Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹23.7 L
EMD Value
₹47,380
Closing Date
16 Nov 2026, 6:00 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
PROVN OF ADVANCE CONTROL RELAY AND CMD CONTROL METER FOR PROTECTION OF 11 KV VCBs AT TOP SUBSTATION UNDER GE NASIRABAD
2026_MES_796090_1
84333/E8
Open Tender
Civil Works
Item Rate
180 days
Nasirabad
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Nasirabad
₹47,380
Yes
28 Oct 2026
28 Oct 2026
18 Nov 2026
28 Oct 2026
16 Nov 2026
11 Nov 2026
28 Oct 2026 - 11 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply,installation,testing and commissioning of Automatic micro Processor based 11 KV Transformer energy monitoring system for upto 400 kv Transformer via V sat satellite Controlled Data communication out put pot with following features all enclosed in MS powder coated box of 1.5 sq mm of suitable size:-
(A) Automatic monitoring of electrical data parameters of LT side of transformer Load /voltage of each phase communication pot
(B) Sending Ringer tone based alert with voice calling with nature of fault to 5 mobile nos and With Non sms based but Words-up alpha numeric based alert of fault to pre-defined 5 mobile numbers with area code with date and time with google map for high loading of 12 nos parameters of transformer Via Vsat satellite controlled data transmitter and non gprs/non internet/non gsm sim based data transmission as mentioned below:-
i) High voltage R Phase LT Side ii) High voltage Y Phase LT Side
iii) High voltage B Phase LT Side iv) High current R Phase LT side
v) High current Y Phase LT Side vi) High current B Phase LT side
vii) MCCB 1 Trip with area viii) MCCB 2 Trip with area
ix) MCCB 3 Trip with area x) MCCB 4 Trip with area
xi) Oil Level low xii) Transformer Body Temperature High
(C) Satellite Vsat controlled out put data pot for transmit ion of Transformer energy data To control room For record generation with Live graphical trends for current peak load on each phase for load balancing/high voltage/high temperature of transformer
(D) Live data monitoring at an interval of 60 seconds via Satellite Vsat controlled data transmitter
(E) Inbuilt Data storage for at least Two year
(F) With LCD Display monitoring of Energy Parameters such as frequency,3 Phase Voltage, 3 Phase current, Power factor, frequency, KVA, KVAH, KW and KWH can be monitored from the central control room
(G) Automatic monitoring of electrical data parameters for upto 630 kv Transformer
(H) All the electrical and alarm data can be printed in EXCEL Format for report generation with date and time for weekly/monthly/yearly) | 2 | Each Job | - | - |
| 2 | SAME AS SNO 1 BUT FOR 315 KV Transformer | 2 | Each Job | - | - |
| 3 | SAME AS SNO 1 BUT FOR 250 KV Transformer | 1 | Each Job | - | - |
| 4 | Supply, installation, testing & commissioning of CT 400/5 To 100/5 (set of 3 ct Per transformer). | 5 | Each Job | - | - |
| 5 | Supply, installation, testing & commissioning of temperature sensor micro chip type RTD Type. | 5 | Each Job | - | - |
| 6 | Supply, installation, testing & commissioning of oil sensor ultra sonic type to monitor oil level of conservator tank from 0% To 100%. | 5 | Each Job | - | - |
| 7 | Supply,installation,testing and commissioning of V-sat satellite Controlled transmitter PCB card with inbuilt micro chip antenna to be installed in Automatic micro Processor based 11 KVA Transformer energy monitoring Panel of 400 kv to 100 kv to transmit Energy monitoring data to control room via Vsat Satellite controlled High power transmitter and to transmit Transformer 12 alert via Ringer tone based alert with voice calling with nature of fault to 5 mobile nos and via Vsat Controlled Non sms based but Words-up based alpha numeric based alert with alert value of fault to pre-defined 5 mobile numbers with area code with date and time with google map of transformer. | 5 | Each Job | - | - |
| 8 | Supply installation, commissioning and testing of VSAT satellite controlled data Master Receiver PCB Card & Non internet/non gprs & non computer based With Vsat micro chip antenna to receive 11 nos 11kv transformer energy real time data such as frequency,3 Phase Voltage,3 phase current, Power factor, frequency, KVA,KVAH,KW and KWH via Exiting 40" LED Screen with operating soft ware and with inbuilt SMPS power supply to be installled in exiting Master Receiver Panel | 1 | Each Job | - | - |
| 9 | Supplying & Fixing on wall / laying in ground 6 X 1.5 Sqmm PVC insulated & PVC Copper armored cable with heavy duty PVC Saddles 60 cm apart complete all As Specified and directed. | 50 | RM | - | - |
| 10 | Supplying & Fixing on wall / laying in ground 4 X 1.5 Sqmm PVC insulated & PVC Copper armored cable with heavy duty PVC Saddles 60 cm apart complete all As Specified and directed. | 50 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_892897.xls
BOQ • 0.24 MB
84333TenderDocuments.pdf
Tender Documents • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .