Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹15.0 L+₹2.6 L (21.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
7 Apr 2025, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
As per tender documents
2025_MES_700934_1
CWE/MTR/E/ of 2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (East) Mathura
As per NIT documents
7 documents required · 7 mandatory
₹500
GE (East) Mathura
₹50,000
Yes
24 Jul 2025
10 Mar 2025
14 Apr 2025
10 Mar 2025
7 Apr 2025
24 Mar 2025
Amount
Taking down carefully aluminum/copper point wiring (light ,fan, socket any type, power, bell etc. ) complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fittings etc) and removing the material from site and making good the disturbed surfaces of walls ceiling etc complete all as specified and directed. ( Note: Credit for above items should be made as per credit Schedule separately)
Taking down carefully by Submain wiring of any type complete and making good disturbed sufaces to match with the existing surfaces omplete all as specified and directed.
Taking down old unserviceable existing SPN/TPN DBs / enclousers any size and type / any descriptions as iron sheet scrap including MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed
M & L for Sub Main Wiring wiring with two runs single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 4 Sqmm copper green colour earth wire omplete all as specified and directed. Note: Two runs of 4 Sq mm (P&N), one run of 4 Sq mm earth wire & One run of PVC casing and caping will be measured as one RM.
M & L for Sub Main Wiring with two runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 6 Sqmm copper green colour earth wire omplete all as specified and directed. Note: Two runs 6 Sq mm (P&N), one run of 6 Sq mm earth wire & One run of PVC conduit will measured as one RM.
M & L for Sub Main Wiring with two runs single core 10 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 10 Sqmm copper green colour earth wire omplete all as specified and directed. Note: Two runs 10 Sq mm (P&N), one run of 10 Sq mm earth wire & One run of PVC conduit will measured as one RM.
S&F TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail ,blanking Plates, cable ties for cable management, 440 V, 4 way complete all as specified including fitting suitable for MCBs with connections complete all as specified and directed. Note : -MCB & MCB /MCCB DBs shall be of same make and measured and paid seperately under respective items of Sch A. DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as pe directed & rate shall be included in the items.
Supply & fixing powder coated CRCA steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted, triple pole and neutral 4 way with 100 Amps rated copper bus bar, type complete all as specified and directed.
Supply & fix in replacement of MCCB 160 Amps, breaking cap 25 KA, 4 Pole, 415V, 100% Icu complete all as specified and directed.
Supply & fix in replacement of MCCB 125 Amps, breaking cap16 KA, 4 Pole, 415V complete all as specified and directed.
Supply & fix in replacement of MCB 100 Amps,breaking cap16KA, 4 Pole, 415V complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, 1100 volts grade copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) including with modular flush metal boxes with modular cover plates & frame for mounting modular switches, sockets, regulators etc or including sunk cast iron /pressed steel/terminal boxed for mounting flush type switches/sockets etc with 3 mm thick phenolic laminated sheet covers and including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified in current SSR Part-I & II complete all as specified and directed as described below:-
(a) One light/ fan point controlled by one way switch 5 amp complete.
(b) One 3 pin 5 Amps socket point controlled by one way switch on same board.
(c) One 3 pin 5 Amps socket point controlled by one way switch on independent board.
(d) One bell point controlled by one push button.
(e) One light point controlled by two 2-way switches.
All as per item No. 12 but for 3 pin / 5 pin 16 Amps sockets outlet with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent Point wiring complete all as specified and as directed .
Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete all as specified and directed.
Supply and Fixing Modular bell Push switch 6 Amps with indicator single pole one-way, 1 Module complete all as specified and directed.
Supply and Fixing Modular switch 16 Amp single pole one way,1 Module complete all as specified and directed.
Supply & Fixing Modular fan Regulator electronic step type 2 Module complete all as specified and directed.
Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete all as specified and directed.
Supply and Fixing Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified and directed.
Supply and Fixing Modular switch 6 Amps single pole two-way, 1 Module complete all as specified and directed.
S&F in replacement switch piano type , SP, one way, flush type 5 Amps complete all as specified and directed.
S&F in replacement socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified and directed.
S&F in replacement socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified and directed.
S&F in replacement switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and directed.
S&F in replacement bell push siwtch piano flush type, SP, one way, 5 Amps complete all as specified and directed.
S&F in replacement ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and directed.
S&F in replacement lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fix in replacement mini MCB enclosure including DP 20 amp, type 'C' curve complete all as specified and directed.
S&F in replacement Bell Ding dong type, 230 Volts complete all as specified and directed.
S&F in replacement fan Regulator, flush type, socket type, electronic step type complete all as specified and directed.
Supply & fixing in repair indoor decorative ultra slim surface /Wall mounted LED batten tube light complete fitting 1x 20 watt LED Tube fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Supply & fixing in repair indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1X9 watt LED Tube fitting (size within 600x25x40 mm) suitable for mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K,>100Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Supply & fix in repair surface mounted bulk head LED light fitting including 10 watt LED lamp complete with all accessories and connectioncomplete all as specified and directed.
Supply and fix LED 9 W suitable for normal holder (Base Cap B22) complete all as specified and directed.
Supply and fix LED 7 W suitable for normal holder (Base Cap E14) complete all as specified and directed.
Supply and install in replacement of 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V including all connectionscomplete all as specified and directed.
Supply & fix in repair recess type, 36/34 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Supply & fixing in repair indoor wall mounted fitting, brushed nickel finishfixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts complete all as specified and directed.
S&F in repair LED post top light fitting 30W IP-65 rated complete all as specified and directed.
S&F in repair LED Round/square recess mounted slim downlighter 12 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K complete all as specified and directed.
S&F in repair LED Round/square recess mounted slim downlighter 15 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K complete all as specified and directed.
M&L for building security light bracket made out of 40mm dia light grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole/wall including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including two coats of aluminium paint over a coating of red oxide primer including taking down old unserviceable bracket as scrap any size / description complete all as specified and directed.
S&F in replacement MCB distribution board, SPN 12 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and directed.
S&F in replacement MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and directed.
S&F in replacement MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and directed.
Supply & fix in replacement MCB SPN 63 Amps,' C' series , bracking cap10KA, 240V complete all as specified and directed.
Supply & fix in replacement of MCB SPN 40 Amps,' C' series , bracking cap 10KA, 240V complete all as specified and directed.
Supply & fixing in replacement of MCB SPN 6-32 Amps, ' C' series ,bracking cap 10KA, 240V complete all as specified and directed.
Supply & fixing in replacement of MCB SP 6 - 32 Amps, ' C' series ,bracking cap 10KA, 240V complete all as specified and directed.
Supply and fix in replacement SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Volts with all connection complete all as specified and directed.
Supply & fix in replacement metal clad SPN plug top 20 Amp for fixing on AC Box complete all as specified and directed.
Supply & fix modular MCB DP 16 Amp 'C' series, 240 V complete all as specified and directed.
S&F in repair Plastic Surface mounting box 1 / 2 module gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge.
S&F in repair Plastic Surface mounting box 3 / 4 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and directed.
S&F in repair Plastic Surface mounting box 6 / 8 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and directed.
Supply & replacement of 3 mm thick laminated mica sheet top cover suitable for switch board 3 way to 6 way including removing & re-fixing of existing switch / socket and complete connection complete all as specified and directed. Note :- Replacement of unserviceable switch / socket / regulator shall be measured & Paid separately under relevent item of Sch -A
Supply & replacement of 3 mm thick laminated mica sheet top cover suitable for switch board 8 way to 12 way including removing & re-fixing of existing switch / socket and complete all as specified and directed. Note :- Replacement of unserviceable switch / socket / regulator shall be measured & Paid separately under relevent item of Sch -A
M&L for Modular metal flush box 1/2 Module including taking down of old u/s metal box and making good to the disturbed suraces complete all as specified and directed.
M&L for Modular metal flush box 3 Module including taking down of old u/s metal box and making good to the disturbed suraces complete all as specified and directed.
M&L for Modular metal flush box 4 Module including taking down of old u/s metal box and making good to the disturbed suraces complete all as specified and directed.
M&L for Modular metal flush box 6 Module including taking down of old u/s metal box and making good to the disturbed suraces complete all as specified and directed.
M&L for Modular metal flush box 8 Module including taking down of old u/s metal box and making good to the disturbed suraces complete all as specified and directed.
M&L for modular white cover plate with frame, 1 / 2module complete all as specified and directed.
M&L for modular white cover plate with frame, 3 module complete all as specified and directed.
M&L for modular white cover plate with frame, 4 module complete all as specified and directed.
M&L for modular white cover plate with frame, 6 module complete all as specified and directed.
M&L for modular white cover plate with frame, 8 module complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces ( making good all to the disturbed surfaces as per existing) including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing including gang box / 2.0mm thick MS terminal box as per site requirement for fixing switches, sockets, fan regulators etc fixed to wall with 3mm thick laminated sheet top cover complete all as specified for:-
(a) One light point/ fan point / bell point controlled by one switch
(b) One 3 pin 5 Amps socket point controlled by one way switch on same board.
(c) One 3 pin 5 Amps socket point controlled by one switch on independent board
All as per item No. 68 but with 4.0 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4.0 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed.
S/F switch piano type , SP, one way, flush type 5 Amps complete all as specified and directed.
S/F socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified and directed.
S/F socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified and directed.
S/F switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and directed.
S/F fan Regulator piano flush type, socket type, electronic step type complete all as specified and directed.
Supply and Fixing in repair modular switch 6 Amps single pole one-way, 1 Module complete all as specified and directed.
Supply and Fixing in repair Modular switch 16 Amp single pole one way,1 Module complete all as specified and directed.
Supply & Fixing in repair modular fan Regulator electronic, 2 Module step type complete all as specified and directed.
Supply and Fixing in repair modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete all as specified and directed.
Supply and Fixing in repair modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified and directed.
Supply and fix in SP enclosure modular type with a two pin and earth plug and socket complete with Single Pole MCB of rating 20 Amps, 240 Volts complete with all connection as directed.
Supply and fix in replacement SP enclosure modular type with a two pin and earth plug and socket complete with Single Pole MCB of rating 16 Amps, 240 Volts complete with all connection complete all as specified and directed.
Taking down carefully service connection of any type complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out complete all as specified and directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches / duct / fixing on walls / poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole / Main Panel Box and testing complete all as specified and directed of following sizes :- Note:- HDPE pipe rate shall be deemed in quoted rate above.
(a) XLPE Cable size 10 sq mm 2 core
(b) XLPE Cable size 16 sqmm 4 core
Taking down ceiling fans / exhaust fans / fresh air fans of any make and type and rectifying the defects including replacement of unserviceable parts and testing and reinstalling at same or any other location complete all as specified and directed. Notes: - (i). The unit rate is deemed to include the cost of taking down carefully fans from existing position, any location in the AOR of AGE E/M office after disconnecting electric connections, sealing cable ends, bringing to MES store yard and refixing in same as different locations after repair/painting work etc complete all as directed by Engineer-in-charge. (ii) Cost of major items such as ball bearing, gun metal bush, capacitors, canopy, blades and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switches, binding insulation tape to the naked wires, replacement of unserviceable clamps, connector, nuts and bolts, split pins, rubber reel, washers, greasing, including flexible twin core copper wire of suitable size from existing ceiling rose to fan etc. complete will be provided by the contractor without any extra cost to the department and cost of these minor items or works will be deemed to be included in the quoted rates against this item and nothing extra shall be paid on this account.
Material and labour for spray painting on ceiling fan (size 1200 mm / 1400 mm) with two coat complete with synthetic enamel paint by spray gun including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint complete all as specified and directed.
Dismantling of worn out / burnt out windings of 1200 mm sweep ceiling fan and re-winding the motor of ceiling fan with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut and testing for original and consumption complete all as specified and directed.
Dismantling of worn out / burnt out windings of exhaust fan / fresh air fan any type and rewinding the motor with super enameled copper wire of existing gauge, varnishing with approved quality insulating varnish complete and testing for original and consumption complete all as specified and directed of following sizes :-
150/200/250 mm sweep
300 mm sweep.
450 mm sweep.
Supply only capacitors 2.5 MFD suitable for all types of fans complete all as specified and directed.
Supply only capacitors 4.0 MFD suitable for all types of exhaust fans complete all as specified and directed.
Supply only ball bearing suitable for ceiling fan/exhaust fan/fresh air fan of any type as per existing required including proper alignment of shaft and testing complete all as specified and directed.
Supply only bush made out of Gun metal suitable for ceiling fan/exhaust fan/fresh air fan as required at site complete all as specified and directed.
Supply only down rod MS grade 15 mm bore of length upto 90 cm suitable for ceiling fans of any type and size including cutting, drilling holes, making thread and painting complete all as specified and directed.
Supply only 1200 mm sweep ceiling fan blade of type and make as existing complete all as specified and directed.
Supply only exhaust fan motor suitable for 8'' to 10'' PVC ventilator/ fresh air fan, copper winding, 230V, 50 Hz , as per existing make with fixing accessories to mount on frame complete all as specified and directed.
Supply and fixing in replacement of fresh air/ ventilator fan made of sturdy engineering plastic with buil in louvers, AC, 230Volt single phase, 50 Hz, incl depositing the old one in MES store yard complete all as specified and directed of following sizes :-
150 mm Sweep.
200 mm Sweep.
300 mm Sweep.
Taking down of unserviceable ceiling fan any type and size with down rod, blade complete and supply and fixing ceiling fan AC 230 Volt single phase five star rating and fixing accessories complete of 1200 mm sweep incl depositing the old one in MES store yard complete all as specified and directed.
Earthing complete all shown as electrical plate No -03 of MES Sch part -I complete all as specified and directed including the following:- (i) GI earth plate of size 60x 60cm x6.0mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.50 metres below ground level. (ii) Earth plate surrounded by and packed with charcoal and common salt in alternative layers. ( n.exc 15 cms each layer) (iii) 4 mm GI wire from earth plate to MCB DB/machinery including necessary GI bolts, nuts check , washers, thimbles etc. (iv) 20 mm bore, light grade, Gi pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontaly to the earth pit. (v) 15 mm dia bore G. I. medium grade pipe for protection of earth wire. (vi) Cement concrete chamber of PCC (1:3:6) type C-2 using 40mm graded stone aggregate. The chamber shall be constructed one metre away from edge of earth pit. (vii) 50 mm thick precast cover of reinforced cement concrete(1:2:4) type B-1 using 20mm graded stone aggregate with steel rainforcement 8 mm dia mild steel TMT bar @ 10 Cm c/c both ways and MS angle iron 50x50x6mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces with suitable handle to lift the cover. (viii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance of 50 m as directed.
LOKESH ELECTRICAL (BID ID -3274211)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .