electric connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of copper wiring kit complete suitable for water cooler of capacity 40/60/150 litre per hour and making necessary electric connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC drain pipe 25/32 mm bore heavy duty including clamp for water cooler complete all as specified and directed by Engineer-in-Charge.
Welding and patch repair of bottom and side panel of water coolers including replacement of bottom MS Sheet of 16 gauge for mounting compressors and blower motors complete all as specified and directed by Engineer-in-Charge.
Disconnecting , dismantling and taking out existing burnt out compressor from the machine, supply & fixing Hermetic sealed unit compressor along with OLP & starting relay as per existing model & make suitable for Refrigerator of capacity 165/170 litre, suitable for operation on 280 volt AC supply including necessary gas charging complete all as specified and directed by Engineer-in-Charge.
All as per item No. 23 here-in-before but for refrigerator of capacity 280/300/310 Ltrs & 320 ltrs of deep freezer complete all as specified and directed by Engineer-in-Charge.
Cleaning / Flushing the gas system with N2 gas and supplying and recharging the refrigerator of capacity 165 to 310 litre& deep freezer with refrigerant gas including replacement of strainer and compressor oil and rectification of leakage in the entire system complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of over load protector suitable for 310 / 286 / 165 litre capacity refrigerator & 300/320 ltr deep freezer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of thermostat switch with knob, plate and screws for automatic defrosting device suitable for 310/286/165 litre capacity refrigerator & deep freezer 320/300 ltrs all as specified and directed by Engineer -in-Charge . complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of door gasket suitable for deepfreezer 300/320 ltr &310/286/165 litre capacity refrigerator complete all as specified and directed by Engineer-in-Charge.
Welding and patch repair of bottom and side panels of refrigerators including replacement of bottom sheet 16 gauge for housing compressors complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of freezer including necessary capillary suitable for 165 litr capacity complete all as specified and directed by Engineer-in-Charge.
Description all as per Srl item No 30 but 286 to 300 litrs complete all as specified and directed by Engineer-in-Charge.
Description all as per Srl item No 30 but 310 to 325 litres complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement condenser coil/Tube set suitable for 310/ 286 Ltr cap & deep freezer 300/320 ltrs complete all as specified and directed by Engineer-in-Charge.
Description all as per Srl item No. 35 here-in-before but for 165/ 175 Ltr cap complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of condenser coil set suitable for Window Type Air Conditioner of cap 1.5 Ton as per existing size complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of condenser coil set suitable for Split Type Air Conditioner of cap 1.5/2.0 Ton as per existing size complete all as specified and directed by Engineer-in-Charge.
Disconnecting , dismantling and taking out existing burnt out compressor from the machine ,supply & fixing of Hermetic sealed unit compressor of cap 1.5/2 Ton , Split AC including necessary gas charging complete all as specified and directed by Engineer-in-Charge.
Disconnecting , dismantling and taking out existing burnt out compressor from the machine ,supply & fixing of Hermetic sealed unit compressor of cap 1.5/2 Ton , Window AC including necessary gas charging complete all as specified and directed by Engineer-in-Charge.
All as per item No. 39 here-in-before but for 1.0 Ton compressor complete all as specified and directed by Engineer-in-Charge.
Rewinding of blower motor of any make single phase for exhaust fan fitted in window type air conditioner of capacity upto1/ 1.5/2/ ton with supper enameled copper winding wire of gauge & weight equal to existing and replacing gun metal bushes including taking out from the air conditioner and refixing in its original position after rewinding complete all as specified and directed by Engineer-in-Charge.
Taking out Split /window type air conditioner upto 1.5/2.0 ton capacity from its position, checking , removing the leakage from refrigeration and charging the refrigerant gas including replacement of strainers and injecting anti moisture dose, fixing in position after testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of starting relay suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of over load protector suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and directed by Engineer - in- Charge.
Supply and fixing in replacement of running capacitor 50/60 MFD (as per existing machine requirement) oil filled, 230 volts for window AC / Split AC including making necessary connections complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of starting capacitor 6 MFD oil filled, 230 volts for blower fan motor including making necessary connections complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of thermostat switch protector suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of copper wiring kit suitable for 1.5/1/2 TR capacity air conditioner and making necessary connections with brass thimbles complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of air filter for window type air conditioner as per sample suitable for cap upto 1.5 ton complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of front grill of window type air conditioners upto 1.5 ton capacity as per model of the air conditioner complete all as specified and directed by Engineer-in-Charge.
Maintenance, servicing and testing of split type air conditioners of capacity 1 to 2 ton of any make by cleaning all dust and stand practice, then apply one coat of cleaning solution and clear with nylon brush over cooling coil of entire AC unit with pressure water in order to remove dust on cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing all electric system, oiling, greasing of blower motor, checking and removing any vibration and leakage device for winter / summer to ensure cutting of compressor / heater in case of failure of blower motor and testing after fixing at site complete all as specified and directed by Engineer-in-Charge.
Maintenance, servicing and testing of window type air conditioners of capacity 1 to 2 ton of any make by cleaning all dust and stand practice, then apply one coat of cleaning solution and clear with nylon brush over cooling coil of entire AC unit with pressure water in order to remove dust on cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing all electric system, oiling, greasing of blower motor, checking and removing any vibration and leakage device for winter / summer to ensure cutting of compressor / heater in case of failure of blower motor and testing after fixing at site complete all as specified and directed by Engineer-in-Charge.
Taking out the unserviceable copper cable by disconnecting all the electrical connections and supply and fix new PVC sheathed copper cable .3 core of size 2.5 SQMM complete all as specified and directed by Engineer-in-Charge.
Supply and fix industrial type sheet metal enclosure with metal clad plug and socket single phase with a two pin and earth plug & socket complete rated 240V 30 Amps capacity controlled by and including 01 No 30 Amps MCB SP 9 KA rupturing capacity complete all as specified and directed by Engineer-in-Charge.
Taking down the unserviceable printed circuit board (PCB) by disconnecting all the electrical connections and supply and fix new printed circuit board (PCB) of 1.5/2TR capacity and reconnecting the same with electrical connections for split type AC and complete all as specified and directed by Engineer-in-Charge.
Taking down the unserviceable printed circuit board (PCB) by disconnecting all the electrical connections and supply and fix new printed circuit board (PCB) of 1.5/2TR capacity and reconnecting the same with electrical connections for window type AC and complete all as specified and directed by Engineer-in-Charge.
Supply and fix the copper pipe for 1.5TR/2TR/3TR(2x1.5TR) capacity, size 1/2 " complete all as specified and directed by Engineer-in-Charge.
Supply and fix the copper pipe for 1.5TR/2TR/3TR(2x1.5TR) capacity, size 3/8" complete all as specified and directed by Engineer-in-Charge.
Supply and fix the copper pipe for 1.5TR/2TR/3TR(2x1.5TR) capacity, size 1/4 " complete all as specified and directed by Engineer-in-Charge.
Taking out the unserviceable metallic fan blades suitable for blower motor for the split type air conditioners and S&F new metallic fan blade of blower motor for split type air conditioners of 1.5 / 2 TR capacity complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of UNSV/burnt point wiring for connection of eqpts load bearable upto 2.5 Sqmm copper conductor with PVC conduit. complete all as specified and directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of UNSV/burnt, Switch socket combination 15 Amp complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in concealed PVC conduict dia 20mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. (Note : PVC cable and PVC conduit shall be ISI marked)
Supply & fixing cooler pad made of Khas-Khas suitable for desert coolers including taking out unserviceable pad complete all as specified and directed by Engineer-in-Charge.
M&L for installation of exisiting (new /old) Split AC 1.5/2.0 Ton with necessary arrangements to fix outer & inner unit on stand (new to be provided by contractor) / grout on the wall with screw and clamps proper connection of copper piping without damage , checking of gas pressure making good surface with PCC and matcing paint complete all as specified and directed by Engineer-in-Charge.
M&L for taking down of split AC with proper disconnection of copper piping from both outer and inner unit , gas restore and servicing the both units with chemical cleaning solution complete all as specified and directed by Engineer-in-Charge.
Supply only 15/16 Amp Top plug for AC connection complete all as specified and directed by Engineer-in-Charge.
Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
SILEWAL CONTRACTOR & SUPPLIER
Ganganagar Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .