Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC 6 290 MUTHA GOWDER LINE WELLINGTON BARRACKS THE NILGIRIS 643 231 | THE NILGIRIS | TAMIL NADU | 643231 | ₹33.5 L | L1 | Accepted-AOC Admitted |
| 2 | L2₹36.7 L+₹3.2 L (9.67%)Rejected-Finance NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | ₹36.7 L+₹3.2 L (9.67%) | L2 | Rejected-Finance Being Not the Lowest Tenderer |
| 3 | L3₹39.3 L+₹5.8 L (17.4%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | ₹39.3 L+₹5.8 L (17.4%) | L3 | Rejected-Finance Being Not the Lowest Tenderer |
| 4 | L4₹43.9 L+₹10.5 L (31.3%)Rejected-Finance 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | ₹43.9 L+₹10.5 L (31.3%) | L4 | Rejected-Finance Being Not the Lowest Tenderer |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
6 Feb 2024, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
ADDITIONAL MAINTENANCE FOR LT PANEL BOARD FEEDER PILLAR BOX AUXILIARY SUPPLY EARTHING STREET LIGHT HIGH MAST LIGHT INCLUDING CABLES AND CONTROL PANEL AT VARIOUS LOCATIONS UNDER GE WELLINGTON
2024_MES_637352_1
8883/E8
Open Tender
Civil Works
Item Rate
120 days
Wellington
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹89,000
Yes
6 Mar 2024
13 Jan 2024
12 Feb 2024
14 Jan 2024
6 Feb 2024
23 Jan 2024
Amount
Supply, install, testing and commissioning of factory made and tested CPRI type test certified) (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings cables and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following all as specified and directed :- (Complaint Cell LT Panel No- 2) (a) INCOMING:- (i) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 36 KA, 400 Amps 415 Volts - 1 No Make - C&S reference CSE3N400ATM4P-* or equivalent to technocommercial make. (b) OUTGOING (i) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 25 KA, 200 Amps 415 Volts - 1 Nos Make - C&S reference CSE2M250ATM4P-* or equivalent to technocommercial make. (ii) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 25 KA, 100 Amps 415 Volts - 3 Nos Make - C&S reference CSE1M125ATM4P-* or equivalent to technocommercial make. (iii) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 25 KA, 63 Amps 415 Volts - 3 Nos Make - C&S reference CSE1M125ATM4P-* or equivalent to technocommercial make. (c) 1000 Amps aluminium busbar for phase and 600 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set (d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection- 1 No (e) LED type Indication lamp 415 Volts Set of three - 1 Set (f) danger notice board of size 200 mm x 150 mm x 1.6 mm thick of mild steel sheet printed with vitreous enabled white paint and letter figure and convention skull and bones of signal red colour and fixed / rivetted with panel -02 Nos Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
Supply, install, testing and commissioning of factory made and tested CPRI type test certified) (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings cables and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following all as specified and directed :- (Complaint cell LT Panel No- 1) (a) INCOMING:- (i) Aircircuit breaker Manual fixed with intelligent release micro processor, Auxillary Switch 6 NO+NC, Main Current ransformers, terminal type horizontal 4 pole, 630 Amps rating breaking capacity 50kA -1 No Make - C&S reference AHA06N4P*MP3.1(S) or equivalent to technocommercial make. (b) OUTGOING (i) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 25 KA, 200 Amps 415 Volts - 4 Nos Make - C&S reference CSE2M250ATM4P-* or equivalent to technocommercial make. (ii) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 25 KA, 100 Amps 415 Volts - 1 No Make - C&S reference CSE1M125ATM4P-* or equivalent to technocommercial make. (iii) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 25 KA, 63 Amps 415 Volts - 2 Nos Make - C&S reference CSE1M125ATM4P-* or equivalent to technocommercial make. (c) 1000 Amps aluminium busbar for phase and 600 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set (d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection- 1 No (e) LED type Indication lamp 415 Volts Set of three - 1 Set (f) danger notice board of size 200 mm x 150 mm x 1.6 mm thick of mild steel sheet printed with vitreous enabled white paint and letter figure and convention skull and bones of signal red colour and fixed / rivetted with panel -02 Nos Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
Supply, install, testing and commissioning of factory made LT feeder pillar box, CPRI approved outdoor type 1.1KV made out of MS CRCA sheet 3.15mm thick having 4 Nos Aluminium bus bar of size 100 Amps for phase 600 Amps for neutral fixed on LT, 8 Nos insulators of size 1.0M x 0.5 M x 0.4 M with legs made out of MS angle 50x50x5mm & 0.75mtr in length, locking arrangements front and back opening danger notice board with skull & bone managram and indicating 1100 volt danger board including incoming and outgoing connections and testing on completion all as specified and directed.
Supply and replacement of 50 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete
Supply and replacement of 70 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete
Supply and replacement of 95 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/ loose soil for laying of under ground cable and foundation of poles.etc complete as specified and as directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25 Cm thick etc complete as specified and as directed.
Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point and all as specified and as directed.
Supply and spreading clean dry riddled sand in trenches for cushioning all as specified for cable protection in trenches / ducts complete all as directed. (Note: The punned down thickness shall only be measured)
Supplying and laying reinforced precast concrete cable cover,Class LV, Type I, flat, size 250mm x 150mm x 40mm all as specified and directed.
Cutting PCC/ Road 200 mm thick for laying of cable all as specified and directed
Cement concrete (1:4:8) type D2 with 40 mm graded aggegate for foundation of steel poles/ struts as specified including necessary form work and finishing to all exposed surfaces by using extra cement all as specified and as directed.
GI Pipe light grade 80 mm dia for cable protection in trenches/ at PCC pole for loopin/loop out of cable and cable entry at Bldg/ block end including taking down all as specified and directed
Taking down old earthing material and Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of size 32.x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover, funnel ,watering pipe etc. all as specified and as directed including testing on completion.
Taking down old earthing material and Material and labour for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with GI pipe Light grade 15mm dia as earth strip protection pipe upto 7.5 mtr length , GI pipe medium grade 20mm dia as watering pipe with funnel and wire mesh, PCC chamber with 10mm thick RCC cover all as shown in electrical plate No 5 connected to earth testing point all all as specified or indicated including testing on completion all as specified and as directed
Taking down old unserviceable street light at any height Supply and fixing LED street light fitting 80 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make. Luker product code- LSTE-80 or equivalent techno commercially equivalent.
Taking down old unserviceable street light at any height Supply and fixing LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make. Luker product code- LSTE-100 or equivalent techno commercially equivalent.
Taking down old unsv flood light at any height Supply and fixing LED flood light fitting 150 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make. Luker product code- LFLSL150NSG or equivalent techno commercially equivalent.
Taking down old unsv flood light at any height Supply and fixing LED flood light fitting 200 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make. Luker product code- LFLSL200NSG or equivalent techno commercially equivalent.
GI Pipe Medium Grade 40 mm bore bracket of suitable size bent to shape of not less than 1.2m long with clamp made of GI flat Iron of size 32 x 6mm for street light fittings, duly painted with one coat of red oxide primer and two coats of aluminium based paint, fixed on poles with bolts, nuts and washers including taking down old brackets complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Wiring for circuit/ submain wiring alongwith earth wire with the 2x1.5 sqmm +1x1.5 sq mm earth wire sizes of FRLS is PVC insulated copper conductor, single core cable in steel conduit with suitable clamps and and accessories complete all as specified and directed.
Terminal box made of thermoplastic type out door type of size 260 x 210 x 116 mm for fixing on pole with and including of mild steel clamps with bolt and nuts, provn for cable entry for incoming and outgoing from bottom including provision of fixing MCB SP 20 Amps -1 Nos and 8 way connector with internal copper wiring connection duly fixed with and including cable glants threaded typemade of polymide with lock nut complete all as specified and directed. Make - Sintex or equivalent techno commercially equivalent.
Material and labour for light grade GI pipe 40mm dia for cable protection complete all as specified and directed.
Supply and replace cable route indicator round in shape with cast iron of dia not less than 100 mm duly embossed as LT with 32mm X 6 mm MS Angle welded and foundation with PCC 1:3:6 type C1 using 20 mm graded aggregate complete all as specified and directed
XLPE insulated, armoured heavy duty electric cable with aluminium multi strands conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core complete all as specified and directed.
Taking down old UNSV Timer switch Supply and fix Astronomical time switch for 24 Hrs setting complete all as specified and directed. Make- L&T or equivalent techno commercially equivalent.
Taking down old UNSV Contactor Supply and fix 2 pole power Contactor AC 3 rating 25 Amps AC1 rating 45 Amps MNX 25-2P type Complete all as specified and directed. Make- L&T or equivalent techno commercially equivalent.
PCC 1:2:4 type B-1 using 20mm graded stone aggregate 150mm thick for making good road, finished fair and even all as specified and directed.
Painting the external exposed surfaces of steel tubular swaged / rail poles of 9 metres long with cross arms, brackets and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and pasting radium red stickers with 3 lines of width 5cm each around the pole including Numbering of pole with synthetic enamel white paint on black base, size of letter not more than 5cm and number of letter for each pole not more than fourteen Nos complete all as specified and directed. complete all as specified and directed.
Replacement of old unserviceable aluminium thimble (End terminals/ inter connector) of size up to 50Sqmm from cable end/ panel board in repairs complete all as specified and directed. Make: Dowells/ Jainson
Supply and fix in repairs Time light distribution board (Security light timer) time light contactor rating 32 Amps 3 pole MCB TPN 40 Amps Astronomical Timer street light panel for street light control with enclosure complete all as specified and directed. Make - Havells/ Legrand/ ABB
Steel tubular swaged poles of complete with cast iron base plate, finial taper, plug, bolts, nuts and screws as specified type 410 SP 22, 9 mtr long pole including taking out old poles complete all as specified and directed.
Cement concrete (1:3:6) type C1 with 20 mm graded aggegate for foundation / road crossing including form work and finishing to all exposed surfaces by using extra cement all as specified and as directed.
PVC insulated copper conductor flexible cable 3 core 1.5 Sqmm including taking down old unserviceable copper conductor complete including testing all as specified and directed. Make: Havells basic code -WHMFDSKG31X5 or equivalent to techno commercially equivalent.
PVC insulated copper conductor flexible cable 3 core 2.5 Sqmm including taking down old unserviceable copper conductor complete including testing all as specified and directed. Make: Havells basic code -WHMFDSKG32X5 or equivalent to techno commercially equivalent.
shalom constructions
Rajapriyaconstruction
rvelectricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .