Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹40.9 L+₹1.0 L (2.54%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹42.4 L+₹2.5 L (6.18%)Rejected-Finance 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹42.5 L+₹2.6 L (6.52%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹46.7 L+₹6.8 L (17.1%)Rejected-Finance VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
27 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR M K YADAV, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
PROVISION OF STAND BY POWER SUPPLY FOR SEWAGE AND WATER SUPPLY INSTALLATION AT AIR FORCE STATION UNDER GE (AF) KALAIKUNDA
2023_MES_629482_2
C/8911/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹86,000
Yes
29 Feb 2024
30 Dec 2023
29 Jan 2024
30 Dec 2023
27 Jan 2024
13 Jan 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any kind of soil ,complete all as specified and directed Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/-per hour will be charged to contractor. In this GE decision will be final.
Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L providing sand cushioning with a layer of clean, dry, fine sand for protection of electric cable laid in trenches/ducts, punned down to desired thickness complete all as specified and directed. (Note: For payment purposes only punned down thickness of sand shall be measured )
M & L for laying old size sub class ‘B’ brick for PVC/ XLPE under ground cable protection in trench, layed in the manner that width of brick to be peperndicular to the axis of cable, over LT under ground cable complete all as specified and directed.
Materials and Labour for plain cement concrete (1:4:8) Type D-2 using 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work complete all as specified and directed.
Materials and Labour for rendering 10 mm thick, cement plaster, in cement mortar (1:4) on fair faces of brick work or concrete surface in walls,complete all as specified and directed.
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated any approved profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.(Tata bluescope/Sexena Marine Tech/JSW or equivalent make)
S&F Roof trusses (framed) trussed, purline crane gantries ,rails and fastenings and heavy brackeet framing (Beam,tee,angle, channel or flat sections) including distance pieces ,cleats etc Fe-410-W (Gde-E-250)quality-A complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core with reduced neutral conductors (4 core), nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core with reduced neutral conductors (4 core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including all fitting clamps, nut, bolt and washers complete all as specified and directed.
Horizontal boring of holes by mechanical means, at under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 40 to 50 mm bore, galvanised steel tubing,and making good distrubed surfaces as per existing specification complete all as specified and directed. Note : GI pipe of dia 40 mm & 50mm will be measured & paid separately under respective items.
M&L for Earthing complete with Galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground with earth pit not less than 3.25 meter deep below ground level with top edge of plate not less than 2.5 meter below normal ground level connected to galvanised iron strip 32x6 mm as earth lead strip by means of nuts, bolts, check nuts, washers of galvanized iron as steel all as shown electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and elctrode by means of steel and GI pipe light grade 20mm bore dia bore for watering funnel with wire mesh, CI cover with frame , PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified. NOTE : 1. The unit rare includes for protection GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI strip of 32x6 from top of earth plate and GI light grade pipe 40mm bore upto 7.5 meter above ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
Supply, commissioning ,testing and installation of DG Set 15 KVA, two cylinder in line diesel engine, engine rated 21.6 BHP, 415 Volt, 50 Hz, 0.8 PF (Lag). 3 Phase 4 wire Engine will be coolant cooled by rail mounted, engine driven radiator of adequate capacity, with blower fan, fan guard, fan belts etc. The diesel engine shall be vertical, electric start, compression ignition, 4 stroke, designed to run continuously at 1500 RPM confirming to IS 10002, ISO-3046, BS 5514 standard with an overload capacity of 10 % for one hour in every 12 hrs of operation. Diesel Engine will comply with latest CPCB norms. Diesel engine set as per IS 10002 and alternator as per IS-4722/BS 5000 with inbuilt electronic speed governor including necessary anti vibration pad as recommended by the manufacture the following specification complete and all as specified in particular specifiation:- (A) Details : (a) The diesel engine comprising of following:- (i) MICRO/BOSCH fuel pump with Electronic Governor (ii) Dry type air cleanerZ (iii) Residential Silencer (iv) First fill of Lube oil (v) Lube oil filter (Replaceable element type) (vi) Fuel oil filter (Spin on type) (vii) Battery charging alternator (B) GEN-SET CONTROLLER Following indication / LCD display shall be available in the Digitial Gen Set controller: (i) Lube oil pressure (ii) Battery voltage (iii) Engine RPM (iv) Fuel level in the day tank (v) Engine Running hours indication. (vi) AC Current
(Item No.16 Contd----) (vii) AC Voltage (viii) AC Frequency (ix) Unit generated indicator (x) Suitable CTs for displaying the electrical parameters for the items as mentioned above safety alarms required in the Digital Genset controller. (xi) High engine temperature (xii) Low lube oil pressure (xiii) Low radiator water level (xiv) Low fuel level (xv) Battery high voltage (xvi) Under / over speed Safety trips required in the Digital Genset controller (xvii) High engine temperature (xviii) Low lube oil. (B) ALTERNATOR : Alternator, suitable to deliver 15 KVA at rated output at 1500 RPM, 380-440V 0.8PF(lag), 50Hz, 3 Ph. in SPDP enclosure, self-excited & Self - regulated (AVR), Brushless. The alternator conforms to IS: 4722/BS 5000 & will suitable for tropical condition. Full load efficiency of the alternator offered should be above 90%. class of insulation shall be H and temperature rise also limited to class H Enclosure shall conform to IP23. (C) Manual standard control Panel : The control Panel shall be made of CRCA sheet, floor mounted, indoor type, dust and vermin proof and powder coated and suitable for 415 volt, 3 phase, 50 HZ system. The panel shall consist of the following features : (i) Aluminium Bus Bar. (ii) Digital type Multi function Meter for measuring volts/Amps/Frequency/ Power factor/Oil Temp/KWH/KWAH/RPM etc. (iii) Monitor with display of engine safety features. (iv) Current Transformers of suitable ratio. (v) MCB/HRC fuses for control protection.
(Item No.16 Contd----) (vi) Indicating Lamps for DG ON/Load ON/Mains ON. (vii) MCCB of suitable rating with short circuit and overload protection. (viii) Earth studs. (ix) Push Button for Engine start/ Stop, Load ON/Off. (D) BASE FRAME: Suitable to couple above Engine & Alternator made from steel sheet metal (E) FUEL TANK : Capacity of the fuel tank should not beless then 12 Hrs continuous run with Inlet & Outlet arrangement, air vent & drain plug arrangement. (F) Battery : 12 V maintenance free batteries with connecting leads and terminals. (G) TECHNICAL SPECIFICATION OF ACOUSTIC ENCLOSURE CONSTRUCTION Following are some technical features of Acoustic Enclosure:- 1. The enclosure is modular in construction. 2. Base frame is made of Sheet metal. 3. Durable industrial locking system is provided on doors 4. Doors are gasketed with high quality EDPN gasket. (H) CORROSION RESISTANCE:- To make the enclosure weather proof:- (i) All sheet metal parts/components are hot dipped in seven tanks process, pre- treated and passivity. (ii) Sheet metal components shall be painted pure polyster powder coated based in black colour. (iii) Base frame is epoxy coated. (iv) Specially designed Residential Silencer is provided. (J) ACOUSTIC INSULATION: 1. Sound proofing of the enclosure done with quality Foam confirming to IS: 8183. 2. Acoustic form shall be fire retarded and fire resistant.
(Item No.16 Contd----) 3. Attenuates are provided to control sound at entry and exit to and from the container. Sound level < 75 dBA at one meter distance. 4. Specially designed Residential Silencer is provided. 5, Hooks for lifting/Shifting. 6. Fuel tank is specially designed and mounted inside of the enclosure as aintegral part of Acoustic enclosure. (K) VENTILATION AND AIR CIRCULATION: (i) Exhaust pipe is thoroughly insulated by covering it with glass wool and further gladded in Enclosure. (ii) Suitable slots/ventilators need to be provided in canopy for natural air circulation. (L) ELECTRICAL: (i) Neutral Body earthing points at the sides of enclosure are isolated through Dough Moulded compound. (ii) A light point with switch need to be provided inside the canopy. (M) SAFETIES: Emergency push button to stop the DG Set from outside, Lub oil level, Lub oil pressure, Fuel level indicator, Coolant level, Canopy temperature, High engine temperature. Note:- (i) Design/drawing/BOM of the DG set showing the dimension is to be obtained from the OEM/Auth supplier & is to be got approved from GE before placing final order to the manufacture. (ii) The cost of servicing including minor repairs/replacement such as topping up of coolent, engine/Lub diesel as well as Lub oil filters including periodical checking of the complete DG sets for the complete defect liability period and as when required is deemed to be included in the quoted rates. (iii) Any thing missed out in the technical specification but technically required for efficient working of DG Sets in deemed to be included in the quoted rates. (iv) The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test. (v) The quoted rate shall be deemed to be inclusive of 12 Hrs test run at site as specified in the PS presence of rep of Accepting Officer all testing arrangements/ equipment, resistive load including POL shall be made available by the contractor. (vi) Pre- dispatch inspection at factory premises of OEM shall be carried out by the Rep of Accepting Officer. (vii) Pre-commissioning of the DG set shall be carried out by the Rep of Accepting Offficer after installation of DG set at the site by the contractor and all the arrangements required for testing including (oil, Diesel, water/resistive load) deemed to be included in the quoted rate.
All as per Item No 16.00 here-in-before but of capacity 40 KVA 3 cylinder in line of rate 56 BHP complete all as specified.
SUDHA ENTERPRISES
HUMERS INFRATECH
SHARMA ENTERPRISES
NATIONAL CONSTRUCTION CO
MONA GENERATOR SEVICES PVT. LTD.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .