Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.5 L+₹1.2 L (11.2%)Rejected-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance L2 | |
| 3 | L3₹13.6 L+₹3.2 L (31.4%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
25 Feb 2022, 6:00 pmClosed
GARRISON ENGINEER AIRFORCE THANJAVUR
GARRISON ENGINEER AIRFORCE THANJAVUR
REPLACEMENT OF INTERNAL ELECTRIFICATION,LED LIGHT FITTINGS AND FIXTURES AND RENEWALS OF WIRING AND CONNECTED WORKS AT DOMESTIC AREA AT AIRFORCE STATION THANJAVUR AND AT KODIAKARAI
2022_MES_503937_1
8859/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
THANJAVUR
AS PER NIT
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER AIRFORCE THANJAVUR
₹28,000
Yes
19 Mar 2022
27 Jan 2022
26 Feb 2022
27 Jan 2022
25 Feb 2022
11 Feb 2022
Amount
THANJAVUR AREA
Taking drawn carefully old aluminium/copper point wiring for one light, socket or power etc incl all fitings such as switches, sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall / ceiling complete all as specified.
Point wiring complete with 1.5 Sq mm PVC insulated cable with copper conductor 1100 Volts grade, multistranded flame retardant low smoke (FRLS) in and including PVC conduit and conduit accessories of 20 mm dia concealed in walls, roof etc with and including provn of 1.6mm thick MS terminal boxes concealed/surface in walls with 3 mm thick laminated hylam sheet top cover for fixing switches, switch sockets outlets etc including provn of 1.5 Sqmm multistranded copper conductor cable PVC insulated unsheathed as earth continuinity cable for one light point controlled by one switch complete all as specified.
All as per item No 3 mentioned here-in-before but for One fan point controlled by one switch and regulator complete all as specified.
All as per item No 3 mentioned here-in-before but for one socket outlet 3 pin 5 amps on same board complete all as specified.
All as per item No 3 mentioned here-in-before but for One socket outlet 3 pin 5 amps on independent board complete all as specified..
All as per item No 3 mentioned here-in-before but for One bell point controlled by one switch complete all as specified.
All as per item No.3 above but with 4 sq mm cable for one 3 pin 15 amps switch socket outlet on independent board with 4 sq mm cable for earth wire drawn through and including 20mm dia PVC conduit and accessories complete all as specified.
Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with multistranded copper conductor flame retardant low smoke (FRLS) including PVC rigid non metallic 25 mm PVC casing caping (double Lock) including PVC polycarbonate/PVC/rectangular block/box of suitable size fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nominal cross sectional area PVC insulated unsheathed single core multistranded copper conductr cable as earth continuity conductor connected to main switches/DBs or common earth dolly complete all as specified.
All as per item No 9 mentioned here-in-before but for one ceiling fan / Exhaust fan point, controlled by one way switches 5/6 Amps complete all as specified..
All as per item No 9 here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the independent board complete all as specified.
All as per item No 9 here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the same board with other switches complete all as specified.
All as per item No 9 here-in-before but for one bell/buzzer point controlled by one bell push button on independent board complete all as specified.
All as per item No 9 here-in-before but for point wiring with 4 Sq mm (nominal cross sectional area) single core stranded copper conductor for one switch socket out let point, 15/16 amps on the independent board.
Fixing only old serviceable tube light fittings of any type complete all as specified. (Note : Old serviceable light fittings shall be obtained from taking down of ser item No 2 here-in-before).
Lamp holder, insulated body, with back plate suitable for batten fittings/pendent fittings white/ivory finish complete all as specified.
Switch piano flush button, white/ivory finish, 5/6 amps, single pole, one way complete all as specified.
Fixing only Switch piano flush button, white/ivory finish, 5/6 amps, single pole, one way complete all as specified. (Note : Old serviceable switch shall be obtained from taking down of ser item No 2 here-in-before).
Bell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified.
Ding dong bell, AC, Single pole, 220/240 Volts, white/ivory finish, surface type complete all as specified.
Switch socket combination, 2 and 3 Pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type white/ ivory finish complete all as specified.
Switch socket combination, 2 in 1, 6 pin, 5/6 amps and 15/16 amps multipurpose, white/ivory finish, flush non shutter non inter locking type complete all as specified.
Sheet metal enclosure for 2 way Distribution Boards (DB’s), single door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"s/lsolators after and including taking down old DB with MCB complete all as specified.
Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB's/lsolators after and including taking down old DB with MCB complete all as specified. (Make : Legrand cat No 607710 or equivalent & approved model of makes listed in particular specification.
Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB's/lsolators after and including taking down old DB with MCB complete all as specified. (Make : Legrand cat No 607711 or equivalent & approved model of makes listed in particular specification.
Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Tripple pole & neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB's / lsolator’s after and including taking down old DB with MCB complete all as specified. (Make : Legrand cat No 607715 or equivalent & approved model of makes listed in particular specification..
Ceiling rose, surface Bakelite, large type, 220/240 volts, three terminals, white/ivory finish complete all as specified.
Earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4.0mm dia earth lead by means of nuts, bolts, check nuts, GI washers earth wire protected by galvanised iron or steel all as shown in electrical Plate No-3 connected to earthing test point all as specified or indicated including testing on completion.
Fan regulator electronic type suitable for 300 Watt (heavy duty) type 250 V, AC for ceiling fan complete all as specified..
Sub main wiring with 2 run of 4 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified.
Sub main wiring with 2 run of 6 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified.
Supply and fixing in replacement of LUMILINE PLUS wall mounted LED Batten 20 Watt LED, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified .Make as per Havells Cat Part.No: LUMILINEPLUSBS20WLED865SPCSS or equivalent & approved model of makes listed in particular specification.
Supply and fixing in replacement of LUMILINE PLUS wall mounted LED Batten 10 Watt LED, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified .Make as per Havells Cat Part.No: LUMILINEPLUSBS10WLED865SPCSS or equivalent & approved model of makes listed in particular specification.
Supply and fixing in replacement PLUTO NEO PANEL 2 x 2 42 Watt LED ceiling light fitting suitable for arm strong /grid ceiling with electronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size complete all as specified . Make:-Havells Cat Part No. PLUTONEO2X2PLR42WLED857S or equivalent & approved model of makes listed in particular specification.
Supply and fixing in replacement PLUTO 1 x 1, 15 Watt LED ceiling light fitting suitable for arm strong /grid ceiling with electronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size complete all as specified. Make:-Havells Cat Part PLUTO1X1PLR15WLED857S equivalent & approved model of makes listed in particular specification.
Supply and fixing in replacement PLUTO NEO PANEL 36 Watt LED ceiling light fitting 4 x 1 feet suitable for arm strong /grid ceiling with electronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size complete all as specified . Make:-Havells Cat Part PLUTONEO4x1PLR36WLED857S equivalent & approved model of makes listed in particular specification.
Supplying and fixing in replacement of HEXA 10W IP66 environmental friendly, ultra modren energy saving surface mounted decorative hexagonal bulk head back lit LED luminaire comprising of high brightness LEDs and making necessary connections complete all as specified.Make Havells Cat Part. No HEXAFT10WLED857SSYMBOPC orequivalent & approved model of makes listed in particular specification.
MCB, Tripple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA complete all as specified (Make : Legrand Cat No 408683 or equivalent & approved model of makes listed in particular specification.
MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified (Make : Legrand Cat No 408609 to 408617 or equivalent & approved model of makes listed in particular specification.
MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified (Make : Legrand Cat No 408618 to 408620 or equivalent & approved model of SIEMENS/ MERLIN GERIN).
MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified (Make : Legrand Cat No 408587 to 408595 or equivalent & approved model of makes listed in particular specification.
KODIAKKARAI AREA
Taking drawn carefully old aluminium/copper point wiring for one light, socket or power etc incl all fitings such as switches sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall / ceiling complete all as specified.
Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with multistranded copper conductor including PVC rigid non metallic 25 mm PVC casing caping (double Lock) including PVC polycarbonate/PVC/rectangular block/box of suitable size fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nominal cross sectional area PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DBs or common earth dolly complete all as specified.
All as per item No 44 mentioned here-in-before but for one ceiling fan / Exhaust fan point, controlled by one way switches 5/6 Amps complete all as specified.
All as per item No 44 here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the independent board complete all as specified.
All as per item No 44 here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the independent board complete all as specified.
All as per item No 44 here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the same board with other switches complete all as specified..
All as per item No 44 here-in-before but for point wiring with 4 Sq mm (nominal cross sectional area) single core stranded copper conductor for one switch socket out let point, 15/16 amps on the independent board complete all as specified..
Lamp holder, insulated body, with back plate suitable for batten fittings/pendent fittings white/ivory finish complete all as specified.
Switch piano flush button, white/ivory finish, 5/6 amps, single pole, one way complete all as specified.
Socket outlet, 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified.
Socket outlet, 2 in 1, 3 pin, 5A complete all as specified.
Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB's / lsolators after and including taking down old DB with MCB complete all as specified and directed. (Make : Legrand cat No 607710 or equivalent & approved model of makes listed in particular specification.
Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB's/lsolators after and including taking down old DB with MCB complete all as specified. (Make : Legrand cat No 607711 or equivalent & approved model of makes listed in particular specification.
Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Tripple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB,s / lsolator’s after and including taking down old DB with MCB complete all as specified and directed. (Make : Legrand cat No 607715 or equivalent & approved model of makes listed in particular specification.
Ceiling rose, surface Bakelite, large type, 220/240 volts, three terminals, white/ivory finish complete all as specified.
Earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4.0mm dia earth lead by means of nuts, bolts, check nuts, GI washers, earth wire protected by galvanised iron or steel all as shown in electrical Plate No-3 connected to earthing test point all as specified or indicated including testing on completion.
Fan regulator electronic type suitable for 300 Watt (heavy duty) type 250 V, AC for ceiling fan complete all as specified.
Sub main wiring with 2 run of 6 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FR) of working voltage 1100 volts grade with stranded copper conductor including one run of 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified.
E-Lite LED Pride Plus Neo Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack.wall mounted LED Batten 20 Watt and integrated electronic driver complete all as specified. Make as per Havells Cat Part.No: LHEXACP7IN1W020 20W LED 6500 K equivalent & approved model of makes listed in particular specification.
E-Lite LED Pride Plus Neo Decorative ultra slim square profile 10 Watt LED surface mounted fitting and integrated electronic driver complete all as specified and directed.Make as per Havells Cat Part.No: LHEXACP7IN1W010 W LED 6500 K or equivalent & approved model of makes listed in particular specification.
Supply and fixing in replacement of LED security Lights 30 watt with best in class design & robust heat sink along with class leading IP, IK & Surge protections for long lasting performance.and integrated electronic driver complete all as specified and irected.Make as per Havells Cat Part.No: LHEXAYP7PN6K030, 30 W LED 6500 Kor Equivalent in Philips & CG.
MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed (Make : Legrand Cat No 408609 to 408617 or equivalent & approved model of makes listed in particular specification.
MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed (Make : Legrand Cat No 408618 to 408620 or equivalent & approved model of makes listed in particular specification.
MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified and as directed (Make : Legrand Cat No 408587 to 408595 or equivalent & approved model of makes listed in particular specification.
Dimantling and taking out ceiling fan 230 volts 1200/1400mm sweep any make cutting the old burnt winding, rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of 2.25/3.15 MFD capacitor, replacement of MS split clamp 02 nos with rubber reel and painting after completion of rewinding process complete all as specified.
Supply and fixin in replacement of ball bearing of size 6200 to 6204 suitable for ceiling fan 1200/1400mm sweep complete all as specified.
Dimantling and taking out Exhaust fan 230 volts 200 to 450mm sweep any make cutting the old burnt winding, rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of capacitor, replacement of gun metal bushes and painting after completion of rewinding process complete all as specified.
Supply and fix in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 32 amps capacity complete all as specified.
Supply and fix in replacement fan capacitor 2.5 MFD complete all as specified.
BKR Enterprises
p.chinnasamy
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .