| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.7 LAdmitted-Finance | -23.21% | ₹7.7 L | L1 | Admitted-Finance |
| 2 | L2₹8.0 LAdmitted-Finance PLOT NO 454 RAIGRON KI KOTHI PANCHAM PATTI DELHI BYPASS ROAD JAIPUR RAJASTHAN 302002 | JAIPUR | RAJASTHAN | 302002 | -20.10% | ₹8.0 L | L2 | Admitted-Finance |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
16 Jan 2026, 6:00 pmClosed
EXECUTIVE ENGINEER MURLIPURA ZONE
JAIPUR NAGAR NIGAM PANDIT DEENDAYAL UPPADHYAY BHAWAN LALKOTHI TONK ROAD JAIPUR
CONSTRUCTION OF RAILING, BOUNDARY WALLS, FOOTPATH AND OTHER DEVELOPMENT WORK IN PUBLIC PLACES AND RAILING IN VAISHNAV VIHAR, SHYAM NAGAR, SITA VIHAR, PAWANPURI, BHOMIYA NAGAR, RAMANPURI IN WARD NO. 12
2026_DLB_524508_1
251 EXECUTIVE ENGINEER MURLIPURA ZONE
Open Tender
Civil Works
120 days
JAIPUR
As Per Bid Documents
3 documents required · 3 mandatory
₹500
ONLINE PAY IN JAIPURMC WEBSITE
₹20,000
Yes
20 Jan 2026
6 Jan 2026
17 Jan 2026
6 Jan 2026
16 Jan 2026
6 Jan 2026
(4.10.1.1) Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level In all types soils/ saturated soil such as moorum,sand, sandy silt,clay, black cotton soil, kankar, etc.
(21.1.8) Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level :1:5:10 (1 cement : 5 fine/ coarse sand : 10 graded stone aggregate 40 mm nominal size)
(25.1.1) Random rubble masonry with hard stone in foundation and plinth Cement mortar 1:6 (1 cement : 6 coarse sand)
(25.2) Extra for random rubble masonry with hard stone in superstructure above plinth level and upto two stories
(21.7.1) Providing and laying damp-proof course with cement concrete grade M-15 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar.
(9.2) Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in concrete mixer, laid manualy, compacted with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.
(9.11) Providing and fixing of 60mm thick precast cement concrete interlocking paver block casted with rubber moulds in approved reflective colour and design having minimum compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications.
(10.1) Providing and fixing precast cement concrete M-20 grade (Using mechanical Concrete Mixer) kerb stone top and bottom width 115 and 165 mm respectively, 250 mm high on 150 mm thick PCC M-10 grade foundation as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.
(29.26.2) Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
(32.33.1) Applying one coat of cement primer of approved brand and manufacture on wall surface New work (Two or more coats applied @ 3.84 kg/10 sqm).
(32.1.2) Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar 1:6 (1 cement : 6 fine/ coarse sand)
(4.13) Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
BOQ_935984.xls
BOQ • 0.29 MB
eproc0251xenmpz.pdf
Tender Documents • 3.72 MB
Download all tender documents and submit your bid