Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 CrAccepted-AOC | ₹6.6 Cr | L1 | Accepted-AOC Lowest bid L1 |
| 2 | L2₹6.7 Cr+₹14.3 L (2.17%)Rejected-Finance | ₹6.7 Cr+₹14.3 L (2.17%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹6.9 Cr+₹32.7 L (4.96%)Rejected-Finance | ₹6.9 Cr+₹32.7 L (4.96%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹7.0 Cr+₹36.5 L (5.53%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹7.0 Cr+₹36.5 L (5.53%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹7.3 Cr+₹66.8 L (10.1%)Rejected-Finance OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | ₹7.3 Cr+₹66.8 L (10.1%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹7.5 Cr
EMD Value
₹7 L
Closing Date
10 Jun 2023, 6:00 pmClosed
CHIEF ENGINEER
HEADQUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
ADDN/ALTN TO ORS MARRIED ACCN AT MATHURA CANTT
2023_MES_590894_1
80878/CEJZ/MTR- /2023-24
Open Tender
Civil Works
Item Rate
540 days
Mathura Cantt
Please refer Tender documents
7 documents required · 7 mandatory
₹3,000
Yes
GE (West) Mathura
₹7 L
Yes
3 Jul 2023
24 Apr 2023
12 Jun 2023
24 Apr 2023
10 Jun 2023
3 Jun 2023
Amount
Taking down Chowkhats or frames not exc. 1.5 sq m each with shutters (without taking off shutters from the frames), complete, all as directed by Engr-In-Charge.
Taking down Chowkhats or frames exc 1.5 sqm but n exc 4 sqm each with shutters (without taking off shutters from the frames), complete, all as directed by Engr-In-Charge.
S&F pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc, complete all as specified and directed by Engr-In-Charge.
S&F pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc, complete all as specified and directed by Engr-In-Charge.
S&F 30 mm thick factory made flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both sides include provision of suitable blocks for taking mortice locks, latche, or other fittings,complete all as specified and directed by Engr-In-Charge..
S&F 2nd class hard wood 35mm thick factory made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as directed by Engr-In-Charge..
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or stainless steel wire staples, complete all as specified and directed by Engr-In-Charge.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing,complete all as specified and directed by Engr-In-Charge..
S&F 30mm thick factory made solid PVC moulded door shutter with particle board core with 5mm thick PVC moulded sheet on the front face and 5 mm thick PVC plain colour sheet on back face, complete, all as specified and directed by Engr-In-Charge..
S&F 150mm long Aluminium anodised, barrel tower bolts of extruded section, complete, all as specified and directed by Engr-In-Charge.
S & F 150 mm size Aluminium handles, cast type & anodised, complete, all as specified and directed by Engr-In-Charge.
S&F for stainless steel butt hinges medium weight 100 mm long, complete, all as specified and directed by Engr-In-Charge.
S&F powder coated Anodised aluminium frame (minimum thickness of powder coating 50 micron) for windows, ventilators (sliding , fixed or casement) with one or more rebates including joining cleat for fixing etc, complete, all as specified and directed by Engr-In-Charge.
S & F powder coated anodised Aluminium alloy sections sliding windows with frames Series-B (18 mm) and , 3 track sliding shutters duly fitted with neoprene beading, glazing clips, two shutters tinted glass panes 4.80 mm nominal thickness one shutter with stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed. Note : Quoted rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle with or without opeing for AC/cooler, complete, all as specified and directed by Engr-In-Charge.
S&F Anodised powder coated aluminium window and ventilator shutters, fixed type with sash bar and louvered, aluminium section weighing 0.55 Kg/M including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified.
S&F Anodised powder coated aluminium window and ventilator shutters, side hung type with sash bar and louvered, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws incl pegstay 150mmlong, hinges100mm long, suitable handle etc., complete, all as specified and directed by Engr-In-Charge.
M&L for PCC 1:3:6 type C0 using 12.50 mm graded crushed stone aggregate as in bed block or filling of chowkats incl necessary form work wherever required, complete, all as specified and directed by Engr-In-Charge.
S & F mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete, all as specified and directed by Engr-In-Charge.
S&F 300 mm Aluminium alloy, anodised, sliding door bolts, with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy, complete, all as specified and directed by Engr-In-Charge.
S&F 100mm long hasp and staple, aluminium anodised incl bolt to hinges plate fixed with screws, complete, all as specified and directed by Engr-In-Charge.
S&F 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in door with screws, complete, all as specified and directed by Engr-In-Charge.
S&F Tubular towel rail 20mm dia 600mm long Aluminium Anodised as per sample approved by the GE and as directed by Engr-In-Charge.
S&F curtain rod stainless steel chrome finished, 20 mm dia as per sample approved by the GE and as directed by Engr-In-Charge.
S & F stainless steel curtain chrome finished brackets/ stops/rollers for 20 mm dia stainless steel curtain rod as per sample approved by the GE.
S & F stainless steel chrome finished curtain knobs/ fancy end caps etc. for 20 mm dia stainless steel curtain rod as per sample approved by the GE .
S&F mild steel 300mm ordinary rat rail rod pattern springs including roller and roller plate, complete, all as specified and directed by Engr-In-Charge.
Demolition of concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Roughening the surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and directed
M&L for 25 mm thick PCC type B-0 (1:2:4) using 12.5 mm aggregate as in floor, finished even and rough to received top layer or tiling, complete, all as specified and directed by Engr-In-Charge.
M&Lfor Non skid Ceramic coloured, joint free tiles 7 to 8 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm and not exceeding 0.38 sqm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15mm thick screed bed in CM 1:4, complete, all as specified and directed by Engr-In-Charge.
All as per description of serial item no 29 above but as in skirting over and including 10mm thick backing coat in CM 1:3, complete, all as specified and directed by Engr-In-Charge.
Dismantling floor hearth and wall tiling including cement mortar bedding (but not backing) and rubbish off the premishes, all as directed by Engr-In-Charge. .
M & L for non skid ceramic tiles (colored), 7 to 8 mm thick as in floor area of each tile exceeding 0.06 Sqm but not exceeding 0 .11 Sqm , set and jointed in neat cement slurry and pointed in white or colored cement to match over and including screed bed or beding layers of 15mm thick in CM 1:4 as in floors, complete, all as specified and directed by Engr-In-Charge.
M&L for Coloured Glazed ceramic tiles in vertical surface 450x300x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including10mm thick BACKING plaster in cement mortar (1:3), complete, all as specified and directed by Engr-In-Charge.
M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) for Shelves (veneering to wall) over and including 12mm thick plaster in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete, all as specified and directed by Engr-In-Charge.
M&L for Machine cut kota stone slab flooring 18-20mm thick over and incl 20 mm thick screed bed in CM 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete, all as specified and directed by Engr-In-Charge.
M&L for Kota stone slab 18-20mm thick ( One piece) in riser of steps, skirting, dado and pillar laid over and incl 15mm thick backing coat in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete, all as specified and directed by Engr-In-Charge.
Rounding to edges of stone slabs one edge , such as in steps, cooking platform and other similar situations, complete, all as directed by Engr-In-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L for Brickwork with fly ash old size bricks straight or curved on plan exc 6 m mean radius built in CM 1:6, complete, all as specified and directed by Engr-In-Charge.
M&L for Brickwork with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete, all as specified and directed by Engr-In-Charge.
M&L for rendering dubbing coat over damaged irregular surface of walls/chajjas/ roof projections/ ceiling/ facia etc average 15mm thick in cm 1:4 over cement slurry @ 3 Kg/sqm, making the surface even followed by 5mm thick rendering in CM 1:3 finished even & smooth including making of drip course including necessary form work wherever required and applying two coats of Apex/Cement Base Paint/White wash as reqd to match with existing surface complete incl taking down/roughening surface of old surfaces by picking sweeping clean and washing with water, complete, all as specified and directed by Engr-In-Charge. Note : Quoted rate shall include rate for form work wherever required.
Taking down cement plaster on brick or stone walls,ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in two coat, first coat with 10mm thick in cement plasterr 1:6, finished fair and even and second coat with 5 mm thick in cement plaster 1:4 mixed with water proofing compound as per manufacturer's instruction, finished even and smooth without using extra cement, on wall surfaces, complete, all as specified and directed by Engr-In-Charge. (WPC Shall be measured & paid seperately)
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces of wall surfaces, in cement mortar 1:6, finished even and smooth without using extra cement, complete, all as specified and directed by Engr-In-Charge.
M&L for rendering 5mm thick on concrete surfaces in ceiling in cement mortar 1:3, finished even and smooth without using extra cement, complete, all as specified and directed by Engr-In-Charge.
M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified & directed. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for Cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping, benching, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, incl necessary form work wherever required,complete, all as specified and directed by Engr-In-Charge.
M&L for PCC 75mm thick, 1:4:8 type D2 using 40mm graded crushed stone aggregate as in sub base, complete, all as specified and directed by Engr-In-Charge.
M&L for pre polished rubber moulded Chequered cement concrete tiles (any colour) 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over and including 20mm screed bedding in cement mortar (1:4), complete, all as specified and directed by Engr-In-Charge.
Supply and laying 60mm thick factory made chamfered edge cement concrete interlocking paver block of M-35 grade confirming to IS 15658-2006 with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;
M&L for treatment of sunken floor slab comprising of the following specifications with and including demolition of sunken floors complete all as specified and directed by Engineer-In-Charge:- (i) Cleaning the sunken/lowered portion of RCC slab surface (incl vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely and providing 40 mm thick avg PCC 1:2:4 type B-O using 12.5mm graded crushed stone aggregate as in padding concrete to achieve proper slope incl cutting holes in bricks or in RCC wall for spout. (ii) Rendering of uneven surfaces with 6mm thick in CM 1:4 mixed with and incl integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc/Thermax as approved by GE @ 0.2% by wt of cement or as per manufacturer's instructions incl filling it with water to check dampness and seepage and where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out. (iii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sikaguard 694 F(I) or equivalent make in Fosroc/Thermax as approved by GE (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
(v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or equivalent make in Fosroc/Thremax as approved by GE over base coat as per manufacturer's instruction to bottom and vertical sides upto finished floor level +100 mm height. The thickness of two layers shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vetical and bottom surface of the sunken portion. (vi) Plastering of bottom surface and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with and incl integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc/Thermax as approved by GE @ 0.2% by wt of cement consumed or as per manufacturer's specification incl rounding of corners and injuctions sloping towards spout. (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6, type C1 all round after painting with anticorrosive paint. (viii) The sunken floor shall be filled with lean concrete 1:7:12, type F2 using 40mm graded stone aggregate.. Note :- Test the water proofed area (ponding test) by filling water for atleast 72 hours and tested for leakage/seepage and to the entire satisfaction to GE. Test record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing and all M&L is included in the rates quoted above.
Supply only integral water proofing compound conforming to IS: 2645.
Dismantling brick/concrete tiles, any size etc incl existing roof treatment of any thickness .
Demolition of mud or bricks in roofs, any thicknees and in any position and leaping over roof terrace, removing the demolished material to a distance exc 250 m but not exc 500 m and depositing where directed at a lavel not exc 1.5 m above starting point ,complete, all as specified and as directed by Engr-In-Charge.
M&L for providing, cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in coping, coving, roof padding, padding in sunken slab, complete, all as specified and directed by Engr-In-Charge.
M&L for screeding 10mm thick in CM 1:4 on RCC roof surfaces, mixed with water proofing compound as per manufacturer's instruction, finished even and fair to receive APP membrne roof treatment, complete, all as specified and directed by Engr-In-Charge. (WPC Shall be measured & paid seperately)
M&L for water proofing treatment with APP modified bituminous membrane 3mm thick consisting of the following for RCC roof surfaces :- (a) Cleaning screed bed/plastered surfaces of RCC roof and applying a coat of cold applied bituminous primer confirming to IS:3384 @ 0.40 Kg/Sqm of approved make on dry surface, complete all as specified and directed. (b) M&L for APP modified polymeric waterproofing membrane not less than 3mm thick, weighing not less than 3.5 Kg/Sqm, reinforced with with polyster non woven fabric (weighing not less than 150 Gm/Sqm) and upper side of membrane thermally insulated with white mineral gravel finish, uniformly embedded during manufacturing process, shall only be used. It shall be laid by torch application with side overlap of 75mm and end lap of 100mm . All overlap and joints shall also be sealed by torch application. For parapets, membrane shall be taken to a height of min 60cm and then inserted inside the parapet in a groove. The same shall be finished by a membrane flashing, complete all as per manufacture instructions and as directed by Engr-In-Charge.
M &L for Cement concrete tiles 25cm x 25cm x 20mm thick, machine pressed, set, jointed and pointed in neat cement slurry in floors/roof over and including 20 mm thick screed bedding layer in CM 1:4, complete, all as specified and directed by Engr-In-Charge.
Taking up or down steel tubing and connections,15 mm bore complete all as specified and directed.
Taking up or down steel tubing and connections , 20 mm bore complete all as specified and directed.
M&L for cutting chasing in bricks/walls or concrete surfaces for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth, complete, all as specified and as directed by Engineer-in-charge
M&L for 15 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
M&L for 20 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Taking down eaves gutters and rain water pipes, soil, waste and vent pipe ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc., including cleaning for refixing ( measured overall as fixed along the centre line over fittings and accessories) complete, all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes of pressure rating 6kg/per sqcm, single socketed, in any length with rubber ring joints, fixed to walls, complete, all as specified and as directed by Engineer-in-Charge.
S&F 75 mm bore PVC (SWR) pipes of pressure rating 6kg/per sqcm single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete, all as specified and as directed by Engineer-in-Charge.
S&F 75 mm bore PVC (SWR) pipes of pressure rating 6kg/per sqcm single socketed, in any length with rubber ring joints, fixed to walls, complete, all as specified and directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) bends, any radius with oval access door, complete, all as specified and directed by Engineer-in-Charge
S&F 75 mm bore PVC (SWR) bends, any radius with oval access door, complete, all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) junction , single T equal or unequal, complete, all as specified and directed by Engineer-in-Charge
S&F 75 mm bore PVC (SWR) junction , single T equal or unequal complete, all as specified and directed by Engineer-in-Charge
M&L 75 mm bore PVC (SWR) vent cowl complete, all as specified and directed by Engineer-in-Charge
S&F 50 mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors or fixed to wall for spout etc complete including taking down old pipe complete, all as specified and directed by Engineer-in-Charge.
M&L for Bands, straps, supports or stays, for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed .
S&F in repairs bib taps cast copper alloy with screwed down for iron pipe or brass ferrule and fixed, fancy type, chromium plated for 15 mm bore pipe.
S&F in repairs stop cock angle type cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipe (chromium plated) for 15mm bore pipe.
S&F in repair fancy type stop cock cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipe chromium plated (concealed type) for 15mm bore pipe.
S&F in repair vitreous china squatting pan “orrisa” pattern of size 580mmx 440mm “white” with integral foot rest (excluding flushing cistern and flush pipe) including provision of lime concrete bedding, connection to trap and to flushing pipe, anti-syphonage pipe etc complete making good to floor complete all as specified and as directed by Engineer-in-charge.
S & F in repairs PVC flushing cistern of 10 ltr capacity valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including flush pipe of 32mm bore MS chromium plated and connection to pipes etc complete all as specified and directed by Engineer-in-charge.
S&F in repair Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed by Engineer-in-charge.
S&F in repairs vitreous china wash hand basin white flat back size 550 x 400 mm excluding taps waste chain and plug but including bracket , complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated shower rose of 125mm size complete
S&F in repairs Shower arm 15mm size 195mm long with bend of 45 degree with flange of CP any colour (minimum weight 40 gms)
S& F in repair PVC connection best quality with PTMT nuts 450mm long.
S&F Chromium plated central hole basin mixer for mixing hot & cold water for WHB including taking down existing old pillar tap, complete all as specified and directed
Dismantling old water tanks and removing to store exc 500 & nexc 1000ltrs.
S&F 750 Litre capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
M&L for PCC (1:3:6) type C-2 with using 40mm graded crushed stone aggregates including necessary form work as in platform for PVC tank, complete all as specified and directed by Engineer-in-Charge.
S & F for 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed of (minimum weight 210gm) complete all as specified and as directed by Engineer-in-Charge.
S&F 32mm bore waste fittings, brass, chromium plated for basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
S&F 40 mm bore waste fittings, brass, chromium plated for sinks, with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
S&F 20mm GI nipple suitable for HDPE water tank.
S & F 32mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 and fittings, fixed to WHB, sink etc complete.
M&L for preparation of new wooden surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of old or previously treated steel surfaces of any description, over 10cm in width or girth and applying one coat of synthetic enamel paint complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surface of walls and applying two coat of oil bound distemper of approved shade over a coat of alkali resistance primer with roller application as per manufacturer's instruction to get even and smooth surface over and including 1 mm thick finished and smooth coat of wall care putty, complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of old treated surfaces of walls by removal of existing treatment and applying two coat of oil bound distemper of approved shade over a coat of alkali resistance primer with roller application as per manufacturer's instruction to get even and smooth surface over and including 1 mm thick finished and smooth coat of wall care putty, complete, all as specified and directed by Engineer-in-Charge.
M&L for applying three coat of white wash on ceiling including preparation of new plaster surface, complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of old white washed ceiling surfaces and applying two coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surface of wall and applying three coats of white washing complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in in surface channel and drains, complete, all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel of manholes inner girth n exc 30cm in cement concrete using extra cement including forms mould mitred stopped ends etc all as specified & directed.
Supply & providing 25mm thick precast cement concrete type B0, 1:2:4 using 12.5mm graded crushed stone aggregate louvres and jallies, set in CM (1:4) (measured solid) including all mouldings and frame,complete, all as specified and directed by Engineer-in-Charge.
Supply & providing precast cement concrete 1:2:4, type B1(using 20mm graded stone aggregate) as in manhole cover slab with plain fair faces and set in cement mortar 1:4, complete, all as specified and directed by Engineer-in-Charge.
S&F 18 MM thick PVC Celuka board of plain white color both side fixed with screws, solvent cement/ adhesive to make kitchen cabinet/cupboard sides, top and bottom and shelves inside the cabinets, cupboard shutters/frames (Density- 575 to 600 Kg/ CBM),complete, all as directed by Engineer-in-Charge.
S&F 18 MM thick PVC Celuka board of single side prelam/rigidlam color fixed with screws, solvent cement/adhesive to make kitchen cabinet sides top and bottom and shelves inside the cabinet, cupboard shutters/frames, (Density- 575 to 600 Kg/ CBM), complete, all as directed by Engineer-in-Charge.
S&F Auto closing hinges 35 MM of 0 crank (KH-001) or 8 crank (KH-002) openable at 110 digree for kitchen cabinet shutters, as per sample approved by the GE.
S&F Continous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flap 40mm, complete all as specified and directed.
S&F stainless steel handles 100 mm size for kitchen cabinet shutters/ cupboard complete all as specified and directed.
S&F magnetic catcher of size 20mmx50mm suitable for kitchen cabinet shutters/ cupboard, complete all as specified and directed.
S&F Ball bearing runners 45 MM Telescopic chromium plated, heavy duty (KTS-20) full extension load capacity 50 kgs,complete all as specified and directed.
S&F stainless steel Kitchen plate rack of overall minimum size 900mm x 900, with partitions for small/large plates etc made out of stainless steel sheet 0.8 mm thick , fixed with rawl plug and CP steel screws all as directed. Note : Weight of rack shall not be less than 7.00 Kg/Each.
M&L for cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), dia of outlet 100mm, complete all as specified and directed.
M&L for cast iron nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), dia of outlet 100mm, complete all as specified and directed.
S&F in repair soap dish,chromium pated,fixed to plugs with chromium plated brass screws complete all as specified and directed.
Taking down shutter of any description exc 1 sqm but n. exc 2 sqm each complete all as specified.
M&L for prepairing new plastered surfaces and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and incl priming coat of exterior primer applied @ 0.90 litre/10 Sqm with roller application as per manufacturer's instruction to get even and smooth surface, complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of old existing treatment and preparation of old surfaces and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and incl priming coat of exterior primer applied @ 0.90 litre/10 Sqm with roller application as per manufacturer's instruction to get even and smooth surface, complete all as specified and directed by Engineer-in-charge.
M&L for two component elastomeric acrylic polymer modified cementitious waterproofing coating of approved manufacturer , having 80 % elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, Sprinkle sand at 10-15 gram per sqft for better grip with plaster, Complete as per manufacturers instructions and as directed by Engr-In-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilitate demolition complete all as specified and directed
S&F MS Joist, channel, angle, or tee sections , fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe 410 -W Gde-E- 250) quality-A complete all as specified and as directed by Engineer-in-charge.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved by GE and having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
M&L for 50 mm thick sand stone slab as in chajja/cover slab set and jointed over supports in CM (1:4) complete all as specified & directed.
M&L for Mild steel TMT bars 6 to 8mm dia cut to length bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified.
M&L for RCC (nominal mix) 1:2:4 uing B-1 (20 mm graded stone aggregate) as in chajja complete all as specified and directed.
Formwork to soffits of chajjas and such as roof slabs, landings and similar work: not exceeding 200 mm thick (Horizontal or sloping)
Formwork to edges of concrete flats, floor slabs, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 5cm but n exc. 10cm wide, complete, all as directed.
Taking down surface/ conceled aluminium point wiring (light,bell,fan,socket or power) complete, including fixtures and fittings such as switches,ceiling roses,lamp holders,pendants,sockets, regulators,tubelight fittings etc and making good disturbed surfaces walls, floors etc complete.
M&L for point wiring with 1100 volts grade PVC insulated FRLS-H multistranded copper conductor cable 2.5 sqmm (Phase-Red& Neutral-Black) and earth continuity conductor 2.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20mm bore, ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches as required for the following:-
One light point controlled by one, one way switch
One fan/exhaust point controlled by one, one way switch
One light point controlled by two way switches
One bell point controlled by one bell push.
One 3 pin socket outlet 5 Amps point controlled by one switch on the same board with other switches.
One 3 pin socket outlet 5 Amps point controlled by one switch on independent board.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase-Red & Neutral-Black) and earth continuity conductor 2.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20mm bore ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches as required for one light point controlled by one switch on 16 Amp independent board, complete all as specified and as directed by Engineer-in-charge. .
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4 sqmm (Phase-Red & Neutral-Black) and earth continuity conductor 4 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20mm bore ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, socket as required for on 16 Amps socket outlet point controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-charge.
S&F Switch, flush type single pole, one way 6 Amp complete all as specified and directed.
S & F flush type, single pole, two way 6 Amp switch complete all as specified and directed..
S & F Bell push, flush type, 6 Amp 240 Volts complete all as specified and directed..
S & F Bell ding dong type, AC, 240 volts, single pole complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed.
S&F Switch, flush type single pole, one way 16 Amp complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and directed.
S & F hum free electronic five stepped type fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete all as specified and directed.
S & F angle holder insulated polycarbonate body complete all as specified and directed.
S&F ceiling rose 63 x30mm three terminal,polycorbonate body complete all as specified and directed..
S & F LED (1.2 M) smartbrite extra batten made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumen/20 watt at a minimum system efficacy of 2000 lumen per 20 watt and total power consumption not more than 20 watt including driver of capacity 10 KA. it has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10% AND PF>0.95 complete all as specified and directed.
S&F LED bulb base B22 of capacity 10 watts not less than 700 lumens output at 6500K colour temp, complete all as specified and directed.
S & F of LED (0.6 M)/ 2 ft smartbrite extra batten made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 1150 lumen/10 watt at a minimum system efficacy of 1150 lumen per 10 watt and total power consumption not more than 10 watt including driver of 5 KA capacity. it has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10% AND PF>0.95 complete all as specified and directed.
S&F Security Light of 35 watts of new generation energy saving & environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and impact resistance of IK07 with 10KV Built -in-Surge Protection Devision,should have a colour temperature of 6500 K, CRI>80, THD<10% AND PF>0.95 including suitable pipe, clamps, nut and bolts for mounting the light all as specified and directed
S&F LED bulk Head 10W HEXA environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs with all connected accessories all as directed and specified.
M&L for concealed submain wiring with PVC insulated FRLS-H multistranded copper conductor cable of size 2x6.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 25mm bore, ISI marked, ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS-H multistranded copper conductor cable as continuous earth wire including cutting chasing and making existing colour on the wall complete all as specified and directed. (Note :- Two runs of 6 Sqmm copper wire and one run of 6 sqmm copper earth wire alongwith PVC conduit shall be meausred as one unit)
Taking down carefully sub main wiring with PVC casing capping/PVC surface conduit and making good distrubed surface to match the existing complete all as specified and directed.
Taking down MCB distribution board with incoming and outgoing controls any make and capacity after disconnecting complete.complete all as specified and directed.
Taking down old unserviceable indoor DB panel of any capacity complete all as specified and directed.
S&F factory made, vertical distribution board TPN 4 way, double door type, protection class IP-42 suitable for mounting MCCB as incomer and SP MCB as outgoing and DBs conforming to IS-13032, IS-8623, BS-5484, complete, all approved & directed.
S&F factory made, sheet steel distribution boards double door, protection class IP-42 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amps rating copper bus bar, SP& N 8 Ways, complete, all approved & directed.
S & F MCBs of 'C' series SPN 40 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete Legrand Cat Part No 408628-36 or equivalent Cat Part No. from Make specified in Appendix 'B', complete all as approved and directed.
S & F MCBs of 'C' series single pole 6 to 32 amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete Legrand Cat Part No 408587-95 or equivalent Cat Part No. from Make specified in Appendix 'B' all as specified and directed. all as specified and directed.
M&L for making of hole in brick wall including removal of dismantled materials, making good disturbed surface, platering, making holes fixigng bolts suitable for fixing 10" exhaust fan frame, complete, all as directed.
M&L for making of hole in brick wall including removal of dismantled materials, making good disturbed surface, platering, making holes fixing bolts suitable for fixing 12" exhaust fan frame, complete, all as directed.
S & F 20 Amp, single pole and neutral socket outlet with 2 pole and earthy, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for socket oulet with and including one number single pole 'C' series MCB 20 Amp as required complete all as specified and directed.
Supply, installation and commissioning (maximum energy efficient type) Water heater storage type, five star electric complete of capacity 25 litres, heating element capacity 2 KW, vertical, plastic body including grouting of studs in wall in cement mortar (1:3) nuts, washers and provision of two numbers heavy duty flexible SS connection pipe of hot and cold of 600 mm long with brass nuts and two number brass chromium plated angular valve suitable for 15 mm bore pipe for water supply connection complete all as specified and directed.
M&L for Cutting existing tubing and taking up for tapping/termination of pipe line, screwing existng steel tubing of size 15mm dia complete all as specified and directed.
BLANK
S&F angle cock 15mm dia cast copper alloy fancy type with crutch of butterfly handle screwed down for iron pipe complete all as directed.
Taking down of ceiling fan 1200/1400 mm of any make & capacity from any height and removing its blades and refixing the same including material and labour for rewinding, with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including taking out old copper wire and spray painting of ceiling fans (motor and blades etc) of existing colour or approved by Engr-in-Charge with super enamelled paint one coat all as specified and directed by Engr-in-Charge.
Taking down of ceiling fan 1200/1400 mm of any make & capacity from any height overhauling of fan motor of any size and removing unserviceable grease, bearings, bushes, split pin, nuts and bolts and cleaning with petrol/kerosene applying new grease and reassembling complete including replacement of wornout spares with new like split pin, nut & bolts and spray painting of ceiling fans (motor and blades etc) as per existing colour or approved by Engr-in-Charge with super enamelled paint one coat all as specified and directed by Engr-in-Charge.
S&F exhaust fans 250 mm sweep,ventilator, three blade double ball bearing, metallic body,1400 RPM, minimum air delivery discharge 1710 CMH suitable for SP, 230/250V, 50 Hz AC supply with protective bird guard with louver shutters including grouting of frame in wall and connecting with and including 3 run 1.5 Sq mm single core, PVC insulated but unsheathered FRLSH multistranded copper conductors cable from ceiling rose to exhaust fan all as specified and directed.
S&F exhaust fans 300 mm sweep metallic body, heavy duty, four blade, double ball bearing, 1400 RPM, minimum air delivery discharge 1710 CMH suitable for SP, 230/250V, 50 Hz AC supply with protective bird guard with louver shutters including grouting of frame in wall and connecting with and including 3 run 1.5 Sq mm single core, PVC insulated but unsheathered FRLSH multistranded copper conductors cable from ceiling rose to exhaust fan complete all as specified and directed.
M & L in replacement of Earthing complete with galvanized steel earth plate electrode 60cmx60cmx 6.3mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanised earth strip 25x4 by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elecrical plate No 3 of MES SSR Part I connected to main DB or main control board all as specified and testing on completion including provision of earth wire portected by galvanised iron 40 mm bore light grade pipe with all fittings from the earth electrode fixed along pole with and including 25 x 6 mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth electrode to bottom of the earth pit and earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides including all excavation and earth work in any type of soil and removal of soil upto 50 metre, PCC pit with pre-cast RCC cover with handle with 10mm dia, charcoal/salt, funnel, CI frame etc complete all as specified and directed
Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit, ISI marked 20 mm dia (external) with wall thickness not less than 1.8 mm with conduit accessories including cutting chasing and one run of 4.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable as earth conductor complete as specified.& directed by Engr-in-Charge. Note : Two runs of 4 Sqmm cable, one run of 4.00 Sqmm earth conductor shall be measured and paid as one RM along with one run of PVC conduit for AC poin.
S&F ceiling fans (5 star rated by Bureau of energy with service value of not less than 6.12) BLDC, (40 W+-10%), aerodynamically design blades made of compounded ABS to give air friction for silent operation, with air delivery 240 cum/min, rated speed 280 Rev/min, with or without remote complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep, suitable for single phase supply with noise level 56 db, low voltage starting input voltage 140 V (Max) with power factor 0.95 all as specified & directed.
Taking down of smart prepaid meter with accessories & refixing the same after completion of surface work with nut, bolt etc as directed by Engr-in-Charge.
S& F MCCB 63 Amps 4 pole 16 KA 415 Volts, 70-100%, 50 Hz as directed by Engineer-in-charge.
Supply, laying, jointing & testing 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings as socket, elbow, reducer, end cap, male & female threaded elbow, male & female threaded socket, tee, wall clamp, & other accessories fixed complete to walls, ceilings or in floors etc, of the size 25 mm outer dia including taking down old unserviceable GI pipe, complete. all as specified and directed
Excavation in trenches not exe. 1.5 Mtr width and not exc 1.5 Mtr depth and getting out in hard / dense soil, for laying cables, pipes etc., complete all as directed, complete, all as specified and directed by Engr-In-Charge.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick, complete, all as specified and directed by Engr-In-Charge.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete, all as specified and directed by Engr-In-Charge.
S&F PP-R Ball valves (brass insert) 25 mm as per requirement of the site complete including taking down old gate valve all as specified and directed.
BLANK
Supply and laying approved dry river sand for cable cushioning in trenches to full excavated width at bottom and top of cable, gently punned down, complete all as specified and directed by Engineer-in-charge. Note: Punned thickness only shall be measured and paid.
Supply only bricks slightly over burnt (kiln burnt) , old size bricks , best quality locally available , laid flat dry laid in trenches for cable protection all as specified and directed.
Supply and laying in replacement of LT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete, all as specified and directed by Engr-In-Charge. Note: Sand & bricks (suuply only) for cable protection shall be measured and paid separately under respective items.
Supply and laying in replacement of galvanised iron pipe 50mm bore light grade incl all fittngs for protection of UG cable, complete, all as specified and directed by Engr-In-Charge.
M&L for drilling hole under road for laying of U/G cable through pipe of suitable size complete, all as specified and directed by Engr-In-Charge.
Lachman Das Govind Ram
TEAM ACC INFRABUILD PRIVATE LIMITED
M/S Chhavi Constructions Co
M/s Himgiri construction
PARAS BROTHERS
SNG BUILDERS AND ENGINEERS
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .